Plan Review Details - Permit 06100725
| Plan Review Stops For Permit 06100725 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-11-13 |
Time |
16:42 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-11-13 |
Time |
16:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-11-01 |
Time |
15:14 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-11-01 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2006-11-01 15:38:36 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE KEY PLAN SHOWING LOCATION OF OPENINGS. | | | DRAWING SUBMITTED IS NOT A KEY PLAN BUT AN ELEVATION OF | | | OPENINGS. ALSO, CLARIFY IF OPENINGS TO BE PROTECTED ARE | | | THE DOORS, THEN HOW ARE THE WINDOWS SHOWN ON ELEVATION | | | BEING PROTECTED. SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | 2- CLARIFY IF USING FLORIDA PRODUCT APPROVAL FL5345 | | | WITH DRAWINGS #05-517 OR DADE COUNTY NOANOA | | | #05-0713.03. BOTH PRODUCT APPROVALS WERE SUBMITTED. | | | NEED TO SUBMIT COMPLETE INFORMATION FOR ONLY ONE | | | PRODUCT APPROVAL. DON'T MISMATCH ONE WITH THE OTHER. IF | | | USING DADE COUNTY NOA, THEN PROVIDE THE MISSING | | | DRAWINGS. | | | | | | 3- INSTALLATION SCHEDULE SUBMITTED: | | | A) ANCHOR SPACING DOESN'T WORK. SEE SHEET5 OF 6 OF | | | DRAWING 05-517 SUBMITTED. | | | B) MIN. EDGE DISTANCE OF 1.25" DOESN'T WORK. SEE | | | SHEET 5 OF 6 OF DRAWING 05-517 SUBMITTED. | | | C) CLEARLY IDENTIFY SPECIFIC ANCHOR TO BE USED. SEE | | | SHEET 5 OF 6 OF DRAWING 05-517 SUBMITTED AND DESCRIBE | | | SPECIFIC ANCHOR.THERE ARE DIFFERENT TYPES OF TAPCONS | | | ANDWHAT IS A LEAD ANCHOR?. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-13 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-13 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2006-11-13 11:28:56 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-11-01 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-10-23 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2006-10-23 11:01:55 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy