Plan Review Details - Permit 06101065
Plan Review Stops For Permit 06101065
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-01-09 Cont ID  
Sent By rmcdouga Date 2007-01-09 Time 07:54 Rev Time 0.00
Received By rmcdouga Date 2007-01-09 Time 07:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-11-06 Cont ID  
Sent By rmcdouga Date 2006-11-06 Time 08:11 Rev Time 0.00
Received By rmcdouga Date 2006-11-06 Time 07:04 Sent To  
Notes
2006-11-06 10:44:21DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SPECIFY THE TYPE OF CONSTRUCTION FOR THE BUILDING
 BASED ON THE 2004 FBC DESIGNATION.
  
 3) SPECIFY THE LEVEL OF ALTERATION AS DEFINED BY THE
 2004 FBC EXISTING BUILDING CODE CHAPTER 3. NOTE: THIS
 IS A LEVEL 2.
  
 4) THE OCCUPANT LOAD FOR A 1504 SQFT BUSINESS OCCUPANCY
 IS 16 PERSONS. PLEASE CORRECT.
  
 5) SPECIFY THE DOOR SIZES ON THE PLANS FOR EGRESS AND
 ACCESSIBILITY PURPOSES. SEE FBC 1808.1.1, 11-4.13.5 AND
 11-4.1.6.
  
 6) THE DOOR INTO ROOM 101 IS REQUIRED TO HAVE A MINIMUM
 OF 18" ON THE PULL SIDE OF THE DOOR AT THE LATCH SIDE.
 SEE FBC 11-4.13.6.
  
 7) SPECIFY THE DOOR HARDWARE FOR EGRESS AND
 ACCESSIBILITY REQUIREMENTS. SEE FBC 1013.2, 11-4.13.9
 AND 11-4.1.6.
  
 8) INDICATE THE USE OF ROOM 103, THROUGH WHICH EGRESS
 IS INDICATED. SEE FBC 1013.2. EGRESS THROUGH
 INTERVENING SPACES.
 EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH
 ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE
 SUCH ADJOINING ROOMS OR AREAS ARE ACCESSORY TO THE AREA
 SERVED; ARE NOT A HIGH-HAZARD OCCUPANCY AND PROVIDE A
 DISCERNIBLE PATH OF EGRESS TRAVEL TO AN EXIT. EGRESS
 SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS
 OR SPACES USED FOR SIMILAR PURPOSES. AN EXIT ACCESS
 SHALL NOT PASS THROUGH A ROOM THAT CAN BE LOCKED TO
 PREVENT EGRESS. MEANS OF EGRESS FROM DWELLING UNITS OR
 SLEEPING AREAS SHALL NOT LEAD THROUGH OTHER SLEEPING
 AREAS, TOILET ROOMS OR BATHROOMS.
  
 9) THE EXIT LIGHT IN ROOM 102 IS NOT SPECIFIED ON THE
 PLANS ON SHEET A1.
  
 10) FAC 61G1-16.004 REQUIRES THE PRINTED NAME OF THE
 PERSON SEALING THE DOCUMENT TO APPEAR IN THE TITLE
 BLOCK.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-21 Cont ID  
Sent By dpalmer Date 2006-12-21 Time 16:36 Rev Time 0.00
Received By dpalmer Date 2006-12-21 Time 16:30 Sent To  
Notes
2006-12-21 16:30:46NEW SHEETS

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-11-03 Cont ID  
Sent By dpalmer Date 2006-11-03 Time 18:02 Rev Time 0.00
Received By dpalmer Date 2006-11-03 Time 14:48 Sent To  
Notes
2006-11-03 14:49:13IN ELEC

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-12-26 Cont ID  
Sent By mawillia Date 2006-12-26 Time 09:23 Rev Time 0.00
Received By mawillia Date 2006-12-26 Time 09:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-11-16 Cont ID  
Sent By mawillia Date 2006-11-16 Time 10:49 Rev Time 0.00
Received By mawillia Date 2006-11-16 Time 10:49 Sent To  
Notes
2006-11-16 11:11:01*****UNSAT*****
  
  
  
  
 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2.INTERIOR DEMOLITION AND BUILDOUT OPERATIONS SHALL
 NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID
 PROPERTY OR VICINITY THEREOF.
  
 3.AS PER NFPA 101 - 2003 EDITION - CHAPTER 10, SINCE
 THE STRUCTURE IS AN UNSPRINKLERED BUILDING ALL INTERIOR
 FINISH SHALL BE CLASS "A" OR CLASS "B".(SEE SHEET A-1
 FINISH SCHEDULE NOTE #6)
  
 4.FIRE EXTINGUISHER(S) SHALL BE RATED 2A-10BC.
  
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING,
 INCLUDE A RESPONSE LETTER HOW/WHERE EACH ITEM WAS
 ADDRESSED.
  
  
 CAPT. MICHAEL WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-12-05 Cont ID  
Sent By adarroug Date 2006-12-05 Time 14:33 Rev Time 0.00
Received By adarroug Date 2006-12-05 Time 14:33 Sent To  
Notes
2006-12-21 09:34:41TO "BOB"#14
2006-12-05 14:33:19WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-11-18 Cont ID  
Sent By jleech Date 2006-11-18 Time 06:14 Rev Time 0.00
Received By jleech Date 2006-10-30 Time 10:04 Sent To  
Notes
2006-11-03 14:42:10TO "BOB"#5
2006-10-30 10:04:43WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-01-09 Cont ID  
Sent By tgordon Date 2007-01-09 Time 14:10 Rev Time 0.30
Received By tgordon Date 2007-01-09 Time 14:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-12-22 Cont ID  
Sent By tgordon Date 2006-12-22 Time 08:13 Rev Time 0.30
Received By tgordon Date 2006-12-22 Time 08:13 Sent To  
Notes
2006-12-22 08:22:38*** DENIED ***
 1) NEED TO SHOW THE SIZE OF THE RETURN AIR DUCT FROM
 ROOM 102 BACK TO THE AIR HANDLER UNIT, PLEASE BE AWARE
 THAT THIS DUCT MUST BE LARGE ENOUGH TO RETURN ALL THE
 AIR FROM THE RETURN AIR TRANSFER DUCTS TO THE AIR
 HANDLER UNIT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-11-06 Cont ID  
Sent By tgordon Date 2006-11-06 Time 12:12 Rev Time 0.30
Received By tgordon Date 2006-11-06 Time 12:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-11-18 Cont ID  
Sent By jleech Date 2006-11-18 Time 06:09 Rev Time 0.00
Received By jleech Date 2006-11-18 Time 06:09 Sent To  
Notes
2006-11-18 06:10:28NO PLUMBING WORK SHOWN ON THESE PLANS.