Plan Review Details - Permit 06100722
Plan Review Stops For Permit 06100722
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-06-08 Cont ID  
Sent By jgomez Date 2007-06-08 Time 11:33 Rev Time 0.00
Received By jgomez Date 2007-06-08 Time 11:33 Sent To PC
Notes
2007-06-08 11:33:58BUILDING REVISION OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-02-07 Cont ID  
Sent By jgomez Date 2007-02-07 Time 14:55 Rev Time 1.50
Received By jgomez Date 2007-02-07 Time 12:36 Sent To PC
Notes
2007-02-07 15:00:03BUILDING REVIEW PROVISO:
 1- PROVIDE TRUSS DRAWINGS APPROVED BY DESIGNER OF
 RECORD PRIOR TO INSTALLATION.SEE SEC. R802.1.6 2004
 FLORIDA RESIDENTIAL CODE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-01-22 Cont ID  
Sent By jgomez Date 2007-01-22 Time 17:52 Rev Time 2.00
Received By jgomez Date 2007-01-22 Time 12:40 Sent To  
Notes
2007-01-22 17:53:29BUILDING REVIEW CHECKLIST:
 1-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY
 AMENDMENTS TOFBC 2004. PRODUCT APPROVALS FOR
 HORIZONTAL SLIDER, SINGLE HUNG WINDOWS AND CASEMENT
 WINDOWS WERE NOT REVIEWED AND APPROVED.
  
 2- STORM SHUTTERS:
 A) ACCORDING TO PRODUCT APPROVALDRAWING #05-279
 PAGE 13 OF 21 THE MAXIMUM SHUTTER HEIGHT IS 4'-6".SEE
 TABLE ON BOTTOM CENTER OF PAGE.THERE ARE SOME
 OPENINGS THAT EXCEED THIS DIMENSION. THEREFORE, IT
 CAN'T BE USED ON THOSE OPENINGS.
  
 B) MINIMUM EDGE DISTANCE IS 3.5".SEE ENGINEERED
 DRAWINGS. THERE ARE SOME OPENINGS SHOWING 2.5" EDGE
 DISTANCE. REVISE AS REQUIRED.
  
 C) THERE IS NOT INFORMATION GIVEN FOR PROPOSED
 INSTALLATION OF STORM PANELS AT FRONT DOOR. ONLY THE
 PRODUCT APPROVAL WAS SUBMITTED. PROVIDE COMPLETE
 INFORMATION.SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 3- ENERGY CALCULATIONS;
 A) WHO PREPARED THE CALCULATIONS. THIS SECTION WAS
 LEFT BLANK.
  
 B)ARCHITECT SIGNING AND SEALING AT BOTTOM OF FORM
 TO PROVIDE ALL HIS INFORMATIONAS REQUIRED BY CHAPTER
 481 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS FOR
 PUBLIC RECORDS.
  
 C) PERMIT NUMBER WRITTEN ON TOP OF FORM DOESN'T
 CORRESPOND TO PERMIT NUMBER FOR THIS ADDITION. REVISE
 AS REQUIRED.
  
 4- NOTICE OF COMMENCEMENT IS EXPIRED AFTER 90 DAYS OF
 RECORDING IF WORK IS NOT STARTED. SEE SEC. 713.13
 FLORIDA STATUTES. PROVIDE RE-RECORDED NOTICE OF
 COMMENCEMENT.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-11-09 Cont ID  
Sent By jgomez Date 2006-11-09 Time 18:45 Rev Time 2.00
Received By jgomez Date 2006-11-09 Time 07:53 Sent To  
Notes
2006-11-09 19:01:02BUILDING REVIEW CHECKLIST:
 1- PROVIDE SOIL TEST REPORT.
  
 2- PROVIDE FLORIDA PRODUCT APPROVAL AS REQUIRED BY RULE
 9B-72 FOR:
 A) GARAGE DOOR. NEED TO PROVIDE CLEAR AND LEGIBLE
 DRAWINGS. ONE SUBMITTED IS NOT LEGIBLE.
 B) FRONT DOOR.
 C) FRENCH DOORS WITH AND WITHOUT SIDELITES AS SHOWN
 ON PLANS.DADE COUNTY NOA SUBMITTED IS EXPIRED AND THE
 FLORIDA PRODUCT APPROVAS ARE MISSING THE DRAWINGS. NEED
 COMPLETE AND CURRENT PRODUCT APPROVAL PACKAGE.
 D) ALL SIMPSON CONNECTORS SPECIFIED ON PLANS.
 E) ROOF SHINGLES.ACCORDING TO DADE COUNTYPRODUCT
 APPROVAL WEBSITE NOA 02-1209.10 SUBMITTED THE FILE IS
 CLOSED. NEED TO PROVIDE CURRENT NOA.
 F) PRECAST LINTELS. NOA 03-0605.04 SUBMITTED IS FOR
 4", 6" AND 12" LINTELS. NEED PRODUCT APPROVAL FOR 8"
 LINTELS AS SPECIFIED ON PLANS.
 G) STORM SHUTTERS. NEED COMPLETE PRODUCT APPROVAL.
 H) LAUNDRY EXTERIOR DOOR.
  
 3- DESIGNEROF RECORD TO REVIEW AND APPROVE IN
 WRITTING ALL PRODUCT APPROVALS AS REQUIRED BY SEC.
 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 4- STORM SHUTTERS:
 A) PROVIDE COMPLETE PRODUCT APPROVAL PACKAGE.
 B) PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE
 ATTACHED CITY SAMPLE OF INSTALLATION SCHEDULE AND
 PROVIDE ALL THE REQUIRED INFORMATION.
  
 5- ENERGY CALCULATIONS:
 A) CLARIFY WHY THE CONDITIONED FLOOR AREA IN ITEM #5
 IS DIFFERENT ON ITEM #10. REVISE AS REQUIRED.
  
 B) IF USING CEILING FANS CREDIT, THEN NEED TO
 SPECIFY FAN SIZES IN ALL ROOMS AS REQUIRED BY TABLE
 13-607.1.A.1 OF FBC 2004.
  
 C) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 6- PROVIDE DRAINAGE PLANS INDICATING FLOW OF WATER AS
 REQUIRED BY SEC. R401.3 2004 FLORIDA RESIDENTIAL CODE.
  
 7- TRUSSES WILL NEED TO BE SUBMITTED FOR REVIEW AS
 REQUIRED BY SECTION R802.10 2004 FLORIDA RESIDENTIAL
 CODE. DESIGNER OF RECORD TO REVIEW AND APPROVE THEM
 BEFORE SUBMITTAL TO THIS OFFICE.
  
 8- DRAWING #1:
 A) THIS IS NOT "LEVEL 2" ALTERATION. REVISE NOTE AS
 REQUIRED. SEE CHAPTER 3 OF 2004 EXISTING BUILDING FOR
 ALTERATION LEVEL DEFINITIONS.
  
 B) SPECIFY SAFETYGLASS AT EXISTING BATH WINDOW AND
 AT MASTER BATH ROMAN TUB AS REQUIRED BY SEC. R308.4
 2004 FLORIDA RESIDENTIAL CODE.
  
 C) SPECIFY CALCULATED DESIGN PRESSURES FOR GARAGE
 DOOR.
  
 9- ROOF PITCH IS 3.375:12. NEED TO SPECIFY DOUBLE
 DOUBLE LAYER OF UNDERLAYMENT AS REQUIRED BY SEC.
 R905.2.7 2004 FLORIDA RESIDENTIAL CODE.
  
 10- TYPICAL WALL SECTION. SPECIFY FIREBLOCKING AS
 REQUIRED BY SEC. R602.8 2004 FLORIDA RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (5610805-6712

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-06-14 Cont ID  
Sent By btrobaug Date 2007-06-14 Time 16:33 Rev Time 0.00
Received By btrobaug Date 2007-06-14 Time 15:57 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-01-03 Cont ID  
Sent By btrobaug Date 2007-01-03 Time 07:48 Rev Time 0.50
Received By btrobaug Date 2007-01-02 Time 15:41 Sent To P
Notes
2007-01-03 07:38:59 
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-11-03 Cont ID  
Sent By btrobaug Date 2006-11-03 Time 10:08 Rev Time 0.75
Received By btrobaug Date 2006-11-03 Time 08:41 Sent To P
Notes
2006-11-03 10:08:07 
  
 INCOMPLETE INFORMATION
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} INDICATE CONDUIT AND CONDDUCTOR SIZE AND TYPE FOR
 THE SERVICE RISER. 215.5.
  
 2} PROVIDE A PANEL SCHEDULE PER 408.4. FOR PANEL LISTED
 AS EMERGENCY. THERE ARE NO BRANCH CIRCUITS SHOWN FOR
 THIS 20 CIRCUIT PANEL.
  
 3} PLEASE SHOW LOAD CALCULATIONS PER 220.3SECTION I
 STANDARD METHOD OR OPTIONAL METHOD SECTION III.
  
 4} 210.52(C)(1) WALL COUNTER SPACES. A RECEPTACLE
 OUTLET SHALL BE INSTALLED AT EACH WALL COUNTER SPACE
 THAT IS 300 MM (12 IN.) OR WIDER. RECEPTACLE OUTLETS
 SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE
 IS MORE THAN 600 MM (24 IN.) MEASURED HORIZONTALLY FROM
 A RECEPTACLE OUTLET IN THAT SPACE.
  
 5} 210.8(A) DWELLING UNITS. ALL 125-VOLT, SINGLE-PHASE,
 15- AND 20-AMPERE RECEPTACLES INSTALLED IN THE
 LOCATIONS SPECIFIED IN (1) THROUGH (8) SHALL HAVE
 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR
 PERSONNEL.
 (1) BATHROOMS
  
 6} 210.63 HEATING, AIR-CONDITIONING, AND REFRIGERATION
 EQUIPMENT OUTLET.
 A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING,
 AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE
 RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND
 WITHIN 7.5 M (25 FT) OF THE HEATING, AIR-CONDITIONING,
 AND REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET
 SHALL NOT BE CONNECTED TO THE LOAD SIDE OF THE
 EQUIPMENT DISCONNECTING.
  
 7} SMOKE DETECTORS MUST BE INSTALLED TO COMPLY WITH
 R313.1 RESIDENTIAL FLORIDA BUILDING CODE. SEE FRONT
 BEDROOM.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-10-05 Cont ID  
Sent By adarroug Date 2007-10-05 Time 14:15 Rev Time 0.00
Received By adarroug Date 2007-10-05 Time 14:15 Sent To P
Notes
2007-10-05 14:15:53TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-06-13 Cont ID  
Sent By adarroug Date 2007-06-13 Time 16:34 Rev Time 0.00
Received By adarroug Date 2007-06-13 Time 16:34 Sent To E
Notes
2007-06-13 16:34:57TO "BTROBAUGH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-05-29 Cont ID  
Sent By adarroug Date 2007-05-29 Time 10:13 Rev Time 0.00
Received By adarroug Date 2007-05-29 Time 10:13 Sent To B
Notes
2007-05-29 10:14:13TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-02-06 Cont ID  
Sent By adarroug Date 2007-02-06 Time 13:56 Rev Time 0.00
Received By adarroug Date 2007-02-06 Time 13:56 Sent To B
Notes
2007-02-06 13:56:55TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-12-29 Cont ID  
Sent By adarroug Date 2006-12-29 Time 09:47 Rev Time 0.00
Received By adarroug Date 2006-12-29 Time 09:47 Sent To E
Notes
2006-12-29 09:47:29TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-22 Cont ID  
Sent By adarroug Date 2006-12-22 Time 09:02 Rev Time 0.00
Received By adarroug Date 2006-12-22 Time 09:02 Sent To Z
Notes
2006-12-22 09:02:26TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-01 Cont ID  
Sent By adarroug Date 2006-11-01 Time 18:50 Rev Time 0.00
Received By adarroug Date 2006-11-01 Time 18:50 Sent To E
Notes
2006-11-01 18:50:34TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-11-09 Cont ID  
Sent By jgomez Date 2006-11-09 Time 19:01 Rev Time 0.00
Received By jgomez Date 2006-10-23 Time 13:13 Sent To  
Notes
2006-10-23 13:13:38TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-01-09 Cont ID  
Sent By tgordon Date 2007-01-09 Time 10:54 Rev Time 0.25
Received By tgordon Date 2007-01-09 Time 10:54 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-11-06 Cont ID  
Sent By tgordon Date 2006-11-06 Time 09:50 Rev Time 0.40
Received By tgordon Date 2006-11-06 Time 09:50 Sent To B
Notes
2006-11-06 09:54:05*** DENIED ***
 1) RETURN AIR TRANSFER DUCTS TO ALL BEDROOMS ARE TO
 SMALL.
 BALANCED RETURN AIR.
 MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-10-17 Cont ID  
Sent By mperson Date 2007-10-17 Time 14:04 Rev Time 0.00
Received By mperson Date 2007-10-17 Time 14:04 Sent To PC
Notes
2007-10-17 14:06:31REVISION: "OK" SHEET 1, CHANGED INTERIOR ELECTRIC WATER
 HEATER TO AN EXTERIOR GAS TANKLESS WATER HEATER.
 NOTE: GAS PERMIT HAS BEEN APPLIED FOR.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-01-08 Cont ID  
Sent By mperson Date 2007-01-08 Time 16:07 Rev Time 0.33
Received By mperson Date 2007-01-08 Time 16:07 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-11-06 Cont ID  
Sent By mperson Date 2006-11-06 Time 08:34 Rev Time 0.45
Received By mperson Date 2006-11-06 Time 08:33 Sent To M
Notes
2006-11-06 09:01:42UNSAT
 REFERENCE: FBC-2004 PLUMBING
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW ON THE RESUBMITTAL TO MEET CODE
 COMPLIANCE:
  
