Plan Review Details - Permit 06100547
Plan Review Stops For Permit 06100547
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-01-31 Cont ID  
Sent By lmartine Date 2007-01-31 Time 14:20 Rev Time 0.00
Received By lmartine Date 2007-01-31 Time 14:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-01-30 Cont ID  
Sent By lmartine Date 2007-01-30 Time 16:45 Rev Time 0.00
Received By lmartine Date 2007-01-30 Time 16:26 Sent To  
Notes
2007-01-30 16:38:16 
 BUILDING REVIEW COMMENTS
 ------------ ------------ ----------------
  
  
 PROVIDE RECORDED NOTICE OF COMMENCEMENT.
  
 SHEET D-2 IS MISSING FROM ONE OF THE SETS OF PLANS.
  
 SUBMIT SECOND SET OF TRUSS ENGINEERING.
  
 PROVIDE FINISH FLOOR ELEVATION, MINIMUM ELEVATION FOR
 NEW AND EXISTING SHALL BE 7.5' OR BETTER.
  
  
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-10-30 Cont ID  
Sent By alange Date 2006-10-30 Time 09:26 Rev Time 0.00
Received By alange Date 2006-10-30 Time 09:26 Sent To  
Notes
2006-10-30 10:45:16DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY
 SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT
 COMMENCED WITHIN 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.WIND DESIGN INFORMATION SECTION SHOWN AS FBC 1606.2
 IS INCORRECT.
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS PER 2004 FBC.
  
 5.PRODUCT APPROVALS REQUIRED FOR HARDIEPLANK SIDING.
 TWO SETS OF ALL PRODUCT APPROVALS REQUIRED.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY
 ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL
 ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT
 LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF
 THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC
 FORM PER RULE 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3.
  
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER
 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE
 APPROVED PRIOR TO INSTALLATION.
  
 9.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR
 A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS
 WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC
 EXISTING BUILDING 301.5
  
 10.R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHESWITHIN THE FIRST 10 FEET.
  
 11.SHOW METHOD OF SLAB TIE-IN FROM EXISTING TO NEW.
  
  
 12.SHOW FOOTING DETAIL A MINIMUM OF 12' BELOW GRADE.
 R-403.1.4
  
 13.SUBMIT A FOUNDATION PLAN.
  
 14.EAST EXISTING ELEVATION DOES NOT MATCH FLOOR
 PLAN.
  
 15.DOOR AND WINDOW SCHEDULE,DOOR #1 IS INCORRECT,
 OVERHEAD DOOR NOT SHOWN, WINDOW "C" IS SHOWN AS FIXED.
 THAT WON'T MEET EMERGENCY ESCAPE AND RESCUE OPENING
 REQUIREMENTS OF BEDROOMS.FRENCH DOOR IN LIVING ROOM
 IS NOT ON SCHEDULE.
  
 16. LEGEND FOR FLOOR PLAN DOES NOT PACH WHAT IS SHOWN.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE
 COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DEPARTMENT
 561-805-6672
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-07-26 Cont ID  
Sent By btrobaug Date 2007-07-26 Time 15:09 Rev Time 0.00
Received By btrobaug Date 2007-07-25 Time 16:24 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-07-19 Cont ID  
Sent By btrobaug Date 2007-07-19 Time 16:02 Rev Time 0.00
Received By btrobaug Date 2007-07-19 Time 15:37 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-08 Cont ID  
Sent By btrobaug Date 2006-12-08 Time 11:08 Rev Time 0.50
Received By btrobaug Date 2006-12-08 Time 07:49 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-10-26 Cont ID  
Sent By btrobaug Date 2006-10-26 Time 14:53 Rev Time 0.75
Received By btrobaug Date 2006-10-26 Time 13:40 Sent To M
Notes
2006-10-26 13:49:21 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} LOCATE THE NEW PANEL ON THE DRAWING FLOOR PLAN SO
 THAT COMPLIANCE WITH 230.70(A)(1) CAN BE REVIEWED. A
 DISCONNECT MAY BE NEEDED AT THE METER FOR COMPLIANCE.
  
 2} THE AIR HANDLER CIRCUIT IN THE PANEL SCHEDULE DOES
 NOT INDICATE THE WATTAGE OF THE UNIT, BUT THE
 CALCULATION INDICATES 7500 WATTS, IN WHICH CASE THE 80
 AMP BREAKER IS TOO LARGE PER 240.4, 310.16.
  
 3} THE SPECS ON SHEET H1 INDICATE 10K HEAT , THE CALCS
 HAVE 7500 LISTED. PLEASE CORRELATE AND ADJUST
 CALCULATIONS AS NEEDED.
  
