| Plan Review Stops For Permit 06101056 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-04 |
Time |
07:52 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-09-04 |
Time |
07:52 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-27 |
Time |
13:18 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-08-27 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-28 |
Time |
14:41 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-06-28 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2007-06-28 14:41:55 | PERMIT: 06101056 | | | ADD: 501 VILLAGE BLVD | | | CONT: MCGOWAN BUILDERS | | | TEL: (646)533-0342 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW | | | ACTION: DENIED | | | | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) SHEET G1.1 BUILDING CODE SUMMARY PLEASE CORRECT | | | BUILDING TYPE: IVTABLE 503, TABLE 601 AND 602.4 IV IS | | | CONSIDERED HEAVY TIMBER . | | | | | | 4) 2ND REQUEST WCW ENGINEERS, INC WILL REQUIRE A | | | CERTIFICATE OF AUTHORIZATION FOR THEIR FIRM. THE NUMBER | | | SUBMITTED F06000007816 MAY BE THE FL CORP NUMBER BUT | | | THIS IS NOT THE CERTIFICATE OF AUTHORIZATION THAT IS | | | REQUIRED TO BE REGISTERED WITH DEPARTMENT OF BUSSINESS | | | AND PROFESSIONAL REGULATION. | | | 471.023 F.S.CERTIFICATE OF AUTHORIZATION.THE TITLE | | | BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER PRACTICING UNDER | | | A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING | | | SERVICES, SHALL INCLUDE THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY BE ADDED BY | | | HAND. | | | | | | 5) COMMENT# 6 FROM THE PREVIOUS REVIEW, DEALS WITH THE | | | RAMP FROM THE FREE WEIGHT AREA, RESPONCE INDICATED THE | | | RAMP IS LESS THAN 72" LONG WHERE AS WHEN SCALED OUT | | | USING THE 1/8" SCALE | | | IT INDICATES THE LENGTH TO BE 9'-0". PLEASE CORRECT THE | | | DRAWING. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-30 |
Time |
10:11 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-03-30 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2007-03-30 10:23:52 | BUILDING PLAN REVIEW | | | PERMIT: 06101056 | | | ADD: 501 VILLAGE BLVD | | | CONT: MCGOWAN BUILDERS | | | TEL: (646)533-0342 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) SHEET G1.1 BUILDING CODE SUMMARY PLEASE CORRECT | | | BUILDING TYPE: IVTABLE 503, TABLE 601 AND 602.4 IV IS | | | CONSIDERED HEAVY TIMBER . | | | | | | 4) 2ND REQUEST WCW ENGINEERS, INC WILL REQUIRE A | | | CERTIFICATE OF AUTHORIZATION FOR THEIR FIRM. THE NUMBER | | | SUBMITTED F06000007816 MAY BE THE FL CORP NUMBER BUT | | | THIS IS NOT THE CERTIFICATE OF AUTHORIZATION THAT IS | | | REQUIRED TO BE REGISTERED WITH DEPARTMENT OF BUSSINESS | | | AND PROFESSIONAL REGULATION. | | | 471.023 F.S.CERTIFICATE OF AUTHORIZATION.THE TITLE | | | BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER PRACTICING UNDER | | | A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING | | | SERVICES, SHALL INCLUDE THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY BE ADDED BY | | | HAND. | | | | | | 5) COMMENT# 6 FROM THE PREVIOUS REVIEW, DEALS WITH THE | | | RAMP FROM THE FREE WEIGHT AREA, RESPONCE INDICATED THE | | | RAMP IS LESS THAN 72" LONG WHERE AS WHEN SCALED OUT | | | USING THE 1/8" SCALE | | | IT INDICATES THE LENGTH TO BE 9'-0". PLEASE CORRECT THE | | | DRAWING. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-28 |
