| Plan Review Stops For Permit 06101114 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-02-20 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-02-20 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2007-02-20 08:24:42 | THE SITE ADDRESS HAS BEEN CHANGED FROM MERRY PL TO | | | CHEERFUL CT.PERMIT HAS BEEN CORRECTED.THE SITE PLANS | | | MUST BE CORRECTED TOO. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-21 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-12-21 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2006-12-21 10:14:28 | A NEW PARCEL CONTROL NUMBER WAS ISSUED BY THE PROPERTY | | | APPRAISER'S OFFICE .THE PERMIT WAS ATTACHED TO THE | | | VALID PCN FROM THE TEMPORARY PCN USED INITIALLY. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-06 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-12-06 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2006-12-06 09:32:30 | ADDRESS HAD BEEN CHANGED TO 1901 MERRY PL. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-02-28 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-02-28 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2008-02-28 15:24:09 | HAROLD PISKURA PICK UPPROVISO SUBMITTALTO HANDLE TO | | | CONTRACTOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-03 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-12-03 |
Time |
10:05 |
Sent To |
PC |
|
| Notes |
| 2007-12-03 10:06:54 | TRUSS PACKAGE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-10-29 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-10-29 |
Time |
12:38 |
Sent To |
PC |
|
| Notes |
| 2007-10-29 12:43:31 | TRUSS PACKAGE BUILDING REVIEW CHECKLIST. | | | | | | 1- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72FOR STRUCTURAL CONNECTORS HU214-3AND HU210-2 | | | ATTACHED DIRECTLY TO MASONRY WALL TO VERIFY COMPLIANCE | | | WITH THE CALCULATED LOADS FOR GIRDER TRUSS FG06.SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004.ENGINEER OF | | | RECORD TO REVIEW AND APPROVE IN WRITING PRODUCT | | | APPROVAL PRIOR TO SUBMITTAL TO THIS OFFICE. SEC. | | | 106.3.3 CITY AMENDMENTSTO FBC 2004. | | | | | | 2- REVISED TRUSS PACKAGE TO BE REVIEWED AND APPROVED BY | | | THE ENGINEER OF RECORD PRIOR TO SUBMITTAL TO THIS | | | OFFICE. | | | | | | 3- IF PROVIDING COVER OR INDEX SHEET TO AVOID SIGNING | | | AND SEALING ALL INDIVIDUAL TRUSSES, THEN ALL | | | INFORMATION REQUIRED BY SEC. 61G15-31003 SHALL BE | | | SUBMITTED. THIS PACKAGE IS MISSING STRUCTURAL ENGINEER | | | OF RECORD INFORMATION, PROPER IDENTIFICATION OF PROJECT | | | (AND ADDRESS SHOWN IS NOT CORRECT) AND A CLEARNAMING | | | AND NUMBERING SYSTEM.INDIVIDUAL SHEETS ARE NOT | | | NUMBERED, WHICH ALLOWS TO MATCH INDEX SHEET. | | | | | | 4- TRUSS LAYOUT IS NOT SIGNED AND SEALED AS REQUIRED BY | | | CHAPTER 471 FLORIDA STATUTE. | | | | | | 5- CLARIFY WHY THE ATTIC LIVE LOAD IS NONCONCURRENT | | | WITH ANY OTHER LIVE LOADS IF FBC 2004 TABLE 1607.1 | | | REQUIRES ALL MINIMUM LIVE LOADS TO BE INCLUDED IN THE | | | DESIGN.CLARIFY WHICH ARE THE OTHER NONCONCURRENT LIVE | | | LOADS.SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 6- THIS PROJECT HAS A RESIDENT INSPECTOR, THEREFORE 3 | | | COMPLETE SETS OF TRUSS DRAWINGS ARE REQUIRED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-07-25 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-07-25 |
Time |
18:51 |
Sent To |
PC |
|
| Notes |
| 2007-07-25 18:51:51 | BUILDING REVISION CHECKLIST: | | | 1- ROOF VENT: | | | A) ARCHITECT APPROVED ROOF VENT NOA 01-0614.05. THIS | | | NOA EXPIRED ON 08/16/2006.DADE COUNTY NOA'S SHALL | | | NOT BE VALID AFTER EXPIRATION DATE.SEE SECOND | | | PARAGRAPH ON COVER PAGE OF NOA SUBMITTED. | | | | | | B)ARCHITECT'S NOTE: "CONTRACTOR RESPONSIBLE FOR | | | PROVIDING REQ'D VENTING PER CALCULATIONS ON DRAWINGS". | | | IT'S THE ARCHITECT'S RESPONSIBILITY TO VERIFY IFTHE | | | NUMBER OFVENTS SHOWN ON PLANSMEET THE VENTING | | | CALCULATIONS USING THE REVISED VENT,NOT THE | | | CONTRACTOR.CONTRACTOR'SRESPONSIBILITYIS TO | | | INSTALLNUMBER OF VENTS VENTSAS SPECIFIED ON PLANS. | | | NOT TO MAKE CALCULATIONS.IF REVISEDVENT DOESN'T | | | MEET THE VENTING CALCULATIONS, THEN REVISE PLANS AS | | | REQUIRED. | | | | | | C) THERE ARE TWO DIFFERENT REVIEW STAMPS. ONE OF | | | THEM IS CLEAR THAT IS THE ARCHITECT'S REVIEW STAMP. | | | WHO'S REVIEW STAMP IS THE OTHER ONE.THE PURPOSE OF | | | THE REVIEW STAMP IS TO DISCLOSE WHO REVIEW IT. | | | OTHERWISE IT'S MEANINGLESS. | | | | | | ***NOTE: SAME COMMENT APPLIES TO SHINGLES PRODUCT | | | APPROVAL. | | | | | | 2- REVISION FEES ARE $50.00PLUS $10.00 PER ADDITIONAL | | | PAGE. OWES $80.00.INFORMATION SUBMITTED IS REVISED | | | SHEET A705, PLUS PRODUCT APPROVAL FOR SHINGLES, PLUS | | | PRODUCT APPROVAL FOR ROOF VENT. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-07-06 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-07-06 |
Time |
17:48 |
Sent To |
PC |
|
| Notes |
| 2007-07-06 17:56:25 | TRUSS PACKAGE CHECKLIST: | | | 1-A) ONLY TWO SETS WERE SUBMITTED. THIS TYPE OF | | | PROJECT REQUIRES THREE COMPLETE SETS.THREE SIGNED AND | | | SEALED SETS AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE | | | AND SEC. 61G15-23 OF FLORIDA ADMINISTRATIVE CODE. | | | | | | B) TRUSS ENGINEER TO PROVIDE ALL THREE SETS WITH | | | ORIGINAL SIGNATURE. COPY OF SIGNATURE IS NOT ALLOWED BY | | | CHAPTER 471 FLORIDA STATUTE. | | | | | | C) EVERY INDIVIDUALSHEETNEEDS TO HAVE | | | ENGINEER'S ORIGINAL SEAL, SIGNATURE AND DATE. | | | OTHERWISE, ENGINEER MAY WANT TO FOLLOW ALL CONDITIONS | | | REQUIREDBY SEC. 61G15-31.003 FLORIDA ADMINISTRATIVE | | | CODE TO COMPLY WITH THE SIGNING AND SEALING OF ALL | | | SHEETS.INFORMATION SUBMITTED DOESN'T COMPLYWITH | | | THIS SECTION. | | | | | | | | | 2- ENGINEER OF RECORD DESIGNED FLOOR TRUSSES TO BE | | | RESTING ON TOP CHORD.TRUSS PACKAGE SHOWS FLOOR | | | TRUSSES RESTING ON A TRUSS HANGER SUPPORTING TRUSS ON | | | BOTTOM CHORD. REVISE EITHER TRUSS PACKAGE OR ENGINEERED | | | DRAWINGS AS REQUIRED TO MATCH. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-07-06 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-07-06 |
