| Plan Review Stops For Permit 06100844 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-07 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2007-01-07 |
Time |
20:07 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2007-01-07 |
Time |
19:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-01 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-01 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2006-11-01 08:39:58 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY | | | SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | | THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT | | | COMMENCED WITHIN 90 DAYS OF RECORDING. | | | | | | 2.HAND DRAWN CHANGES TO PLANS NOT PERMITTED.FBC | | | 106.1.3 WPB AMMENDMENTS. | | | | | | 3.BASED ON ICC BUILDING VALUATION DATA THE PERMIT | | | VALUE HAS BEEN REVISED TO $167,128.00.ADDITIONAL | | | PERMIT FEES ARE DUE. | | | | | | 4.SEPERATE ROOFING PERMIT REQUIRED. | | | | | | 5.PRODUCT APPROVALS REQUIRED FOR LINTELS. | | | | | | 6.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER | | | 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE | | | APPROVED PRIOR TO INSTALLATION. | | | | | | 7.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | | OF 6 INCHESWITHIN THE FIRST 10 FEET. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6672 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-04 |
Time |
06:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-06-04 |
Time |
06:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-05-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-25 |
Time |
13:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-05-25 |
Time |
10:20 |
Sent To |
PC |
|
| Notes |
| 2007-05-25 14:02:55 | | | | | | | REVISION DENIED/INCOMPLETE INFORMATION. | | | | | | 1} PLEASE CORRECT THE PANEL SCHEDULE. THE REQUIRED BATH | | | CIRCUITS HAVE BEEN REMOVED, THERE IS NO DISHWASHER, | | | DISPOSAL OR LIGHTING CIRCUITS SHOWN. SEE PERMITTED | | | PLANS, USE THE SAME FORMAT. | | | | | | 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | | PROTECTED PER 210.8(A) (1). SEE MASTER BATH NEEDS ADDED | | | RECEPTACLE. | | | | | | 3} THE DEMAND CALCULATION FOR THEAHU @100%=3150 AND | | | HTR@65%, IS INCORRECT. THE HEAT LOAD IS IN THE AHU, AND | | | 8000 WATTS IS NOT 65% OF ANY COMMON SYSTEM ON THE | | | MARKRT. THE PERMITTED SET OF MECHANICAL PLANS INDICATE | | | A 8000 WATT AHU. SEE NOTE #7 OF THE PREVIOUS REVIEW. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-16 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-16 |
Time |
11:02 |
Sent To |
PC |
|
| Notes |
| 2007-05-16 15:12:55 | ** UNSAT** | | | | | | ** PLEASE SEE REFERENCES TO CHAPTER 1 OF THE FLORIDA | | | BUILDING CODE IS THE ADMINISTRATIVE SECTION AS ADOPTED | | | BY THE CITY OF WEST PALM BEACH. | | | | | | | | | ** PLEASE SEE THE ELECTRICAL PLANS AND RISER DIAGRAM | | | HAS BEEN REVISED FROM PREVIOUS REVIEWED PLANS WHICH | | | HAVE CREATED NEW COMMENTS. | | | | | | 1) NOTE: PLEASE SEE PLANS ARE NOT INDICATING ANY | | | REVISIONS BY CLOUDS/TRIANGLES OR DATES IN TITLE BLOCK. | | | FBC 106.1.2 | | | | | | 2) NOTE: PLEASE SEE MISSING AIC RATING FOR NEW MAIN. | | | 110.9 | | | FBC 106.3.5.4 | | | | | | 3) NOTE: PLEASE SEE THE RISER DIAGRAM IS NOW REVISED | | | SHOWING NEW MAIN, YET PLANS STILL INDICATE NO MAIN | | | DISCONNECT OUTSIDE? | | | PLEASE ALSO SEE THE SERVICE WAS REVISED ON THE PREVIOUS | | | PLANS AND RISER TO INDICATE A 200A SERVICE HOWEVER THE | | | PANEL SCHEDULE NOW SHOWS PANEL AT 150AMPS?? | | | PLEASE REVISE TO SHOW LOCATION OF ALL SERVICE EQUIPMENT | | | ON PLANS. | | | 110.26, FBC 106.1.2 | | | | | | 4) NOTE: PLEASE SEE 250.6, 250.24 AS THE RISER IS | | | MISSING THE EQUIPMENT GROUNDING CONDUCTOR FROM MAIN TO | | | THE PANEL. | | | * EQUIPMENT GROUNDS ARE INSTALLED AFTER THE FIRST MEANS | | | OF DISCONNECT* | | | | | | 5) NOTE: PLEASE SEE PLANS ARE MISSING THE RECEPTACLE | | | OUTLET FOR DISHWASHER. ONLY THE COUNTER SPACE | | | RECEPTACLE REQUIRED PER 210.52C IS SHOWN. | | | FBC 106.1.2 | | | | | | 6) NOTE: PLEASE SEE THE GFI WHICH IS BEING SHOWN | | | DIRECTLY BEHIND THE SINK WHICH IS NOT PERMITTED. THIS | | | WAS REDLINED ON PREVIOUS PLANS; HOWEVER IT IS STILL | | | BEING SHOWN AT THE SAME LOCATION. | | | 210.52C | | | FBC 106.1.2 | | | | | | 7) NOTE: PLEASE SEE THE ELECTRICAL PLANS DO NOT | | | CORRELATE THE LOADS ON PANEL SCHEDULE WITH THAT OF THE | | | LOAD ON LOAD CALCULATIONS FOR THE AHU/A/C SYSTEM. | | | PLEASE SEE THE MECHANICAL PLANS ON FILE ALSO DO NOT | | | COORDINATE WITH EITHER OF THESE TWO AS SHOWN. | | | PLEASE COORDINATE AND REVISED. | | | PLEASE SEE 220, 424. | | | FBC106.1.2 | | | | | | 8) NOTE: PLEASE SEE MISSING RECEPTACLE FOR WALL SPACE | | | IN BREAKFAST/KITCHEN/DINING AREA. | | | 250.10 | | | | | | 9) NOTE: PLEASE SEE THE PANEL SCHEDULE SHOWS A NEW | | | MICROWAVE CIRCUIT IN THE SPACE OF A SPARE AND PLANS DO | | | NOT INDICATE CONDUCTORS, OCP, OR LOADS. | | | PLEASE REVISED ALL AND CORRELATE. | | | FBC 106.1.2 | | | 310.16, 240.4, 408.4 | | | | | | 10) NOTE: PLEASE SEE PLANS DO CONTAIN A NOTE FOR WATER | | | HEATER TO BE HARDWIRED HOWEVER THE PLANS STILL INDICATE | | | A RECEPTACLE FOR THIS. | | | PLEASE SEE 422.31, 422.30 | | | | | | 11) NOTE: PLEASE SEE PANEL SCHEDULE MUST BE REVISED FOR | | | ALL CIRCUITS TO BE SPECIFIC TO ALL ROOMS AND AREAS IN | | | WHICH THEY FEED. THE USE OF *GENERAL LIGHTS* IS NOT | | | PERMITTED PER 408.4. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-04-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-07 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-07 |
Time |
15:20 |
Sent To |
PC |
|
| Notes |
| 2007-04-07 15:31:10 | REDLINED PLANS* | | | WATER HEATER TO BE HARDWRIED, DISCONNECT MAY BE IN | | | PANEL.422.30 | | | GFI AT SINK TO BE RELOCATED PER 210.52C1, NOT TO BE | | | BEHIND SINK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-12-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-03 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-03 |
Time |
19:01 |
Sent To |
P |
|
| Notes |
| 2006-12-03 19:21:01 | **** REDLINED PLANS***** | | | | | | PLANS INDICATE A 200A PANEL LOCATED ON GARAGE, HOWEVER | | | RISER AND PANEL SCHEDULE SHOWS PANEL AS 150A W/ 150A | | | MCB. | | | | | | | | | | | | | | | | | | ***** ONLY NOTED, THE TRUSS PLANS CONTAIN A | | | "RUBBERSTAMP" FOR THE REQUIRED ORIGINAL SIGNATURE. SEE | | | BUILDING REVIEW COMMENTS FOR THIS , ALONG WITH FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 AND FLORIDA STATUTES | | | 471.025 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-25 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-25 |
Time |
11:13 |
Sent To |
Z |
|
| Notes |
| 2006-10-25 11:32:17 | **** UNSAT ***** | | | | | | *** PLEASE KNOW, ONCE AN ADDRESS IS GRANTED AND GIVEN, | | | THIS NEW ADDRESS SHALL BE STATED IN THE TITLE BLOCKS OF | | | SAID PLANS. | | | FAC 61G1-16.004 | | | | | | 1) NOTE: PLEASE STATE THE FOLLOWING RELEVANT CODES ON | | | PLANS. 2002 NFPA-70(NEC), 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SUBMIT ALL AIC RATINGS FOR NEW SERVICE | | | EQUIPMENT. 110.9, 240.12 | | | | | | 3) NOTE; PLEASE SEE NFPA-72 DEFINITIONS AS IT HAS BEEN | | | COMMON ACCEPTANCE THAT THE SMOKE ALARMS ARE SHOWN | | | TYPICALLY AS SD'S WHICH IS ACTUALLY CONSIDERED SMOKE | | | DEETCTORS WHICH ONLY DETECT SMOKE AND ARE PART OF A | | | FIRE ALARM SYSTEM. PLEASE KNOW AS THE IS A SFR AND IT | | | DOES NOT REQUIRE A FA SYSTEM,. PLEASE INDICATE THESE AS | | | "SA"'S SMOKE ALARMS AS THESE ARE DEVICES THAT DETECT | | | AND PROVIDE AN AUDIBLE SIGNAL AS REQUIRED. PLEASE SEE | | | THIS HAS BEEN CONFIRMED WITH AN INTERPRETATION FROM | | | NFPA- ON A RECENT CODE PANEL MEETING. | | | | | | 4) NOTE: PLEASE SEE MISSING EGRESS LITHING CONTROL AND | | | LT FIXTURE OF SOME SORT AT REAR OF DWELLING. 210.70, | | | AND NFPA-101 7.8. | | | | | | 5) NOTE: PLEASE INDICATE THE REQUIRED DEDICATED BATH(S) | | | CIRCUIT(S) PER 210.52D, 210.11C3. DOES NOT INDICATE | | | BATH ON PANEL SCHEDULE. PLEASE KNOW THAT THE PANEL | | | SCHEDULE SHALL BE SPECIFIC IN ORDER TO REVIEW FOR CODE | | | COMPLIANCE., | | | 408.4.310.16,240.4 TEC. | | | | | | 6) NOTE: PLEASE SHOW LOAD CALCULATIONS PER NEC 220.31, | | | METHOD CHOSEN IS UP TO DESIGNER, HOWEVER PLEASE SEE MIN | | | VA/WATTS PER SQ FT ETC SHALL BE SHOWN. | | | | | | ** A A NOTE TO DESIGN PROFESSIONALS , PLEASE SEE FS | | | 481.229(1) FS 471.025 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-01 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-01 |
