| Plan Review Stops For Permit 06101014 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-12-19 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-12-19 |
Time |
06:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-11 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
MJACOBS |
Date |
2007-09-14 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2007-09-11 10:50:53 | REVISIONS DOORS AND WINDOWS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-08-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-20 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-18 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2007-08-20 11:49:22 | BUILDING PLAN REVIEW | | | PERMIT: 06101014 | | | ADD: 505 16TH STREET | | | CONT: J.JAY ROTHE | | | TEL: (561) 389-4137 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: REVISION | | | ACTION:P | | | | | | NOTE: | | | IF ANY STRUCTURAL WORK WAS DONE AT THIS PROJECT | | | INDICATE THE AREAS WITH CLOUDS AND GIVE THE DETAIL | | | DRAWINGS WITH DIMENSIONS ACCORDINGLY. THE NEW SPRINKLER | | | SYSTEM WILL INCREASE THE VALUE OF THE PROJECT; | | | THEREFORE ADDITIONAL FEES WILL BE ADDED ACCORDINGLY. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-16 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-16 |
Time |
13:14 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-14 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-14 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-02-15 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-02-15 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2007-02-15 14:20:23 | BUILDING PLAN REVIEW | | | PERMIT:06101014 | | | ADD: 50516TH STREET | | | CONT:J JAY ROTHE INC. | | | TEL: (561)389-4137 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 3RD | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)PROVIDE THE INFORMATION FROM FYRE-TEC. FOR THE FIRE | | | RATED WINDOWS INSTALLATION. | | | | | | 3)THE NEW STRUCTURE FOR E.W.H.NEEDS PRODUCT | | | APPROVALS FOR THE ROOFING SHINGLES. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-11-27 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-11-27 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2006-11-27 10:49:22 | | | | BUILDING PLAN REVIEW | | | PERMIT:06101014 | | | ADD:505 :16THST. | | | CONT: CARLO MERCURIO INC. | | | TEL: (561)630-7591 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) 106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. SUBMIT THE PROCUCT APPROVALS | | | FOR THE FIRE RATED WINDOWS PER NOTE #23 ON SHEET A-1. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-08 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-08 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-12 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-12 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2007-08-12 10:56:34 | | | | | | | ** REVISION DENIED ** | | | | | | | | | 1) NOTE: PLEASE SEE HOLD WHICH WAS PLACED ON PROJECT BY | | | THE INSPECTION SERVICES MANAGER FOR LEVEL OF ALTERATION | | | AND PERMITS WHICH HAVE NOT BEEN APPLIED FOR. | | | | | | 2) NOTE: PLEASE SEE THERE WERE ITEMS REDLINED ON | | | PREVIOUS PLANS WHICH HAVE NOT BEEN ADDED TO PLANS. | | | A) PLEASE SEE MISSING CODE REFERENCES: | | | 2002 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | FBC 2004. | | | | | | B) PLEASE SEE MISSING CIRCUITS TO BE INDICATED ON PANEL | | | SCHEDULE FOR ARC FAULT PROTECTION.210.12,408.4 | | | | | | C) PLEASE SEE MISSING RECEPTACLES IN KITCHEN WITH | | | GREATER THAN 2FT OF WALL SPACE. THIS WAS ADDED TO TWO | | | UNITS AS THIS WAS A NOTE IN THE REVIEW DATED | | | 02/15/07. | | | 210.52 | | | | | | 3) NOTE: PLEASE CLEARLY INDICATE THE REVISIONS ON PLANS | | | WITH CLOUDS/TRIANGLES ETC. | | | PLEASE REVISE PLANS AND TITLE