Plan Review Details - Permit 06100782
Plan Review Stops For Permit 06100782
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-04 Cont ID  
Sent By shill Date 2007-01-04 Time 14:34 Rev Time 0.00
Received By shill Date 2007-01-04 Time 13:12 Sent To PC
Notes
2007-01-04 14:35:14****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB
 FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
  
 1.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO
 PERMIT PICKUP, FS713.13.
  
 2.)IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY
 PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD.THE PLANS
 MUST BE STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.PLEASE CALL 561-233-5025 FOR MORE
 INFORMATION.
  
 3.)INCLUDE FBC EB IN GOVERNING CODE.DECLARE LEVEL
 OF ALTERATION, FBC EB CHAPTER 3.
  
 4.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER
 OF RECORD, FBC*106.3.3.
  
 5.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED
 IN ADDITION TO THE NOAS SUBMITTED, FAC9B72.
 WWW.FLORIDABUILDING.ORG.
  
 6.)PRODUCT APPROVALS REQUIRED FOR THE EXTERIOR DOOR
 (CABANA BATH) AND THE FIXED GLASS WINDOW.
  
 7.)SHOW ATTIC ACCESS LOCATION FBC R807.1.
  
 8.)SHOW VENTILATION IN COMPLIANCE WITH FBC R806.
  
 9.)SMOKE DETECTORS REQUIRED FBC R313.1.
  
 10.)SHOW DIMENSIONS FROM GRADE TO BOTTOM OF FOOTING
 AND TOP OF SLAB.
  
 11.)SHOW DRAINAGE FBC R401.3.
  
 12.)A7, FOUNDATION NOTE 3, REFERS TO THE INCORRECT
 ACI REFERENCE, FBC 35.
  
 13.)A7, WOOD TRUSSES, NOTE REFERS TO INCORRECT
 ANSI/TPI REFERENCE, FBC35.
  
 14.)SHOW EMERGENCY EGRESS FOR PROPOSED NEW BEDROOMS,
 FBC R310.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-11-08 Cont ID  
Sent By btrobaug Date 2006-11-08 Time 10:39 Rev Time 1.00
Received By btrobaug Date 2006-11-08 Time 06:34 Sent To P
Notes
2006-11-08 10:37:44 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.2.
  
 2} SUBMIT PANEL SCHEDULES PER 408.4 NEC AND
 106.3.5.4(8) FBC. ALL PANELS SO CALCULATIONS CAN BE
 REVIEWED, AND BRANCH CIRCUIT AND OVERCURRENT PROTECTION
 REQUIREMENT MAY BE REVIEWED FOR COMPLIANCE.
  
 3}PROVIDE LOAD CALCULATIONS PER 220 SECTION I,
 STANDARD CALCULATION,IF DERATING THE NEUTRAL, OR
 220.SECTION III, OPTIONAL CALCULATIONS. IT WOULD APPEAR
 THE LOAD AFTER DEMAND IS GREATER THAN THE SERVICE
 PROVIDED.
  
 4} GFI,S ARE REQUIRED FOR BATH RECEPTACLES PER
 210.8(A)(1), 2002 NEC. INDICATE ON PLANS.
  
 5} BATHROOM RECEPTACLES (AT LEAST ONE) MUST BE WITHIN
 3' OF THE BASIN PER 210.52, SEE MASTER BATH.
  
 6} THE MASTER AND GUEST BEDROOM NEED ADDED RECEPTACLES
 TO COMPLY WITH 210.52(A)(1) &( 2), SEE REVIEWED SET FOR
 EXAMPLE.
  
 7} THE HALLWAY MUST HAVE ONE RECEPTACLE TO COMPLY WITH
 210.52(H).
  
 8} SMOKE DETECTORS MUST BE INSTALLED TO COMPLY WITH
 R313.1 RESIDENTIAL FLORIDA BUILDING CODE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-07 Cont ID  
Sent By adarroug Date 2006-11-07 Time 14:59 Rev Time 0.00
Received By adarroug Date 2006-11-07 Time 14:58 Sent To E
Notes
2006-11-07 14:59:25TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-04 Cont ID  
Sent By shill Date 2007-01-04 Time 14:35 Rev Time 0.00
Received By shill Date 2006-10-24 Time 17:32 Sent To  
Notes
2006-10-24 17:33:14TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-11-21 Cont ID  
Sent By jleech Date 2006-11-21 Time 08:00 Rev Time 0.30
Received By tgordon Date 2006-11-21 Time 07:59 Sent To B
Notes
2006-11-21 08:11:12*** DENIED ***
 1) NEED SIZE OF RETURN AIR TRUNK LINE TO AHU.
  
 2) PROVIDE COMBUSTION AIR FOR GAS WATER HEATER IN
 CLOSET, PER 2004 FBC/R M1701.1.
  
 3) OPEN GRILL IN COVERED PATIO WILL NEED AN APPROVED
 EXHAUST HOOD, PER 2004 FBC/M 505.3.
  
 4) PLEASE SUBMIT DETAILED MANUFACTURER'S
 SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR
 HOOD.
  
 5) SEECOPRE LINE SIZES ON MECHANICAL PLANS 3/8 AND
 1/8, DO YOU MEAN 1 1/8 ? PLEASE PLEASE CORRECT IN TWO
 PLACES SHOWING COPPER LINE SIZES OR SUBMIT
 MANUFACTURER'S SPECIFICATION'S FOR A/C SYSTEM.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-11-17 Cont ID  
Sent By jleech Date 2006-11-17 Time 15:07 Rev Time 0.00
Received By jleech Date 2006-11-17 Time 15:04 Sent To M
Notes
2006-11-17 15:06:58THE PERSON TAKING RESPONABILITY FOR DRAWINGS IS
 REQUIRED TO PRINT AND SIGN THEIR NAME TO SAID
 DRAWINGS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status F Date 2006-11-03 Cont ID  
Sent By mmclean Date 2006-11-03 Time 18:12 Rev Time 0.00
Received By jleech Date 2006-11-03 Time 18:12 Sent To M
Notes
2006-11-03 18:28:23DENIED,
 1. THE SITEPLANS DOES NOT PROVIDE ANY SETBACKS THAT IS
 MATCHING TO THE EXISTING SURVEY & THE PROPOSED
 ADDITION.
 2. PLEASE NOTE IF THE WOOD DECK HAS AN EXISTING ROOF.
 IF DECK HAS ROOF, THE ADDITION MUST BE 6FT FROM
 STRUCTURE (BUILDING SEPARATION).
 3. THE SITEPLANS SHOW THE LOCATION OF A/C UNIT, BUT THE
 SURVEY DOES NOT, PLEASE MARK ON THE TWO COPY OF
 SURVEYS.
 4. PLEASE USE TWO COPIES OF SURVEYS TO SHOW THE
 PROPOSED WORK WITH SETBACKS (LEGAL DOCUMENT).
 5. A SEPERATE PERMIT IS NEEDED FOR THE GENERATOR AND
 CAN ONLY ENCROACH 4FT INTO REQUIRED SETBACK
 (GENERATOR/SLAB MUST BE 9.44FT FROM THE REAR PROPERTY
 LINE.
 6. PLEASE IDENTIFY THE ROOMS THAT THE PROPOSED ADDITION
 WILL HAVE INTERIOR ACCESS. ADDITION MUST HAVE INTERIOR
 ACCESS FROM THE EXISTING STRUCTURE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720