Time |
15:20 |
Sent To |
E |
|
| Notes |
| 2007-06-01 15:21:27 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-22 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-22 |
Time |
10:13 |
Sent To |
E |
|
| Notes |
| 2007-05-22 10:13:27 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-14 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-14 |
Time |
16:35 |
Sent To |
E |
|
| Notes |
| 2007-05-14 16:36:02 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-05 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-05 |
Time |
17:06 |
Sent To |
P |
|
| Notes |
| 2007-04-05 17:06:31 | TO JOHN LEECH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-05 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-05 |
Time |
17:05 |
Sent To |
E |
|
| Notes |
| 2007-04-05 17:06:01 | TO DEWEY PALMER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-11-29 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
17:11 |
Sent To |
E |
|
| Notes |
| 2006-11-29 17:12:36 | SENT TO DEWEY PALMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-20 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-20 |
Time |
11:45 |
Sent To |
Z |
|
| Notes |
| 2006-11-20 11:45:41 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-01 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-25 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2006-10-25 09:04:14 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-26 |
Time |
16:35 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-10-26 |
Time |
16:35 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-18 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-18 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2007-04-18 14:21:00 | REVISED PLUMBING DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-09 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-09 |
Time |
13:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-10-26 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-30 |
Time |
07:04 |
Sent To |
B |
|
| Notes |
| 2006-10-30 07:11:10 | DENIED; | | | 1. SANITARY RISER DIAGRAM DOES NOT MATCH FLOOR PLAN. | | | ONLY 2 BATHROOMS ON FLOOR PLAN. | | | 2. THE FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES WASHER IS | | | 2"THE BRANCH DRAIN SHALL BE 3" | | | AND A CLEANOUT SHALL BE INSTALLED AT 48" AFF. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-11-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-25 |
Time |
21:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-25 |
Time |
21:50 |
Sent To |
I |
|
| Notes |
| 2006-11-26 21:52:34 | PROVISO: THE PROPOSED PAVER DRIVEWAY CAN ONLY BE SAND | | | BASE IN ORDER TO MEET THE ZONING REQUIREMENTS FOR | | | LANDSCAPE WITHIN THE FIRST 25FT FRONT SETBACK. | | | DRIVEWAY NOT TO BE SEALED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-10-26 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-10-26 |
Time |
13:17 |
Sent To |
P |
|
| Notes |
| 2006-10-26 13:43:08 | DENIED, | | | 1. THE PROPOSED A/C UNIT MUST BE SHOWN ON TWO COPIES OF | | | SURVEYS. | | | 2. PLEASE PROVIDE THE DIMENSION OF THE PROPOSED | | | DRIVEWAY & WALKWAY (LENGTH & WIDTH). CAN ONLY HAVE | | | 312.62SQ FT OF CONCRETE WITHIN THE FIRST 25FT FRONT | | | SETBACK. | | | | | | MUST MAINTAIN 1000SQ FT OR 75% OF | | | LANDSCAPE, WHICHEVER IS LESS WITHIN THE | | | FIRST 25FT FRONT SETBACK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|