| Plan Review Stops For Permit 06100593 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-15 |
Time |
06:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-15 |
Time |
05:59 |
Sent To |
PC |
|
| Notes |
| 2006-12-15 06:18:31 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST | | | STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-11-15 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-11-15 |
Time |
06:52 |
Sent To |
PC |
|
| Notes |
| 2006-11-15 08:33:45 | BUILDING PLAN REVIEW | | | PERMIT: 06100593 | | | ADD: 2890 GETTYSBURG LN. | | | CONT:SUPERIOR POOL & SPA | | | TEL: (561)333-4546 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW :1ST | | | ACTION: DENIED | | | | | | 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW.FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC*.NOTE: ADDITIONAL FEES ARE DUE IN THE | | | AMOUNT OF $179.78.THIS FEE SHALL BE PAID WHEN | | | RESUBMITTING. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-22 |
Time |
15:04 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-12-22 |
Time |
15:02 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-12 |
Time |
13:54 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-12-12 |
Time |
13:42 |
Sent To |
P |
|
| Notes |
| 2006-12-12 13:54:44 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1}SUBMIT DETAILS FOR THE PANEL SHOWN ON THE | | | SCHEMATIC, FEEDER AND CONDUIT SIZE AND TYPE, PANEL | | | RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | | | | PAY FEES PRIOR TO RESUBMITTING. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-31 |
Time |
15:47 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-10-31 |
Time |
15:47 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-22 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-22 |
Time |
11:47 |
Sent To |
E |
|
| Notes |
| 2006-12-22 11:48:05 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-12 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-12 |
Time |
09:12 |
Sent To |
E |
|
| Notes |
| 2006-12-12 09:14:49 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-04 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-04 |
Time |
14:02 |
Sent To |
Z |
|
| Notes |
| 2006-12-04 14:03:05 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-31 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-31 |
Time |
09:00 |
Sent To |
E |
|
| Notes |
| 2006-10-31 09:00:29 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-11-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-18 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2006-10-18 15:36:57 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-02 |
Time |
08:30 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-01-02 |
Time |
08:30 |
Sent To |
PC |
|
| Notes |
| 2007-01-02 08:32:34 | NOTE: NEW SHEETS, NO CHANGES TO PLUMBING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-12 |
Time |
16:39 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-12-12 |
Time |
16:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-01 |
Time |
14:28 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-11-01 |
Time |
14:28 |
Sent To |
B |
|
| Notes |
| 2006-11-01 14:46:13 | UNSAT | | | REFERENCE: FBC-2004, SEC. 424.2 OR FBC RES.-2004 SEC. | | | 4101 SWIMMING POOLS: | | | | | | THE FOLLOWING INFORMATION IS REQUIRED FOR PLUMBING PLAN | | | REVIEW: | | | | | | 1. THE MAGNA SWEEP AUTOMATIC BUILT-IN POOL CLEANING | | | AND CIRCULATION SYSTEM ATTACHED ISNOT INDICATED ON | | | THE POOL PLAN, SPECIFICATIONS, PLUMBING SCHEMATIC OR | | | THE ADDITIONAL FEATURES AND ARE NOT SIGNED AND SEALED | | | BY ENGINEER OF RECORD WAYNE MARKHAM BENNETT P. E. | | | #57216. IF THIS SYSTEM IS TO BE USED THE ABOVE COMMENTS | | | MUST BE ADDRESSED FOR PLUMBING PLAN REVIEW APPROVAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-08 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-08 |
Time |
14:43 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-10-28 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-10-28 |
Time |
10:28 |
Sent To |
I |
|
| Notes |
| 2006-10-28 10:29:42 | DENIED, | | | 1. PLEASE SHOW THE PROPOSED POOL EQUIPMENT ON TWO | | | COPIES OF SURVYES. | | | 2. THE POOL EQUIPMENT IS NOT SHOWN ON THE TWO COPIES OF | | | SURVEYS SUBMITTED. | | | | | | SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|