BLOCKS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION. IF THERE AREA ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-07 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-07 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2007-03-07 07:28:14 | REDLINED | | | | | | CODES | | | 2002 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | THE CIRCUITS TO BE LISTED ON PANEL SCHEDULE WAS NOT | | | DONE, REDLINED 2002 210.12 ON PANEL SCHEDULES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-15 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-14 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2007-02-15 07:24:49 | | | | | | | | | | **** UNSAT **** | | | | | | 1) NOTE:PLEASE SEE THE CIRCUITING FOR THE SMOKE | | | ALARMS IS SHOWING ALL THE DEVICES ON SEPARATE CIRCUITS. | | | PLEASE SEE SOME APT UNITS ARE SHOWING AS MANY AS FOUR | | | CIRCUITS FOR THE SMOKE ALARMS. PLEASE KNOW THAT THESE | | | DEVICES ARE REQUIRED TO BE WIRED *INLINE* THEREFORE | | | PLACING 220V ON THESE DEVICES AS THEY ARE ON SEVERAL | | | CIRCUITS FOR ONE UNIT. | | | PLEASE ADJUST ALL CIRCUITING FOR THESE AS THEY SHOULD | | | BE ON ONE CIRCUIT. | | | NFPA-72 11.5.1.1, 11.8.3 | | | | | | 2) NOTE: PLEASE SEE THE LOAD CALCULATIONS AS SHOWN FOR | | | THE UNIT PANELS ARE NOT RESIDENTIAL LOAD CALCULATIONS. | | | PLEASE SEE THE SECTIONS ALSO REFLECTED ON THE PANELS | | | ARE FOR OTHER THAN DWELLING UNITS. | | | PLEASE SEE NEC 220 PART II OR PART III. | | | | | | 3) NOTE: PLEASE SEE THE PREVIOUS NOTES MENTIONED THE | | | MISSING WASHER/LAUNDRY CIRCUIT. PLEASE SEE THIS IS NOW | | | SHOWN ON PANEL SCHEDULE; HOWEVER THE MINIMUM LOAD ON | | | THIS CIRCUIT IS REQUIRED TO BE 1500VA PER 220.16B. | | | PLEASE ALSO SEE THAT THE LOAD CALCULATIONS DO NOT | | | INDICATE OR SHOW THE WASHER/LAUNDRY LOAD BEING | | | FIGURED. | | | 210.11C2 | | | | | | 4) NOTE: PLEASE SEE A COUPLE OF MISSING RECEPTACLES PER | | | 210.52 FOR WALL SPACE TWO FEET OR MORE. PLEASE SEE | | | KITCHEN WALLS IN UNITS *C* AND *D*. THERE ARE REDLINED | | | ON ONE SET OF THE PLANS SUBMITTED. | | | PLEASE ALSO SEE UNIT *B* WHICH DOE SHOW A RECEPTACLE ON | | | THIS TWO FT OF WALL; HOWEVER IT IS BEING SHOWN AS A | | | DEDICATED CIRCUIT FOR THE WALL AC UNIT. PLEASE KNOW AN | | | ADDITIONAL RECEPT WILL BE REQUIRED. | | | PLEASE ALSO SEE THAT THESE RECEPTACLES WHICH ARE | | | MISSING ARE REQUIRED TO BE ON ONE OR MORE OF THE SMALL | | | APPLIANCE CIRCUITS. (210.52B1) | | | | | | 5) NOTE: PLEASE SEE 110.26 FOR THE MINIMUM REQUIRED | | | CLEARANCES FOR THE CU DISCONNECTS. | | | PLEASE SEE THAT THESE ARE BEING SHOWN WITH LESS THAN | | | THE 30 INCHES MINIMUM SIDE TO SIDE REQUIRED. PLEASE SEE | | | SOME WITH LESS THAN 1FT BASED ON THE 3/8 INCHES SCALE | | | AS NOTED ON PLANS. | | | PLEASE ADJUST LAYOUT OF ALL EQUIPMENT AS SHOWN DOWN THE | | | SIDE FOR THESE UNITS. | | | | | | 6) NOTE: PLEASE LIST AND INDICATE THE ARC FAULT | | | PROTECTED BREAKERS ON PANEL SCHEDULE. A NOTE WAS | | | LOCATED ON THE APARTMENT LAYOUT PLANS; HOWEVER PLEASE | | | LIST THE BREAKERS ON PANEL SCHEDULE. | | | 210.12 | | | FBC 106.1.2, 106.3.5.4 ADMIN SECTION. | | | | | | 7) NOTE: PLEASE SEE THE RISER DIAGRAM INDICATES | | | GROUNDING ELECTRODE PER NEC WHOEVER PLEASE INDICATE THE | | | MINIMUM REQUIRED.PLEASE SHOW A MINIMUM OF TOW GROUND | | | RODS AND COLD WATER PIPE (IF METAL). | | | 250.50, 250.56 | | | CODE MAY NOT BE QUOTED IN LIEU OF SPECIFIC OR TECHNICAL | | | DETAIL. | | | | | | 8) NOTE: PLEASE SHOW THE LOCATION AND THE SERVICE ON | | | PLANS. (METERS AND RISER)VERIFICATION FOR 110.26 ETC | | | NEEDS TO BE VERIFIED. ALSO OVER HEAD CLEARANCES FROM | | | 2ND FLOOR WINDOWS SHOULD BE TAKEN INTO CONSIDERATION | | | BASED ON SERVICE RISER LOCATION. (3FT MINIMUM | | | REQUIRED). | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-01 