Plan Review Details - Permit 06100593
Plan Review Stops For Permit 06100593
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-12-15 Cont ID  
Sent By mjacobs Date 2006-12-15 Time 06:39 Rev Time 0.00
Received By mjacobs Date 2006-12-15 Time 05:59 Sent To PC
Notes
2006-12-15 06:18:31BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-11-15 Cont ID  
Sent By mjacobs Date 2006-11-15 Time 09:29 Rev Time 0.00
Received By mjacobs Date 2006-11-15 Time 06:52 Sent To PC
Notes
2006-11-15 08:33:45BUILDING PLAN REVIEW
 PERMIT: 06100593
 ADD: 2890 GETTYSBURG LN.
 CONT:SUPERIOR POOL & SPA
 TEL: (561)333-4546
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW :1ST
 ACTION: DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW.FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*.NOTE: ADDITIONAL FEES ARE DUE IN THE
 AMOUNT OF $179.78.THIS FEE SHALL BE PAID WHEN
 RESUBMITTING.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-22 Cont ID  
Sent By btrobaug Date 2006-12-22 Time 15:04 Rev Time 0.33
Received By btrobaug Date 2006-12-22 Time 15:02 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-12-12 Cont ID  
Sent By btrobaug Date 2006-12-12 Time 13:54 Rev Time 0.33
Received By btrobaug Date 2006-12-12 Time 13:42 Sent To P
Notes
2006-12-12 13:54:44 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1}SUBMIT DETAILS FOR THE PANEL SHOWN ON THE
 SCHEMATIC, FEEDER AND CONDUIT SIZE AND TYPE, PANEL
 RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC.
  
 PAY FEES PRIOR TO RESUBMITTING.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-10-31 Cont ID  
Sent By btrobaug Date 2006-10-31 Time 15:47 Rev Time 0.33
Received By btrobaug Date 2006-10-31 Time 15:47 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-12-22 Cont ID  
Sent By adarroug Date 2006-12-22 Time 11:47 Rev Time 0.00
Received By adarroug Date 2006-12-22 Time 11:47 Sent To E
Notes
2006-12-22 11:48:05TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-12-12 Cont ID  
Sent By adarroug Date 2006-12-12 Time 09:12 Rev Time 0.00
Received By adarroug Date 2006-12-12 Time 09:12 Sent To E
Notes
2006-12-12 09:14:49TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-04 Cont ID  
Sent By adarroug Date 2006-12-04 Time 14:02 Rev Time 0.00
Received By adarroug Date 2006-12-04 Time 14:02 Sent To Z
Notes
2006-12-04 14:03:05TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-31 Cont ID  
Sent By adarroug Date 2006-10-31 Time 09:00 Rev Time 0.00
Received By adarroug Date 2006-10-31 Time 09:00 Sent To E
Notes
2006-10-31 09:00:29TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-11-15 Time   Rev Time 0.00
Received By adarroug Date 2006-10-18 Time 15:36 Sent To  
Notes
2006-10-18 15:36:57TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-01-02 Cont ID  
Sent By mperson Date 2007-01-02 Time 08:30 Rev Time 0.45
Received By mperson Date 2007-01-02 Time 08:30 Sent To PC
Notes
2007-01-02 08:32:34NOTE: NEW SHEETS, NO CHANGES TO PLUMBING.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-12-12 Cont ID  
Sent By mperson Date 2006-12-12 Time 16:39 Rev Time 0.33
Received By mperson Date 2006-12-12 Time 16:39 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-11-01 Cont ID  
Sent By mperson Date 2006-11-01 Time 14:28 Rev Time 0.45
Received By mperson Date 2006-11-01 Time 14:28 Sent To B
Notes
2006-11-01 14:46:13UNSAT
 REFERENCE: FBC-2004, SEC. 424.2 OR FBC RES.-2004 SEC.
 4101 SWIMMING POOLS:
  
 THE FOLLOWING INFORMATION IS REQUIRED FOR PLUMBING PLAN
 REVIEW:
  
 1. THE MAGNA SWEEP AUTOMATIC BUILT-IN POOL CLEANING
 AND CIRCULATION SYSTEM ATTACHED ISNOT INDICATED ON
 THE POOL PLAN, SPECIFICATIONS, PLUMBING SCHEMATIC OR
 THE ADDITIONAL FEATURES AND ARE NOT SIGNED AND SEALED
 BY ENGINEER OF RECORD WAYNE MARKHAM BENNETT P. E.
 #57216. IF THIS SYSTEM IS TO BE USED THE ABOVE COMMENTS
 MUST BE ADDRESSED FOR PLUMBING PLAN REVIEW APPROVAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-12-08 Cont ID  
Sent By mmclean Date 2006-12-08 Time 14:43 Rev Time 0.00
Received By mmclean Date 2006-12-08 Time 14:43 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-10-28 Cont ID  
Sent By mmclean Date 2006-10-28 Time 10:28 Rev Time 0.00
Received By mmclean Date 2006-10-28 Time 10:28 Sent To I
Notes
2006-10-28 10:29:42DENIED,
 1. PLEASE SHOW THE PROPOSED POOL EQUIPMENT ON TWO
 COPIES OF SURVYES.
 2. THE POOL EQUIPMENT IS NOT SHOWN ON THE TWO COPIES OF
 SURVEYS SUBMITTED.
  
 SEC 94-303 MECHANICAL/POOL
 EQUIPMENT/GENERATOR MAY NOT PROJECT MORE
 THAN FOUR FEET INTO A SETBACK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720