| Plan Review Stops For Permit 06101081 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-10-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-31 |
Time |
14:28 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-10-31 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2007-10-31 14:29:34 | BUILDING PLAN REVIEW | | | PERMIT: 06101081 | | | ADD: 2905 45TH ST | | | CONT: FIRST FLORIDA CONSTRUCTION | | | TEL: (813)881-0607 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1) PLANS HAVE WHITE OUT USED ONSHEETS2 & 4. | | | 104.2.1.3 THE BUILDING OFFICIAL | | | MAY SET STANDARDS THROUGH DEPARTMENTAL | | | POLICY STANDARDS FOR PLANS AND SPRCIFICA | | | TIONS. "NO WHITE OUT". | | | | | | 2) SHEET# 4 INDICATES EGRESS LIGHTS ON A 1000W | | | DIMMER.1006.1.2 ILLUMINATION OF MEANS OF EGRESS SHALL | | | BE CONTINUOUS DURING THE TIME THAT THE CONDITIONS OF | | | OCCUPANCY REQUIRE THAT THE MEANS OF EGRESS BE AVAILABLE | | | FOR USE. ARTIFICIAL LIGHTING SHALL BE EMPLOYED AT SUCH | | | PLACES AND FOR SUCH PERIODS OF TIME AS REQUIRED TO | | | MAINTAIN THE ILLUMINATION TO THE MINIMUM CRITERIA | | | VALUES HEREIN SPECIFIED. EXCEPTIONS: AUTOMATIC MOTION | | | SENSOR-TYPE LIGHTING SWITCHES SHALL BE PERMITTED WITHIN | | | THE MEANS OF EGRESS, PROVIDED THAT SWITCH CONTROLLERS | | | ARE EQUIPPED FOR FAIL-SAFE OPERATION, ILLUMINATION | | | TIMERS ARE SET FOR A MINIMUM 15-MINUTE DURATION AND THE | | | MOTION SENSOR IS ACTIVATED BY ANY OCCUPANT MOVEMENT IN | | | THE AREA SERVED BY THE LIGHTING UNITS. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-26 |
Time |
13:46 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-08-26 |
Time |
13:46 |
Sent To |
FIRE |
|
| Notes |
| 2007-08-26 13:58:57 | BUILDING PLAN REVIEW | | | PERMIT: 06101081 | | | ADD: 2905 45TH ST | | | CONT: FIRST FLORIDA CONSTRUCTION | | | TEL: (813)881-0607 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1) PLANS HAVE WHITE OUT USED ONSHEETS2 & 4. | | | 104.2.1.3 THE BUILDING OFFICIAL | | | MAY SET STANDARDS THROUGH DEPARTMENTAL | | | POLICY STANDARDS FOR PLANS AND SPRCIFICA | | | TIONS. "NO WHITE OUT". | | | | | | 2) SHEET# 4 INDICATES EGRESS LIGHTS ON A 1000W | | | DIMMER.1006.1.2 ILLUMINATION OF MEANS OF EGRESS SHALL | | | BE CONTINUOUS DURING THE TIME THAT THE CONDITIONS OF | | | OCCUPANCY REQUIRE THAT THE MEANS OF EGRESS BE AVAILABLE | | | FOR USE. ARTIFICIAL LIGHTING SHALL BE EMPLOYED AT SUCH | | | PLACES AND FOR SUCH PERIODS OF TIME AS REQUIRED TO | | | MAINTAIN THE ILLUMINATION TO THE MINIMUM CRITERIA | | | VALUES HEREIN SPECIFIED. EXCEPTIONS: AUTOMATIC MOTION | | | SENSOR-TYPE LIGHTING SWITCHES SHALL BE PERMITTED WITHIN | | | THE MEANS OF EGRESS, PROVIDED THAT SWITCH CONTROLLERS | | | ARE EQUIPPED FOR FAIL-SAFE OPERATION, ILLUMINATION | | | TIMERS ARE SET FOR A MINIMUM 15-MINUTE DURATION AND THE | | | MOTION SENSOR IS ACTIVATED BY ANY OCCUPANT MOVEMENT IN | | | THE AREA SERVED BY THE LIGHTING UNITS. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-09 |
Time |
06:47 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-02-09 |
Time |
06:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-22 |
Time |
15:43 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2006-11-22 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2006-11-22 16:53:30 | BUILDING PLAN REVIEW | | | PERMIT: 06101081 | | | ADD: 2905 45TH ST | | | CONT: FIRST FLORIDA CONSTRUCTION | | | TEL: (813)881-0607 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) 110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | | | | 4) 2004 FL EXISTING BLDG CODE WHAT LEVEL | | | OF CONSTRUCTION IS BEING COMPLETED? | | | | | | 5) PROVIDE THE OCCUPANT LOAD FOR THE | | | MEZZANINE AREA? ALSO PROVIDE A LIFE SAFETY | | | PLAN INDICATING THE NUMBER OF OCCUPANTS | | | AND WHICH STAIRS THEY WILL BE USING. | | | DEPENDING ON THE RESULTS OF THE QUESTIONS ABOVE THE | | | MONUMENTAL STAIRS MAY HAVE ADDITIONAL COMMENTS. | | | | | | 6) THE SECOND LEVEL OF THE MEZZANINE INDICATES VARIOUS | | | | | | CUBICLE ENCLOSURES, THE ENCLOSURES THAT ARE LOCATED | | | NEXT | | | TO THE TOP OF THE SHEET CUT OFF THE DIRECT ACCESS TO AN | | | EXIT | | | FROM THE MEZZANINE LEVEL.505.4(EXCEPTION# 2). A | | | MEZZANINE | | | HAVING TWO OR MORE MEANS OF EGRESS IS NOT REQUIRED TO | | | BE OPEN | | | TO THE ROOM IN WHICH THE MEZZANINE IS LOCATED, IF AT | | | LEAST ONE OF | | | THE MEANS OF EGRESS PROVIDES DIRECT ACCESS TO AN EXIT | | | FROM THE | | | MEZZANINE LEVEL. | | | | | | 7) RAISED SEATING AREA BY THE NEW GLASS WALL, A NEW | | | STAIR TO THIS AREA | | | IS BEING ALTERED, 11-4.1.6(1)(B) ACCESSIBLE BUILDINGS, | | | ALTERAATIONS: | | | IF EXESTING ELEMENTS, SPACES, OR COMMON AREAS ARE | | | ALTERED, THEN EACH | | | SUCH ALTERED ELEMENT, SPACE, FEATURE,OR AREA SHALL | | | COMPLY WITH THE APPLICABLE | | | PROVISIONS OF 11-4.1.1 TO 11-4.1.3. MINIMUM | | | REQUIREMENTS FOR NEW CONSTRUCTION. | | | PROVIDE VERTICAL ACCESSIBILITY TO THE RAISED SEATING | | | AREA. | | | 11-4.1.2 VERTICAL ACCESSIBILITY, | | | NOTHING IN THIS CODE SHALL BE CONSTRUED | | | TO RELIEVE THE OWNER OF ANY BUILDING, | | | SSTRUCTURE OR FACILITY FROM THE DUTY TO | | | PROVIDE VERTICAL ACCESSIBILITY TO ALL | | | LEVELS ABOVE OR BELOW THE OCCUPIAABLE | | | GRADE LEVEL. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-28 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-28 |
Time |
13:52 |
Sent To |
FIRE |
|
| Notes |
| 2008-01-28 13:54:25 | REDLINED PLANS,NO LIGHTING LEVELS AS STATED ON PLANS | | | SHALL BE PERMITTED TO DIM BELOW THE MINIMUM LEVELS PER | | | LS 101 7.8 AND 7.9 | | | THIS IS STATED ON PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-03 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-03 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2007-12-03 16:43:58 | | | | ** DENIED REVIEW ** | | | | | | ** PLEASE SEE THERE ARE NOTES FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING ALONG WITH NEW | | | NOTES. | | | | | | | | | | | | 1) NOTE: PLEASE SEE THE PLANS ARE STILL QUOTING | | | LIGHTING CONTROLS ARE TO MEET CHAPTER 13 IN LIEU OF | | | ACTUAL DETAILS REQUIRED. | | | 13-415.1.ABC.1.2. | | | | | | 2) NOTE: PLEASE SEE THE ELECTRICAL PLANS DO NOT SHOW | | | THE NEW LIGHTING, CIRCUITING, OR CONTROLS FOR STAIR | | | LIGHTS AND EMERGENCY LIGHTING WHICH ARE ON PHOTO-METRIC | | | SHEET PROVIDED. | | | PLEASE CORRELATE ELECTRICAL FOR ALL LIGHTING. | | | PLEASE SHOW CONTROLS AND CIRCUITING. PLEASE BE SURE TO | | | SEE NEC 700.12E FOR CIRCUITING OF EMERGENCY LIGHTING | | | FIXTURES. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-27 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-27 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2007-10-27 11:47:45 | ** DENIED REVISION 3RD TIME ** | | | | | | 1) NOTE: PLEASE SEE THERE ARE STILL COMMENTS FROM THE | | | *TWO* PREVIOUS REVIEWS WHICH ARE THE SAME. | | | PLEASE KNOW THAT QUOTING THE CODE ON PLANS IN LIEU OF | | | SHOWING CODE COMPLIANCE DETAILS IS NOT PERMITTED. | | | ** THE PLANS WERE LOOKED OVER BEFORE SUBMITTING WITH | | | THE GC AND WERE TOLD THE PLANS HAD NOT BEEN CORRECTED. | | | THE PLANS WERE SUBMITTED FOR REVIEW ANYWAY FOR CODE | | | COMPLIANCE REVIEW. | | | | | | 2) NOTE: PLEASE SEE PLANS ARE STILL DO NOT INDICATE THE | | | LIGHTING CONTROLS AS REQUIRED PER 13-415.1.ABC .1.1, | | | AND 13-415.1.ABC .1.2. 13-103 | | | PLEASE KNOW THAT QUOTING THE CONTROLS ARE TO MEET CODE | | | IS NOT PROVIDING THE INFORMATION AS NEEDED. | | | | | | 3) NOTE: PLEASE SEE THE PLANS STILL INDICATE DIMMERS ON | | | THE EGRESS LIGHTING PATHS. PLEASE SEE THAT NO | | | INFORMATION WAS SUBMITTED ON HOW THE MINIMUM LIGHTING | | | LEVELS WILL BE MAINTAINED. PLEASE SEE THE PLANS DO NOT | | | INDICATE ANY LIGHTING LEVELS AS PREVIOUSLY REQUESTED. | | | THESE ARE ALL *MINIMUM* LIGHTING LEVELS REQUIRED FOR | | | LIFE SAFETY UNDER NORMAL AND EMERGENCY CONDITIONS. | | | PLEASE SEE THE 2003 LIFE SAFETY CODE NFPA-101 7.8 AND | | | 7.9. | | | PLEASE SHOW THE PHOTO-METRIC LEVELS BASED ON FIXTURES | | | TO BE INSTALLED. | | | PLEASE PROVIDE DETAILED INFORMATION WHICH WILL | | | SPECIFICALLY SHOW HOW THE MINIMUM LIGHTING LEVELS ARE | | | MET. | | | | | | 4) NOTE: PLEASE SEE THAT AS THESE COMMENTS WHICH WERE | | | ON BOTH PREVIOUS REVIEWS. IF THESE COMMENTS ARE NOT | | | ADDRESSED ON THE FOLLOWING REVIEW, THIS OFFICE IS BEING | | | LEFT WITH NO CHOICE BUT TO FORWARD DOCUMENTS/PLANS TO | | | THE FLORIDA BOARD OF ARCHITECTS AND STATE BOARD OF | | | ARCHITECTS LEGAL COUNSEL FOR REVIEW. | | | AS STATED ON ALL PREVIOUS REVIEWS, IF THERE ARE ANY | | | QUESTIONS TO PLEASE CONTACT THIS OFFICE TO GO OVER THE | | | COMMENTS IF THEY ARE NOT UNDERSTOOD. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-23 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-23 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2007-08-23 15:48:48 | | | | *** DENIED *** | | | | | | | | | 1) NOTE: PLEASE SEE THE PLANS STILL INDICATE A NOTE | | | WHICH STATES LIGHTING CONTROL DEVICES TO COMPLY WITH | | | CHAPTER 13, HOWEVER MAY NOT QUOTE THE CODE IN LIEU OF | | | SHOWING THE REQUIRED DETAIL FOR MINIMUM DESIGN. | | | 13-415.1.ABC.1.1, .1.2 | | | | | | 2) NOTE: PLEASE SEE PLANS NOW CONTAIN WHITE-OUT AND | | | HAND WRITTEN CHANGES WHICH IS PROHIBITED UNDERFS | | | 481.221 | | | | | | 3 NOTE:SAME NOTE S PREVIOUS REVIEW. PLEASE SUBMIT | | | PHOTO-METRICS FOR THEEGRESS STAIRS UNDER NORMAL AND | | | UNDER EMERGENCY CONDITIONS. PLEASE SEE THAT EGRESS | | | PATHS SUCH AS HALLWAYS AND STAIRWAY SHALL NOT CONTAIN | | | DIMMERS WHICH CAN PLACE THE MINIMUM LIGHTING LEVELS | | | BELOW THAT OF THE LIFE SAFETY CODE. | | | PLANS STILL INDICATE DIMMERS ON PLANS WHICH ARE | | | STRICTLY PROHIBITED. PLEASE KNOW ONCE THE MINIMUM | | | LEVELS OF FOOT CANDLES ARE INDICATED, DEPENDING ON THE | | | TYPE OF DIMMER, DIMMING MAY BE POSSIBLE IF THE MINIMUM | | | LEVELS ARE STILL MAINTAINED AT THE LOWEST POINT OF | | | DIMMING. THIS IS A LIFE SAFETY ISSUE. | | | PLEASE INDICATE THE LOCATIONS OF THE EXISTING EMERGENCY | | | LIGHTS ON PLANS. PLANS STATE A NOTE WHICH DIRECTS | | | CONTRACTOR TO ADD IF NOT EXISTING. | | | ONE AGAIN PLANS ARE REQUIRED TO SHOW IN DETAIL THE | | | *MINIMUM* REQUIRED FOR LIFE SAFETY. | | | PLEASE SEE NFPA-101 7.8.1.3, 7.9.2.2 | | | ** PLEASE SEEPOSSIBLE COMMENTS FROM THE FIRE MARSHAL | | | | | | 3) NOTE: PLEASE PROVIDE REVISED PANEL SCHEDULES ALONG | | | WITH CIRCUITING ON PLANS TO CORRELATE WITH SAID PANEL | | | SCHEDULES. | | | 408.4, 310.16, 240.4. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 4) NOTE: PLEASE SEE 13-415.1.ABC.1.1, .1.2, 13-101 AS | | | NEW LIGHTING CONTROL DEVICES NOW BEING CHANGED OUT ARE | | | REQUIRED TO MEET CHAPTER 13. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-21 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-21 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2007-06-21 16:45:38 | ** UNSAT ** | | | | | | ** REVISIONS | | | | | | 1) NOTE: PLEASE SEE THE SEAL IN USE BY THE ARCHITECT IS | | | NOT VALID UNDER RULING UNDER THE FAC 61G1-16.002. | | | PLEASE SEE THIS WAS MISSED ON PREVIOUS REVIEWS OF PLANS | | | AND NEW SEAL AS REQUIRED UNDER FAC AND FS 481.221 MUST | | | BE OBTAINED. | | | PLEASE SEE SHEET ATTACHED FROM STATE WEB SITE. | | | | | | 2) NOTE: PLEASE PROVIDE PHOTO-METRICS FOR EGRESS STAIRS | | | UNDER NORMAL AND UNDER EMERGENCY CONDITIONS. PLEASE SEE | | | THAT EGRESS PATHS SUCH AS HALLWAYS AND STAIRWAY SHALL | | | NOT CONTAIN DIMMERS WHICH CAN PLACE THE MINIMUM | | | LIGHTING LEVELS BELOW THAT OF THE LIFE SAFETY CODE. | | | PLEASE SEE NFPA-101 7.8.1.3, 7.9.2.2 | | | ** PLEASE SEE COMMENTS FROM THE FIRE MARSHAL | | | | | | 3) NOTE: PLEASE PROVIDE REVISED PANEL SCHEDULES ALONG | | | WITH CIRCUITING ON PLANS TO CORRELATE WITH SAID PANEL | | | SCHEDULES. | | | 408.4, 310.16, 240.4. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 4) NOTE: PLEASE SEE 13-415.1.ABC.1.1, .1.2, 13-101 AS | | | NEW LIGHTING CONTROL DEVICES NOW BEING CHANGED OUT ARE | | | REQUIRED TO MEET CHAPTER 13. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-03 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-03 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2007-02-03 14:48:01 | DOES NOT INCLUDE ANY LV SCOPE OF WORK, ANY LOW VOLTAGE | | | WILL BE UNDER A SEPARATE PERMIT , PLANS AND FEES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-03 |
Time |
19:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-03 |
Time |
19:45 |
Sent To |
|
|
| Notes |
| 2006-11-03 19:58:51 | *** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE PLANS CONTAIN A RAISED SEAL OVER | | | "PHOTO-COPIED" SIGNATURES FOR THE ARCHITECT OF RECORD. | | | PLEASE SEE FS 481.221 WHICH REQUIRES AN ORIGINAL | | | SIGNATURE. | | | PLEASE KNOW THIS COMMENT HAS BEEN MADE TO THIS SAME | | | DESIGN PROFESSIONAL ON PREVIOUS PROJECTS AND ONE SET OF | | | PLANS WILL BE RETAINED AND PLACED IN PREVIOUS FILE FOR | | | SAID ARCHITECT. PLANS MAY BE FORWARDED TO THE STATE. | | | | | | 2) NOTE: PLEASE SEE PLANS MENTIONS THE "DJ" BOOTH BEING | | | RELOCATED, PLEASE CALRIFY ANY RELOCATION OF ELECTRICAL | | | SYSTEMS , LIGHTING