Time |
15:45 |
Sent To |
PC |
|
| Notes |
| 2007-07-06 16:56:03 | REVISION SECOND CHECKLIST: | | | 1- AS EXPLAINED ON PREVIOUS CHECKLIST THIS IS A | | | REVISION TO APPROVED PRODUCT APPROVALS NOT A SUBMITTAL. | | | THEREFORE, OWES $80.00 FOR REVISION FEES. | | | | | | 2- AS REQUESTED ON PREVIOUS CHECKLIST ALL PRODUCT | | | APPROVALS NEED TO BE REVIEWED AND APPROVED IN WRITING | | | (NOT SIGNING AND SEALING)BY DESIGNER OF RECORD AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | PRODUCT APPROVALS SUBMITTED STILL ARE NOT REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 3- THERE IS A MULLION PRODUCT APPROVAL SUBMITTED. | | | ACCORDING TO PLANS THERE ARE NOT WINDOW MULLIONS, BUT | | | CONCRETE BLOCK COLUMNS.IF USING WINDOW MULLIONS, THEN | | | DRAWINGS NEED TO BE REVISED AND SUBMITTED FOR REVISION | | | AS REQUIRED. | | | | | | 4- AS EXPLAINED ON PREVIOUS CHECKLIST SUBMIT ONLY-THE | | | PRODUCT APPROVALS THAT APPLY TO THIS BUILDING TO | | | EXPEDITE REVIEW PROCESS AND AVOID UNNECESSARY FEES. | | | THERE IS A PRODUCT APPROVAL SUBMITTED FOR METAL/GLASS | | | SWING DOORS THAT DOESN'T APPLY TO THIS BUILDING. SEE | | | PLANS. | | | | | | ***NOTE: | | | AS EXPLAINED ON PREVIOUS CHECKLIST RESUBMITTAL FEES ARE | | | DUE ALL THE TIME REVISIONS ARE SUBMITTED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-06-13 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-06-13 |
Time |
15:47 |
Sent To |
PC |
|
| Notes |
| 2007-06-13 15:52:28 | REVISION CHECKLIST: | | | | | | 1- THIS IS NOT A SUBMITTALBUT A REVISION ON | | | PREVIOUSLY APPROVED PRODUCT APPROVALS. THEREFORE OWES | | | $70.00 FOR REVISION FEES. | | | | | | 2- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND | | | APPROVED IN WRITING (NOT SIGNING AND SEALING) BY THE | | | DESIGNER OF RECORDAS REQUIRED BY SEC. 106.3.3 CITY | | | AMENDMENTS TO FBC 2004. PRODUCT APPROVALS SUBMITTED | | | DON'T SHOWDESIGNER OF RECORD APPROVAL IN WRITING. | | | | | | 3- SINGLE HUNG WINDOWS PRODUCT APPROVAL: | | | A) PROVIDE CURRENT PRODUCT APPROVAL FL42-R4. (ONE | | | SUBMITTED IS FL 42-R1). | | | | | | B) PROVIDE ONLY ALL THE TECHNICAL INFORMATION | | | (DRAWINGS, SPECS, ETC) THAT WAS SUBMITTED TO OBTAIN THE | | | FLORIDA PRODUCT APPROVAL. GO THE FLORIDA WEBSITE | | | WWW.FLORIDABUILDING.ORG AND DOWNLOAD CORRESPONDING | | | INFORMATION TO SPECIFIC MODEL TO BE INSTALLED. | | | | | | C) MAKE SURE ALL DRAWINGS ARE LEGIBLE. | | | | | | 4- SLIDING GLASS DOORS: | | | A) SAME COMMENTS AS FOR SINGLE HUNG WINDOWS APPLY. | | | | | | 5- SUBMIT ONLY THE PRODUCT APPROVALS THAT APPLY TO THIS | | | BUILDING TO EXPEDITE REVIEW PROCESSAND AVOID | | | UNNECESSARY FEES.THERE ARE PRODUCT APPROVALS FOR | | | SWING DOORS THAT DON'T APPLY TO THIS BUILDING. | | | | | | ***NOTE: | | | RESUBMITTAL FEES FOR REVISIONS ARE THE SAME AS FOR THE | | | FIRST TIME REVISIONS ARE SUBMITTED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-03-28 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-03-28 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2007-03-28 13:42:52 | ADDRESS CHANGED FROM 1901 CHEERFUL COURT TO 455 | | | CHEERFUL CT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-02-14 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-02-14 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2007-02-14 18:34:06 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- PROVIDE CORRECT DRAWINGS FOR ENTRY DOOR.NOA | | | 02-0215.04 SUBMITTED HAS THE "INSWING" DOOR DRAWINGS. | | | THIS IS A DADE COUNTY PRODUCT APPROVAL DIVISION MISTAKE | | | THAT WAS ALREADYREVISED. NOW WEBSITE HAS CORRECT | | | "OUTSWING" DOOR DRAWINGS. PROVIDE 3 COPIES, REVIEWED | | | AND APPROVED BY THE DESIGNER OF RECORD. | | | | | | 2-RINKER SPECIFICATIONS LETTER FOR 2 HOUR CONCRETE | | | BLOCK: PROVIDE LETTER ADDRESSED TO THE CITY OF WEST | | | PALM BEACH AND WITH CORRECT PROJECT NAME.THIS IS | | | MERRY PLACE PROJECT, NOT BOCA DEVELOPMENT. | | | | | | 3- DESIGNER OF RECORD TO PROVIDE COMPLETE | | | SPECIFICATIONS/DETAILS FOR INSTALLATION OF HARDISOFFIT | | | & CEMSOFFIT PANELS. SEE SHEET 3 OF 3 OF NOA 02-0729.02 | | | DRAWINGS SUBMITTED. | | | (TRUSSES ARE 24" O.C., WHILEINSTALLATION | | | SPECIFICATIONS FOR HARDISOFFIT PANELS REQUIRES WOOD | | | MEMBERS AT 16"O.C. MAXIMUM). | | | SEC. 106.1.2 CITY AMENDMENTSTO FBC 2004. | | | | | | 4- SUBMIT ALL TRUSS DRAWINGS FOR REVIEW PRIORTO | | | CONSTRUCTION/INSTALLATION. TRUSS PACKAGE TO BE REVIEWED | | | AND APPROVED BY DESIGNER OF RECORDPRIOR TO | | | SUBMITTAL. | | | | | | 5- PROVIDE COPY OFTHE RECORDED MERRY PLACE PLAT FOR | | | CITY RECORDS. | | | | | | 6- PROVIDECOPY OF APPROVED AND RECORDED SURVEY | | | SHOWING UNITY OF TITLE REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-01-05 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-01-04 |
Time |
18:53 |
Sent To |
|
|
| Notes |
| 2007-01-05 10:44:33 | BUILDING REVIEW SECOND CHECKLIST: | | | 1- REVISE ENERGY CALCULATIONS: | | | A) AS REQUESTED ON PREVIOUS CHECKLIST, CALCULATIONS | | | NEED TO BE DONE FOR THE WHOLE BUILDING, NOT FOR EACH | | | UNIT AS REQUIRED BY SEC. 13-600.0 METHOD A OF FBC | | | 2004. | | | | | | | | | B) AS REQUESTED ON PREVIOUS CHECKLIST, ENGINEER TO | | | PROVIDE ALL HIS INFORMATION AS REQUIREDBY CHAPTER 471 | | | FLORIDA STATUTES AND FLORIDA ADMINISTRATIVE CODE SEC. | | | 61G15-23.002. | | | | | | C) CALCULATIONS SUBMITTED FOR INDIVIDUAL UNITS HAVE | | | THE FOLLOWING INCORRECT INFORMATION: | | | * NUMBER OF BEDROOMS. | | | ** SLAB ON GRADE TOTAL PERIMETER FEET. | | | *** CLARIFY HOW ARE THESE CALCULATIONS DONE FOR | | | WORST CASE SCENARIO IF THERE IS NOT SHEET SHOWING | | | OPENINGS SUN EXPOSURE ORIENTATION. | | | | | | 2- REVISION CLOUDS ON SHEET A004 DON'T ALLOW THE OTHER | | | INFORMATION TO BE LEGIBLE.REVISE AS REQUIRED. | | | | | | 3- SURVEY AND SITE PLAN SHOWN ON SHEETS A100, A101 AND | | | A102 DON'T MATCH.ACCORDING TO THE RECORDED SURVEY, | | | THERE IS AN ALLEY BY BUILDING C3. SITE PLAN SHOWS | | | PARKING SPACES. REVISE AS REQUIRED. THIS COMMENT COULD | | | NOT BE ADDREESED BEFORE BECASUE THIS IS THE FIRST TIME | | | SURVEY IS SUBMITTED FOR REVIEW. | | | | | | 4- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) UNIT ENTRY DOOR: DRAWINGS SUBMITTED ARE FOR | | | "INSWING" DOORS. NEED DRAWINGS FOR "OUTSWING" DOORS. | | | | | | B) ALL USP OR SIMPSON CONNECTORS SPECIFIED ON PLANS | | | AND DETAILS.ONLY THE ONES SHOWN ON TRUSS ANCHOR | | | SCHEDULE WERE PROVIDED AND THEY ARE MISSING THE PAGE | | | SHOWING THE SPECIFIC CONNECTOR. PROVIDE FLORIDA PRODUCT | | | APPROVAL COVER PAGE AND PAGE SHOWING EACH CONNECTOR. | | | | | | C) 2 HOUR CONCRETE BLOCK AS REQUIRED BY UL WALL | | | ASSEMBLY U905. | | | | | | D) CEMENTITIOUS PANELS AT ENTRY OVERHANGS. SEE | | | DETAIL 11/A705. | | | | | | E) EXTERIOR DOOR PANEL FOR RECESSED GAS WATER | | | HEATER. | | | | | | 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 6- NEED TO CONTACT HAROLD PISKURA, INSPECTION SERVICES | | | MANAGER (561)805-6711, TO COORDINATE SPECIAL INSPECTOR | | | SERVICES. | | | | | | 7- PLEASE MAKE SURE ENERGY CALCULATIONS HAVE CORRECT | | | ADDRESS, BUILDING TYPE, PERMIT NUMBER, ETC. | | | | | | 8- NORTH ARROW IN SURVEY IS POINTING TO THE WRONG | | | DIRECTION. REVISE AS REQUIRED. | | | | | | 9- A) EAST SIDE WALL DOESN'T COMPLY WITH TABLE 704.8 | | | FBC 2004. IT EXCEEDS MAXIMUM ALLOWED PERCENTAGE OF | | | OPENINGS.ACCORDING TO RECORDED SURVEY BUILDINGS ARE | | | NOT LOCATED ON THE SAME LOT, BUT ON DIFFERENT TRACTS. | | | THEREFORE, PERCENTAGE OF OPENINGS IS MEASURED TO THE | | | PROPERTY LINE SHOWN ON SURVEY. | | | | | | B) SURVEY TO INDICATE SETBACKS FROM BUILDING TO ALL | | | PROPERTY LINES FOR ACCURACY IN DETERMINATING PROPER | | | PERCENTAGE OF OPENINGS.IT WILL ALSO HELP INSPECTOR | | | WHEN CHECKING FORMBOARD SURVEY. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-12-05 |
Time |
19:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-12-05 |
Time |
19:03 |
Sent To |
|
|
| Notes |
| 2006-12-05 19:04:29 | BUILDING REVIEW CHECKLIST: | | | 1- NOTICE OF COMMENCEMENT AND IMPACT FEES STAMPED | | | DRAWINGS AND PAID RECEIPTS WILL BE SUBMITTED LATER. | | | | | | 2- REVISE ENERGY CALCULATIONS: | | | A) CALCULATIONS NEED TO BE PERFORMED FOR THE WHOLE | | | BUILDING, NOT FOR EACH UNIT. SEC. 13-600.0 METHOD A OF | | | 2004 FBC. | | | B) NAME AND LICENSE # OF ENGINEER AS REQUIRED BY | | | CHAPTER 471 FLORIDA STATUTES. | | | C) PROVIDE COMPLETE INFORMATION FOR ITEM #8, FLOOR | | | TYPES. | | | D) INSULATION R VALUE SPECIFIED IN PROJECT MANUAL | | | SPECS SEC. 07200 TO MATCH ENERGY CALCULATIONS. | | | E) PROVIDE COMPLETE INFORMATION ON TOP OF FORM. NEED | | | ADDRESS AND BUILDER NAME. | | | F) OWNER/AGENT TO SIGN AND DATE ALL ENERGY FORMS. | | | NOTE: THIS APPLIES TO ALL ENERGY FORMS FOR ALL | | | BUILDINGS. CHECK ALL ENERGY FORMS TO BE SUBMITTED. | | | | | | 3- NEED SIGNED AND SEALED SURVEYS SHOWING EXACT | | | LOCATIONS OF BUILDINGS IN RELATIONSHIP WITH THE | | | PROPERTY LINES AND OTHER BUILDINGS TO VERIFY COMPLIANCE | | | WITH TABLES601, 602 FOR FIRE RESISTANCE AND TABLE | | | 704.8 FBC 2004 FOR OPENINGS ALLOWED.PROVIDE ALL | | | DISTANCES BETWEEN BUILDINGS AND PROPERTY LINES AND MAKE | | | SURE ALL BUILDINGS HAVE THE DIMENSIONS BETWEEN BUILDING | | | SEPARATION FOR BUILDINGS ON SAME LOT. IF BUILDINGS ARE | | | ON SAME LOT, THEN SPECIFY THE PROPOSED PROPERTY LINE | | | BETWEEN THEM.BUILDINGS WITH IRREGULAR SHAPES NEED TO | | | SHOW DIMENSIONS WITH CLOSEST DISTANCE TO ADJACENT | | | BUILDINGS. EG: SOME BUILDINGS HAVE SETBACKS IN THE | | | FOOTPRINT. MAKE SURE DISTANCES PROVIDED INCLUDE THE | | | CLOSEST DISTANCE BETWEEN BUILDINGS. SITE PLAN SUBMITTED | | | DOESN'T PROVIDE ALL THIS INFORMATION. | | | | | | 4- SHOW ACCESSIBLE ROUTE FROM PARKING SPACE TO ALL | | | APARTMENT ENTRANCES, RECREATIONAL AREAS AND PUBLIC | | | BUILDINGS.WHERE ARE THE DRAWINGS?. | | | | | | 5- INFORMATION REGARDING HANDICAPPED UNITS AND | | | ADAPTABLE UNITS IS CONFUSING.ACCORDING TO FAIR | | | HOUSING ACT,"ALL"GROUND FLOOR UNITS MUST BE | | | "ACCESSIBLE"FROM THE PARKING SPACE TO THE UNIT | | | ENTRANCE. THEN,ALL THE UNITS MUST BE "ADAPTABLE"PER | | | FHA.INFORMATION ON SHEET A100 IS INDICATING THAT | | | THERE ARE 9 ADAPTABLE UNITS ON ACCESSIBLE ROUTE.IF | | | THE INTENTION IS TO GO BEYOND FHA AND TO HAVE FULLY | | | HANDICAPPED UNITS, THEN CLARIFY THAT SUCH UNITS WILL BE | | | FULLY HANDICAPPED UNITS, NOT ADAPTABLE. | | | | | | 6- SHEET A004: | | | A) MISSING UNIT MODEL TYPE IN PROJECT TABULATION | | | CHART. | | | B) BUILDING AND UNIT AREAS DON'T MATCH. SEE SHEET | | | A004 AND SHEETS A203, A204, A205,A310.1 AND A310.2. | | | REVISE AS REQUIRED.NEED CORRECT AREAS TO ESTIMATE | | | BUILDING VALUATION. SEC. 108.3 CITY AMENDMENTS TO FBC | | | 2004. PROVIDE PORCHES, BALCONIES AND BUILDING AREAS. | | | | | | 7- SHEET A101: | | | A) HANDICAPPED PARKING FOR FAIR HOUSING UNITS AND | | | CHAPTER 11 FBC 2004 CAN'T OVERLAP TO ACCOMPLISH TOTAL | | | NUMBER OF REQUIRED PARKING SPACES.NEED TO PROVIDE | | | SEPARATE HANDICAPPED PARKING FOR FAIR HOUSING UNITS AND | | | PUBLIC ASSEMBLY AREAS.SEE TABLE ON SECTION 11-4.1.2 | | | FOR REQUIRED NUMBER OF PARKING SPACES. THIS COMMENT | | | APPLIES TO BUILDINGS F AND C FOR MIXED USE BUILDINGS. | | | | | | B) PROVIDE DRAWINGS SHOWING PARKING SIZES AND | | | ACCESSIBLE ROUTES FROM PARKING SPACES TO RESIDENTIAL | | | UNITS AND PUBLIC ASSEMBLY BUILDINGS TO VERIFY | | | COMPLIANCE WITH FAIR HOUSING ACT AND CHAPTER 11 FBC | | | 2004. | | | | | | C) SPECIFY IF PROVIDING VISITORS PARKING SPACES TO | | | VERIFY COMPLIANCE WITH FAIR HOUSING ACT. | | | | | | 8- OWNER TO PROVIDE LETTER CERTIFYING THAT NO FEDERAL | | | MONIES ARE USED FOR THIS PROJECT. OTHERWISE,PROJECT | | | NEEDS TO BE REVIEWED FOR SECTION 504 OF THE | | | REHABILITATION ACT COMPLIANCE. | | | | | | 9- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) SINGLE HUNG WINDOW. NOA 01-0629.08 IS EXPIRED. | | | ALSO, NEED FLORIDA PRODUCT APPROVAL COVER PAGE. GO TO | | | WWW.FLORIDABUILDING.ORG TO DOWNLOAD CORRESPONDING COVER | | | PAGE. FLORIDA PRODUCT APPROVAL COVER PAGE APPLIES TO | | | ALL PRODUCT APPROVALS. IF THERE IS NO FLORIDA PRODUCT | | | APPROVAL, THEN SUBMIT THE DADE COUNTY NOA ONLY. | | | | | | B) UNIT ENTRY DOOR: DRAWINGS SUBMITTED ARE FOR | | | "INSWING" DOORS. NEED DRAWINGS FOR "OUTSWING" DOORS. | | | | | | C) ALL USP OR SIMPSON CONNECTORS SPECIFIED ON PLANS | | | AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL | | | COVER PAGE AND PAGE SHOWING SPECIFIC CONNECTOR. | | | | | | D) SLIDING GLASS DOORS. PROVIDE FLORIDA PRODUCT | | | APPROVAL COVER PAGE. | | | | | | E) ROOF SHINGLES. NEED FLORIDA PRODUCT APPROVAL | | | COVER PAGE. | | | | | | F) RIDGE VENT. NEED FLORIDA PRODUCT APPROVAL COVER | | | PAGE. | | | | | | G) 770-D ROOF LOUVER. NEED FLORIDA PRODUCT APPROVAL | | | COVER PAGE. | | | | | | H) 2 HOUR CONCRETE BLOCK AS REQUIRED BY UL WALL | | | ASSEMBLYU905. | | | | | | I) CEMENTITIOUS PANELS FOR ENTRY OVERHANGS. SEE | | | DETAIL 11/A705. | | | | | | J) FALSE SKYLIGHT. SEE ELEVATIONS. | | | | | | K) EXTERIOR DOOR PANEL FOR RECESSED GAS WATER | | | HEATER. | | | | | | 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 11- SHEET A103: | | | A) REVISE DETAIL 19 TO MATCH DETAIL 7/700.1. SHELVES | | | HEIGHT 48" MAX. | | | | | | B) PROVIDE DETAILS/SPECS FOR GRAB BARS | | | REINFORCEMENT. MATERIAL AND INSTALLATION. SEC. 106.1.2 | | | CITY AMENDMENTS TO FBC 2004. | | | | | | 12- SHEET A104: | | | A) CLARIFY COMMON USE FACILITIES NOTE # 2A. WHAT'S | | | THE QUESTION MARK FOR?. | | | B) REVISE RESTROOMS NOTE # 5C. SEE FIGURE 30 ON | | | CHAPTER 11 FBC 2004. | | | | | | 13- SHEET 110: | | | A) DETAIL 20: CLARIFY QUESTION MARKS ON CONCRETE | | | BLOCK THICKNESS. | | | B) DETAIL 18: REQUIRES 2X10 JOISTS AT 16" OC. REVISE | | | UNDER STAIRS DETAILS TO MATCH THIS ASSEMBLY. | | | C) UPDATE ASSEMBLY AND PENETRATIONS SCHEDULE. | | | REFERENCE UL 2004, NOT UL 1999. | | | | | | 14- SHEET A203: | | | A) SPECIFY DOOR SIZE FOR DOOR LEADING TO MASTER | | | BEDROOM. | | | | | | B) CLARIFY SQUARE FOOTAGE FOR UPPER FLOOR UNIT. | | | ALSO, COORDINATE ALL THESE AREAS WITH GENERAL AREA | | | TABULATION ON SHEET A004. | | | | | | C) PANTRIESWITH NARROW DOORS TO HAVE 18" MAX. | | | DEPTH. SEE PAGE 7.17 FAIR HOUSING ACT.THIS COMMENT | | | APPLIES TO ALL GROUND UNITS THROUGHOUT ENTIRE PROJECT. | | | REVISE AS REQUIRED. | | | | | | D) BEDROOM # 2 CLOSET DOOR NEEDS TO COMPLY WITH FAIR | | | HOUSING ACT. NEED WIDER DOORS TO REQACH AT THE ENDS OF | | | CLOSET. SEE PAGE 3.14 FAIR HOUSING ACT AND REVISE AS | | | REQUIRED. | | | | | | 15- SHEET A204: | | | A) CLOSET DOORS FOR SECONDARY BEDROOMS DON'T COMPLY | | | WITH FAIR HOUSING ACT. SEE PAGE 3.15 OF FHA. NEED WIDER | | | DOORS TO ALLOW REACH AT THE ENDS OF CLOSET. ALSO, DOOR | | | TYPE SPECIFIED DON'T MATCH DOOR SCHEDULE. | | | | | | B) REVISESQUARE FOOTAGE AREAS. THEY CAN'T BE THE | | | SAME.COORDINATE AREAS WITH TABULATION ON SHEET A004. | | | | | | C) PANTRIES WITH NARROW DOORS TO HAVE 18" MAX. | | | DEPTH. SEE PAGE 7.17 FAIR HOUSING ACT. THIS APPLIES TO | | | ALL GROUND FLOOR UNITS AND ALL UNIT TYPES. | | | | | | 16- SHEET A205: | | | A) UNIT C1: CLOSET DOORS FOR SECONDARY BEDROOMS | | | DON'T COMPLY WITH FAIR HOUSING ACT. SEE PAGE 3.15 OF | | | FHA. NEED WIDER DOORS TO ALLOW REACH AT THE ENDS OF THE | | | CLOSET. THIS ALSO APPLIES TO B1 UNIT AND ALL UNITS IN | | | GROUND FLOOR. REVISE ALL CLOSET DOORS AS REQUIRED. | | | | | | B) REVISE SQUARE FOOTAGE AREAS. THEY CAN'T BE THE | | | SAME. COORDINATE WITH CHART ON SHEET A004. | | | | | | C) PROVIDE COMPLETE DETAILS AND SPECS FOR ROLL-IN | | | SHOWERS. | | | | | | D) PANTIRES WITH NARROW DOORS TO HAVE 18" DEPTH. | | | TYP. ALL GROUND FLOOR UNITS. | | | | | | 17- SHEET A310.2: | | | A) VENTILATION CALCULATIONS: COORDINATE SIZE OF | | | RIDGE VENT. SEE RIDGE VENT PRODUCT APPROVAL FOR | | | REQUIRED OPENING. REVISE CALCULATIONS AS REQUIRED. | | | REVISE DETAIL 16/A705 AS REQUIRED. | | | | | | B) GENERAL ROOF NOTE #2 CALLS FOR DETAIL 14/A705. | | | MISSING THAT DETAIL. | | | | | | 18- SHEET A400: | | | A) ALL DETAILS TO SPECIFY PRESSURE TREATED WOOD (OR | | | ANY OTHER APPROVED METHOD TO ISOLATE WOOD WHEN IN | | | CONTACT WITH CONCRETE OR CONCRTE BLOCK). SEC. 2304.11 | | | FBC 2004. | | | | | | B) ENLARGED ELEVATIONS DON'T CORRESPOND TO THIS | | | BUILDING. REVISE AS REQUIRED. | | | | | | 19- SHEET A500: | | | A) SECTION 17: FLOOR ASSEMBLYL-521 AND INFORMATION | | | ON TYPICAL FLOOR CONSTRUCTION ON SAME DRAWING DON'T | | | MATCH. REVISE AS REQUIRED. ALSO, INFORMATION DOESN'T | | | MATCH SPECIFICATION SHOWN ON SHEET A111. | | | B) REVISEINFORMATION ON UL L-521 ON SHEET A111. | | | SEE 2004 UL BOOK AND REVISE SPECS TO MATCH SUCH | | | LISTING. | | | C) SPECS ON WALL ASSEMBLY U905 DOESN'T MATCH | | | INFORMATION SHOWN ON SAME DRAWING POINTING TO WALL | | | AREAS. REVISE AS REQUIRED. | | | | | | D) PROVIDE INFORMATION THAT ADDRESSES MINIMUM LABELS | | | OF SOUND INSULATION AS REQUIRED BY SEC. 1207.2 AND | | | 1207.3. | | | | | | E) PROVIDE FIREBLOCKING AT ROOF ASSEMBLY | | | INTERSECTION. FLOOR ASSEMBLY NOTE ON DETAIL 17 CLEARLY | | | SPECIFIES TO SEAL JOINTS AT WALL . THIS IS NOT | | | SPECIFIED AT CEILING AREA.SEC. 717 FBC 2004. | | | | | | 20- SHEET A501:MISSING DETAIL 14/ A705 SPECIFIED ON | | | WALL SECTION 16 AND 18. | | | | | | 21- SHEET A701.1:DETAIL 01: HOW IS THE FASTENER | | | EMBEDED 1-1/4" IN TO THE BUCK IF THE BUCK IS ONLY 1X | | | THICK. REVISE AS REQUIRED. | | | | | | 22- SHEET A703: WOOD IN CONTACT WITH CONCRETE BLOCK TO | | | BE PRESSURE TREATED. REVISE DETAILS 01 AND 06 AS | | | REQUIRED. | | | | | | 23- SHEET A705: | | | A) DETAIL 02: REVISE FLASHING FASTENER SPACING AS | | | REQUIRED BY ROOFING APPLICATION STANDARD RAS 111. | | | | | | B) REVISE DETAIL 16. SEE RIDGE VENT PRODUCT APPROVAL | | | FOR RIDGE CUT OUT DIMENSION. | | | | | | C) PROVIDE COMPLETE STRUCTURAL DETAIL SHOWING | | | INSTALLATION OF FALSE SKYLIGHT TO COMPLY WITH SEC. 1609 | | | FBC 2004. | | | | | | 24- SHEET A706.1: | | | A) DETAIL 00 (?): CHECK VENT HOOD SPECIFICATIONS FOR | | | MIN. CLEARANCE REQUIRED FROM THE RANGE. PROVIDE VENT | | | HOOD SPECS AND REVISE DETAIL AS REQUIRED. | | | | | | 25- SHEET S-1:FOUNDATION PLAN STILL SHOWS A DROP AT | | | THE ENTRANCE TO UNITS. ALL GROUND FLOOR UNITS NEED TO | | | COMPLY WITH FAIR HOUSING ACT. REVISE AS REQUIRED. | | | | | | 26- SHEET S-4: TRUSS TIE DOWN SCHEDULE. REVISE NOTE #6 | | | FOR CONNECTOR C (SIMPSON MGT). NEED 12" EMBEDMENT. SEE | | | SIMPSON CATALOGUE. | | | | | | 27- PROVIDE COMPLETE DETAILS AND SPECS FOR INSTALLATION | | | OF RECESSED GAS WATER HEATER. PROVIDE DETAILS AND SPECS | | | FOR WALL SEPARATING WATER HEATER AND AIR HANDLER UNIT. | | | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-18 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-18 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2006-12-18 14:21:25 | PLANS OK, STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-26 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-26 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2006-11-26 13:43:26 | MERRY PLACE | | | | | | 1826 MERRY PLACE TYPE X BLDG. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW AND SOME | | | NEW NOTES DUE TO PLANS NOW BEING SUBMITTED WITH SOME | | | ADDITIONAL INFORMATION. | | | | | | ********** UNSAT ************* | | | | | | 1) NOTE: PLEASE SEE 210.52B1, 210.11C1 AND 220.16 FOR | | | THE MINIMUM REQUIRED CIRCUITING AND LOADS FOR THE | | | DINING ROOM CIRCUIT(S). PLEASE ALSO SEE THAT NO OTHER | | | ELECTRICAL DEVICES SUCH AS LIGHTING MAY BE PLACED ON | | | SAID CIRCUIT. | | | MUST BE 20A AND #12 AND ON ONE OR MORE OF THE CIRCUITS | | | AS NOTED IN CODES ABOVE. | | | PLEASE SEE THAT A DESIGNATED AREA AND THE LIKE SHALL BE | | | INDICATED. | | | | | | 2) NOTE: PLEASE BE SURE PLANS REFERENCE THE FOLLOWING | | | CODES: NFPA-70 2002, NFPA-72 2002. THIS COULD NOT BE | | | LOCATED ON PLANS AND IS REQUIRED. | | | | | | 3) NOTE: PLEASE SEE HOUSE LOADS WHICH SHALL INDICATE | | | ALL CONTINUOUS LOADS SUCH AS LIGHTING AT 125%. 215.3, | | | 230.42 ETC | | | PLEASE SEE THE LIGHTING LOADS AS SHOWN DO NOT CORRELATE | | | WITH THE NUMBER OF FIXTURES ON PLANS OR THE WATTAGE ON | | | THE FIXTURE SCHEDULE. THE LOADS BEING SHOWN FOR | | | INSTANCE FOR THE EXTERIOR LIGHTS IS LISTED AT 1000 | | | WATTS, HOWEVER AS THE FIXTURE TYPE ON PLANS SHOWS | | | SEVENTEEN F-1 FIXTURES WHICH ARE 100 WATTS EACH THOSE | | | ALONG EXCEED THE LOAD AS SHOWN ON PANEL SCHEDULE FOR | | | THIS CIRCUIT. | | | | | | 4) NOTE:PLEASE SEE 410.8 FOR MINIMUM CLEARANCES | | | PERMITTED IN STORAGE AREAS. | | | (UNDER STAIRS) FIX TYPE "H". PLEASE KNOW, WHEN SHELVING | | | IS NOT SHOWN, A MIN | | | 18" IS ASSUMED AND THE LIGHT FIXTURE AS SHOWN AND TYPE | | | DESIGNATED SHALL MEET THE MIN CLEARANCES REQUIRED. | | | PLEASE ADJUST | | | | | | 5) NOTE: PLEASE SEE CALCULATIONS ALSO MENTIONS HEAT | | | LOADS SHOWN AND BEING DONE AT 100%, YET THE KW RATINGS | | | AS SHOWN DOES NOT CORRELATE WITH THE MECHANICAL PLANS | | | OF 5KW? | | | PLEASE ADJUST. | | | 220.21 | | | | | | 6) NOTE: PLEASE SEE THE HOUSE PANEL ON E-311 IS BEING | | | SHOWN AS 100MLO AND THE RISER SHOWS THIS AS 60A MLO. | | | IT IS KNOWN THAT A 60A BREAKER IS FEEDING THIS PANEL. | | | | | | 7) NOTE: PLEASE SEE E203 WHICH INDICATES A KEYNOTE #7, | | | HOWEVER UNDER KEYNOTES, THERE IS NO #7? | | | PLEASE SEE THIS APPEARS TO BE A DISPOSAL, HOWEVER THERE | | | IS NOTHING LISTED ON PANEL SCHEDULES OR IN LOAD | | | CALCULATIONS? | | | PLEASE CLARIFY WHAT THIS IS? | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | | | | **IF THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF | | | THE NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE | | | DO NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-12-05 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-12-05 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2006-12-05 13:52:56 | SEE06101116 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-11-22 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-11-22 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2006-11-22 16:40:40 | WE DO NOT HAVE THE CIVIL DWGS FOR THIS PERMIT PROJECT | | | BUT WE REVIEWED,MADE FOLLOWING COMMENTS TO EXPEDITE | | | THE PERMITTING PROCESS: PLEASE PROVIDE FOLLOWING INFO | | | IN YOUR CIVIL DRAWINGS FOR THIS PERMIT SITE: | | | 1.DID YOU MAKE ANY CHANGES IN STORM WATER/DRAINAGE | | | SYSTEM FROM PREVIOUS MASTER PERMIT? PLEASE TELL US WHAT | | | CHANGES YOU MADE IN WRITING AND MUST BE APPROVED FROM | | | SFWMD ALSO. AND A COPY OF SFWMD. | | | 2. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON CIVIL | | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | | PARKING, HANDICAP PARKING, PAINTPER CITY CODES ETC.,, | | | MUST MEET PER ADA,,ETC., | | | 3. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 4. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION FOR THIS PERMIT PROJECT MUST MEET FL | | | BLDG CODE, PLEASE SHOW ON THE DRAWINGS., | | | 5. HOW YOU CONNECT TO THE ROOF DRAINS ? WHERE THE ROOF | | | DRAINS GO? | | | 6. PLEASE SHOW ON DRAWINGS,POLLUTION PREVENTION | | | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT | | | FENCE AROUND THE SITE | | | 7. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED 8. | | | ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND YOUR | | | THIS BUILDING SITE FOR STORM WATER DRAIN. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-23 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-23 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2007-01-23 14:34:46 | *****APPROVED***** | | | | | | | | | | | | COMMENTS FROM PREVIOUS FIRE PLAN REVIEW OF 11/28/2006 | | | HAVE BEEN ADDRESSED.SHEETS A410, E201, E202, AND E204 | | | WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-28 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-11-28 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2006-11-28 14:04:58 | ****DENIED**** | | | | | | | | | | | | 1.PLEASE VERIFY THE ADDRESS OF THIS BUILDING WITH | | | LILI URSA OF THECITY'S ADDRESSING DIVISION AT | | | 561-822-1239.THE NEW ADDRESS SHALL BE IN THE TITLE | | | BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 2.SHOW/DISPLAY THE NUMERICAL ADDRESS OF THE BUILDING | | | ON THE PROPER ELEVATION.AS PER WEST PALM BEACH CODE, | | | THOSE NUMBERS SHALL BE NO LESS THAN 6" IN HEIGHT AND 1" | | | IN WIDTH.INDIVIDUAL APRTMENT/UNIT SHALL BE NO LESS | | | THAN 3" IN HEIGHT. | | | | | | 3..AS PER NFPA 101 - 10.2.8.1 -2003 EDITION, | | | INTERIOR FINISH FOR WALLS AND CEILINGS IN AN | | | UNSPRINKLERED BUILDING SHALL BE CLASS "A" OR CLASS | | | "B". | | | | | | 4.FIRE EXTINGUISHERS TO BE 2A-10BC RATED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | SHEET INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | CAPT MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-12-27 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-12-27 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2006-12-27 08:07:44 | SEPARATE GAS PERMIT REQUIRED - GAS PLANS/REQUIREMENTS | | | SHALL BE SUBMITTED AT THE TIME OF APPLICATION. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-11-21 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-11-21 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2006-12-27 07:57:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1B. SEPARATE GAS PERMIT REQUIRED. SUBMIT THE FOLLOWING | | | INFORMATION: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. AN ISOMETRIC IS REQUIRED FOR EACH GAS | | | SYSTEM SHOWING THE PIPING FROM THE METER TO THE MOST | | | REMOTEAPPLIANCE FOR EACH UNIT. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | H. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-19 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-19 |
Time |
08:53 |
Sent To |
P |
|
| Notes |
| 2008-02-19 08:54:11 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-04 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-04 |
Time |
13:35 |
Sent To |
M |
|
| Notes |
| 2007-12-04 13:35:27 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-21 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-21 |
Time |
12:54 |
Sent To |
B |
|
| Notes |
| 2007-11-21 12:54:27 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-21 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-21 |
Time |
12:27 |
Sent To |
B |
|
| Notes |
| 2007-11-21 12:27:43 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-21 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-21 |
Time |
09:39 |
Sent To |
M |
|
| Notes |
| 2007-11-21 09:39:37 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-15 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-15 |
Time |
10:11 |
Sent To |
M |
|
| Notes |
| 2007-11-15 10:11:56 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-02 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-02 |
Time |
10:03 |
Sent To |
M |
|
| Notes |
| 2007-11-02 10:03:56 | TO "TGORDON" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-17 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-17 |
Time |
12:53 |
Sent To |
M |
|
| Notes |
| 2007-10-17 12:54:05 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-03 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-03 |
Time |
08:27 |
Sent To |
B |
|
| Notes |
| 2007-08-03 08:27:34 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-03 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-03 |
Time |
15:54 |
Sent To |
B |
|
| Notes |
| 2007-07-03 15:54:51 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-28 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-28 |
Time |
15:13 |
Sent To |
B |
|
| Notes |
| 2007-06-28 15:13:32 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-04 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-04 |
Time |
11:53 |
Sent To |
B |
|
| Notes |
| 2007-06-04 11:53:41 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-02-05 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-02-05 |
Time |
18:24 |
Sent To |
|
|
| Notes |
| 2007-02-05 18:25:46 | SENT TO JULIO'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-18 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-18 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2006-12-18 15:30:32 | TO "COMM" BD#28/PLANS ON RACK/12 ROLL AND 1 BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-12-05 |
Time |
19:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-10-31 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2006-11-03 11:46:45 | 11/3/06--SUBMITTAL ROUTED TO "COMM" BD#57 W/ ORIGINAL | | | APPL. PACKAGE | | 2006-10-31 10:08:15 | (PLANS ROUTED TO INCOMING TODAY) TO "COMM" BD#57/PLANS | | | ON RACK 14 ROLLS/1 BOX--EXPEDITED PERMIT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-04 |
