| Plan Review Stops For Permit 06110144 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-06 |
Time |
10:03 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-02-06 |
Time |
10:03 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-11 |
Time |
10:11 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-01-11 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2007-01-11 10:19:48 | BUILDING PLAN REVIEW | | | PERMIT: 06110144 | | | ADD: 500 AUSTRALIAN AVE SUITE# 910 | | | CONT: KARL CORP CONSTRUCTION SERVICES | | | TEL: (561)718-3799 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) NOT CAUGHT ON THE FIRST REVIEW SEE SHEET | | | M-1 STAIR TOWER # 1. | | | 1019.1.2 PENETRATIONS. | | | PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | | ENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR INDEPENDENT | | | PRESSURIZATION, SPRINKLER PIPING, STANDPIPES, | | | ELECTRICAL RACEWAY FOR FIRE DEPARTMENT COMMUNICATION | | | AND ELECTRICAL RACEWAY SERVING THE EXIT ENCLOSURE AND | | | TERMINATING AT A STEEL BOX NOT EXCEEDING 16 SQUARE | | | INCHES (0.010 M 2 ). SUCH PENETRATIONS SHALL BE | | | PROTECTED IN ACCORDANCE WITH SECTION 712 . THERE SHALL | | | BE NO PENETRATIONS OR COMMUNICATION OPENINGS, WHETHER | | | PROTECTED OR NOT, BETWEEN ADJACENT EXIT ENCLOSURES. | | | | | | 1019.1.3 VENTILATION. | | | EQUIPMENT AND DUCTWORK FOR EXIT ENCLOSURE VENTILATION | | | SHALL COMPLY WITH ONE OF THE FOLLOWING ITEMS: | | | 1.SUCH EQUIPMENT AND DUCTWORK SHALL BE LOCATED | | | EXTERIOR TO THE BUILDING AND SHALL BE DIRECTLY | | | CONNECTED TO THE EXIT ENCLOSURE BY DUCTWORK ENCLOSED IN | | | CONSTRUCTION AS REQUIRED FOR SHAFTS. | | | 2.WHERE SUCH EQUIPMENT AND DUCTWORK IS LOCATED | | | WITHIN THE EXIT ENCLOSURE, THE INTAKE AIR SHALL BE | | | TAKEN DIRECTLY FROM THE OUTDOORS AND THE EXHAUST AIR | | | SHALL BE DISCHARGED DIRECTLY TO THE OUTDOORS, OR SUCH | | | AIR SHALL BE CONVEYED THROUGH DUCTS ENCLOSED IN | | | CONSTRUCTION AS REQUIRED FOR SHAFTS. | | | 3.WHERE LOCATED WITHIN THE BUILDING, SUCH | | | EQUIPMENT AND DUCTWORK SHALL BE SEPARATED FROM THE | | | REMAINDER OF THE BUILDING, INCLUDING OTHER MECHANICAL | | | EQUIPMENT, WITH CONSTRUCTION AS REQUIRED FOR SHAFTS. | | | IN EACH CASE, OPENINGS INTO THE FIRE-RESISTANCE-RATED | | | CONSTRUCTION SHALL BE LIMITED TO THOSE NEEDED FOR | | | MAINTENANCE AND OPERATION AND SHALL BE PROTECTED BY | | | SELF-CLOSING FIRE-RESISTANCE-RATED DEVICES IN | | | ACCORDANCE WITH CHAPTER 7 FOR ENCLOSURE WALL OPENING | | | PROTECTIVES. | | | EXIT ENCLOSURE VENTILATION SYSTEMS SHALL BE INDEPENDENT | | | OF OTHER BUILDING VENTILATION SYSTEMS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-27 |
Time |
08:18 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-11-27 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2006-11-27 08:17:49 | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 06110144 | | | ADD: 500 AUSTRALIAN AVE SUITE# 910 | | | CONT: KARL CORP CONSTRUCTION SERVICES | | | TEL: (561)718-3799 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) 110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT | | | G) NUMBER OF FLOORS | | | H) SQ. FT. FOOTPRINT | | | I )OCCUPANT LOAD | | | J) 2004 EXISTING BUILDING CODE, LEVEL OF ALTERATION? | | | | | | 3) SHEET A-1.01 NOTE# 5 INDICATES THAT THE DRYWALL ON | | | THE UN-OCCUPIED SIDE OF THE 1 HOUR FIRE RATED WALL BE | | | UNFINISHED. DOES UNFINISHED MEAN NO PAINT OR THAT NO | | | MUD AND TAPE TO BE APPLIED? PLEASE PROVIDE INFORMATION | | | IN COMPLIANCE WITH 713.1 FOR FIRE-RESISTANCE JOINT | | | SYSTEM | | | THAT WILL BE USED? | | | | | | 4) SHEET A-1.01 DETAIL# 2 INDICATESTHE USE OF A CUT | | | IN FIRE | | | EXTINGUISHER BOX BUT THE DETAIL ONLY SHOWS 1 LAYER OF | | | DRYWALL? | | | PLEASE PROVIDE A U.L. LISTING OR GYPSUM ASSOCIATION | | | NUMBER | | | WHERE THIS OCCURS? | | | | | | 5) SHEET A-3.01 DETAIL 1 INTERIOR ELEVATIONS INDICATES | | | A SINK | | | AND CABINET BELOW, SHOW COMPLIANCE WITH: | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL | | | BE MOUNTED WITH THE COUNTER NO HIGHER | | | THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-05 |
Time |
07:20 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-04-05 |
Time |
06:35 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-09 |
Time |
13:15 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-02-09 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-29 |
Time |
17:33 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-01-29 |
Time |
17:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-12 |
Time |
15:27 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-01-11 |
Time |
17:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-07 |
Time |
13:49 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-11-07 |
Time |
13:18 |
Sent To |
I |
|
| Notes |