Time |
09:39 |
Rev Time |
6.75 |
| Received By |
jwitmer |
Date |
2006-11-27 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2006-11-28 11:18:49 | BUILDING PLAN REVIEW | | | PERMIT: 06101056 | | | ADD: 501 VILLAGE BLVD | | | CONT: MCGOWAN BUILDERS | | | TEL: (646)533-0342 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3A)CORRECTION SHEET G1.1 BUILDING SUMMARY NOTES: 2004 | | | FLORIDA BUILDING CODE WITH 2004 WEST PALM BEACH | | | ADMINISTRATIVE AMENDMENTS | | | 2004 EXISTING BUILDING CODE | | | | | | 3B) 2004 EXISTING BUILDING CODE WHAT LEVEL OF | | | ALTERATIONS? | | | | | | 4) THE P & E TITLE BLOCKS HAVE WCW ENGINEERS, INC IN | | | THE | | | TITLEBLOCK BUT THERE IS NO CERTIFICATE OF AUTHORIZATION | | | FOR THE FIRM.) 61G15-23.002(2)FL. ADMIN. CODE. | | | PLANS SIGNED & SEALED BY A PROFESSIONAL | | | ENGINEER SHALL INCLUDE EITHER THE NAME, | | | ADDRESS AND LICENSE NUMBER OF THE | | | ENGINEER OR, THE NAME AND LICENSE NUMBER | | | OF THE ENGINEER AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | | OF THE ENGINEERING BUSINESS THROUGH | | | WHICH THE ENGINEER IS PRACTICING | | | (471.025 F.S. AND 471.023 F.S.). | | | | | | 5) SHEET A1.1 INDICATES THE USE OF A RAMP TO GAIN | | | ENTRY | | | | | | INTO THE CARIDO AREA, BUT NO HANDRAILS ARE INDICATED. | | | THERE IS A CUT SECTION | | | DETAIL# 7 OF SHEET A6.2 BUT NO INDICATION OF | | | HANDRAILS. | | | 11.4.8.5. HANDRAILS: IF A RAMP HAS | | | A RISE GREATER THAN 6" OR A HORIZONTAL | | | PROJECTION GREATER THAN 72", THEN IT | | | SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | 6) SHEET A1.1 ALSO INDICATES THE USE OF A RAMP | | | IN THE FREE WEIGHTS AREA, PLEASE INDICATE | | | THE USE OF HANDRAILS, | | | 11.4.8.5. HANDRAILS: IF A RAMP HAS | | | A RISE GREATER THAN 6" OR A HORIZONTAL | | | PROJECTION GREATER THAN 72", THEN IT | | | SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | 7)A1.1 RECEPTION DESK, PLANS DO NOT PROVIDE DETAILS | | | FOR ACCESSIBILITY: | | | 11-4.32.4 HEIGHT OF TABLES OR COUNTERS . | | | THE TOPS OF ACCESSIBLE TABLES AND COUNTERS SHALL BE | | | FROM 28 INCHES | | | TO 34 INCHES (710 MM TO 865 MM) ABOVE THE FINISH FLOOR | | | OR GROUND. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-31 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-31 |
Time |
12:06 |
Sent To |
B |
|
| Notes |
| 2007-08-31 14:45:06 | ELEC OK, STAMPED, SENT TO BUILDING REVIEWER AS THERE | | | ARE SHEETS IN SETS WHICH ARE NEW/NOT BEEN STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-23 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-23 |
Time |
13:31 |
Sent To |
I |
|
| Notes |
| 2007-07-23 14:49:15 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE THE REVISED ENERGY CALCULATIONS | | | SUBMITTED ARE NOT SEALED BY THE ENGINEER OF RECORD. | | | PLEASE SEE THE PLANS STILL CONTAIN THE OLD ENERGY | | | CALCULATIONS ATTACHED DOWN THE LEFT HAND SIDE OF THE | | | PLANS. | | | PLEASE BE SURE NOT TO ATTACH ANY SUPPORTING DOCUMENTS | | | DOWN THE LEFT HAND SIDE OF PLANS. | | | PLEASE SEE 13-103.1.1.1 | | | PLEASE ALSO SEE THE OWNER AGENT IS NOT SIGNED ON | | | CERTIFICATION SHEET. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | 2007-07-23 13:32:09 | PLANS REMOVED FROM INCOMING, WILL RETURN TO INCOMING | | | WAITING FOR COMM BOARD ONCE ELECTRICAL REVIEW IS | | | COMPLETED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-19 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-19 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2007-06-19 15:06:17 | *** UNSAT 3RD REVIEW *** | | | | | | 1) NOTE: PLEASE SEE THE ENERGY CALCULATIONS ARE NOW | | | SUBMITTED WITHOUT THE INPUT DATA REPORTS SHEETS WHICH | | | ARE REQUIRED. PLEASE SEE STATEMENT ON COVER SHEET EVEN | | | MENTIONS THIS. | | | FBC 113-415.1.C. | | | | | | 2) NOTE: PLEASE SEE THE FA NOTE NOW MENTIONS THE CODE | | | SECTION HOWEVER IT DOES INDICATE THE MINIMUM LEVELS AS | | | NEEDED. MAY NOT QUOTE THE CODE IN LIEU OF THE SPECIFIC | | | REQUIREMENT. | | | FBC 11-4.28.1,.2, AND .3(4). | | | | | | 3) NOTE: PLEASE SEE PLANS NOW INDICATE A NEW 6-POLE | | | CONTACTOR AND LIGHTING CONTROLS HOWEVER NO DETAILS FOR | | | THIS IS SHOWN ON PLANS. NO TIME FOR SCHEDULING, NO | | | TIMES FOR OVER RIDE DEVICES, NO TIMES ON DEVICES WHERE | | | COMPLIANCE WITH FBC CHAPTER 13 IS BEING NOTED. | | | PLEASE CLARIFY AND PROVIDE MORE INFORMATION. | | | | | | 4) NOTE: PLEASE SEE THE PREVIOUS TITLE BLOCKS CONTAINED | | | PRINTED NAME AND PRINTED LICENSE NUMBER OF THE ENGINEER | | | HOWEVER IT WAS IN THE *PRINTED SEAL* WHICH WAS PLACED | | | ON PLANS IN LIEU OF THE RAISED SEAL. NOW PLANS ARE | | | COMING BACK WITHOUT THE PRINTED SEAL AND ONLY THE | | | PRINTED NAME IS SHOWN. PLEASE BE SURE THE PRINTED | | | LICENSE NUMBER IS ON PLANS. FAC 61G15-23.002 | | | PLEASE ALSO CLARIFY WHY THE EXPIRATION DATE FROM FEB 07 | | | IS BEING SHOWN ON TITLE BLOCKS UNDER ENGINEERS SEAL. AS | | | THE EXPIRATION DATE HAS SINCE PAST THIS WOULD NOT BE | | | VALID. THIS LICENSE HAS BEEN VERIFIED WITH THE STATE AS | | | NOT EXPIRED ON THIS DATE AS NOTED. | | | | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-06 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-04 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2007-03-06 07:28:47 | *** UNSAT 2ND REVIEW *** | | | | | | | | | 1) NOTE: PLEASE INCLUDE THE FOLLOWING CODES ALSO | | | RELEVANT TO DESIGN. | | | NFPA-70 2002, 2002 NFPA-72. | | | RESPONSE MENTIONS THAT THE CODES WERE ADDED HOWEVER | | | COULD NOT LOCATE THESE ON THE REVISED SHEETS. PLEASE | | | SEE THAT THE ELECTRICAL SHEETS ALSO SHOULD STATE THESE | | | CODES. | | | . | | | | | | 2) NOTE: PLEASE SEE MISSING LICENSE INFORMATION | | | REQUIRED ON TITLE BLOCKS FOR THE "P" SHEETS. PLEASE SEE | | | THAT A CERTIFICATE OF AUTHORIZATION NUMBER WAS ADDED TO | | | THE ELECTRICAL SHEETS HOWEVER THE NUMBER WHICH WAS | | | ADDED TO THE PLUMBING SHEETS IS IN FACT THE FLORIDA | | | CORPORATION NUMBER WHICH IS NOT THE SAME AS THE CA | | | NUMBER. PLEASE CHECK WITH THE DEPARTMENT OF BUSINESS | | | AND PROFESSIONAL REGULATION AS THEY WILL BE ABLE TO | | | HELP THROUGH THE PROCESS IN OBTAINING A FIRM LICENSE | | | NUMBER. IF THE COMPANY HAS A CA NUMBER, PLEASE ADD TO | | | TITLE BLOCKS. PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.002 AND FLORIDA STATUTES 471.023. | | | THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWER(S). | | | | | | 