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-31 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2006-11-01 09:40:43 | *******UNSAT ********* | | | | | | | | | ** PLEASE SEE THIS IS A NEW REVIEW UNDER A NEW PERMIT, | | | HOWEVER THIS WAS REVIEWEDUNDER 05111120. PLEASE SEE | | | SOME COMMENTS FROM THE FIRST TWO REVIEWS STILL ARE | | | NOTED. | | | | | | 1) NOTE:PLEASE BE SURE THE RELEVANT CODES ARE | | | REQUIRED TO BE STATED ON PLANS AS FOLLOWS: | | | 2002 NFPA-70, 2002 NFPA-72, 2003 NFPA-101. | | | PLEASE ALSO SEE COMMENT WITH RESPECT THE FHA. | | | | | | 2) NOTE: PLEASE SHOW AND COMPLETE ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED PANEL | | | SCHEDULES. | | | PLEASE SEE "SD", HOWEVER SEE OTHER NOTE FOR THESE. | | | PLEASE ALSO SEE NOTE ABOUT WASHER ETC. | | | FBC 106.1.2 ADMIN SECT. | | | | | | 3) NOTE: PLEASE SEE NFPA DEFINITIONS FOR SMOKE | | | DETECTORS AND SMOKE ALARMS. PLEASE KNOW IF THESE ARE | | | INDEED DEVICES WHICH DETECT AND CONTAIN THE AUDIBLE | | | ALARM, THESE SHOULD BE NOTED AS SA. PLEASE KNOW A SD | | | DEVICE IS A DETECTION DEVICE ONLY AND WOULD SIGNAL AND | | | ALARM PANEL OR HORNS OF SOME TYPE. | | | PLEASE KNOW THIS WAS RECENTLY GONE OVER WITH NFPA AND | | | THE CODE COUNSEL. | | | | | | 4) NOTE: PLEASE INDICATE ALL CONDUCTORS FROM METER BANK | | | TO THE MAIN DISCONNECTS. | | | 310.16, 240.4 | | | | | | 5) NOTE: PLEASE SEE AN "EQUIPMENT GROUNDING CONDUCTOR" | | | IS BEING SHOWN IN THE RISER BEFORE THE FIRST MEANS OF | | | DISCONNECT? | | | PLEASE SEE 250.6, AND 250.24B. | | | | | | 6) NOTE: PLEASE SEE RISER SEEMS TO INDICATE BUILDING | | | STEEL AS PART OF THE GROUNDING ELECTRODE SYSTEM, | | | HOWEVER PLEASE VERIFY THIS AS THIS IS AN EXISTING | | | BUILDING AND IF SHOWN, THEN THIS WOULD BE REQUIRED. | | | 250.50. | | | FBC 106.1.2 | | | | | | 7) NOTE: PLEASE SEE 210.52 FOR SOME MISSING RECEPTS | | | FOR 2FT OR MORE OF WALL , WITHIN 6FT OF DOOR, AND 12 FT | | | OR MORE OF WALL SPACE. | | | | | | 8) NOTE: PLEASE SEE FHAR 24 CFR 100.205 FOR FIRST FLOOR | | | DEVICES TO BE SHOWN AND NOTED. | | | | | | 9) NOTE: PLEASE SEE UNIT "A" WHICH SHOWS A KITCHEN GFI | | | RECEPT ON THE KITCHEN LIGHTING CIRCUIT WHICH IS NOT | | | PERMITTED. PLEASE SEE 210.52B1. | | | | | | 10) NOTE: PLEASE SEE NO CIRCUIT OR RECEPT DEVICE SHOWN | | | FOR UNIT "A" WASHER. | | | 210.11C2, | | | FBC 106.1.2 | | | | | | 11) NOTE: PLEASE SEE 210.52B1, WHICH REQUIRES RECEPTS | | | LOCATED ON DINING/KITCHEN/ BREAKFAST AREAS AND THE LIKE | | | SHALL BE ON ONE OR MORE OF THE SMALL APPLIANCE | | | CIRCUITS. PLEASE SEE SOME AREAS WHICH FIT INTO THIS | | | DESCRIPTION OR DESIGNATION HOWEVER THEY ARE ON GENERAL | | | LIGHTING CIRCUITS WHICH IS NOT PERMITTED. | | | | | | 12) NOTE: PLEASE PROVIDE THE MIN LIGHTING LEVELS FOR | | | STAIRS UNDER NORMAL POWER FOR MIN EGRESS REQUIREMENTS | | | PER NFPA-101 7.8.1.3, AND MIN LEVELS UNDER | | | EMERGENCY.7.9.2.2 | | | A BATTERY BACK UP FIXTURE OF SOME SORT WILL BE REQUIRED | | | FOR EMERGENCY EGRESS TO THE PUBLIC RIGHT OF WAY. | | | PLEASE ALSO CLARIFY HOW THIS LIGHTING FROM THE HOUSE | | | PANEL IS BEING CONTROLLED?? | | | | | | 13) NOTE: PLEASE SUBMIT SPEC FOR OUTSIDE WATER HEATER | | | UNITS FROM THE MANUFACTURE INDICATING LISTINGS FROM | | | NRTL. | | | 110.3, 90.7 | | | FBC 106.1.2 | | | | | | 14) NOTE: PLEASE CORRELATE MECHANICAL PLANS WITH | | | ELECTRICAL FOR SIZING OF THE HEAT IN THE AHU'S. PLEASE | | | SEE THESE ARE BEING SHOWN AS 10KW, HOWEVER PLEASE SEE | | | MECH PLANS INDICATE 5KW? | | | FBC 106.1.2, NEC 424.3B, 310.16 | | | ** PLEASE SEE A NAX OCP DEVICE IS ALSO USUALLY SET BY | | | THE MANUFACTURE HOWEVER TYPICALLY 150%. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT THE ELECTRICAL PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2006-10-31 17:56:43 | REMOVED FROM INCOMING, IN ELEC FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-08-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-20 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-20 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2007-08-20 14:23:24 | *****APPROVED***** | | | REVISED PLAN SHEETS A-2 AND E-1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-15 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-15 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2007-03-15 17:03:17 | *****APPROVED***** | | | | | | | | | ALL COMMENTS FROM PREVIOUS FIRE PLAN REVIEWS HAVE BEEN | | | SATISFIED.PLAN SHEETS A-2 AND E-1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-23 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-23 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2007-02-23 12:10:38 | *****UNSAT***** | | | | | | | | | THE FOLLOWING COMMENTS WHICH WERE TAKEN FROM THE | | | PREVIOUS FIRE PLAN REVIEW OF 11/21/2006 STILL NEED TO | | | BE RECTIFIED. | | | | | | | | | 1.THE SITE PLAN ON SHEET A-2 DEPICTS QUINCE STREET AS | | | THE NORTH-SOUTH ROADWAY.THIS ROADWAY IS SPRUCE | | | AVENUE. | | | | | | 2.ON SHEET A-1, GENERAL NOTE #27, REFERENCE SHOULD BE | | | MADE TO NFPA 241 NOTNFPA 421. | | | | | | 3.ON SHEET A-1, GENERAL NOTE #32, DELETE THE WORD | | | "WILL" AND INSERT THE WORDS "SHALL NOT" BETWEEN | | | PROCEDURES --- HINDER. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-21 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-11-21 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2006-11-21 12:08:36 | *****DENIED***** | | | | | | | | | | | | 01.PLEASE PROVIDE A LAYOUT OF THE STRUCTURE ON A SITE | | | PLAN AS TO HOW IT RELATES TO THE NEAREST STREETS, | | | HYDRANTS, RAILROAD, ETC. | | | | | | 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | | NOT HINDER OR INTERFERE WITH EMERGENCY ACCESS TO THE | | | SAID PROPERTY OR VICINITY THEREOF. | | | | | | 04.FIRE EXTINGUISHERS TO BE RATED 2A-10 BC. | | | | | | 05.PLEASE BE ADVISED THAT SMOKE DETECTORS (SD) ARE | | | TIED INTO A FIRE ALARM SYSTEM.THE DEVICES USED AT THE | | | SITE ARE SMOKE ALARMS (SA) AND SHOULD BE REFLECTED AS | | | SUCH IN THE SUBMITTED PLANS. | | | | | | 06.FOR SPECIFIC LOCATION REQUIREMENTS OF SMOKE | | | ALARMS/SMOKE DETECTORS, NFPA 72 - 2002 EDITION - | | | 11.8.3.5 SHALL BE REFERENCED. | | | | | | 07.SMOKE ALARMS INSTALLED WITHIN 20-FT HORIZONTAL | | | PATH OF A COOKING APPLIANCE SHALL BE EQUIPPED WITH AN | | | ALARM SILENCING MEANS OR BE OF THE PHOTOELECTRIC TYPE. | | | | | | 08.SMOKE ALARMS SHALL RECEIVE ITS OPERATING POWER | | | FROM THE BUILDING'S ELECTRICAL SERVICE. | | | | | | 09.INSTALL A SMOKE ALARM IN THE LIVING AREA OF THE | | | UNITS. | | | | | | 10. INTERIOR FINISH FOR WALLS AND CEILING SHALL BE | | | CLASS "A" OR CLASS "C".PLEASE SPECIFY. | | | | | | 11. VERITY THAT THE NUMERICAL ADDRESS (ON THE BUILDING) | | | IS NO LESS THAN 6" IN HEIGHT AND 1" IN WIDTH PLAINLY | | | VISIBLE FROM 16TH STREET.EACH UNIT SHALL HAVE A | | | NUMBER OR ALPHABET NO LESS THAN 3" IN HEIGHT ABOVE OR | | | IN THE VICINITY OF THE FRONT DOOR (NOT ON THE DOOR). | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-12 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-12 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2007-12-12 14:40:32 | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-27 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-27 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2007-09-08 15:13:44 | TO BOB SPACE #2 | | 2007-08-27 16:03:30 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-10 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-10 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2007-08-10 08:43:47 | TO BOB BOARD #11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-02 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-02 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2007-08-02 10:42:23 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-11 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-11 |