CONTROLS , LV WIRING ETC. | | | PLEASE KNOW ALL LV WIRING WILL BE REQUIRED TO BE | | | PERMITTED. | | | | | | | | | ** PLEASE SUBMIT TEH ABOVE INFORMATION FOR REVIEW AND | | | PLEASE SEE ANY COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT PLANS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLANREVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2008-02-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-04 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-04 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2008-02-04 14:07:47 | *****APPROVED***** | | | | | | PLAN SHEETS 5 AND 6 WERE STAMPED, INITIALED, AND | | | DATED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-06 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-06 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2007-11-06 10:52:52 | *****DENIED***** | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE REVIEWS | | | STILL NEED TO BE REVIEWED | | | | | | | | | 1.LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003 | | | EDITION. THE PLANS ARE TO BE SUBMITTED WITH NO INK, | | | PENCIL,OR BLACK/WHITE-OUTED MARKINS | | | | | | 2.CONSTRUCTION, ALTERATION, OR DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241.JOB SITE SHALL BE CLEANED | | | OF CONSTRUCTION DEBRIS DAILY.PLEASE ACKNOWLEDGE ON AN | | | APPROPIATE PLAN SHEET | | | | | | 4.PLEASE SEE ELECTRICAL REVIEW COMMENTS REGARDING | | | REQUIRED LIGHTING IN AREAS OF MEANS OF EGRESS. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-28 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-28 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2007-08-28 10:54:57 | *****DENIED***** | | | THE FOLLOWING COMMENTS ARE A COMPILATION OF THE | | | PREVIOUS FIRE REVIEWS: | | | | | | | | | 1.LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 2.CONSTRUCTION, ALTERATION, OR DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241.JOB SITE SHALL BE CLEANED | | | OF CONSTRUCTION DEBRIS DAILY. | | | | | | 3.WILL THE SCOPE OF WORK IMPACT EXISTING FIRE | | | SPRINKLER OR FIRE ALARM SYSTEMS.IF SO. SEPARATE PLANS | | | AND PERMIT WILL BE REQUIRED FOR THE REMODEL. | | | | | | 4.PLEASE SEE ELECTRICAL REVIEW COMMENTS REGARDING | | | REQUIRED LIGHTING IN AREAS OF MEANS OF EGRESS. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-06-27 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-06-27 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2007-06-27 12:55:24 | ***DENIED*** | | | | | | 1) PLEASE SEE ELECTRICAL REVIEW COMMENTS REGARDING SEAL | | | REQUIREMENTS AND REQUIRED LIGHTING IN AREAS OF MEANS OF | | | EGRESS. | | | | | | 2) THE LAST FIRE REVIEW WAS PASSED PROVISO, HOWEVER TWO | | | (2) COMMENTS WERE INCLUDED WITH NO RESPONSE NOTED. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-14 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-14 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2007-02-14 13:04:10 | *****PROVISO***** | | | | | | | | | | | | | | | 1.LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 2.CONSTRUCTION, ALTERATION, OR DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241.JOB SITE SHALL BE CLEANED | | | OF CONSTRUCTION DEBRIS DAILY. | | | | | | 3.THE WORK WILL NOT IMPACT EXISTING FIRE SPRINKLER OR | | | FIRE