| Plan Review Stops For Permit 06101134 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
jjohnsto |
Date |
2007-08-28 |
Time |
1630 |
Rev Time |
0.00 |
| Received By |
jjohnsto |
Date |
2007-08-28 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-05 |
Time |
16:15 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-07-05 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
| 2007-07-05 16:24:18 | BUILDING PLAN REVIEW | | | PERMIT: 06101134 | | | ADD: 717 S. OLIVE AVE | | | CONT: SUPERIOR POOL & SPAS | | | TEL: (954) 578-1011 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) COMPLIED. | | | | | | 3) COMPLIED. | | | | | | 4)COMPLIED. | | | | | | 5) COMPLIED. | | | | | | 6) 13-412.1.ABC.2.6.2 POOL COVERS. | | | HEATED POOLS SHALL BE EQUIPPED WITH A VAPOR RETARDANT | | | POOL COVER ON OR AT THE WATER SURFACE. POOLS HEATED TO | | | MORE THAN 90?F (32?C) SHALL HAVE A POOL COVER WITH A | | | MINIMUM INSULATION VALUE OF R -12. | | | EXCEPTION: POOLS DERIVING OVER 60 PERCENT OF THE ENERGY | | | FOR HEATING FROM SITE-RECOVERED ENERGY OR SOLAR ENERGY | | | SOURCE. | | | | | | 7)COMPLIED. | | | | | | 8) COMPLIED. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-21 |
Time |
08:11 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-11-21 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2006-11-21 09:05:54 | BUILDING PLAN REVIEW | | | PERMIT: 06101134 | | | ADD: 717 S. OLIVE AVE | | | CONT: SUPERIOR POOL & SPAS | | | TEL: (954) 578-1011 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | 2) DEPTH MARKINGS, THE PLAN DOES NOT MENTION THE | | | REQUIREMENTS FOR | | | DEPTH MARKINGS AS STATEDIN 424.1.2.3.1. (2). | | | | | | 3) PLANS ALSO FAIL TO MENTION THE SIZE OF THE STAIR | | | TREADS | | | NOR RISERS OR THE REQUIREMENTS FOR THE LEADING EDGE OF | | | THE STAIR TO BE DARK IN COLOR, CONTRASTING WITH THE | | | INTERIOR | | | OF THE INTERIOR OF THE POOL. 424.1.2.5.3. | | | | | | 4)SHEET 4 BENCHES FAIL TO PROVIDE THE DEPTH THAT THE | | | BENCHES WILL BE LOCATED AT? | | | ALSO NO MENTION TO THE CONTRASTING COLORED TILE ON THE | | | LEADING EDGE. | | | 424.1.2.6. OBSTRUCTIONS(2).UNDERWATER SEAT BENCHES | | | MAY BE INSTALLED IN AREAS LESS THAN 5 FEET (1524 MM) | | | DEEP. BENCH SEATS MUST BE 14 TO 18 INCHES (356 TO 457 | | | MM) WIDE AND MUST HAVE A DARK CONTRASTING MARKING ON | | | THE SEAT EDGE EXTENDING 2 INCHES (51 MM) ON THE | | | HORIZONTAL AND VERTICAL SURFACE. IF TILE IS USED IT | | | MUST BE SLIP RESISTANT, EXCEPT THAT BULLNOSE TILE MAY | | | BE SUBSTITUTED AND INSTALLED IN ACCORDANCE WITH SECTION | | | 424.1.2.5.3 . | | | | | | 5)SHEET 8 DOESN'T INDICATE A HOSE BIB WITH VACUUM | | | BREAKER IN THE EQUIPMENT ROOM OR AREA, 424.1.5.9. | | | | | | 6) 13-412.1.ABC.2.6.2 POOL COVERS. | | | HEATED POOLS SHALL BE EQUIPPED WITH A VAPOR RETARDANT | | | POOL COVER ON OR AT THE WATER SURFACE. POOLS HEATED TO | | | MORE THAN 90?F (32?C) SHALL HAVE A POOL COVER WITH A | | | MINIMUM INSULATION VALUE OF R -12. | | | EXCEPTION: POOLS DERIVING OVER 60 PERCENT OF THE ENERGY | | | FOR HEATING FROM SITE-RECOVERED ENERGY OR SOLAR ENERGY | | | SOURCE. | | | | | | 7) PLANS DO NOT SHOW AN ACCESSIBLE ROUTE TO THE POOL | | | DECK AND POOL, ONLY STAIRS ARE EVIDENT? PLEASE INDICATE | | | THE | | | ACCESSIBLE PATH? 11-4.1.2. | | | | | | 8) PERMIT FEES ARE TO BE PAID AT TIME OF | | | APPLICATION.!!! | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-01 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-01 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2007-08-01 16:27:43 | *** REDLINED PLANS*** | | | | | | A NOTE PLACED ON PLANS BELOW PANEL SCHEDULES ON SHEET 3 | | | OF 10 MENTIONS THAT THE PANELS ARE FED W/#6 CONDUCTORS | | | FED FROM TRANSFORMERS ETC. | | | THIS NOTE CAN NOT POSSIBLY APPLY TO THESE PLANS AS IT | | | DOES MATCH WITH BASE BUILDING PLANS OR EITHER OF THE | | | TWO PANEL(S) OR SCHEDULE(S) PROVIDED. | | | THIS NEEDS TO BE REVISED AT A LATE DATE BEFORE | | | INSPECTIONS FOR FINALS. | | | IF PLANS ARE RETURNED WITH COMMENTS FROM OTHER TRADES | | | PLEASE ADDRESS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-02 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-02 |
Time |
|
Sent To |
|
|
| Notes |
| 2007-07-05 16:52:59 | REVIEWED UNDER PERMIT #06100587 , PREVIOUS NOTES THE | | | SAME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-11 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-11 |
Time |
|
Sent To |
|
|
| Notes |
| 2007-07-05 16:53:53 | REVIEW DONE UNDER 06100587 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-27 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-27 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2007-05-03 08:45:48 | REVIEW DONE UNDER 06100587 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-08-21 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-08-21 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2007-08-21 11:14:30 | PLANS REVIEWED FOR COMPLIANCE WITH NEC BY ELECTRICAL | | | REVIEWER |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-06-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2007-06-14 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2007-06-14 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2007-06-14 11:16:35 | 1. THE ELECTRIC FOR THE POOL, SPA AND FOUNTAIN TO | | | COMPLY WITH THE APPROPRIATE SECTIONS OF THE NATIONAL | | | ELECTRICAL CODE. | | | | | | 2. THE ELECTRIC INSTALLATION SHALL MEET CODE AND BE | | | SAFE. | | | | | | MIKE CARSILLO, BATTALION CHIEF OF FIRE PREVENTION | | | 804-4709 PHONE | | | 804-4774 FAX | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-02 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-02 |
Time |
14:49 |
Sent To |
P |
|
| Notes |
| 2008-05-02 14:49:54 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-23 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-23 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2007-08-01 13:50:59 | TO "COMM" BD#18 | | 2007-07-23 14:54:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-24 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-24 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2007-05-02 13:30:30 | TO "COMM" BD#24 | | 2007-04-24 08:36:34 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-17 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-16 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2007-01-16 18:01:28 | TO "E" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-20 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-20 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2008-05-20 10:17:55 | SUBMITTAL APPROVED FOR COLLECTOR TANK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-31 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-31 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-09 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-09 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2007-06-09 06:50:29 | DENIED | | | REFERENCE: FBC-2004 CHAPTER 4 SECTION 424.1 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. SHT 7 OF 10. INDICATE THE LOCATION OF THE SPA JETS. | | | (6 INDICATED ON THE SCHEDULE). SECTION 106.1.1. | | | ****NO RESPONSE/NOT ADDRESSED | | | | | | 2. SHT 8 OF 10. INDICATE THE LOCATION OF THE HOSE BIBB | | | REQUIRED IN THE EQUIPMENT ROOM. SECTION 424.1.5.9. | | | ****NO RESPONSE/NOT ADDRESSED | | | | | | 3. SHT 8A OF 10. OVERFLOW FROM THE POOL AND SPA | | | COLLECTING TANKS SHALL CONNECT TO THE STORM SYSTEM, NOT | | | THE SANITARY. PLEASE INDICATE ON THE PLANS. | | | ****NO RESPONSE/NOT ADDRESSED | | | | | | 4. A SOLAR BLANKET WILL BE REQUIRED PER SECTION | | | 13-612.1.ABC.2.3.2. - MANUF. SPECIFICATION SHEETS DO | | | NOT INDICATE IF THE REQUIREMENT CAN BE EXEMPT FROM THIS | | | REQUIREMENT. (SEE SECTION BELOW). | | | | | | 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A | | | COVER DESIGNED TO MINIMIZE HEAT LOSS. | | | EXCEPTION : OUTDOOR POOLS DERIVING OVER 70 PERCENT OF | | | THE ENERGY FOR HEATING FROM NONDEPLETABLE ON | | | SITE-RECOVERED SOURCES COMPUTED OVER AN OPERATING | | | SEASON ARE EXEMPT FROM THIS REQUIREMENT. | | | ****NO RESPONSE/NOT ADDRESSED | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-12-07 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-12-07 |
Time |
11:07 |
Sent To |
Z |
|
| Notes |
| 2006-12-07 11:33:49 | DENIED | | | REFERENCE: FBC-2004 CHAPTER 4 SECTION 424.1 | | | | | | 1. SHT 7 OF 10. INDICATE THE LOCATION OF THE SPA JETS. | | | (6 INDICATED ON THE SCHEDULE). SECTION 106.1.1. | | | | | | 2. SHT 8 OF 10. INDICATE THE LOCATION OF THE HOSE BIBB | | | REQUIRED IN THE EQUIPMENT ROOM. SECTION 424.1.5.9. | | | | | | 3. SHT 8A OF 10. OVERFLOW FROM THE POOL AND SPA | | | COLLECTING TANKS SHALL CONNECT TO THE STORM SYSTEM, NOT | | | THE SANITARY. PLEASE INDICATE ON THE PLANS. | | | | | | 4. A SOLAR BLANKET WILL BE REQUIRED PER SECTION | | | 13-612.1.ABC.2.3.2. - MANUF. SPECIFICATION SHEETS DO | | | NOT INDICATE IF THE REQUIREMENT CAN BE EXEMPT FROM THIS | | | REQUIREMENT. (SEE SECTION BELOW). | | | | | | 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A | | | COVER DESIGNED TO MINIMIZE HEAT LOSS. | | | EXCEPTION : OUTDOOR POOLS DERIVING OVER 70 PERCENT OF | | | THE ENERGY FOR HEATING FROM NONDEPLETABLE ON | | | SITE-RECOVERED SOURCES COMPUTED OVER AN OPERATING | | | SEASON ARE EXEMPT FROM THIS REQUIREMENT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2007-08-03 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2007-08-03 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2007-08-03 13:59:12 | APPROVAL ONLY FOR POOL. LOCATION, LANDSCAPE AND GENERAL | | | DECK DESIGN SHALL FOLLOW APPROVAL ON MAIN BUILDING | | | PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-05-11 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2007-05-11 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2007-05-11 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2007-05-11 13:40:57 | PLEASE SEE A APONTE'S NOTES FROM PREVIOUS REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-08 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2007-01-08 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
AAPONTE |
Date |
2007-01-08 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2007-01-08 13:40:36 | 1. THE PERMIT ADDRESS IS WRONG. | | | 2. THE LOCATION MAP IS WRONG. | | | 3. SWIMMING POOLS SHALL BE SURROUNDED BY A MINIMUM | | | FIVE-FOOT WIDE WALKWAY. | | | 4. PLEASE PROVIDE A COPY OF THE ROOF TOP PLAN APPROVED | | | UNDER THE MAIN PERMIT. PLAN SHALL INCLUDE LANDSCAPE | | | AREAS AND COVERED STRUCTURES FOR REREFERENCE. |
|
|