Time |
14:29 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-12-04 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2007-12-04 14:30:09 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | MECHANICAL SUBMITTAL | | | *** DENIED *** | | | 1) MECHANICAL PLANS WILL NEED TO BE REVISED TO SHOW | | | THIS CHANGE AND THE CHANGES FROM THE PAST TWO | | | SUBMITTALS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-30 |
Time |
14:59 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-11-30 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2007-11-30 14:59:30 | RECEIVED SUBMITTAL STATING 8" FLEX DUCT BETWEEN TWO | | | MIXING BOX'S |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-16 |
Time |
08:46 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-11-16 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2007-11-16 08:46:53 | RECIVED SUBMITTAL TO CHANGE AN 11" FLEX DUCT TO 10". |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-05 |
Time |
11:42 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-11-05 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2007-11-05 11:42:59 | MECH. REVISION TO PAGES M202, M203, AND M204. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-24 |
Time |
14:03 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-10-24 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2007-10-24 14:40:31 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | MECHANICAL REVISION | | | *** DENIED *** | | | 1) SEE PLAN PAGES M202, M203, AND M204. NEED THE | | | CORRECT JOB ADDRESS IN THE TITLE BLOCK (455 CHEERFUL | | | CT.), SEE W.P.B. AMEND. 106.1.3. | | | | | | 2)SEE PLAN PAGES M202, M203, AND M204. KITCHEN | | | EXHAUST HOOD MAY NOT DISCHARGE AT THE FRONT DOOR, SEE | | | F.B.C./R R303.6 AND F.B.C./M 501.2. | | | | | | 3)SEE PLAN PAGES M202 AND M203. BEDROOM SHOWS A | | | "CROWN MODEL "SK" PASSIVE RETURN AIR SLEEVE". PLEASE | | | SHOW SIZE OF OPENING AND SUBMIT MANUFACTURER'S | | | SPECIFICATION'S. SEE F.B.C./M 601.4. | | | | | | 4) SEE PLAN PAGE M203 (B1) LOWER FLOOR PLAN. 12X10 | | | SUPPLY AIR DUCT SHOWS A FIRE DAMPER NEAR THE AIR | | | HANDLER, PLEASE EXPLAIN OR CORRECT. IF FIRE DAMPER IS | | | TO BE INSTALLED SHOW A DETAIL ON PLAN FOR FIRE DAMPER | | | INSTALLATION, SEE F.B.C./M 607.5.3. | | | | | | 5) SEE PLAN PAGE M204. SHOWS ALL RETURN AIR TRANSFER | | | GRILLS IN THE WRONG LOCATIONS AND THE CLOTHES DRYER | | | VENT IN A CLOSET NOT NEAR THE DRYER (SEE YELLOW HIGH | | | LIGHT ON PLANS), PLEASE CORRECT. SEE F.B.C. 106.1.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-20 |
Time |
13:38 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-12-20 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-17 |
Time |
10:59 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2006-11-17 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2006-11-17 11:03:38 | *** PROVISO *** | | | 1) UNITS (A1) UPPER AND LOWER, (B1) UPPER AND LOWER, | | | RETURN AIR TRANSFER GRILLS TO MASTER BEDROOM SUITE NEED | | | TO BE 14"X 8", SEE 2004 FBC/M 601.4. | | | | | | 2) CLOTHES DRYER VENTS MAY NOT EXCEED THE | | | MANUFACTURER'S SPECIFICATION'S, PLANS SHOW THAT UNIT | | | (B1) UPPER, LOWER, AND ACCESSIBLE MAY EXCEED. | | | | | | 3) AHU CLOSET DOORS NEED TO BE LOUVERED OR GRILLS NEED | | | TO BE INSTALLED FOR RETURN AIR, SEE 2004 FBC/M 601.4. | | | | | | 4) LAUNDRY ROOM DOORS NEED TO BE LOUVERED OR GRILLS | | | NEED TO BE INSTALLED FOR COMBUSTION AIR, SEE 2004 FBC/M | | | 701.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-02-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-23 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-23 |
Time |
18:55 |
Sent To |
|
|
| Notes |
| 2008-02-23 18:55:43 | REVISION OK--SHT P310 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-12-27 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-12-27 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2006-12-27 09:42:31 | SEPARATE GAS PERMIT REQUIRED. - GAS PLANS/REQUIREMENTS | | | TO BE SUBMITTED AT THE TIME OF GAS PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-11-21 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-11-21 |
Time |
06:31 |
Sent To |
|
|
| Notes |
| 2006-11-21 07:32:24 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | NOTE: 1ST REVIEW UNDER PERMIT | | | | | | **********FROM PREVIOUS REVIEW********** | | | | | | 1. SHEETS DELETED. WILL BE SUBMITTED AT THE TIME OF | | | APPLICATION SUBMITTAL PER RESPONSE. | | | | | | 2. OK | | | | | | 3. SHT A104 DETAIL 06 SINKS SHALL COMPLY | | | WITH SECTION 11-4.24.7 FAUCETS. PLEASE | | | INDICATE COMPLIANCE ON DETAIL. | | | ****RESPONSE NOTED. NOTE REFERENCED INDICATES | | | COMPLIANCE WITH LAVS, BUT NOT SINKS. PLEASE INDICATE | | | FAUCET TYPE TO BE SUBMITTED FOR BOTH THE LAVS AND THE | | | SINKS. (LEVER- OPERATED, PUSH-TYPE ETC). | | | | | | 4. SHT A104 GENERAL NOTES II(5)(C) GRAB | | | BAR HEIGHTS SHALL BE 33" MIN. TO 36" | | | MAX. PAGE 6.5 FHA DESIGN MANUAL. | | | ****RESPONSE NOTED. NOTE NOT CORRECTED. | | | | | | 5. OK. DELETED | | | 6. OK. NOT REQUIRED FOR THIS BUILDING. | | | 7. OK. NOT REQUIRED FOR THIS BUILDING. | | | | | | 8 SHTS A201 THRU A205 INDICATE | | | SPECIFICATION "A" OR "B" AS REQUIRED ON | | | PAGES 7.34 & 7.35 FHA DESIGN MANUAL. | | | ****RESPONSE NOTED. NO ACTION TAKEN. | | | | | | 9.OK | | | | | | 10. SHT A203 AND A204 UNITS B1 & C1 | | | LOWER FLOOR REQUIRED TO MEET FHA-98 | | | DESIGN REQUIREMENTS 2ND BATHROOMS ARE | | | EXEMPT ONLY FROM MANEUVERING AND CLEAR | | | FLOOR SPACE IF SPECIFICATION "B" AND | | | SHALL SHOW THE BACKING AS WELL AS THE | | | SPACING FOR THE WATER CLOSET. (33" | | | OPENING, 15"/18" BETWEEN THE FIXTURES). | | | PLEASE SHOW ON PLANS. IF SPECIFICATION | | | 'A" THEN BATHROOM SHALL COMPLY WITH ALL REQUIREMENTS OF | | | FHA DESIGN