| 2006-11-07 13:49:01 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} INDICATE COMPLIANCE WITH CHAPTER 13 | | | OF THE FLORIDA BLDG CODE. 13.413, | | | 13.414, 13.415. SHOW TIME CLOCK AND | | | OCCUPANCY SENSOR LOCATIONS ON THE PLAN. | | | | | | 2} PROVIDE PERFORMANCE CALCULATIONS FOR REVIEW PER | | | 13-415.2.AND CERTIFICATION PER 13-103.1.2. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-02-05 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-02-05 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-01-17 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-01-17 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2007-01-17 10:03:01 | ***DENIED*** | | | | | | 1) COMMENTS FROM LAST FIRE REVIEW HAVE BEEN ADDRESSED. | | | | | | 2) PLEASE SEE BUILDING COMMENT #2 REGARDING | | | PENETRATIONS INTO EXIT ENCLOSURES. IN ADDITION TO FBC, | | | SEE NFPA 101 2003 EDITION, SEC.7.1.3.2.1 (6). | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | (561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-04 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-04 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2006-12-04 15:18:32 | *****UNSAT***** | | | | | | | | | | | | 1.NFPA 101 - 2003 EDITION AND THE FLORIDA FIRE | | | PREVENTION CODE - 2004 EDITION SHALL BE REFERENCED. | | | | | | 2.AMEND SHEET A-1.01, KEYED NOTE #1, TO READ 2A:10BC | | | FIRE EXTINGUISHER. | | | | | | 3.IN ADDITION TO THE NUMERICAL ADDRESS OF THE | | | BUILDING, THE SUITE NUMBER (910) SHOULD ALSO BE | | | INCLUDED IN THE TITLE BLOCK OF THE SUBMITTED PLANS TO | | | PINPOINT THE LOCATION OF THE SCOPE OF WORK. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-22 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-22 |
Time |
11:55 |
Sent To |
M |
|
| Notes |
| 2007-03-22 11:55:37 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-22 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-22 |
Time |
11:53 |
Sent To |
E |
|
| Notes |
| 2007-03-22 11:54:14 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-22 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-22 |
Time |
11:50 |
Sent To |
P |
|
| Notes |
| 2007-03-22 11:50:36 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-08 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-08 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2007-02-08 16:35:00 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-24 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-24 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2007-01-24 10:02:06 | TO "BOB"#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-28 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-28 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2007-01-09 16:01:50 | TO "BOB"#13 | | 2006-12-28 14:48:15 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-06 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-08 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2006-11-20 16:17:09 | TO "BOB"#5 | | 2006-11-08 16:51:31 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-28 |
Time |
10:39 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-03-28 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2007-03-28 10:39:51 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-26 |
Time |
08:09 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-01-26 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-11 |
Time |
11:24 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-01-11 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2007-01-11 11:30:48 | *** DENIED *** | | | 1) MISSED ON FIRST REVIEW. SEE PAGE M-1 EXISTING | | | STAIRWAY. DUCTS ARE NOT PERMITTED IN STAIRWAYS ,SEE | | | 2004 FBC 1019.1.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-22 |
Time |
15:26 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-22 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-05 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-05 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2007-04-05 09:40:28 | REVISION; CHANGED VENTED LINE TO MECHANICAL VENT AT | | | BREAK SINK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-06 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-06 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-17 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-17 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2007-01-17 14:39:14 | DENIED; | | | 1.BREAK SINK CABINET DOORS CANNOT SWING INTO THE CLEAR | | | FLOOR SPACE. SHOW DETAIL HOW GARBAGE DISPOSAL SHALL BE | | | INSTALLED AND STILL ALLOW THE 19" REQUIRED UNDER SINK. | | | 2.WATER HAMMER ARRESTOR REQUIRED FOR ICE MAKER. SEE | | | PLUMBING SECTION 604.9. SHOW ON WATER RISER DIAGRAM AND | | | LIST MANUFACTURE AND TYPE ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-06 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-06 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2006-12-06 13:54:09 | DENIED; | | | 1.BREAKSINK;GARBAGE DISPOSAL WILL NOT ALLOW A | | | FRONTAL APPROACH. SEEFBC-2004 CHAPTER 11 SECTION | | | 11-4.24.3 KNEE CLEARANCE. | | | 2. PLEASE ADD NOTES TO INTERIOR ELEVATION DETAIL 01; | | | DEPTH OF SINK 6 1/2" DEEP. SEC. 11-4.24.4.RAPP | | | EXPOSED PIPES UNDER SINK. SEC11-4.24.6. | | | AND TYPE OF HANDLES ON FAUCET TO COMPLY WITH SEC. | | | 11-4.24.7 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|