| 2007-02-26 11:43:17 | |
| | |
| | PROJECT: 2660 TECUMSEH DRIVE: NEW PLANS SUBMITTED |
| | DESIGNED BY TARNOWSKI ENGINEERING. |
| | |
| | |
| | 1) AS PER FBC SECTION 2002.2, THE DESIGN, FABRICAITON |
| | AND ASSEMBLY OF STRUCTURAL ALUMINUM FOR BUILDINGS OR |
| | STRUCTURES SHALL CONFORM TO AA ASM 35 AND |
| | SPECIFICATIONS FOR ALUMINUM STRUCTURES, ALUMINUM DESIGN |
| | MANUAL, PART 1-A AND 1-B OF THE ALUMINUM ASSOCIATION. |
| | |
| | 2) FBC SECTION 2002.3.1 ACTUAL WALL THICKNESS OF |
| | EXTRUDED ALUMINUM MEMBERS SHALL NOT BE LESS THAN .040 |
| | INCH. |
| | |
| | 3) DISSIMILAR MATERIALS: AS PER FBC SECTION 2003.8.4.2, |
| | ALUMINUM CONTACTING METALS NOT CONSIDERED COMPATIBLE |
| | SHALL BE PROTECTED AS FOLLOWS: |
| | A)PAINTING THE DISSIMILAR METAL WITH A |
| | PRIME COAT OF ZINC-CHROMATE PRIMER OR OTHER SUITABLE |
| | PRIMER FOLLOWED BY 1 OR 2 COATS OF ALUMINUM MEATAL AND |
| | MASONRY PAINT OR OTHER SUITABLE PROTECTIVE COATING, |
| | EXCLUDING THOSE CONTAING LEAD PIGMENTATION. |
| | |
| | B) PAINTING THE DISSIMILAR METAL WITH A |
| | COATING OF A HEAVY-BODIED BITUMINOUS PAINT. |
| | |
| | C)PLACING A GOOD QUALITY CAULKING |
| | MATERIAL BETWEEN THE ALUMINUM AND THE DISSIMILAR |
| | METAL. |
| | |
| | D) APPLYING A NONABSORPTIVE TAPE OR |
| | GASKET. |
| | |
| | E) HOT DIPPED GALVANIZING OR ZINC-PLATING |
| | STEEL MEMBERS AFTER FABRICATION. |
| | |
| | 4) AS PER FBC 2003.8.4.3, DISSIMILAR METAKLS SHALL BE |
| | PAINTED IF USED IN LOCATIONS WHERE DRAINAGE FROM THEM |
| | PASSES OVER ALUMINUM. |
| | |
| | 5) FBC 2003.8.4.4 ALUMINUM SURAFACES IN CONTACT WITH |
| | LIME-MORTAR, CONCRETE OR OTHER MASONRY MATERIALS SHALL |
| | BE PROTECTED WITH ALKALI-RESISTANT COATINGS SUCH AS |
| | HEAVY BODIED BITUMINOUS PAINT OR WATER WHITE |
| | METHACRYLATE LACQUER. |
| | |
| | 6) FBC 2003.8.405 ALUMINUM IN CONTACT WITH WOOD OR |
| | OTHER ABSORBING MATERIALS WHICH MAY BECOME REPEATEDLY |
| | WET SHALL BE PAINTED WITH TWO COATS OF ALUMINUM |
| | METAL/MASONRY PAINT OR A COAT OF HEAVY BODIED |
| | BITUMINOUS PAINT, OR THE WOOD OR OTHER ABSORBING |
| | MATERIAL SHALL BE PAINTED WITH TWO CAOTS OF ALUMINUM |
| | HOUSE PAINT AND THE JOINTS SEALED WITH A GOOD QUALITY |
| | CAULKING COMPOUND. |
| | |
| | 7) METAL FRAMING WITHIN 5 FT. OF A SWIMMING POOL SHALL |
| | BE BONDED AS PER NEC 680-26. |
| | |
| | 8) FBC 424.2.17.1.11 STANDARD SCREEN ENCLOSURES SHALL |
| | MEET THE REQUIREMENTS OF SECTION 424.2.17 RESIDENTIAL |
| | SWIMMING BARRIER REQUIREMENT. |