 1. IN BATH #2 THE TUB AND SHOWER NEEDS A VENT PER
 FBC-2004 PLUMBING SECTION 909.1 WET VENTS.
  
 2. IN BATH #2 THE FLOOR DRAIN INDICATED NEEDS A TRAP
 PRIMER PER FBC-2004 PLUMBING SECTION 1002.4 TRAP SEAL.
  
 3. IN THE KITCHEN THE AIR ADMITTANCE VALVE IS
 INDICATED IN THE WRONG PLACE PER FBC-2004 PLUMBING
 SECTION 917.4 LOCATION. PLEASE INDICATE THE DISH WASHER
 DRAIN ON THE RESUBMITTAL.
  
 4. IN THE MASTER BATH THE SHOWER NEEDS A VENT PER
 FBC-2004 PLUMBING SECTION 909.1 WET VENTS.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2008-02-28 Cont ID  
Sent By choops Date 2008-02-28 Time 15:42 Rev Time 0.00
Received By choops Date 2008-02-28 Time 15:42 Sent To PC
Notes
2008-02-28 15:42:59***APPROVED - LANDSCAPE PLAN SUBMITTAL***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-12-27 Cont ID  
Sent By mmclean Date 2006-12-27 Time 17:44 Rev Time 0.00
Received By mmclean Date 2006-12-27 Time 17:44 Sent To I
Notes
2006-12-27 17:56:31NOTE: THE PROPOSED GARAGE MUST NOT BE USED FOR LIVING
 SPACE.
 NOTE: SEPARATE PERMIT SHALL BE PULLED FOR
 POOL/SPA/DECK, SHOWING THE POOL EQUIPMENT ON TWO COPIES
 OF SURVEYS.
 NOTE: SEPARATE PERMIT SHALL BE PULLED FOR FENCE WITH
 EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH
 UTILITY DEPT AND BELLSOUTH, ADELPHIA/COMCAST, FPL,
 FLORIDA PUBLIC UTILITIES.
 NOTE: THE PROPOSED A/C UNIT SHALL NOT BE CLOSER THAN
 1FT FROM SIDE PROPERTY LINE.
 NOTE: THE WIDTH OF PROPOSED DRIVEWAY SHALL BE A MINIMUM
 OF 8.5FT WIDE.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-10-30 Cont ID  
Sent By mmclean Date 2006-10-30 Time 16:20 Rev Time 0.00
Received By mmclean Date 2006-10-30 Time 16:20 Sent To I
Notes
2006-10-30 16:43:25DENIED,
 1. PLEASE SHOW ALL PROPOSED WORK ON THE TWO COPIES OF
 SURVEYS. (SURVEY IS THE LEGAL DOC).
 2. SITEPLANS SUBMITTED DOES NOT MATCH THE SETBACKS AS
 INDICATED ON SURVEY.
 3. PLEASE MARK ON THE TWO COPIES OF SURVEYS IF THE SHED
 WILL BE DEMOLISHED.
 4. THE PROPOSED DRIVEWAY MUST MEET THE CURRENT CODE OF
 8.5FT WIDE (YOU WILL NEED TO MEET THE REQUIREMENT FOR
 LANDSCAPE WITHIN THE 25FT FRONT SETBACK).
 5. PLEASE SHOW THE LOCATION OF THE A/C UNIT ON TWO
 COPIES OF SURVEYS.
 6. MUST PULL A SEPARATE PERMIT FOR FENCE/GATE WITH
 EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH
 UTILITY DEPT. IF THE FENCE GATE IS CLOSING ACCESS TO
 THE 5FT U.E. ALL RELEASES WILL BE NEEDED (BELLSOUTH,
 ADELPHIA, FPL, FLORIDA PUBLIC UTILITIES, CITY OF WEST
 PALM BEACH UTILITY DEPT).
 7. CANNOT BUILD FENCE ETC INTO THE 5FT U.E. IN THE REAR
 OF THE PROPERTY.
  
 NOTE: THE PROPOSED GARAGE CANNOT BE USED FOR LIVING
 SPACE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720