| Plan Review Stops For Permit 06110142 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-11 |
Time |
10:03 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2007-01-11 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-12 |
Time |
16:27 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-12-12 |
Time |
16:27 |
Sent To |
PC |
|
| Notes |
| 2006-12-12 16:42:09 | BUILDING PLAN REVIEW | | | PERMIT: 06110142 | | | ADD: 500 S AUSTRALIAN AV9TH FLOOR COMMON | | | CORRIDOR | | | CONT: KARL CORP CONSTRUCTION | | | TEL: (561)718-3799 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) 110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | *** 2004 EXISTING BUILDING CODE | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | PLANS INDICATEA TYPE II BUILDING, TYPE "A OR B" | | | DE)IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | | | | 3)PLEASE PROVIDE WALL AND CEILING CLASSIFICATION. | | | TABLE 803.5 REQUIRED BY OCCUPANCY | | | GENERAL. | | | INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED | | | IN ACCORDANCE WITH ASTM E 84. SUCH INTERIOR FINISH | | | MATERIALS SHALL BE GROUPED IN THE FOLLOWING CLASSES IN | | | ACCORDANCE WITH THEIR FLAME SPREAD AND SMOKE-DEVELOPED | | | INDEX. | | | CLASS A: | | | FLAME SPREAD INDEX 0-25; SMOKE-DEVELOPED INDEX 0-450. | | | CLASS B: | | | FLAME SPREAD INDEX 26-75; SMOKE-DEVELOPED INDEX 0-450. | | | | | | CLASS C: | | | FLAME SPREAD INDEX 76-200; SMOKE-DEVELOPED INDEX 0-450. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-12 |
Time |
16:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-01-12 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-07 |
Time |
08:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-11-07 |
Time |
06:40 |
Sent To |
I |
|
| Notes |
| 2006-11-07 08:09:00 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | 1}INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS FOR | | | DEVICES AND LIGHTING CIRCUITS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-01-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-16 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-16 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2007-01-16 12:45:30 | *****APPROVED***** | | | | | | | | | PLAN SHEETS E-1 AND FP-1 WERE STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-04 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-04 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2006-12-04 14:33:24 | ****DENIED***** | | | | | | | | | | | | 1. NFPA 101 - 2003 EDITION AND THE FLORIDA FIRE | | | PREVENTION CODE - 2004 EDITION SHALL BE REFERENCED. | | | | | | 2.CONSTRUCTION OPERATIONS SHALL NOT INTERFERE OR | | | HINDER EMERGENCY ACCESS TO THE SAID PROPERTY OR | | | VICINITY THEREOF | | | | | | 3.ON THE APPROPIATE ELEVATION DETAIL, SHOW/DISPLAY | | | THE NUMERICAL ADDRESS OF THIS BUILDING FRONTING MERRY | | | PLACE.AS PER WEST PALM BEACH CODE, THOSE NUMBERS | | | SHALL BE NO LESS THAN 6" IN HEIGHT AND 1" IN WIDTH. | | | INDIVIDUAL APARTMENT/UNIT SHALL BE NO LESS THAN 3" IN | | | HEIGHT. | | | | | | 4.THE ADDRESS OF THE STRUCTURE SHALL BE IN THE TITLE | | | BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 5.FIRE EXTINGUISHERS ARE TO BE 2A-10BC RATED. | | | | | | 6.AS PER NFPA 101 - 10.2.8.1 -2003 EDITION, | | | INTERIOR FINISH FOR WALLS AND CEILINGS IN AN | | | UNSPRINKLERED BUILDING SHALL BE CLASS "A" OR CLASS | | | "B". | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-22 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-22 |
Time |
11:56 |
Sent To |
M |
|
| Notes |
| 2007-03-22 11:57:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-28 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-28 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2007-01-09 14:25:30 | TO "BOB"#16 | | 2006-12-28 14:13:29 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-12 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-11-08 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2006-11-20 16:11:44 | TO "BOB"#2 | | 2006-11-08 16:52:11 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-28 |
Time |
10:01 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-03-28 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2007-03-28 10:02:22 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-10 |
Time |
13:49 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-01-10 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-05 |
Time |
15:45 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-12-05 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2006-12-05 15:51:25 | *** DENIED *** | | | 1) DUCTS PASSING THROUGH RATED WALLS AND OVER RATED | | | DOORS REQUIRE FIRE DAMPERS, SEE 2004 FBC/M 607.5.3. | | | | | | 2) 14" FLEX DUCT MAY NOT PASS THROUGH A FIRE RATED WALL | | | OR OVER A RATED DOOR, SEE 2004 FBC/M 607.7. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-09 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-09 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2006-12-09 08:51:20 | NO PLUMBING SHOWN ON DRAWINGS. |
|
|