ALARM SYSTEMS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-12-21 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-12-21 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2006-12-21 15:14:27 | ***DENIED*** | | | | | | 1) PLEASE SEE ELECTRICAL COMMENT #1 AND MAKE | | | APPROPRIATE CORRECTIONS. | | | | | | 2) LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 3) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. JOB SITE SHALL BE CLEANED OF | | | CONSTRUCTION DEBRIS DAILY. | | | | | | 4) PLEASE SHOW LOCATIONS (NEW OR EXISTING) OF REQUIRED | | | 2A-10B,C RATED FIRE EXTINGUISHERS. SPACING TO BE AT | | | DISTANCES NOT TO EXCEED 75' TRAVEL DISTANCE. | | | | | | 5) WILL WORK IMPACT EXISTING FIRE SPRINKLER OR FIRE | | | ALARM SYSTEMS? | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | (561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-25 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-25 |
Time |
10:23 |
Sent To |
E |
|
| Notes |
| 2008-01-25 10:24:09 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-27 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-27 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2007-12-03 09:38:48 | TO "BOB"#4 | | 2007-11-27 16:52:56 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-19 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-19 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2007-10-27 11:21:38 | TO BOB BOARD SPACE #6 | | 2007-10-19 12:23:23 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-07 |
Time |
20:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-07 |
Time |
20:56 |
Sent To |
|
|
| Notes |
| 2007-08-23 13:29:47 | TO "BOB"#6 | | 2007-08-07 20:56:32 | WAITING FOR COMM BOARD. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-19 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-19 |
Time |
09:55 |
Sent To |
E |
|
| Notes |
| 2007-06-19 09:55:44 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-02 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-02 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2007-02-02 09:04:56 | TO "BOB"#17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-12-21 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-11-01 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2006-11-01 16:58:13 | TO "COMM" BD#55 | | 2006-11-01 16:39:06 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-24 |
Time |
09:32 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-08-24 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2007-08-24 09:35:13 | PLAN STATES EXHAUST CHANGE OUT OF SECOND FLOOR A/C | | | SYSTEM. WILL NEED TO APPLY FOR A MECHANICAL PERMIT | | | BEFORE REPLACING SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-25 |
Time |
08:46 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-06-25 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2007-06-25 08:55:17 | *** DENIED *** | | | 1) SEE SECOND PAGE OF PLANS UPPER LEVEL STATES 'NO | | | MECHANICAL CHANGES' BUT THE PLAN ALSO SHOWS 'NEW A/C 5 | | | TON'. IF ONLY AN EXACT CHANGE-OUT A MECHANICAL PERMIT | | | MAY BE APPLIED FOR AT A LATER DATE, PLEASE STATE SO ON | | | PLANS OR CORRECT PLANS. | | | | | | 2) SEE ELECTRICAL REVIEW NOTE #1 REGARDING SEAL, PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|