| Plan Review Stops For Permit 06101065 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-09 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-09 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-06 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-06 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2006-11-06 10:44:21 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE TYPE OF CONSTRUCTION FOR THE BUILDING | | | BASED ON THE 2004 FBC DESIGNATION. | | | | | | 3) SPECIFY THE LEVEL OF ALTERATION AS DEFINED BY THE | | | 2004 FBC EXISTING BUILDING CODE CHAPTER 3. NOTE: THIS | | | IS A LEVEL 2. | | | | | | 4) THE OCCUPANT LOAD FOR A 1504 SQFT BUSINESS OCCUPANCY | | | IS 16 PERSONS. PLEASE CORRECT. | | | | | | 5) SPECIFY THE DOOR SIZES ON THE PLANS FOR EGRESS AND | | | ACCESSIBILITY PURPOSES. SEE FBC 1808.1.1, 11-4.13.5 AND | | | 11-4.1.6. | | | | | | 6) THE DOOR INTO ROOM 101 IS REQUIRED TO HAVE A MINIMUM | | | OF 18" ON THE PULL SIDE OF THE DOOR AT THE LATCH SIDE. | | | SEE FBC 11-4.13.6. | | | | | | 7) SPECIFY THE DOOR HARDWARE FOR EGRESS AND | | | ACCESSIBILITY REQUIREMENTS. SEE FBC 1013.2, 11-4.13.9 | | | AND 11-4.1.6. | | | | | | 8) INDICATE THE USE OF ROOM 103, THROUGH WHICH EGRESS | | | IS INDICATED. SEE FBC 1013.2. EGRESS THROUGH | | | INTERVENING SPACES. | | | EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH | | | ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE | | | SUCH ADJOINING ROOMS OR AREAS ARE ACCESSORY TO THE AREA | | | SERVED; ARE NOT A HIGH-HAZARD OCCUPANCY AND PROVIDE A | | | DISCERNIBLE PATH OF EGRESS TRAVEL TO AN EXIT. EGRESS | | | SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS | | | OR SPACES USED FOR SIMILAR PURPOSES. AN EXIT ACCESS | | | SHALL NOT PASS THROUGH A ROOM THAT CAN BE LOCKED TO | | | PREVENT EGRESS. MEANS OF EGRESS FROM DWELLING UNITS OR | | | SLEEPING AREAS SHALL NOT LEAD THROUGH OTHER SLEEPING | | | AREAS, TOILET ROOMS OR BATHROOMS. | | | | | | 9) THE EXIT LIGHT IN ROOM 102 IS NOT SPECIFIED ON THE | | | PLANS ON SHEET A1. | | | | | | 10) FAC 61G1-16.004 REQUIRES THE PRINTED NAME OF THE | | | PERSON SEALING THE DOCUMENT TO APPEAR IN THE TITLE | | | BLOCK. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-21 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-21 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2006-12-21 16:30:46 | NEW SHEETS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-03 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-03 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2006-11-03 14:49:13 | IN ELEC |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-26 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-26 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-16 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-11-16 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2006-11-16 11:11:01 | *****UNSAT***** | | | | | | | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 2.INTERIOR DEMOLITION AND BUILDOUT OPERATIONS SHALL | | | NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | | PROPERTY OR VICINITY THEREOF. | | | | | | 3.AS PER NFPA 101 - 2003 EDITION - CHAPTER 10, SINCE | | | THE STRUCTURE IS AN UNSPRINKLERED BUILDING ALL INTERIOR | | | FINISH SHALL BE CLASS "A" OR CLASS "B".(SEE SHEET A-1 | | | FINISH SCHEDULE NOTE #6) | | | | | | 4.FIRE EXTINGUISHER(S) SHALL BE RATED 2A-10BC. | | | | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | | INCLUDE A RESPONSE LETTER HOW/WHERE EACH ITEM WAS | | | ADDRESSED. | | | | | | | | | CAPT. MICHAEL WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-05 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-05 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2006-12-21 09:34:41 | TO "BOB"#14 | | 2006-12-05 14:33:19 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-18 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-30 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2006-11-03 14:42:10 | TO "BOB"#5 | | 2006-10-30 10:04:43 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-09 |
Time |
14:10 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-01-09 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-22 |
Time |
08:13 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-22 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2006-12-22 08:22:38 | *** DENIED *** | | | 1) NEED TO SHOW THE SIZE OF THE RETURN AIR DUCT FROM | | | ROOM 102 BACK TO THE AIR HANDLER UNIT, PLEASE BE AWARE | | | THAT THIS DUCT MUST BE LARGE ENOUGH TO RETURN ALL THE | | | AIR FROM THE RETURN AIR TRANSFER DUCTS TO THE AIR | | | HANDLER UNIT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-06 |
Time |
12:12 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-06 |
Time |
12:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-18 |
Time |
06:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-18 |
Time |
06:09 |
Sent To |
|
|
| Notes |
| 2006-11-18 06:10:28 | NO PLUMBING WORK SHOWN ON THESE PLANS. |
|
|