3) NOTE: PLEASE SEE ELECTRICAL SHEETS HAVE NOW COME | | | BACK WITHOUT A RAISED SEAL AS REQUIRED IN THE STATE OF | | | FLORIDA. FS 471.025, FAC 61G15-23.001 | | | A PRINT OF THE SEAL IS OK AS LONG AS THE RAISED SEAL IS | | | ALSO PRESENT, CLEAR AND VISIBLE WITH ALL INFORMATION ON | | | SAID SEAL. | | | | | | 4) NOTE: PLEASE SEE THE FA DEVICES SEE TO BE CROSSED. | | | PLEASE SEE THE *A* WHICH IS BEING ASSUMED FOR THE | | | AUDIBLE DEVICE INDICATES THE VISUAL LEVELS AS 95CD AND | | | THE *V* FOR VISUAL DEVICE INDICATES 95 DB ? PLEASE | | | VERIFY BOTH OF THESE. THE PREVIOUS COMMENT REFERENCED | | | THE FBC AS NOTED AND LEVELS FOR VISUAL DEVICES WERE | | | 75CD MINIMUM. PLEASE CLARIFY | | | PLEASE SEE FBC 11-4.28.1, .2 AND .3(4). PLEASE | | | INDICATE THE MINIMUM AREAS WILL FALL INTO THESE | | | EXCEPTIONS. | | | | | | | | | AUDIBLE LEVELS AND LIGHTING LEVELS PER FBC. | | | | | | 5) NOTE: PLEASE KNOW THAT ANY *NEW* LIGHTING AREAS AND | | | CONTROLS NOT FOR OPERATION 24HRS A DAY WILL REQUIRE | | | AUTOMATED SHUT OFF FOR LIGHTING PER 13-415.1.ABC.1.1, | | | .1.2 AND .1.3. | | | THIS IS FOR AREAS OF ALL NEW INSTALLATION ONLY AND NOT | | | 24/7 OPERATIONS. | | | THIS IS BEING NOTED ONLY, HOWEVER PLEASE RESPOND IN | | | LETTER IF ANY OF THESE | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-03-06 07:00:31 | 2007-03-06 07:00:31 | | | IN PROGRESS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-05 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-03 |
Time |
20:56 |
Sent To |
|
|
| Notes |
| 2006-11-05 11:22:48 | **** UNSAT **** | | | | | | 1) NOTE: PLEASE INCLUDE THE FOLLOWING CODES ALSO | | | RELEVANT TO DESIGN. | | | 2003 NFPA-101 AND POSSIBLE NFPA-72 2002, 2002 NFPA-72. | | | PLEASE SEE NOTES ON PLANS INDICATE A NFPA-92? BOCA, | | | IBCC, ETC. | | | PLEASE SEE THE SCOPE OF WORK FOR THIS LOCATION IS UNDER | | | THE 2004 FBC. | | | PLEASE ALSO SEE COVER SHEET REFERENCESBY THE CITY FOR | | | 2001, PLEASE KNOW, THIS WOULD BE ACTUALLY THE 2004. | | | PLEASE BE SURE TO ADJUST ALL NOTES ON ALL SHEETS. | | | | | | 2) NOTE: PLEASE SEE MISSING LICENSE INFORMATION | | | REQUIRED ON TITLE BLOCKS FOR BOTH THE "P" AND "E" | | | SHEETS. PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.002 AND FLORIDA STATUTES 471.023.. | | | THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWER(S). | | | | | | 3) NOTE: PLEASE INDICATE THE NEW FA DEVICES OR EXISTING | | | IN AREAS BEING REMODELED. PLEASE SEE FBC 11-4.28.1, .2 | | | AND .3(4). PLEASE INDICATE THE MINIMUM AUDIBLE LEVELS | | | AND LIGHTING LEVELS PER FBC. | | | | | | 4) NOTE: PLEASE SEE METHOD "C" AS INDICATED MENTIONS | | | TOTAL SQ FT AND WHAT APPEARS TO BE TRADES -OFF-S. | | | PLEASE SEE 13-415.2.ABC.1, WHICH MENTIONS TABLES | | | 415.2.C.1 AS TRADE OFFS FOR SPACES ARE NOT PERMITTED. | | | PLEASE CLARIFY THIS. | | | | | | 5) NOTE: PLEASE SEE NO PANEL SCHEDULES WERE SUBMITTED | | | FOR ALL CIRCUITING AS SHOWN ON PLANS.NO REVIEW FOR | | | CODE COMPLIANCE OF OVER CURRENT PROTECTION DEVICES, | | | CONDUCTOR SIZES ETC CAN BE VERIFIED AT THIS TIME. | | | 240.4, 310.16, 408.4. | | | FBC ADMIN SECTION, 106.1.2, 106.3.5.1.2 | | | | | | 6) NOTE: PLEASE SEE SOME RECEPTS IN BATH AREAS WHICH | | | SHOULD BE GFI PROTECTED WHICH DO NOT INDICATE THIS ON | | | PLANS. PLEASE KNOW THERE ARE MANY WHICH SHOW GFI | | | RECEPT, HOWEVER AS SOME OF THESE REFLECT BACK TO PANEL | | | SCHEDULES IT MAY BE POSSIBLE THAT THE GFI PROTECTION IS | | | ACTUALLY IN THE PANEL AT THE BREAKER. HOWEVER PLEASE | | | KNOW AS THE PANEL SCHEDULE(S) HAVE NOT BEEN SUBMITTED | | | THIS CAN NOT BE VERIFIED AT THIS TIME. | | | 210.8B1 | | | | | | | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT THE ELECTRICAL PLANS AS SUBMITTED. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-11-05 09:51:20 | REVIEW IN PROGRESS | | 2006-11-03 20:56:59 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-29 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-29 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2007-08-29 14:34:04 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A6.1, E1.1, AND E2.1 WERE STAMPED, | | | INITIALED, AND DATED. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-29 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-28 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2007-08-29 14:32:37 | *****PROVISO***** | | | | | | THE APPROPIATE PLAN SHEET(S) WILL BE STAMPED WHEN ALL | | | OTHER PLAN REVIEWS HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-22 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-22 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2007-03-22 13:22:57 | *****PROVISO***** | | | | | | THE APPROPIATE PLAN SHEET(S) WILL BE STAMPED WHEN ALL | | | OTHER PLAN REVIEWS HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-29 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-29 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-29 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2006-12-29 14:26:54 | *****DENIED***** | | | | | | | | | | | | 1. NFPA 101 (2003 EDITION) AND THE FLORIDA FIRE | | | PREVENTION CODE (2004) EDITION) SHALL BE REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | | NOT INTERFERE OR HINDER EMERGENCY RESPONSE ACCESS TO | | | THE SAID PROPERTY OR VICINITY THEREOF (INCLUDING FIRE | | | LANES). | | | | | | 4.PLEASE INDICATE IF THE BUILDING OR PORTIONS OF THE | | | BUILDING WILL BE OCCUPIED DURING THE PROPOSED SCOPE OF | | | WORK.IF SO,THIS WILL BE PERMITTED ONLY WHERE | | | REQUIRED MEANS OF EGRESS AND REQUIRED FIRE PROTECTION | | | FEATURES ARE IN PLACE AND MAINTAINED, OR WHERE | | | ALTERNATIVE LIFE SAFETY MEASURES ACCEPTABLE TO THE AHJ | | | ARE IN PLACE. | | | | | | 5.INTERIOR WALL AND CEILING FINISH MATERIALS SHALL | | | BE CLASS A OR CLASS B IN ALL CORRIDORS AND LOBBIES, | | | CLASS A OR CLASS B IN GENERAL ASSEMBLY AREAS HAVING AN | | | OCCUPANT LOAD OF MORE THAN 300, AND SHALL BE CLASS A, | | | CLASS B, OR CLASS C IN ASSEMBLY AREAS HAVING AN | | | OCCUPANT LOADS OF 300 OR FEWER. | | | | | | 6.SEE BUILDING PLAN REVIEW COMMENT #5 IN REFERENCE | | | TO HANDRAILS FOR THE RAMP.PROVIDE THE PRESCIPTIVE | | | STRENGHT FOR THE HANDRAILS. | | | | | | 7.ALL FIRE DOORS SHALL COMPLY WITH NFPA 80. | | | | | | 8.ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN | | | AREA HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS | | | SHALL BE PROVIDE WITH PANIC HARDWARE OR FIRE EXIT | | | HARWARE, UNLESS OTHERWISE THEY ARE DELAYED-EGRESS LOCKS | | | OR ACCESS-CONTROLLED EGRESS LOCKS PERMITTED AND | | | APPROVED BY THE AHJ. | | | | | | 9.PLEASE INDICATE LOCATION OF FIRE EXTINGUISHERS, | | | EXIT LIGHT, EMERGENCY LIGHTS, FIRE PROTECTION SYSTEM | | | DEVICES, ETC.HOW WILL THEY BE AFFECTED BY THE SCOPE | | | OF WORK? | | | | | | 10.IF THE FIRE ALARM AND/OR FIRE SPRINKLER SYSTEM | | | IS/ARE MODIFIED DUE TO THE SCOPE OF WORK, SEPARATE | | | PLANS AND PERMIT WILL BE REQUIRED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RE-SUBMITTING, | | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | | ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-30 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-30 |
Time |
14:31 |
Sent To |
E |
|
| Notes |
| 2007-08-30 14:31:41 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-11 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-11 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2007-07-24 10:06:02 | TO "COMM" BD#54 | | 2007-07-11 09:38:30 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-21 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-21 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2007-06-12 11:41:03 | TO "COMM" BD#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-15 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-15 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2007-02-26 13:20:40 | TO "COMM" BD#39 | | 2007-02-15 15:19:48 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-03 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-28 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2006-11-01 15:18:14 | TO "COMM" BD#43 | | 2006-10-28 14:38:56 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-06 |
Time |
13:58 |
Rev Time |
30.00 |
| Received By |
tgordon |
Date |
2006-11-06 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2006-11-06 13:59:04 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-27 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-27 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-20 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-20 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2007-06-20 10:14:12 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ******FROM PREVIOUS REVIEWS: | | | | | | FROM THE PREVIOUS REVIEW: | | | | | | 1. OK | | | | | | 2. SUBMIT A DETAIL FOR ACCESSIBLE SHOWERS. SHOW | | | COMPLIANCE WITH SECTION 11-4.21 AND ALL SUBSECTIONS. | | | ****RESPONSE NOTED, BUT THE SHOWER UNIT IS STILL | | | REQUIRED AND SHALL BE INDICATED. SECTION 11-4.21.6. | | | ******NO RESPONSE/NOT ADDRESSED. | | | | | | 3. OK | | | 4. OK | | | | | | 5. PLUMBING SHEETS REQUIRE THE PRINTED NAME OF THE | | | PERSON SIGNING AND SEALING THE PLANS. ALSO THE | | | CERTIFICATE OF AUTHORIZATION FOR THE ENGINEERING | | | COMPANY IS REQUIRED. FAC 61G15-23.002(2) AND FS | | | 471.025. | | | ****RESPONSE NOTED, BUT THE PRINTED NAME OF THE PERSON | | | SIGNING & SEALING THE PLANS IS NOT SHOWN, NOR IS THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. THE NUMBER | | | INDICATED IN THE TITLE BLOCK IS NOT FOR WCW ENGINEERS | | | INC. (PLEASE SEE ATTACHED SHEET FROM THE STATE OF | | | FLORIDA DBPR WEBSITE). | | | ******RESPONSE NOTED BY CERTIFICATE OF AUTHORIZATION | | | NUMBER, BUT THE PRINTED NAME OF THE PERSON SEALING THE | | | DOCUMENT IS NOT INDICATED. | | | | | | 6. OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-03-12 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-03-12 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2007-03-12 16:58:59 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM THE PREVIOUS REVIEW: | | | | | | 1. OK | | | | | | 2. SUBMIT A DETAIL FOR ACCESSIBLE SHOWERS. SHOW | | | COMPLIANCE WITH SECTION 11-4.21 AND ALL SUBSECTIONS. | | | ****RESPONSE NOTED, BUT THE SHOWER UNIT IS STILL | | | REQUIRED AND SHALL BE INDICATED. SECTION 11-4.21.6. | | | | | | 3. OK | | | 4. OK | | | | | | 5. PLUMBING SHEETS REQUIRE THE PRINTED NAME OF THE | | | PERSON SIGNING AND SEALING THE PLANS. ALSO THE | | | CERTIFICATE OF AUTHORIZATION FOR THE ENGINEERING | | | COMPANY IS REQUIRED. FAC 61G15-23.002(2) AND FS | | | 471.025. | | | ****RESPONSE NOTED, BUT THE PRINTED NAME OF THE PERSON | | | SIGNING & SEALING THE PLANS IS NOT SHOWN, NOR IS THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. THE NUMBER | | | INDICATED IN THE TITLE BLOCK IS NOT FOR WCW ENGINEERS | | | INC. (PLEASE SEE ATTACHED SHEET FROM THE STATE OF | | | FLORIDA DBPR WEBSITE). | | | | | | 6. OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-03 |
Time |
06:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-02 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2007-01-03 06:48:58 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT D1.1 IN THE REMOVAL OF ANY PART OF THE DRAINAGE | | | SYSTEM, DEAD ENDS ARE PROHIBITED. SECTION 704.5. ALL | | | DEMO'D/ CAPPED PIPING SHALL REMAIN UNCOVERED UNTILL | | | INSPECTED. | | | | | | 2. SUBMIT A DETAIL FOR ACCESSIBLE SHOWERS. SHOW | | | COMPLIANCE WITH SECTION 11-4.21 AND ALL SUBSECTIONS. | | | | | | 3. SHT D1.1 MORE INFORMATION IS REQUIRED. IT IS NOT | | | CLEAR WHAT WAS DELETED IN THE MEN'S LOCKER ROOM FROM | | | NORTH OF COL. LINE #4 TO SOUTH OF COL. LINE #5, AND | | | BETWEEN THE CORRIDOR BETWEEN COL. LINES D & E TO THE | | | WALL BETWEEN THE LOCKER ROOM & THE POOL ROOM. IN THE | | | WOMEN'S LOCKER ROOM THERE IS AN AREA JUST NORTH OF COL. | | | LINE 6 TO THE WALL JUST NORTH OF THE DRINKING FOUNTAIN | | | THAT NEEDS CLARIFICATION AS TO WHAT WAS BEING DEMO'D. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 4. SHT D1.1 THE WOMEN'S ROOM SHOWS 6 SHOWERS IN ONE | | | AREA & 4 SHOWERS IN WOMEN'S SHOWER (036). DEMO | | | INDICATES MAYBE 8 SHOWERS WERE IN AREA 036. WERE | | | SHOWERS DELETED?THIS IS NOT INDICATED IN THE DEMO | | | NOTES. ARE THE ACCESSIBLE SHOWERS IN THE WOMEN'S AND | | | MEN'S ROOMS NEW OR EXISTING? IF NEW SEE COMMENT #2. | | | | | | 5. PLUMBING SHEETS REQUIRE THE PRINTED NAME OF THE | | | PERSON SIGNING AND SEALING THE PLANS. ALSO THE | | | CERTIFICATE OF AUTHORIZATION FOR THE ENGINEERING | | | COMPANY IS REQUIRED. FAC 61G15-23.002(2) AND FS | | | 471.025. | | | | | | 6. PER SECTION 11-4.1.7(2) UP TO 20% OF THE CONTRACT | | | SHALL BE USED TO UPGRADE ACCESSIBILITY REQUIREMENTS. | | | PLEASE INDICATE HOW THIS REQUIREMENT IS BEING COMPLIED | | | WITH. - ACCESSIBLE STALLS DOORS SHALL SWING OUTWARD. IF | | | REPLACING PARTITIONS, THIS REQUIREMENT SHOULD BE | | | BROUGHT UP TO CODE. SEE FIG. 11-30. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|