Plan Review Details - Permit 06101011
Plan Review Stops For Permit 06101011
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-06-20 Cont ID  
Sent By mjacobs Date 2007-06-20 Time 12:12 Rev Time 0.00
Received By mjacobs Date 2007-06-20 Time 10:51 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-05-22 Cont ID  
Sent By mjacobs Date 2007-05-22 Time 08:13 Rev Time 0.00
Received By mjacobs Date 2007-05-22 Time 05:52 Sent To PC
Notes
2007-05-22 08:13:56BUILDING PLAN REVIEW
 PERMIT:06101011
 ADD:3202AUSTRALIAN CT.
 CONT: OWNERS
 TEL: (561)863-5754
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE ACTUAL PERMIT PLANS
 MUST BE STAMPED BY THAT OFFICE, AND A
 COPY OF THE PAID RECEIPT ATTACHED TO
 THE PERMIT APPLICATION.PLEASE CALL
 (561) 233-5025 FOR MORE INFORMATION.
  
 3)THE CLAIMED VALUATION IS TO LOW. FOR PERMITTING
 PURPOSES, VALUATION SHALL BE THE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, ARCHITECTURAL AND VALUE.
 OUR VALUATION REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER 103.8 FBC*
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-06 Cont ID  
Sent By mjacobs Date 2007-01-06 Time 10:11 Rev Time 0.00
Received By mjacobs Date 2007-01-05 Time 16:25 Sent To PC
Notes
2007-01-05 18:56:01BUILDING PLAN REVIEW
 PERMIT:06101011
 ADD: 3202 AUSTRALIAN CT.
 CONT: OWNER
 TEL: (561)863-5754
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST.
 ACTION: DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2) 106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.MANY OF THE PRODUCT APPROVAL
 SUBMITTED ARE FROM THE 2001 CODE REFERENCE. THESE
 PRODUCTS NEED TO REFERENCE THE 2004 CODE AND THE
 APPLICATION STATUS HAS TO BE APPROVED. CHECK THE
 PROCUCT APPROVALS CARREFULLY BECAUSE THERE ARE A FEW
 WHICH ARE STILL PENDING FBC APPROVAL. THE PROCUCT
 APPROVALS SHALL BE APPROVED IN "WRITING" NOT BY
 STAMPING. SUBMIT UPDATED AND APPROVED PRODUCT APPROVALS
 WHICH SHALL BE APPROVED IN WRITING BY THE DESIGNER OF
 RECORD.
  
 3)THE CLAIMED VALUATION IS TO LOW. FOR PERMITTING
 PURPOSES,VALUATION SHALL BE THE TOTAL REPLACEMENT VALUE
 TO INCLUDE STRUCTURAL,ELECTRIC, PLUMBING,
 MECHANICAL,INTERIOR FINISH,ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, EXCLUDING LAND VALUE.OUR
 VALUATION REFERENCE IS ICC (BVD), MARSHALL-SWIFT AND
 MEANS COST ANALYSIS SERVICES PER 103.8 FBC*
  
 4) 110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
 ) SQ. FT. UNDER ROOF (TOTAL)
 ) OCCUPANT LOAD
 ) FLOOD ZONE
 ) FLOOD ELEVATION
 )L.O.M.R.
  
 5)R302.2 OPENINGS.
 OPENINGS SHALL NOT BE PERMITTED IN THE EXTERIOR WALL OF
 A DWELLING OR ACCESSORY BUILDING THAT IS SEPARATED FROM
 AN ADJACENT BUILDING BY A DISTANCE OF LESS THAN 6 FEET
 (1828 MM). THIS DISTANCE SHALL BE MEASURED
 PERPENDICULAR TO THE LINE USED TO DETERMINE THE
 SEPARATION DISTANCE. SHOW THE DISTANCE FROM THE
 PROPERTY LINE FOR THE NEW ADDITION WHICH WILL HAVE NEW
 OPENINGS. SUBMIT THIS INFORMATION ON A SITE PLAN.
  
 6)R802.1.6.1 TRUSS DESIGN DRAWINGS.
 TRUSS DESIGN DRAWINGS, PREPARED IN CONFORMANCE WITH
 SECTION R802.10.1 , SHALL BE PROVIDED TO THE BUILDING
 OFFICIAL AND APPROVED PRIOR TO INSTALLATION. TRUSS
 DESIGN DRAWINGS SHALL INCLUDE, AT A MINIMUM, THE
 INFORMATION SPECIFIED BELOW. TRUSS DESIGN DRAWING SHALL
 BE PROVIDED WITH THE SHIPMENT OF TRUSSES DELIVERED TO
 THE JOBSITE.
  
 7)R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048
 MM).
  
 8)WHAT IS THE THICKNESS OF THE ROOF SHEATING?
 INDICATE ON THE DRAWINGSTHE NUMBER OF SCREEN VENT TO BE
 INSTALLED AND WILL MEET THE REQUIREMENTS OF SECTION
 R806.2.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-05-04 Cont ID  
Sent By btrobaug Date 2007-05-04 Time 07:20 Rev Time 0.50
Received By btrobaug Date 2007-05-04 Time 06:43 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-11-16 Cont ID  
Sent By btrobaug Date 2006-11-16 Time 14:52 Rev Time 0.50
Received By btrobaug Date 2006-11-16 Time 13:14 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-06-12 Cont ID  
Sent By adarroug Date 2007-06-12 Time 10:29 Rev Time 0.00
Received By adarroug Date 2007-06-12 Time 10:29 Sent To M
Notes
2007-06-12 10:29:42TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-01 Cont ID  
Sent By adarroug Date 2007-05-01 Time 09:45 Rev Time 0.00
Received By adarroug Date 2007-05-01 Time 09:45 Sent To E
Notes
2007-05-01 09:45:44TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-04-27 Cont ID  
Sent By adarroug Date 2007-04-27 Time 11:09 Rev Time 0.00
Received By adarroug Date 2007-04-27 Time 11:09 Sent To Z
Notes
2007-04-27 11:10:01TO "Z" BOX/RESUB--NEW SHEETS FOR "P" AND "E"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-08 Cont ID  
Sent By adarroug Date 2006-11-08 Time 13:28 Rev Time 0.00
Received By adarroug Date 2006-11-08 Time 13:28 Sent To E
Notes
2006-11-08 13:29:08TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-01-06 Time   Rev Time 0.00
Received By adarroug Date 2006-10-28 Time 15:10 Sent To  
Notes
2006-10-28 15:10:27TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-06-13 Cont ID  
Sent By tgordon Date 2007-06-13 Time 15:58 Rev Time 0.30
Received By tgordon Date 2007-06-13 Time 15:58 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-05-11 Cont ID  
Sent By tgordon Date 2007-05-11 Time 13:30 Rev Time 0.30
Received By tgordon Date 2007-05-11 Time 13:30 Sent To B
Notes
2007-05-11 13:54:54*** DENIED ***
 1) ENERGY CALCULATIONS NEED THE SIGNATURES OF THE
 PREPARER AND OWNER/AGENT NOT JUST PRINTED NAMES, SEE
 2004 FBC 13-103.1.1 AND 13-600.3.A.
  
 2) NEED TO SUBMIT TWO COPY'S OF THE ENERGY CAL'S.
  
 3) PLEASE SUBMITCOOLING LOAD CALCULATIONS, PER 2004
 FBC 13-607.1.ABC.1 .
  
 4) SEE MECHANICAL PLANS 'A/C NOTES' REFERENCES PALM
 BEACH COUNTY, NEEDS TO SHOW CITY OF WEST PALM BEACH,
 PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-11-21 Cont ID  
Sent By tgordon Date 2006-11-21 Time 09:48 Rev Time 0.30
Received By tgordon Date 2006-11-21 Time 09:48 Sent To B
Notes
2006-11-21 10:00:15*** DENIED ***
 1) MANUAL J CALCULATIONS ARE FOR THE TOTAL HOUSE 1802
 SQUARE FEET, THE A/C SYSTEM IS ONLY SERVING THE
 ADDITION 777 SQUARE FEET, PLEASE RE-DO MANUAL J
 CALCULATION,CORRECT ENERGY CALCULATIONS, AND
 EQUIPMENT LISTING ON MECHANICAL PLANS AS A RESULT.
  
 2) SHOW SIZE OF RETURN AIR GRILL AT AHU.
  
 3) SEE NOTES ON MECHANICAL PLAN REFER TO THE CITY OF
 BOYTON BEACH, PLEASE CORRECT TO CITY OF WPB.
  
 4) RETURN AIR TRANSFER DUCT TO MASTER BEDROOM SUITE
 NEEDS TO BE 14", SEE NOTE #5 (A) AND (C) EXCEPT.
  
 5) BALANCED RETURN AIR.
 MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-05-11 Cont ID  
Sent By mperson Date 2007-05-11 Time 11:02 Rev Time 0.33
Received By mperson Date 2007-05-11 Time 11:02 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-11-20 Cont ID  
Sent By jleech Date 2006-11-20 Time 08:28 Rev Time 0.00
Received By jleech Date 2006-11-20 Time 08:28 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-04-30 Cont ID  
Sent By choops Date 2007-04-30 Time 16:23 Rev Time 0.00
Received By choops Date 2007-04-30 Time 16:23 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-11-07 Cont ID  
Sent By mmclean Date 2006-11-07 Time 16:03 Rev Time 0.00
Received By mmclean Date 2006-11-07 Time 16:03 Sent To I
Notes
2006-11-07 16:05:07DENIED,
 1. PLEASE SHOW THE PROPOSED A/C UNIT ON THE TWO COPIES
 OF SURVEYS WITH SETBACKS.
 2. SURVEYS SUBMITTED DOES NOT SHOW THE A/C UNIT.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy