| Plan Review Stops For Permit 06100722 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-06-08 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-06-08 |
Time |
11:33 |
Sent To |
PC |
|
| Notes |
| 2007-06-08 11:33:58 | BUILDING REVISION OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-02-07 |
Time |
14:55 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2007-02-07 |
Time |
12:36 |
Sent To |
PC |
|
| Notes |
| 2007-02-07 15:00:03 | BUILDING REVIEW PROVISO: | | | 1- PROVIDE TRUSS DRAWINGS APPROVED BY DESIGNER OF | | | RECORD PRIOR TO INSTALLATION.SEE SEC. R802.1.6 2004 | | | FLORIDA RESIDENTIAL CODE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-01-22 |
Time |
17:52 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2007-01-22 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2007-01-22 17:53:29 | BUILDING REVIEW CHECKLIST: | | | 1-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY | | | AMENDMENTS TOFBC 2004. PRODUCT APPROVALS FOR | | | HORIZONTAL SLIDER, SINGLE HUNG WINDOWS AND CASEMENT | | | WINDOWS WERE NOT REVIEWED AND APPROVED. | | | | | | 2- STORM SHUTTERS: | | | A) ACCORDING TO PRODUCT APPROVALDRAWING #05-279 | | | PAGE 13 OF 21 THE MAXIMUM SHUTTER HEIGHT IS 4'-6".SEE | | | TABLE ON BOTTOM CENTER OF PAGE.THERE ARE SOME | | | OPENINGS THAT EXCEED THIS DIMENSION. THEREFORE, IT | | | CAN'T BE USED ON THOSE OPENINGS. | | | | | | B) MINIMUM EDGE DISTANCE IS 3.5".SEE ENGINEERED | | | DRAWINGS. THERE ARE SOME OPENINGS SHOWING 2.5" EDGE | | | DISTANCE. REVISE AS REQUIRED. | | | | | | C) THERE IS NOT INFORMATION GIVEN FOR PROPOSED | | | INSTALLATION OF STORM PANELS AT FRONT DOOR. ONLY THE | | | PRODUCT APPROVAL WAS SUBMITTED. PROVIDE COMPLETE | | | INFORMATION.SEC. 106.1.2 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | 3- ENERGY CALCULATIONS; | | | A) WHO PREPARED THE CALCULATIONS. THIS SECTION WAS | | | LEFT BLANK. | | | | | | B)ARCHITECT SIGNING AND SEALING AT BOTTOM OF FORM | | | TO PROVIDE ALL HIS INFORMATIONAS REQUIRED BY CHAPTER | | | 481 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS FOR | | | PUBLIC RECORDS. | | | | | | C) PERMIT NUMBER WRITTEN ON TOP OF FORM DOESN'T | | | CORRESPOND TO PERMIT NUMBER FOR THIS ADDITION. REVISE | | | AS REQUIRED. | | | | | | 4- NOTICE OF COMMENCEMENT IS EXPIRED AFTER 90 DAYS OF | | | RECORDING IF WORK IS NOT STARTED. SEE SEC. 713.13 | | | FLORIDA STATUTES. PROVIDE RE-RECORDED NOTICE OF | | | COMMENCEMENT. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-11-09 |
Time |
18:45 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2006-11-09 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2006-11-09 19:01:02 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE SOIL TEST REPORT. | | | | | | 2- PROVIDE FLORIDA PRODUCT APPROVAL AS REQUIRED BY RULE | | | 9B-72 FOR: | | | A) GARAGE DOOR. NEED TO PROVIDE CLEAR AND LEGIBLE | | | DRAWINGS. ONE SUBMITTED IS NOT LEGIBLE. | | | B) FRONT DOOR. | | | C) FRENCH DOORS WITH AND WITHOUT SIDELITES AS SHOWN | | | ON PLANS.DADE COUNTY NOA SUBMITTED IS EXPIRED AND THE | | | FLORIDA PRODUCT APPROVAS ARE MISSING THE DRAWINGS. NEED | | | COMPLETE AND CURRENT PRODUCT APPROVAL PACKAGE. | | | D) ALL SIMPSON CONNECTORS SPECIFIED ON PLANS. | | | E) ROOF SHINGLES.ACCORDING TO DADE COUNTYPRODUCT | | | APPROVAL WEBSITE NOA 02-1209.10 SUBMITTED THE FILE IS | | | CLOSED. NEED TO PROVIDE CURRENT NOA. | | | F) PRECAST LINTELS. NOA 03-0605.04 SUBMITTED IS FOR | | | 4", 6" AND 12" LINTELS. NEED PRODUCT APPROVAL FOR 8" | | | LINTELS AS SPECIFIED ON PLANS. | | | G) STORM SHUTTERS. NEED COMPLETE PRODUCT APPROVAL. | | | H) LAUNDRY EXTERIOR DOOR. | | | | | | 3- DESIGNEROF RECORD TO REVIEW AND APPROVE IN | | | WRITTING ALL PRODUCT APPROVALS AS REQUIRED BY SEC. | | | 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 4- STORM SHUTTERS: | | | A) PROVIDE COMPLETE PRODUCT APPROVAL PACKAGE. | | | B) PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE | | | ATTACHED CITY SAMPLE OF INSTALLATION SCHEDULE AND | | | PROVIDE ALL THE REQUIRED INFORMATION. | | | | | | 5- ENERGY CALCULATIONS: | | | A) CLARIFY WHY THE CONDITIONED FLOOR AREA IN ITEM #5 | | | IS DIFFERENT ON ITEM #10. REVISE AS REQUIRED. | | | | | | B) IF USING CEILING FANS CREDIT, THEN NEED TO | | | SPECIFY FAN SIZES IN ALL ROOMS AS REQUIRED BY TABLE | | | 13-607.1.A.1 OF FBC 2004. | | | | | | C) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | | | | 6- PROVIDE DRAINAGE PLANS INDICATING FLOW OF WATER AS | | | REQUIRED BY SEC. R401.3 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 7- TRUSSES WILL NEED TO BE SUBMITTED FOR REVIEW AS | | | REQUIRED BY SECTION R802.10 2004 FLORIDA RESIDENTIAL | | | CODE. DESIGNER OF RECORD TO REVIEW AND APPROVE THEM | | | BEFORE SUBMITTAL TO THIS OFFICE. | | | | | | 8- DRAWING #1: | | | A) THIS IS NOT "LEVEL 2" ALTERATION. REVISE NOTE AS | | | REQUIRED. SEE CHAPTER 3 OF 2004 EXISTING BUILDING FOR | | | ALTERATION LEVEL DEFINITIONS. | | | | | | B) SPECIFY SAFETYGLASS AT EXISTING BATH WINDOW AND | | | AT MASTER BATH ROMAN TUB AS REQUIRED BY SEC. R308.4 | | | 2004 FLORIDA RESIDENTIAL CODE. | | | | | | C) SPECIFY CALCULATED DESIGN PRESSURES FOR GARAGE | | | DOOR. | | | | | | 9- ROOF PITCH IS 3.375:12. NEED TO SPECIFY DOUBLE | | | DOUBLE LAYER OF UNDERLAYMENT AS REQUIRED BY SEC. | | | R905.2.7 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 10- TYPICAL WALL SECTION. SPECIFY FIREBLOCKING AS | | | REQUIRED BY SEC. R602.8 2004 FLORIDA RESIDENTIAL CODE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (5610805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-06-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-14 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-14 |
Time |
15:57 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-03 |
Time |
07:48 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-01-02 |
Time |
15:41 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-03 |
Time |
10:08 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-11-03 |
Time |
08:41 |
Sent To |
P |
|
| Notes |
| 2006-11-03 10:08:07 | | | | | | | INCOMPLETE INFORMATION | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} INDICATE CONDUIT AND CONDDUCTOR SIZE AND TYPE FOR | | | THE SERVICE RISER. 215.5. | | | | | | 2} PROVIDE A PANEL SCHEDULE PER 408.4. FOR PANEL LISTED | | | AS EMERGENCY. THERE ARE NO BRANCH CIRCUITS SHOWN FOR | | | THIS 20 CIRCUIT PANEL. | | | | | | 3} PLEASE SHOW LOAD CALCULATIONS PER 220.3SECTION I | | | STANDARD METHOD OR OPTIONAL METHOD SECTION III. | | | | | | 4} 210.52(C)(1) WALL COUNTER SPACES. A RECEPTACLE | | | OUTLET SHALL BE INSTALLED AT EACH WALL COUNTER SPACE | | | THAT IS 300 MM (12 IN.) OR WIDER. RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 600 MM (24 IN.) MEASURED HORIZONTALLY FROM | | | A RECEPTACLE OUTLET IN THAT SPACE. | | | | | | 5} 210.8(A) DWELLING UNITS. ALL 125-VOLT, SINGLE-PHASE, | | | 15- AND 20-AMPERE RECEPTACLES INSTALLED IN THE | | | LOCATIONS SPECIFIED IN (1) THROUGH (8) SHALL HAVE | | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | | PERSONNEL. | | | (1) BATHROOMS | | | | | | 6} 210.63 HEATING, AIR-CONDITIONING, AND REFRIGERATION | | | EQUIPMENT OUTLET. | | | A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND | | | WITHIN 7.5 M (25 FT) OF THE HEATING, AIR-CONDITIONING, | | | AND REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET | | | SHALL NOT BE CONNECTED TO THE LOAD SIDE OF THE | | | EQUIPMENT DISCONNECTING. | | | | | | 7} SMOKE DETECTORS MUST BE INSTALLED TO COMPLY WITH | | | R313.1 RESIDENTIAL FLORIDA BUILDING CODE. SEE FRONT | | | BEDROOM. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-05 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-05 |
Time |
14:15 |
Sent To |
P |
|
| Notes |
| 2007-10-05 14:15:53 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-13 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-13 |
Time |
16:34 |
Sent To |
E |
|
| Notes |
| 2007-06-13 16:34:57 | TO "BTROBAUGH" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-05-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-29 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-29 |
Time |
10:13 |
Sent To |
B |
|
| Notes |
| 2007-05-29 10:14:13 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-06 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-06 |
Time |
13:56 |
Sent To |
B |
|
| Notes |
| 2007-02-06 13:56:55 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-12-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-29 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-29 |
Time |
09:47 |
Sent To |
E |
|
| Notes |
| 2006-12-29 09:47:29 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-22 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-22 |
Time |
09:02 |
Sent To |
Z |
|
| Notes |
| 2006-12-22 09:02:26 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-01 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-01 |
Time |
18:50 |
Sent To |
E |
|
| Notes |
| 2006-11-01 18:50:34 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-11-09 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-10-23 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2006-10-23 13:13:38 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-09 |
Time |
10:54 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-01-09 |
Time |
10:54 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-06 |
Time |
09:50 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2006-11-06 |
Time |
09:50 |
Sent To |
B |
|
| Notes |
| 2006-11-06 09:54:05 | *** DENIED *** | | | 1) RETURN AIR TRANSFER DUCTS TO ALL BEDROOMS ARE TO | | | SMALL. | | | BALANCED RETURN AIR. | | | MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-10-17 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-17 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-17 |
Time |
14:04 |
Sent To |
PC |
|
| Notes |
| 2007-10-17 14:06:31 | REVISION: "OK" SHEET 1, CHANGED INTERIOR ELECTRIC WATER | | | HEATER TO AN EXTERIOR GAS TANKLESS WATER HEATER. | | | NOTE: GAS PERMIT HAS BEEN APPLIED FOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-08 |
Time |
16:07 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-01-08 |
Time |
16:07 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-06 |
Time |
08:34 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-11-06 |
Time |
08:33 |
Sent To |
M |
|
| Notes |
| 2006-11-06 09:01:42 | UNSAT | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW ON THE RESUBMITTAL TO MEET CODE | | | COMPLIANCE: | | | | | | 1. IN BATH #2 THE TUB AND SHOWER NEEDS A VENT PER | | | FBC-2004 PLUMBING SECTION 909.1 WET VENTS. | | | | | | 2. IN BATH #2 THE FLOOR DRAIN INDICATED NEEDS A TRAP | | | PRIMER PER FBC-2004 PLUMBING SECTION 1002.4 TRAP SEAL. | | | | | | 3. IN THE KITCHEN THE AIR ADMITTANCE VALVE IS | | | INDICATED IN THE WRONG PLACE PER FBC-2004 PLUMBING | | | SECTION 917.4 LOCATION. PLEASE INDICATE THE DISH WASHER | | | DRAIN ON THE RESUBMITTAL. | | | | | | 4. IN THE MASTER BATH THE SHOWER NEEDS A VENT PER | | | FBC-2004 PLUMBING SECTION 909.1 WET VENTS. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-02-28 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-02-28 |
Time |
15:42 |
Sent To |
PC |
|
| Notes |
| 2008-02-28 15:42:59 | ***APPROVED - LANDSCAPE PLAN SUBMITTAL*** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-27 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-27 |
Time |
17:44 |
Sent To |
I |
|
| Notes |
| 2006-12-27 17:56:31 | NOTE: THE PROPOSED GARAGE MUST NOT BE USED FOR LIVING | | | SPACE. | | | NOTE: SEPARATE PERMIT SHALL BE PULLED FOR | | | POOL/SPA/DECK, SHOWING THE POOL EQUIPMENT ON TWO COPIES | | | OF SURVEYS. | | | NOTE: SEPARATE PERMIT SHALL BE PULLED FOR FENCE WITH | | | EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH | | | UTILITY DEPT AND BELLSOUTH, ADELPHIA/COMCAST, FPL, | | | FLORIDA PUBLIC UTILITIES. | | | NOTE: THE PROPOSED A/C UNIT SHALL NOT BE CLOSER THAN | | | 1FT FROM SIDE PROPERTY LINE. | | | NOTE: THE WIDTH OF PROPOSED DRIVEWAY SHALL BE A MINIMUM | | | OF 8.5FT WIDE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-10-30 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-10-30 |
Time |
16:20 |
Sent To |
I |
|
| Notes |
| 2006-10-30 16:43:25 | DENIED, | | | 1. PLEASE SHOW ALL PROPOSED WORK ON THE TWO COPIES OF | | | SURVEYS. (SURVEY IS THE LEGAL DOC). | | | 2. SITEPLANS SUBMITTED DOES NOT MATCH THE SETBACKS AS | | | INDICATED ON SURVEY. | | | 3. PLEASE MARK ON THE TWO COPIES OF SURVEYS IF THE SHED | | | WILL BE DEMOLISHED. | | | 4. THE PROPOSED DRIVEWAY MUST MEET THE CURRENT CODE OF | | | 8.5FT WIDE (YOU WILL NEED TO MEET THE REQUIREMENT FOR | | | LANDSCAPE WITHIN THE 25FT FRONT SETBACK). | | | 5. PLEASE SHOW THE LOCATION OF THE A/C UNIT ON TWO | | | COPIES OF SURVEYS. | | | 6. MUST PULL A SEPARATE PERMIT FOR FENCE/GATE WITH | | | EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH | | | UTILITY DEPT. IF THE FENCE GATE IS CLOSING ACCESS TO | | | THE 5FT U.E. ALL RELEASES WILL BE NEEDED (BELLSOUTH, | | | ADELPHIA, FPL, FLORIDA PUBLIC UTILITIES, CITY OF WEST | | | PALM BEACH UTILITY DEPT). | | | 7. CANNOT BUILD FENCE ETC INTO THE 5FT U.E. IN THE REAR | | | OF THE PROPERTY. | | | | | | NOTE: THE PROPOSED GARAGE CANNOT BE USED FOR LIVING | | | SPACE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|