| Plan Review Stops For Permit 06100743 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-26 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-26 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-09 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-09 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2007-01-09 17:49:16 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) EGRESS DOORS ARE REQUIRED TO SWING IN THE DIRECTION | | | OF EGRESS TRAVEL WHERE SERVING AN OCCUPANT LOAD OF 50 | | | OR MORE PERSONS PER FBC 1008.1.2. ON SHEET A2 THE FIFTH | | | FLOOR PLAN SHOWS AN EGRESS DOOR "A" AT STAIR 1 WHICH | | | DOES NOT SWING IN THE DIRECTION OF EGRESS TRAVEL. | | | PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-08 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-08 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2006-11-14 07:06:02 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE CONSTRUCTION TYPE BASED ON THE 2004 FBC | | | DESIGNATIONS AS SPECIFIED IN FBC TABLE 601. SPECIFY A | | | OR B. | | | | | | 3) THE DOORS TO ONE SET OF EGRESS STAIRS ARE NOT SHOWN | | | ON THE FLOOR PLANS ON SHEETS A2-A7. | | | | | | 4)EGRESS DOORS ARE REQUIRED TO SWING IN THE DIRECTION | | | OF EGRESS TRAVEL WHERE SERVING AN OCCUPANT LOAD OF 50 | | | OR MORE PERSONS PER FBC 1008.1.2. | | | | | | 5) PROVIDE THE FLAME SPREAD AND SMOKE DEVELOPED INDEXES | | | FOR THE WOOD VENEER PANELS IN THE CORRIDORS AT THE | | | ELEVATORS. SEE FBC 803.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-13 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-13 |
Time |
11:39 |
Sent To |
PC |
|
| Notes |
| 2007-08-13 16:38:06 | REV FOR BATH ROOMS/HALLWAYS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-30 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-30 |
Time |
07:01 |
Sent To |
I |
|
| Notes |
| 2007-01-11 13:20:34 | PLANS ROUTED BACK TO ELEC FOR PROCESSING 1/11/07 | | 2006-10-30 07:08:24 | ELEC OK, STAMPED "E" SHEETS, SENT BACK TO INCOMING. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-09 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-09 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2007-01-09 13:45:24 | *****APPROVED***** | | | | | | | | | | | | ALL FIRE PLAN REVIEW COMMENTS OF 11/20/2006 HAVE BEEN | | | ADDRESSED.PLAN SHEETS A-8 AND E-1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-20 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-11-20 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2006-11-20 14:14:14 | *****DENIED***** | | | | | | | | | | | | 1.IN ADDITION TO THE 2003 EDITION OF NFPA 101, | | | FLORIDA FIRE PREVENTION CODE - 2004 EDITION - SHALL BE | | | REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.ACCUMULATIONS OF COMBUSTIBLE WASTE MATERIAL, DUST | | | AND DEBRIS SHALL BE REMOVED FROM THE STRUCTURE AND ITS | | | IMMEDIATE VICINITY AT THE END OF EACH SHIFT OR MORE | | | FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. | | | | | | 4.THE BUILDING'S FIRE PROTEDCTION SYSTEMS SHALL BE | | | MAINTAINED OPERATIONAL AT ALL TIMES. | | | | | | 5.HOW MANY FLOORS WILL BE DONE AT A TIME?IF THE | | | FLOOR(S) IS/ARE BE OCCUPIED DURING THE SCOPE OF WORK, | | | HOW WILL THE REQUIRED MEANS OF EGRESS INCLUDING DOORS, | | | WALKWAYS, STAIRS, ETC BE MAINTAINED TO ENSURE | | | REASONABLE LIFE SAFETY? | | | | | | 6.IF THE FIRE ALARM OR FIRE SPRINKLER SYSTEM ARE TO | | | BE MODIFIEDDUE TO THE SCOPE OF WORK, SEPARATE PLANS | | | AND PERMIT ARE REQUIRED. | | | | | | 7.INDICATE INTERIOR FINISH FOR WALLS AND CEILINGS. | | | CLASS A OR B IS REQUIRED IN THE MEANS OF EGRESS AREAS. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | | ITEM WAS ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-10 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-10 |
Time |
09:19 |
Sent To |
E |
|
| Notes |
| 2007-08-10 09:20:11 | TO DP'S INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-25 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-25 |
Time |
10:28 |
Sent To |
B |
|
| Notes |
| 2007-01-25 10:28:59 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-14 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-14 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2006-12-30 16:11:15 | TO BOB #16 12/30 | | 2006-12-14 16:05:52 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-20 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-24 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2006-11-01 10:16:39 | TO "BOB"#7 | | 2006-10-24 13:56:52 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-01 |
Time |
13:57 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2006-11-01 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-15 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-15 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2006-11-15 07:57:35 | FIXTURE CHANGE ONLY |
|
|