MANUAL. | | | ****RESPONSE NOTED. NO ACTION TAKEN. (REQUIRED FOR SHT | | | A205 ALSO). | | | | | | 11. SHT A205 ADCP ACCESSIBLE UNIT PLAN NOTES LEGEND | | | SHALL CHANGE REFERENCE STANDARD TO FHA-98 AMENDMENTS. | | | ****RESPONSE NOTED. THIS COMMENT WAS BECAUSE OF THE | | | FHA-1996 NOTE AT THE BOTTOM OF THE LEGEND. RESPONSE IS | | | CORRECT IN THE FACT THAT 7%, (10 REQUIRED, 9 SHOWN), OF | | | THE UNITS ARE TO BE FULLY ACCESSIBLE. ACCESSIBLE DOES | | | NOT MEAN ANY PORTION SHALL BE ADAPTABLE AS INDICATED IN | | | SOME NOTES. ALL FIXTURES REQUIRED TO BE ACCESSIBLE | | | SHALL BE ACCESSIBLE WHEN THE UNIT IS BUILT. NOTE | | | DELETED. | | | | | | 12. SHT A205 HDCP ACCESS. UNIT PLAN | | | NOTES LEGEND:NOTE #2 SINK SHALL BE | | | ACCESSIBLE, NOT ADAPTABLE AS STATED. | | | IF UNIT IS ACCESSIBLE, THEN IT SHALL BE | | | BUILT ACCESSIBLE. SHOW CLEAR FLOOR | | | SPACE. | | | ****RESPONSE NOTED. BUT WE ARE TALKING ABOUT THE | | | ACCESSIBLE UNITS, NOT THE ADAPTABLE UNITS IN THIS | | | COMMENT. (SEE COMMENT 11 ABOVE). NOTE DELETED. | | | | | | 13. OK (UNIT LOCATION ONLY) | | | 14. OK. NOT REQUIRED FOR THIS BUILDING. | | | 15. OK. NOT REQUIRED FOR THIS BUILDING. | | | 16. OK. NOT REQUIRED FOR THIS BUILDING. | | | 17. OK. NOT REQUIRED FOR THIS BUILDING. (CHANGE | | | REFERENCE). | | | 18. OK. NOT REQUIRED FOR THIS BUILDING. | | | 19. OK. NOT REQUIRED FOR THIS BUILDING. | | | 20. OK. NOT REQUIRED FOR THIS BUILDING. | | | 21. OK. NOT REQUIRED FOR THIS BUILDING. | | | | | | 22. SHT P201 PLAN KEY NOTE #2 INDICATES | | | KITCHEN SINK ARM IS RUN UNDER THE SLAB, | | | BUT THE 3S RISER DIAGRAM ON SHT P402 | | | INDICATES THE SINK ARM IS ABOVE THE SLAB | | | PLEASE CLARIFY AND CORRELATE THE NOTES, | | | FLOOR PLAN, AND RISER DIAGRAM. SECTION | | | 106.1.1. | | | ****RESPONSE NOTED. NO ACTION TAKEN. | | | | | | 23. OK. NOTE 7 DELETED | | | 24. OK. (CHANGED FROM HB SUPPLY TO GAS PIPING) | | | 25. OK. NOT REQUIRED FOR THIS BUILDING | | | | | | 26. SHT P403 ALL WATER RISER DIAGRAMS, | | | AIR CHAMBERS ARE NOT APPROVED. PLEASE | | | DELETE FROM RISER DIAGRAMS. WATER HAMMER | | | ARRESTORS REQUIRED BY SECTION 604.9, | | | (W/M'S, D/W'S, AND ICE MAKERS), SHALL BE | | | SHOWN AND SHALL BE LOCATED NEAR THE | | | FIXTURES IN AN "EFFECTIVE RANGE", NOT IN | | | THE CEILING. PDI-WH 201 AND MANUF. | | | INSTALLATION INSTRUCTIONS. | | | ****RESPONSE NOTED. RISERFOR UNIT B1 DOES NOT REFLECT | | | THE FLOOR PLAN FOR ACCESSIBLE UNIT AT LAV & W/C. PLEASE | | | CORRELATE SECTION 106.1.1. - THE RISER DIAGRAM FOR A1 | | | UNIT UPPER/LOWER HAVE BEEN CROSSED OUT, "NOT USE", | | | INDICATED. SUBMIT A WATER RISER DIAGRAM FOR A1 UNITS. | | | | | | 27. SUBMIT A BUILDING DRAIN SANITARY | | | RISER DIAGRAM ISOMETRIC THAT REFLECTS | | | THE FLOOR PLAN FOR EACH BUILDING. | | | SECTION 106.1.5.1.3. SHOW ALL PIPE | | | SIZES, RISER LOCATIONS, TRAPS, VENTS, | | | AND DFU'S AS THEY ACCUMULATE IN THE | | | SYSTEM. | | | ****RESPONSE NOTED. SHOW CLEANOUTS REQUIRED BY SECTION | | | 708.3.3, CHANGE OF DIRECTIONGREATER THAN 45 DEGREES. | | | RISER S1 DOES NOT REFLECT THE FLOOR PLANS FOR UNITS B1 | | | & C1. SEPARATE RISERS ARE REQUIRED FOR THESE UNITS. | | | (THREE S1 RISER TYPES REQUIRED). | | | | | | 28. OK | | | 29. OK. NOT REQUIRED THIS BUILDING. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | SUBMIT ONE SET OF PLANS FROM FIRST | | | REVIEW FOR COMPARISON TO EXPEDITE 2ND | | | REVIEW. | | | | | | **************NEW COMMENTS************** | | | | | | 1B. SHTS A100 & A101 PLANS INDICATE 7% OF THE UNITS | | | SHALL BE ACCESSIBLE. 130 UNITS PROVIDED. 7% IS 9.1 | | | UNITS. ANY FRACTION OF UNITS SHALL BE ROUNDED OFF | | | UPWARDS. 10 ACCESSIBLE UNITS REQUIRED. CHART INDICATES | | | BLDG "D" 1 REQUIRED/1 PROVIDED, BUT 1 IS INDICATED IN | | | BOTH BLDGS.D1/V & D2/VIII, PLEASE CLARIFY. BLDG "E" | | | INDICATES 1 REQUIRED/1PROVIDED, BUT 1 IS INDICATED IN | | | BOTHBLDGS. E1/V & E2/V. PLEASE CLARIFY. BLDG "F" | | | INDICATES 2 REQUIRED/2PROVIDED, BUT ONLY SHOWS 1 | | | PROVIDED. PLEASE CLARIFY.PLEASE CORRELATE | | | INFORMATION, CORRECT AMOUNT OF UNITS AND CHART. SECTION | | | 106.1.1. | | | | | | 2B. SHT A200 HANDICAP ACCESSIBLE UNIT PLANS NOTES | | | LEGEND.NOTES 1, 2, 5,INDICATE "ADAPTABLE". IF UNITS | | | ARE TO BE ACCESSIBLE, THEY SHALL BE FULLY ACCESSIBLE AT | | | THE TIME THEY ARE BUILT. NOT ADAPTABLE IN THE FUTURE. | | | IF THE UNITS ARE TO BE FHA-98 COMPLIANT, THE COMPLETE | | | UNIT CAN BE ADAPTABLE. | | | NOTE "B" AT THE BOTTOM READS FAIR HOUSING ACT OF 1996. | | | PLEASE INDICATE 1998 AMENDMENTS. NOTE FUTHER STATES | | | "UNITS HEREIN DESIGNATED AS ACCESSIBLE SHALL BE FULLY | | | ADA ADAPTABLE IN ADDITION TO FAIR HOUSING COMPLIANT". | | | THIS IS NOT CORRECT. A UNIT IS EITHER FHA-98 ADAPTABLE | | | OR FULLY ACCESSIBLE. | | | | | | 3B. SHT A200UNIT PLANS GENERAL NOTES 6 INDICATES 7% | | | TO BE FULLY "ADAPTABLE" PLEASE CLARIFY. | | | | | | 4B. SHTS A203, A204, A205 SHOW THE CLEAR FLOOR SPACE AS | | | REQUIRED ON PAGE 7.43 FHA DESIGN MANUAL. | | | | | | 5B. SHT P402 SANT. RISER S1 DOES NOT REFLECT THE FLOOR | | | PLAN. (LAV ON RIGHT, TUB ON LEFT) FOR ONE FLOOR PLAN, | | | (W/C, LAV, TUB) LAYOUR ON ONE FLOOR PLAN. CORRELATE | | | RISERS & FLOOR PLANS. | | | | | | 6B. SEPARATE GAS PERMIT REQUIRED. SUBMIT THE FOLLOWING | | | INFORMATION: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. AN ISOMETRIC IS REQUIRED FOR EACH GAS | | | SYSTEM SHOWING THE PIPING FROM THE METER TO THE MOST | | | REMOTEAPPLIANCE FOR EACH UNIT. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | H. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2006-11-16 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2006-11-16 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2006-11-16 09:47:15 | LANDSCAPING PLANS SHALL BE APPROVED BEFORE CO IS | | | ISSUED. |
|
|