| Plan Review Stops For Permit 06101122 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2009-01-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-01-08 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-01-08 |
Time |
16:09 |
Sent To |
PC |
|
| Notes |
| 2009-01-08 16:09:43 | REVISED RAS 117 CALCULATIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2008-12-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-12-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-12-29 |
Time |
11:07 |
Sent To |
PC |
|
| Notes |
| 2008-12-29 13:04:49 | BUILDING SUBMITTAL CHECKLIST: | | | | | | 1- ENGINEER'S NAIL ENHANCING LETTER SUBMITTED FOR | | | POLYGLASS MODIFIED BITUMEN ROOFING SYSTEM DOESN'T WORK | | | FOR ZONE #3. ENGINEER TO PROVIDE THE CALCULATED DESIGN | | | PRESSURES FOR ALL ZONES IN EXPOSURE "C" AS SPECIFIED ON | | | LETTER SUBMITTED. AND, PROVIDE ACTUAL RAS 117 | | | CALCULATIONS. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004 | | | TO VERIFY COMPLIANCE WITH RAS 117 CALCULATIONS AND | | | DESIGN PRESSURES OF SEC. R301 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | NOTE: ENGINEER TO REVIEW SEC. 8.1 OF RAS 117 FOR | | | MINIMUM FASTENER SEPARATION SPACING ALLOWED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2008-12-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-12-23 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-12-23 |
Time |
10:54 |
Sent To |
PC |
|
| Notes |
| 2008-12-23 10:55:02 | ROOFING REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-10-06 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-10-06 |
Time |
09:46 |
Sent To |
PC |
|
| Notes |
| 2008-10-06 10:05:29 | RESIDENTIAL (R3) REVISION BUILDING REVIEW THIRD | | | CHECKLIST: | | | | | | OLD COMMENT: | | | 1- STAIR DETAIL ON SHEET D-1 CALLS FOR 18 RISERS, WHILE | | | FLOOR PLANS SHOW 17 RISERS. REVISE AS REQUIRED TO MATCH | | | AND SHOW COMPLIANCE WITH SEC. R311.5.3.2 OF 2004 | | | FLORIDA RESIDENTIAL CODE. (REPEAT COMMENT). | | | | | | ***COMMENT BASED ON RESPONSE: | | | NOW STAIRS SHOW 19 RISERS WITH 7 3/4" RISERS AND 10" | | | TREADS. THIS STAIR RISER/TREAD RATION DOESN'T COMPLY | | | WITH SEC. R311.5.3.2 OF 2004 RESIDENTIAL CODE. REVISE | | | AS REQUIRED TO COMPLY WITH THIS CODE SECTION. | | | | | | OLD COMMENT: | | | 2- ENGINEER TO REVISE RAS 117 CALCULATIONS. (REPEAT | | | COMMENT). FASTENERS CAN'T BE SPACED LESS THAN 4"O.C.. | | | SEE SEC. 8.1 OF RAS 117. 2 ROWS IN THE LAP WILL HAVE | | | THE FASTENERS SPACED AT LESS THAN 4" O.C.. | | | PROVIDE CALCULATIONS SHOWING HOW THE 2 ROWS AT LAP AND | | | THE 3 ROWS IN THE CENTER OF THE SHEET WILL SATISFY THE | | | NAIL ENHANCEMENT CALCULATIONS TO RESIST THE | | | CALCULATED DESIGN PRESSURES. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | ***COMMENT BASED ON RESPONSE: | | | ENGINEER STILL SHOWS TWO ROWS AT THE LAP. THIS IS NOT | | | ALLOWED BECAUSE FASTENERS CAN'T BE SPACED LESS THAN | | | 4"O.C.. | | | IN ADDITION, ENGINEER'S RESPONSE IN WRITING IS NOT | | | CLEAR. PROVIDE DRAWING SHOWING THE NAILING SPACING AND | | | NUMBER OF ROWS. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004 TO VERIFY COMPLIANCE WITH CALCULATED DESIGN | | | PRESSURES OF SEC. R301 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | OLD COMMENT: | | | 3- PROVIDE COMPLETE PRODUCT APPROVAL REPORT. ONLY THE | | | PAGE 43 OF 44 WAS SUBMITTED. SUBMIT THE FRONT COVER | | | PAGES OF THE NOA , THE SHEET WHERE SELECTED ASSEMBLY IS | | | SHOWN AND THE LAST PAGE OF THE NOA WITH THE GENERAL | | | LIMITATIONS. | | | | | | ***COMMENT BASED ON RESPONSE: | | | INFORMATION WAS NOT PROVIDED AT ALL. | | | | | | 4- OWES $70.00. REVISION SUBMITTED HAS 9 DRAWINGS AND | | | ONE ENGINEER LETTER/PRODUCT APPROVAL. REVISION FEES ARE | | | $50.00 PLUS $10.00 PER PLAN/PAGE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-08-08 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-08-08 |
Time |
12:54 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 16:06:47 | RESIDENTIAL (R3) REVISION BUILDING REVIEW SECOND | | | CHECKLIST: | | | | | | 1- STAIR DETAIL ON SHEET D-1 CALLS FOR 18 RISERS, WHILE | | | FLOOR PLANS SHOW 17 RISERS. REVISE AS REQUIRED TO MATCH | | | AND SHOW COMPLIANCE WITH SEC. R311.5.3.2 OF 2004 | | | FLORIDA RESIDENTIAL CODE. (REPEAT COMMENT). | | | | | | 2- ENGINEER TO REVISE RAS 117 CALCULATIONS. (REPEAT | | | COMMENT). FASTENERS CAN'T BE SPACED LESS THAN 4"O.C.. | | | SEE SEC. 8.1 OF RAS 117. 2 ROWS IN THE LAP WILL HAVE | | | THE FASTENERS SPACED AT LESS THAN 4" O.C.. | | | PROVIDE CALCULATIONS SHOWING HOW THE 2 ROWS AT LAP AND | | | THE 3 ROWS IN THE CENTER OF THE SHEET WILL SATISFY THE | | | NAIL ENHANCEMENT CALCULATIONS TO RESIST THE | | | CALCULATED DESIGN PRESSURES. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | 3- PROVIDE COMPLETE PRODUCT APPROVAL REPORT. ONLY THE | | | PAGE 43 OF 44 WAS SUBMITTED. SUBMIT THE FRONT COVER | | | PAGES OF THE NOA , THE SHEET WHERE SELECTED ASSEMBLY IS | | | SHOWN AND THE LAST PAGE OF THE NOA WITH THE GENERAL | | | LIMITATIONS. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-24 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-24 |
Time |
16:57 |
Sent To |
PC |
|
| Notes |
| 2008-06-24 16:58:26 | RESIDENTIAL (R3) BUILDINGG REVIEWREVISION CHECKLIST: | | | | | | 1- PROVIDE SOIL TEST REPORT (2 COPIES) AFTER HOUSE AND | | | POOL ARE REMOVED. ENGINEER OF RECORD TO REVIEW SOIL | | | TEST REPORT TO VERIFY IF SOILS WILL MEET HIS DESIGN | | | CRITERIA PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 2- IF BBQ GRILL IS NOT GOING TO BE INSTALLED, THEN, | | | REVISE ORIGINAL DRAWINGS. | | | | | | 3- PROVIDE CLEAR DETAILS AND SPECS FOR STAIRS TO SHOW | | | COMPLIANCE WITH WINDERS DIMENSIONS OF SEC. R311.5.3.2 | | | OF 2004 FLORIDA RESIDENTIAL CODE AND LIVE LOADS AS | | | REQUIRED BY TABLE R301.5. (REPEAT COMMENT). PROVIDE | | | DETAILS WITHWRITTEN DIMENSIONS. ALSO,FLOOR PLANS | | | SHOW 17 RISERS, WHILE STAIR SECTIONCALLS FOR 18 | | | RISERS.REVISE AS REQUIRED,ALSO, STAIRS ON 2ND FLOOR | | | PLAN ARE SHOWN AS DOTTED LINES INSTEAD OF SOLID LINES. | | | REVISE AS REQUIRED. | | | | | | REVISE SPECIFICATIONS FOR RAILING PICKETS AND MINIMUM | | | TREAD SIZES SHOWN ON TYPICAL STAIR DETAIL ON SHEET D-1. | | | SEE COMMENTS ON REVIEWED SET.EG: SPECS FOR PICKET | | | SPACING SAYS THAT 4" SPHERE MAY PASS THRU INSTEAD OF | | | MAY NOT PASS THRU.AND, SPECS FOR MINIMUM TREAD SIZE | | | ARE NOT CLEAR. REVISE AS REQUIRED. | | | | | | 4- SURVEY TO HAVE ORIGINAL SIGNATURE, NOT COPY AS | | | REQUIRED BY SEC. 61G17-7.0025 FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | 5-ENGINEER TO REVISE RAS 117 CALCULATIONS. | | | FASTENERS CAN'T BE SPACED LESS THAN 4". O.C..SEE SEC. | | | 8.1 OF RAS 117 AND REVISE AS REQUIRED. | | | | | | 6-ENERGY CALCULATIONS: | | | A) REVISE CEILING INSULATION R-VALUE TO MATCH PLANS. | | | NEED R-30. SEE PLANS. | | | | | | B) PROVIDE COMPLETE ENERGY CALCULATIONS. ONLY 2 | | | SHEETS WERE SUBMITTED. | | | | | | 7- ENGINEER NEEDS TO REVISE DESIGN CRITERIA.ACCORDING | | | TO SEC. R301.2.1.4(3) THIS BUILDING IS CONSIDERED TO BE | | | EXPOSURE "C", NOT "B".REVISEINFORMATION ON SHEET | | | S-2 AND WHERE THE DESIGN PRESSURES FOR OPENINGS ARE | | | PROVIDED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-03-13 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-03-13 |
Time |
10:06 |
Sent To |
PC |
|
| Notes |
| 2008-03-13 10:17:31 | IMPACT FEES PAID AND NOC RE-RECORDED. | | | ***NOTE: SEE PROVISO DATED 2-5-08. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-02-05 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-02-05 |
Time |
13:09 |
Sent To |
PC |
|
| Notes |
| 2008-02-05 13:50:08 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- REVISE SOIL TEST REPORT TO REFLECT REVISED PROPOSED | | | SCOPE OF WORK. | | | 2- PROVIDE MANUFACTURER SPECS FOR BBQ GRILL TO BE | | | INSTALLED IN PORCH.PAGE III OF SPECSSUBMITTED DON'T | | | ALLOWBBQ GRILL ON PORCH. | | | 3- PROVIDE CLEAR DETAILS AND SPECS FOR STAIRS TO SHOW | | | COMPLIANCE WITH WINDERS DIMENSIONS OF SEC. R311.5.3.2 | | | OF 2004 FLORIDA RESIDENTIAL CODE AND LIVE LOADS AS | | | REQUIRED BY TABLE R301.5. | | | ALSO, REVISE CODE REFERENCES SHOWN ON TYPICAL STAIR | | | DETAIL ON SHEET D-1. SEE SEC. R311.5 OF 2004 FLORIDA | | | RESIDENTIAL CODE FOR PROPER CODE SECTIONS TO BE | | | REFERENCED. | | | 4- SPECIFY DRAFSTOPPING ON SECOND FLOOR PLANAS | | | REQUIRED BY SEC. R502.1.2 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | 5- THIS PROPERTY IS LOCATED ON FLOOD ZONE "C", NOT "B". | | | REVISE SURVEY AS REQUIRED. | | | 6- PROVIDE COMPLETE WALL SECTION THRU BALCONY | | | PROVIDINGCOMPLETE SPECSFOR FLOOR (INCLUDING BALCONY | | | DECK)AND CEILINGS AS REQ'DBY SEC. 106.3.5.4 OF CITY | | | AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH SEC. | | | R301 OF 2004FLORIDA RESIDENTIAL CODE. | | | 7- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | | PERIMETER AND CORNER AREAS FOR POLYGLASS MODIFIED | | | BITUMEN AS REQ'DBY GENERAL LIMITATION #7.SEE | | | GENERAL LIMITATION #7 TO SEE WHO CAN PREPARE SUCH | | | CALCULATIONS. | | | 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) PRODUCT APPROVAL FOR | | | POLYGLASS MODIFIED BITUMEN AS REQ'DBY SEC. 106.3.3 | | | CITY AMENDMENTS TO FBC 2004. | | | 9- REVISE TYPO ON ENERGY CALCULATIONS ITEM 9(B).THERE | | | IS NOT INSULATION R-219. | | | | | | ***NOTE: PROVIDE ABOVE INFORMATION PRIOR TO INSPECTIONS | | | TO AVOID CONFLICTS ORDELAYS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-24 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-24 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2007-09-24 09:14:21 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB | | | FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | | | | COMMENTS FROM PREVIOUS LISTS: | | | | | | 1.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO | | | PERMIT PICKUP, FS713.13. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY | | | PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD.THE PLANS | | | MUST BE STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.PLEASE CALL 561-233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.)INCLUDE FBC EB IN GOVERNING CODE.DECLARE LEVEL | | | OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 4.-12.)ADDRESSED. | | | | | | 13.)PROVIDE A SOILS INVESTIGATION REPORT, FBC | | | R401.4. | | | | | | 2ND REVIEW - THIS WAS NOT SUBMITTED.THE SOILS REPORT | | | SHOULD ALSO ADDRESS THE EXISTING POOL AREA. | | | 3RD REVIEW - EITHER STRUCTURAL ENGINEER OR SOILS | | | ENGINEER IS TO ADDRESS THE ISSUE OF BUILDING OVER THE | | | EXISTING POOL.THE SOILS REPORT SUBMITTED IS FOR A 2 | | | STORY ADDITION AND WAS DONE IN 2005.PLEASE REVISE TO | | | REFLECT CURRENT SCOPE OF WORK. | | | | | | 14-23.)ADDRESSED. | | | | | | NEW COMMENT: | | | | | | FOR THE ROOF PRODUCT APPROVAL FL6568, PLEASE MARK THE | | | METHOD OF ATTACHMENT YOU ARE USING.YOU MAY SPECIFY | | | DIFFERENT METHODS FOR EACH ZONE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-09 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-05 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2007-07-09 17:04:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB | | | FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO | | | PERMIT PICKUP, FS713.13. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY | | | PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD.THE PLANS | | | MUST BE STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.PLEASE CALL 561-233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.)INCLUDE FBC EB IN GOVERNING CODE.DECLARE LEVEL | | | OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 4.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER | | | OF RECORD, FBC*106.3.3. | | | | | | 2ND REVIEW - THIS MAY BE DONE WITH A SHOP DRAWING | | | REVIEW STAMP OR A LETTER. | | | | | | 5.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | | IN ADDITION TO THE NOAS SUBMITTED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG.THE FLORIDA STATE PRODUCT | | | APPROVALS PROVIDED ARE EXPIRED; FBC2001 RATHER THAN | | | FBC2004.PLEASE PRINT CURRENT APPROVALS. | | | | | | 2001 APPROVALS WERE SUBMITTED FOR PGT PW701, WINDSOR | | | DOOR (2004 REQUIRED).NONE PROVIDED FOR THE PGT | | | MULLION. | | | | | | 6.)ADDRESSED. | | | | | | 7.)SHOW REQUIRED HEAD CLEARANCE FOR THE ATTIC ACCESS, | | | R807.IT DOES NOT APPEAR TO BE COMPLIANT IN THIS | | | LOCATION. | | | | | | 2ND REVIEW -IT IS NOT CLEAR HOW THIS WAS ADDRESSED. | | | | | | 8-10.)ADDRESSED. | | | | | | 11.)SHOW DRAINAGE TO COMPLY WITH FBC R401. | | | | | | 12.)DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 13.)PROVIDE A SOILS INVESTIGATION REPORT, FBC | | | R401.4. | | | | | | 2ND REVIEW - THIS WAS NOT SUBMITTED.THE SOILS REPORT | | | SHOULD ALSO ADDRESS THE EXISTING POOL AREA. | | | | | | 14-15.)ADDRESSED. | | | | | | 16.)DOES THE GARAGE DOOR HAVE GLAZING?NOTE THAT | | | GLAZING IS AN OPTION ON THE PRODUCT APPROVAL SUBMITTED | | | BUT REQUIRES IMPACT PROTECTION. | | | | | | THIS MAY BE ADDRESSED BY WRITING "NO GLAZING" ON THE | | | PRODUCT APPROVAL.IF YOU ARE USING THE GLAZING OPTION, | | | IMPACT PROTECTION REQUIRED (WITH PRODUCT APPROVALS AND | | | ATTACHED INSTALLATION SCHEDULE COMPLETED). | | | | | | 17.)ADDRESSED. | | | | | | 18.)CHANGES TO THE PLAN MUST BE DONE BY THE DESIGNER | | | OF RECORD, CLOUDED, INITIALLED AND DATED.REVISIONS | | | WERE DONE ON A1 AND A3 APPARENTLY BY SOMEONE OTHER THAN | | | THE ENGINEER. | | | | | | 2ND REVIEW - CHANGES WERE NOT CLOUDED.THIS REQUIRES | | | AN ENTIRELY NEW PLAN REVIEW AND WILL CAUSE DELAYS. ALL | | | REVISIONS/CHANGES TO THE PLAN ARE TO BE CLOUDED AND | | | NUMBERED. | | | | | | 19.)ELEVATIONS ON A1 SHOULD NOTE EXISTING AND | | | ADDITION AREAS. | | | | | | 20.)THE ADDING STRAP DETAIL S2 DOES NOT COMPLY WITH | | | THE SIMPSON CATALOG.ADDRESS.CHECK ALL CONNECTORS. | | | | | | 21.)SHEET D-2, HIB-91 HAS BEEN REPLACED BY TPI/WTCA | | | BCSI 1-03.CHECK ALL REFERENCES.FOR INSTANCE, | | | CONCRETE NOTE REFERS TO ACI 544.1R-82.THERE ARE OTHER | | | EXPIRED REFERENCES.SEE FBC35. | | | | | | 22.)GARAGE/RESIDENCE SEPARATION TO COMPLY WITH FBC | | | R309. | | | | | | NEW COMMENT: | | | | | | 23.)SEE ATTACHED FS553.80(2)9B). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-05 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-05 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2007-01-05 16:28:39 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | | | | 1.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO | | | PERMIT PICKUP, FS713.13. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY | | | PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD.THE PLANS | | | MUST BE STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.PLEASE CALL 561-233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.)INCLUDE FBC EB IN GOVERNING CODE.DECLARE LEVEL | | | OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 4.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER | | | OF RECORD, FBC*106.3.3. | | | | | | 5.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | | IN ADDITION TO THE NOAS SUBMITTED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG.THE FLORIDA STATE PRODUCT | | | APPROVALS PROVIDED ARE EXPIRED; FBC2001 RATHER THAN | | | FBC2004.PLEASE PRINT CURRENT APPROVALS. | | | | | | 6.)PROVIDE AREA CALCULATIONS ON THE PLAN; EXISTING, | | | PROPOSED, NEW TOTALS FOR CONDITIONED AND UNCONDITIONED | | | SPACE. | | | | | | 7.)SHOW REQUIRED HEAD CLEARANCE FOR THE ATTIC ACCESS, | | | R807.IT DOES NOT APPEAR TO BE COMPLIANT IN THIS | | | LOCATION. | | | | | | 8.)SMOKE DETECTORS REQUIRED FBC R313. | | | | | | 9.)SHOW REQUIRED SAFETY GLAZING FBCR308.4. | | | | | | 10.)SPECIFY WINDOW SIZE AND TYPE FOR REQUIRED | | | EMERGENCY EGRESS, FBC R310. | | | | | | 11.)SHOW DRAINAGE TO COMPLY WITH FBC R401. | | | | | | 12.)DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 13.)PROVIDE A SOILS INVESTIGATION REPORT, FBC | | | R401.4. | | | | | | 14.)PROVIDE A SITE PLAN SHOWING THE EXISTING HOUSE | | | AND THE PROPOSED ADDITION, FBC*106.3.5. | | | | | | 15.)SIGN THE OWNER/AGENT LINE OF THE ENERGY CALCS, | | | FBC13. | | | | | | 16.)DOES THE GARAGE DOOR HAVE GLAZING?NOTE THAT | | | GLAZING IS AN OPTION ON THE PRODUCT APPROVAL SUBMITTED | | | BUT REQUIRES IMPACT PROTECTION. | | | | | | 17.)PROVIDE INFORMATION IN REGARDS TO FASTENING FOR | | | THE IMPACT PROTECTION.PROVIDE A KEY PLAN WITH | | | INFORMATION FOR EACH OPENING.SEE ATTACHED FORM FOR A | | | SUGGESTED FORMAT.IF ALL INFORMATION IS NOT PROVIDED | | | PRIOR TO PERMIT ISSUANCE, A SEPARATE PERMIT WILL BE | | | REQUIRED FOR THE SHUTTERS. | | | | | | 18.)CHANGES TO THE PLAN MUST BE DONE BY THE DESIGNER | | | OF RECORD, CLOUDED, INITIALLED AND DATED.REVISIONS | | | WERE DONE ON A1 AND A3 APPARENTLY BY SOMEONE OTHER THAN | | | THE ENGINEER. | | | | | | 19.)ELEVATIONS ON A1 SHOULD NOTE EXISTING AND | | | ADDITION AREAS. | | | | | | 20.)THE ADDING STRAP DETAIL S2 DOES NOT COMPLY WITH | | | THE SIMPSON CATALOG.ADDRESS.CHECK ALL CONNECTORS. | | | | | | 21.)SHEET D-2, HIB-91 HAS BEEN REPLQCED BY TPI/WTCA | | | BCSI 1-03.CHECK ALL REFERENCES.FOR INSTANCE, | | | CONCRETE NOTE REFERS TO ACI 544.1R-82.THERE ARE OTHER | | | EXPIRED REFERENCES.SEE FBC35. | | | | | | 22.)GARAGE/RESIDENCE SEPARATION TO COMPLY WITH FBC | | | R309. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-12-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-29 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-12-29 |
Time |
09:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-06 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-06 |
Time |
16:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
N |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-19 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-16 |
Time |
16:44 |
Sent To |
M |
|
| Notes |
| 2008-06-19 17:06:28 | | | | | | | ONE ELECTRICAL PLAN SUBMITTED IN ERROR, NO ELECTRICAL | | | CHANGESPER JULIE MONDELL./WRT | | 2008-06-16 16:45:18 | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-09 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-09 |
Time |
13:11 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-16 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-16 |
Time |
06:42 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-04 |
Time |
08:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-06-04 |
Time |
07:28 |
Sent To |
M |
|
| Notes |
| 2007-06-04 08:09:12 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | | | THE PLAN RESUBMITTED FOR REVIEW IS NOT THE SAME FLOOR | | | PLAN AS PREVIOUSLY REVIEWED, SEE "OLD SET". | | | | | | 1} THE OVEN AND DRYER CIRCUITS BOTH HAVE INCORRECTLY | | | SIZED OVERCURRENT PROTECTION ON THE PANEL SCHEDULE, | | | CIRCUITS 11,13 AN D15,17. ARTICLE 240. | | | | | | 2} LOCATE THE METER AND MAIN DISCONNECT AND ALL SERVICE | | | EQUIPMENT, ON THE PLAN, SHEET E-1. | | | | | | 3} RECEPTACLES MUST BE ADDED TO THE ISLAND (KTTCHEN) | | | FOR REQUIRED SPACING PER 210.52(C), | | | | | | 4} THE WALL BETWEEN THE MASTER BATH AND THE GREAT ROOM | | | IS MISSING, SHEET E-1. | | | | | | 5} A GFI PROTCTED RECEPTACLE IS REQUIRED AT THE BACK OF | | | THE DWELLING PER 210.52(E), 2108(A)(3). | | | | | | 6} RECEPTACLES MUST BE ADDED TO COMPLY WITH 210.52 IN | | | THE DINING ROOM, BEDROOMS #2 AND #3, AND THE MASTER | | | BEDROOM. SEE REVIEWED PLAN. | | | | | | 7} THE NOTE UNDER THE RISER DIAGRAM AND NOTE #6, | | | ELECTRICAL NOTES,REGARDING SMOKE ALARM CIRCUITS, | | | SHOULD INDICATE ARC FAULT CIRCUITS REQUIRED. | | | | | | 8} THERE ARE 3 GARAGE DOOR OPENERS IN THE LOAD | | | CALCULATION, AND ONLY 1 ON THE PANEL SCHEDULE AND IN | | | THE GARAGE.PLEASE CORRELATE. | | | | | | 9} PROVIDE A PANEL SCHEDULE FOR THE 400 AMP MAIN. IT | | | INDICATES A 400 AMP MAIN AND 2-200 AMP BREAKERS BUT IS | | | AN 8 CIRCUIT PANEL. PROVIDE THE AIC RATING ALSO.110.9. | | | | | | PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH | | | CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM | | | SEPARATELY TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-16 |