Time |
10:25 |
Sent To |
M |
|
| Notes |
| 2007-07-11 10:27:47 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-06 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-06 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2007-03-06 15:30:45 | TO "BOB"#5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-14 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-14 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2007-02-14 10:10:36 | TO "BOB"#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-11-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-28 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2006-11-02 09:42:38 | TO "BOB"#18 | | 2006-10-28 16:13:55 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-13 |
Time |
11:11 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-08-13 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2007-08-13 11:12:58 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-12 |
Time |
09:49 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-12 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2007-07-12 09:53:58 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) RETURN AIR DUCT (FLEX) TO AHU-D NEEDS TO BE SIZED. | | | | | | 2) A/C EQUIPMENT SCHEDULE IS MISSING FROM REVISED PLAN, | | | PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-11-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-02 |
Time |
12:03 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-02 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-21 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-21 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2007-08-21 15:23:55 | REVISION: | | | NOTE: THERE ARE NO CHANGES ONPLUMBING SHEET P-1 FROM | | | THE ORIGINAL, JUST AN UPDATED SIGNATURE, SEAL AND DATE | | | BY ENGINEER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-10 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-10 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-22 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-22 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2007-02-22 10:06:17 | DENIED; | | | STUDIO SHOWER MUST BE A MINIMUM OF 900 SQ. INCH. | | | MINIMUM OF 30" IN DIMENTION MESSURED FROM INSIDE FINISH | | | INTERIOR DIMENTION. FBC-2004 SECTION 417.4. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-17 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-17 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2006-11-17 12:37:53 | DENIED; | | | 1. PLEASE ADD NOTE TO PLUMBING PAGE. "A REDUCED | | | PRESSURE PRINCIPAL BACKFLOW PREVENTOR TO BE INSTALLED | | | ON THE BUILDING SIDE OF THE | | | WATER METER" | | | 2. PLEASE SHOW BATHROOM MEASUREMENTS IN BATHROOMS WHERE | | | THE LAVATORYS WERE MOVED. A DISTANCE OF 30" IS REQUIRED | | | FROM THE CENTERLINE | | | OF TOILET TO THE CENTERLINE OF THE LAVATORY, AND | | | 15" TO THE EDGE OF THE TUB TO THE CENTERLINE OF THE | | | TOILET. FBC-2004 PLUMBING SECTION | | | 405.3.1 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2007-09-14 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2007-09-14 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-17 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2007-08-17 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2007-08-17 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2007-08-17 11:05:03 | PLEASE PROVIDE A SURVEY WITH SETBACK INFORMATION. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435 | | | WITH QUESTIONS. |
|
|