Time |
16:42 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-11-16 |
Time |
14:53 |
Sent To |
M |
|
| Notes |
| 2006-11-16 16:42:11 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE OVEN AND DRYER CIRCUITS BOTH HAVE INCORRECTLY | | | SIZED OVERCURRENT PROTECTION ON THE PANEL SCHEDULE, | | | CIRCUITS 11,13 AN D15,17. ARTICLE 240. | | | | | | 2} LOCATE THE METER AND MAIN DISCONNECT ON THE PLAN, | | | SHEET E-1. | | | | | | 3} NOTE #1 REFERS TO "IAW" PLEASE NOTE THAT THE STATE | | | OF FLORIDA HAS ADOPTED NFPA 70 OR THE NEC. REMOVE THE | | | REFERENCE. | | | | | | 4} SMOKE DETECTORS MUST BE INSTALLED TO COMPLY WITH | | | R313.1 RESIDENTIAL FLORIDA BUILDING CODE. | | | | | | 5} THE GARAGE RECEPTACLES ARE REQUIRED TO BE GFI | | | PROTECTED PER 210.8(A)(2). | | | | | | 6} RECEPTACLES MUST BE ADDED TO THE KITCHEN COUNTER | | | TOPS FOR REQUIRED SPACING PER 210.52(C),(INCLUDING | | | THE ISLAND). | | | | | | 7} THE BATHROOM OFF BEDROOM #2 AN DBEDROOM #3 MUST HAVE | | | OUTLETS SPACED PER 210.52(D), AND GFI PROTECTED PER | | | 210.8(A)(1). | | | | | | 8} A GFI PROTCTED RECEPTACLE IS REQUIRED AT THE BACK OF | | | THE DWELLING PER 210.52(E), 2108(A)(3). | | | | | | THERE ARE RECEPTACLES PLACED OFF THE WALL IN THE DINING | | | ROOM AND IN THE WALL AT TEH STORAGE CLOSET. PLEASE | | | LOCATE WHERE INTENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2009-05-19 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-05-19 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-05-14 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2009-05-14 17:03:18 | DRIVEWAY DRAWINGS SENT TO ZONING BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2009-01-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-08 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-08 |
Time |
08:32 |
Sent To |
B |
|
| Notes |
| 2009-01-08 08:33:24 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-12-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-30 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-30 |
Time |
14:08 |
Sent To |
M |
|
| Notes |
| 2008-12-30 14:10:08 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-22 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-22 |
Time |
11:17 |
Sent To |
B |
|
| Notes |
| 2008-12-22 11:17:50 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-12-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-18 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-18 |
Time |
08:21 |
Sent To |
M |
|
| Notes |
| 2008-12-18 08:21:26 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-15 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-15 |
Time |
10:49 |
Sent To |
E |
|
| Notes |
| 2008-12-15 10:50:02 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-03 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-03 |
Time |
16:25 |
Sent To |
B |
|
| Notes |
| 2008-10-03 16:25:37 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-01 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-01 |
Time |
09:02 |
Sent To |
E |
|
| Notes |
| 2008-08-01 09:03:00 | TO "BTROBUAG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-06-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-12 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-12 |
Time |
08:52 |
Sent To |
E |
|
| Notes |
| 2008-06-12 08:53:17 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-05 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-05 |
Time |
14:51 |
Sent To |
B |
|
| Notes |
| 2008-03-05 14:52:11 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-07 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-07 |
Time |
16:58 |
Sent To |
Z |
|
| Notes |
| 2008-01-07 16:59:02 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-08-08 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-08-08 |
Time |
18:58 |
Sent To |
Z |
|
| Notes |
| 2007-08-08 18:58:39 | SENT TO ZONING BOX MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-01 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-01 |
Time |
08:24 |
Sent To |
E |
|
| Notes |
| 2007-06-01 08:24:39 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-24 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-24 |
Time |
14:36 |
Sent To |
Z |
|
| Notes |
| 2007-05-24 14:36:52 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-08 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-08 |
Time |
13:27 |
Sent To |
E |
|
| Notes |
| 2006-11-08 13:27:14 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-05 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-01 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2006-11-01 08:47:08 | TO "Z" BOX |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-07-21 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-07-21 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-07-21 |
Time |
12:05 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2009-01-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-01-10 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-01-10 |
Time |
12:19 |
Sent To |
PC |
|
| Notes |
| 2009-01-10 12:20:05 | MECH A2 REVISION OK. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
F |
Date |
2008-12-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-20 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-20 |
Time |
13:51 |
Sent To |
PC |
|
| Notes |
| 2008-12-20 13:52:08 | | | | ACTION: DENIED | | | | | | REVIEWED FOR COMPLIANCE WITH THE FOLLOWING: | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | TWO COPIES OF REVISED "A-2" WERE SUBMITTED FOR REVIEW. | | | A REVIEW OF THESE PLANS CAN NOT BE COMPLETED AT THIS | | | TIME FOR THE FOLLOWING REASONS: | | | | | | 1. THE TWO COPIES SHOW DUCT DESIGNS WHICH DO NOT MATCH. | | | EXAMPLE: ONE COPY SHOWS TWO SUPPLY DROPS IN THE KITCHEN | | | WHILE THE OTHER COPY SHOWS NONE. EXAMPLE: THE HALF-BATH | | | NEAR BEDROOM #3 SHOWS AN EXHAUST FAN ON ONE COPY BUT | | | NOT THE OTHER. THESE ARE GIVEN AS EXAMPLES AND ARE NOT | | | INTENDED TO BE AN EXHAUSTIVE LIST. CHECK ALL ASPECTS OF | | | BOTH COPIES AND MAKE NECESSARY CORRECTIONS PRIOR TO | | | RESUBMITTING (PERHAPS DRAWING THE PLAN ONCE AND COPYING | | | IT RATHER THAN DRAWING IT TWICE WILL RESOLVE THIS | | | PROBLEM). PLEASE PROVIDED TWO IDENTICAL PLANS SO ONE | | | CAN BE INCORPORATED INTO THE PERMIT SET OF PLANS AND | | | THE OTHER CAN BE USED IN THE FIELD FOR INSPECTIONS. | | | FBCB 106.1.3. | | | | | | 2. SEVERAL DUCTS ARE MISSING SIZES ON PLANS. THIS | | | CONDITION VARIES FROM ONE PLAN TO THE OTHER. PLEASE | | | PROVIDED TWO IDENTICAL PLANS SO ONE CAN BE INCORPORATED | | | INTO THE PERMIT SET OF PLANS AND THE OTHER CAN BE USED | | | IN THE FIELD FOR INSPECTIONS. FBCB 106.1.3. | | | | | | 3. SOME OF THE DUCT SIZES ARE NOT LEGIBLE. PROVIDE | | | PLANS OF SUFFICIENT CLARITY TO DESCRIBE THE SCOPE AND | | | NATURE OF WORK PROPOSED IN ACCORDANCE WITH FBCB | | | 106.1.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-07 |
Time |
08:37 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-08-07 |
Time |
08:37 |
Sent To |
B |
|
| Notes |
| 2008-08-07 08:40:24 | REVISION TO ENERGY CALCULATIONS AND COOLING LOAD | | | CAL'S. | | | | | | NOTICE: MECHANICAL PLANS WILL NEED TO BE REVISED BEFORE | | | ROUGH MECHANICAL INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2008-06-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-20 |
Time |
15:54 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2008-06-20 |
Time |
15:53 |
Sent To |
B |
|
| Notes |
| 2008-06-20 16:05:12 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO ENERGY CALCULATIONS | | | *** DENIED *** | | | 1) PLEASE SUBMIT THE COMPLETE SET OF THE REVISED ENERGY | | | CALCULATIONS, PER 2004 FBC 13-600.3.A. | | | | | | 2) PLEASE SUBMIT REVISED COOLING LOAD CALCULATIONS WITH | | | THE THREE ZONES SERVED BY EACH SYSTEM NOW THAT THREE | | | SYSTEMS ARE BEING INSTALLED, PER 2004 FBC | | | 13-607.1.ABC.1 AND 13-600.3.ABC.2. | | | | | | 3) NOTICE: THE MECHANICAL PLANS WILL NEED TO BE REVISED | | | BEFORE A MECHANICAL INSPECTION. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-01-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-16 |
Time |
08:35 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-01-16 |
Time |
08:35 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-09 |
Time |
15:26 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2008-01-09 |
Time |
15:26 |
Sent To |
P |
|
| Notes |
| 2008-01-09 15:49:05 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) COULD NOT FIND A/C SYSTEM 1 & 2 IN THE ARI DIRECTORY | | | WEB-SITE, PLEASE SUBMIT THE ARI REFERENCE NUMBER OR | | | CERTIFICATE, SEE 2004 FBC 13-607.1.ABC.3.1.1. | | | | | | 2) PLEASE SHOW AND SIZE THE SUPPLY AIR DUCT (FLEX) TO | | | THE 10"X10" SUPPLY AIR GRILL IN THE KITCHEN, SEE 2004 | | | WPB AMEND. 106.3.5.4 (10). | | | | | | 3) PLEASE LABEL THE CONDENSER UNITS 1, 2, & 3 ON THE | | | MECHANICAL PLAN. | | | | | | 4) AS BOTH AIR HANDLER UNITS ARE FEEDING THE SAME | | | SUPPLY AND RETURN AIR DUCTS, PLEASE SUBMIT DETAILED | | | MANUFACTURER'S SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS TO SUPPORT THIS DESIGN OR IF AN | | | ENGINEERING SYSTEM, PLEASE SUBMIT THE COMPLETE | | | ENGINEERING SIGNED AND SEALED BY THE ENGINEER, SEE 2004 | | | FBC/R M1401.1. AND WPB AMEND. 106.1.2. | | | | | | 5) PLEASE SUBMIT MANUAL D CALCULATIONS TO SUPPORT THIS | | | DESIGN, SEE 2004 FBC/R M1601.1. | | | | | | 6) THE MECHANICAL PLANS NEED THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN ON | | | THEM, SEE W.P.B. AMEND. 106.1.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-16 |
Time |
08:33 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2007-08-16 |
Time |
08:33 |
Sent To |
P |
|
| Notes |
| 2007-08-16 09:09:26 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | | | *** DENIED *** | | | 1) MECHANICAL PLANS NEED THE JOB ADDRESS, AND THE | | | INFORMATION OF THE PERSON RESPONSIBLE FOR THE DESIGN ON | | | THEM. SEE WPB AMEND. 106.1.3. | | | | | | 2) MECHANICAL PLAN EQUIPMENT SUMMARY NEEDS THE TOTAL | | | AND SENSIBLE BTU'S FOR THE SYSTEMS IN IT. | | | | | | 3) NEED TO SIZE ALL THE RETURN AIR GRILLS ON THE | | | MECHANICAL PLAN. | | | | | | 4) THE 10X8" SUPPLY AIR GRILL IN BEDROOM #3 HAS TWO 7" | | | SUPPLY AIR DUCTS GOING TO IT. PLEASE CORRECT. | | | | | | 5) SHOW THE LOCATION OF THE CLOTHES DRYER VENT AND WERE | | | IT WILL TERMINATE AT ON MECHANICAL PLAN, SEE FBC RES. M | | | 501.2. | | | | | | 6) PROVIDE COMBUSTION AIR CALCULATIONS FOR GAS CLOSE | | | DRYER AND COMBUSTION AIR TO LAUNDRY ROOM IF REQUIRED, | | | SEE FBC RES. G2407.1. | | | | | | 7) ELECTRICAL PLAN SHOWS THE TWO A/C CONDENSER UNITS | | | SIDE BY SIDE, THE MECHANICAL PLAN SHOWS THEM AT | | | DIFFERENT SIDES OF THE HOUSE, THE PLANS MUST COINCIDE | | | PLEASE CORRECT. | | | | | | 8) SUBMIT DETAILED MANUFACTURER'S SPECIFICATION'S AND | | | INSTALLATION INSTRUCTIONS FOR THE GAS COOK-TOP IN THE | | | LANAI AS IT MAY REQUIRE AN APPROVED EXHAUST HOOD, SEE | | | FBC RES. M1504.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL: [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-08 |
Time |
09:44 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-06-08 |
Time |
09:43 |
Sent To |
P |
|
| Notes |
| 2007-06-08 09:52:22 | *** DENIED *** | | | ** ALL OF THE BELOW CORRECTIONS WERE REQUESTED IN THE | | | LAST REVIEW 11-20-07 AND STILL NEED TO BE CORRECTED.** | | | | | | 1) MECHANICAL PLAN ARE DIFFICULT TO READ THEIR IS TO | | | MUCH FLOOR PLAN DETAIL ON THEM. CONSTRUCTION DOCUMENTS | | | SHALL BE OF SUFFICIENT CLARITY. PLEASE SUBMIT BETTER | | | MECHANICAL PLANS. PER 2004 FBC 106.1.1. | | | . | | | 2) THE MECHANICAL PLANS NEED TO BE SEALED BY THE | | | ENGINEER JOHN M. AVERKAMP AS HIS NAME AND INFORMATION | | | IS IN THE TITLE BLOCK, PER FAC 61G15-23.002 . | | | | | | 3) PLEASE SHOW AN EQUIPMENT LISTING WITH ALL PERTINENT | | | INFORMATION ON THE MECHANICAL PLANS. | | | | | | 4) WAS NOTE 6, NEED ATTIC ACCESS WITH-IN 6 FEET OF AHU | | | #1, PER 2004 FBC/R M1305.1.3, PLEASE SHOW ACCESS ON | | | MECHANICAL AND BUILDING PLANS. | | | | | | 5) WAS NOTE 7, PLEASE SHOW ON MECHANICAL PLANS THE | | | LOCATION OF THE A/C CONDENSER UNITS, AND BATHROOM | | | EXHAUST FANS. | | | | | | 6) SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR | | | TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-20 |
Time |
09:19 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-20 |
Time |
15:41 |
Sent To |
B |
|
| Notes |
| 2006-11-20 15:58:31 | *** DENIED *** | | | 1) MECHANICAL PLAN ARE DIFFICULT TO READ. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY. PER 2004 FBC | | | 106.1.1. | | | . | | | 2) THE MECHANICAL PLANS NEED TO BE SEALED BY THE | | | ENGINEER JOHN M. AVERKAMP AS HIS NAME AND INFORMATION | | | IS IN THE TITLE BLOCK, PER FAC 61G15-23.002 . | | | | | | 3) PLEASE SHOW AN EQUIPMENT LISTING WITH ALL PERTINENT | | | INFORMATION ON THE MECHANICAL PLANS. | | | | | | 4) PLANS SHOW 3,061 SQUARE FEET UNDER AIR, ENERGY | | | CAL'S. AND MANUAL J CAL'S. SHOW 3,361 SQUARE FEET UNDER | | | AIR THE TWO MUST COINCIDE, PLEASE CORRECT ENERGY CAL'S. | | | AND MANUAL J CAL'S. | | | | | | 5) ONE 8" SUPPLY AIR DUCT IS GOING OUT-SIDE TO THE | | | COVERED PATIO KITCHEN, PLEASE CORRECT. | | | | | | 6) NEED ATTIC ACCESS WITH-IN 6 FEET OF AHU #1, PER 2004 | | | FBC/R M1305.1.3, PLEASE SHOW ACCESS ON MECHANICAL AND | | | BUILDING PLANS. | | | | | | 7) PLEASE SHOW ON MECHANICAL PLANS THE LOCATION OF THE | | | A/C CONDENSER UNITS, AND BATHROOM EXHAUST FANS. | | | | | | 8) PLEASE SUBMIT A COMPLETE MANUAL J CALCULATION, PER | | | 2004 FBC 13-607.1.ABC.1. NOT JUST A SUMMARY PAGE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-11 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-11 |
Time |
07:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-09-12 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-09-12 |
Time |
07:49 |
Sent To |
B |
|
| Notes |
| 2007-09-12 07:51:21 | DENIED; | | | SANITARY RISER DIAGRAM, MISSING MASTER BATHROOM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-26 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-26 |
Time |
13:11 |
Sent To |
B |
|
| Notes |
| 2007-06-26 13:19:40 | DENIED; | | | PLUMBING RISER DIAGRAMIS TO CODE, BUT PLANSMUST BE | | | SIGNED AND DATED BY THE PERSON TAKING RESPONSABILITY | | | FOR DRAWINGS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-20 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-20 |
Time |
08:58 |
Sent To |
M |
|
| Notes |
| 2006-11-20 09:09:05 | DENIED; | | | 1. PERSON RESPONSIBLE FOR DRAWINGS MUST PRINT AND SIGN | | | DRAWINGS. | | | 2. RISER DIAGRAM DOES NOT MATCH FLOOR PLAN AND CANNOT | | | BE INSTALLED AS DRAWN. | | | 3. AUTOMATIC CLOTHES WASHER NOT SHOWN ON RISER DIAGRAM. | | | THE BRANCH DRAIN IS REQUIRED TO BE 3" SECTION 406.3 AND | | | A CLEANOUT REQUIRED AT 48" | | | ABOVE FINISH FLOOR. | | | 4. CHANGE NOTE 14 TO WATER HAMMER ARRESTORS. | | | 5. OUTSIDE SHOWER NOT PERMITED TO TIE INTO DRAINAGE | | | SYSTEM. RUN TO DRYWELL OR GRASSY AREA. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2009-05-19 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-05-19 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-05-19 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2009-05-19 15:30:17 | APPROVAL FOR DRIVEWAY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-08 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-08 |
Time |
14:33 |
Sent To |
E |
|
| Notes |
| 2008-01-08 14:38:39 | ***APPROVED - RESUB #3*** | | | | | | PROVISO:BUILDING SHALL NOT EXCEED 30' (MEASURED FROM | | | GRADE TO THE MIDPOINT OF THE ROOF'S PITCH).THE | | | BUILDING IS ALLOWED AN EXTRA 10% IN HEIGHT FOR | | | ACCESSORIES, ALLOWING THE CUPOLA NOT TO EXCEED 33' | | | (MEASURED FROM GRADE TO THE TOP OF THE CUPOLA'S ROOF). | | | THE LOT SHALL MEET THE MINIMUM LANDSCAPING REQUIREMENTS | | | FOUND IN SECTION 94-442 AND 94-445 OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-13 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-13 |
Time |
08:34 |
Sent To |
E |
|
| Notes |
| 2007-08-13 09:11:13 | ***FAILED******RESUB #2*** | | | | | | | | | 1)***EXTENSION OF VARIANCE HAS EXPIRED.WORK | | | REQUIRED TO COMMENCE BY NOVEMBER 5, 2006 AS PER THE ZBA | | | FINAL ORDER***VARIANCE WAS FOR EXTENSION OF | | | GARAGE...NOT ENTIRE HOUSE.MUST OBTAIN A NEW VARIANCE | | | IF PROPOSED WORK IS TO CONTINUE.FOR VARIANCE | | | INFORMATION CONTACT THE PLANNING DEPARTMENT | | | (561)822-1435. | | | | | | NOTE: THE FOLLOWING COMMENTS ARE FOR YOUR INFORMATION: | | | | | | 2)CLARIFY SCOPE OF WORK, SURVEY SHOWS PROPOSED SITE | | | WALL.IF INSTALLING A SITE WALL, PROVIDE AN EASEMENT | | | CONSENT FORM FROM THE CITY OF WEST PALM BEACH | | | DEPARTMENT OF PUBLIC UTILITIES.ALL ELEVATIONS SHALL | | | BE MEASURED FROM GRADE. | | | | | | 3)PROPOSED STRUCTURE DOES NOT MEET SETBACK | | | REQUIREMENTS SET FORTH IN THE APPROVED VARIANCE.THE | | | ZONING BOARD OF APPEALS APPROVED A 12 FT. VARIANCE FROM | | | THE REQUIRED 25 FT. SETBACK.THE REMAINING SETBACK | | | REQUIREMENT IS A MINIMUM OF 13 FEET FROM THE SOUTH | | | OLIVE AVE SIDE.SURVEY SHOWS PROPOSED STRUCTURE AT 9.2 | | | FT.PLAN SP-1 INDICATES PROPOSED STRUCTURE AT 12 FT. | | | FROM SIDE PROPERTY LINE.PLANS MUST BE | | | CONSISTENT...PLANS MUST SHOW COMPLIANCE WITH THE | | | MINIMUM REQUIRED SETBACKOF 13 FT. | | | | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-05-29 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-29 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-29 |
Time |
10:08 |
Sent To |
I |
|
| Notes |
| 2007-05-29 10:13:24 | ***FAILED*** | | | | | | | | | 1)THIS IS A DOUBLE FRONTAGE LOT.THE FRONT SETBACK | | | REQUIREMENT FROM BOTH WORTH COURT SOUTH & SOUTH OLIVE | | | AVE IS 25 FT..THE CORNER SIDE SETBACK REQUIREMENT IS | | | 12.5 FT. FROM WORTH CT.THE PROPOSED BUILDING DOES NOT | | | MEET THE TWO FRONT SETBACK REQUIREMENTS. | | | | | | 2)POOL NOT INCLUDED IN THIS PERMIT. | | | | | | 3)PLEASE SHOW ALL OVERHANG DIMENSIONS FROM WALL TO | | | OUTERMOST POINT OF ROOF. | | | | | | 4)PLEASE PROVIDE SETBACK DIMENSIONS FROM POOL | | | EQUIPMENT AND ANY MOVED A/C EQUIPMENT TO PROPERTY | | | LINES. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-07 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-07 |
Time |
16:16 |
Sent To |
I |
|
| Notes |
| 2006-11-07 16:39:21 | DENIED, | | | 1. THE SURVEY SUBMITTED DOES NOT SHOW THE COMPLETE | | | PROPERTY. THE PROPERTY IS A DOUBLE FRONTAGE LOT AND | | | CORNER LOT. S. OLIVE DOES NOT SHOW ON THE SURVEYS. 2. | | | PLEASE SUBMIT THE EXISTING SURVEY THAT SHOW THE | | | STRUCTURE WITH SETBACKS BEFORE THE PROPOSED | | | CONSTRUCTION. | | | 3. WITH A DOUBLE FRONTAGE LOT, STRUCTURE MUST MEET THE | | | REQUIRED FRONT SETBACK OF 25FT. ON S. OLIVE AVE & WORTH | | | COURT S. SURVEY SUBMITTED DOES NOT SHOW THE STRUCTURE | | | AT 25FT. | | | 4. THE SURVEY SUBMITTED SHOWS THE STRUCTURE AS A | | | COMPLETE PROPOSED STRUCTURE, AS PLANS AND APPLICATION | | | STATES PORTION OF HOUSE TO BE RE-CONSTRUCT. PLEASE | | | CLARIFY. PLEASE SHOW THE PROPOSED WORK ON THE EXISTING | | | SURVEYS WITH SETBACKS. | | | 5. PLEASE SHOW THE A/C UNIT (EXTERIOR) ON THE TWO COPY | | | OF SURVEYS. | | | 6. THE PROPOSED COVERED PATIO IS NOT SHOWN CLEARLY ON | | | FLOOR PLAN. | | | | | | NOTE: THE FLOOR PLANS MUST SHALL ALL INTERIOR ACCESS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|