 4}} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT
 CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE
 EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS
 EQUAL TO OR GREATER THAN THE AVAILABLE FAULT.
  
 5} THE RECEPTACLE SPACING IN THE BATHROOMS MUST COMPLY
 WITH 210.52(D).
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-04 Cont ID  
Sent By adarroug Date 2006-12-04 Time 11:09 Rev Time 0.00
Received By adarroug Date 2006-12-04 Time 11:09 Sent To E
Notes
2006-12-04 11:09:51TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-01-31 Cont ID  
Sent By mmiller Date 2006-11-29 Time 19:34 Rev Time 0.00
Received By lmartine Date 2006-11-29 Time 19:33 Sent To B
Notes
2006-11-29 19:34:00SENT TO ART LANGE'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-30 Cont ID  
Sent By alange Date 2006-10-30 Time 09:26 Rev Time 0.00
Received By alange Date 2006-10-16 Time 13:28 Sent To  
Notes
2006-10-16 13:28:47TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-12-08 Cont ID  
Sent By tgordon Date 2006-12-08 Time 13:44 Rev Time 0.30
Received By tgordon Date 2006-12-08 Time 13:44 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-10-26 Cont ID  
Sent By tgordon Date 2006-10-26 Time 15:43 Rev Time 0.40
Received By tgordon Date 2006-10-26 Time 15:43 Sent To P
Notes
2006-10-26 15:51:00*** DENIED ***
 1) PLEASE SUBMIT TWO COPYS OF THE ENERGY CAL'S. AND
 MANUAL J CAL'S.
  
 2) 24X24 RETURN AIR GRILL IN LIVING ROOM IS SHOWN AS A
 SUPPLY AIR GRILL, PLEASE CORRECT.
  
 3) RETURN AIR TRANSFER DUCT IN MASTER SUITE NEEDS TO BE
 14", PLEASE CORRECT, SEE NOTE #4.
  
 4) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-12-08 Cont ID  
Sent By mperson Date 2006-12-08 Time 11:48 Rev Time 0.33
Received By mperson Date 2006-12-08 Time 11:48 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-10-27 Cont ID  
Sent By mperson Date 2006-10-27 Time 14:11 Rev Time 0.55
Received By mperson Date 2006-10-27 Time 14:10 Sent To B
Notes
2006-10-27 15:16:54UNSAT
 REFERENCE: FBC-2004 PLUMBING, FBC-2004 CHAPTER 1
  
 THE FOLLOWING INFORMATION IS REQUIRED FOR PLUMBING PLAN
 REVIEW ON THE SANITARY PLUMBING RISER DIAGRAM ON SHEET
 PR-1. PLEASE REFERENCE THE CORRECTED SANITARY PLUMBING
 RISER DIAGRAM IN RED INK ON SHEET PR-1 FOR THE
 RESUBMITTAL:
  
 1. THE MASTER BATH INDICATED ON SHEET PR-1 IS WRONG
 PER THE FOLLOWING.
 A. PER FBC-2004, PLUMBING, SECTION 909.1
 WET VENT PERMITTED: ONLY THE FIXTURES
 WITHIN THE BATHROOM GROUPS SHALL CONNECT
 TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. ANY ADDITIONAL FIXTURES SHALL
 DISCHARGE DOWNSTREAM OF THE WET VENT.
  
 2. PER FBC-2004 CHAPTER 1, SEC. 106.3.5.4 RESIDENTIAL
 (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS. (NOTE: NOT ALL TRAPS ARE SIZED ON
 SHEET PR-1)
  
 3. THE DOUBLE BOWL KITCHEN SINK WITH DISHWASHER IS
 INDICATED ON SHEET PR-1 WRONG, AND DOES NOT REFLECT THE
 FLOOR PLAN. PLEASE REFERENCE THE CORRECTED DRAWING IN
 RED INK FOR THE RESUBMITTAL.
  
 4. THE WASHING MACHINE ON SHEET PR-1 IS NOT INDICATED
 ON THE EXISTING FLOOR PLAN, THEREFORE IT IS ASSUMED THE
 WASHING MACHINE IS NEW. PER FBC-2004 PLUMBING, SECTIONS
 406.3 AND 802.4 THE FOLLOWING IS REQUIRED.
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY
 TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING. PLEASE INDICATE THE STANDPIPE ON THE
 RESUBMITTAL.
 (C)708.9 ACCESS SHALL BE PROVIDED FOR ALL CLEANOUTS.
 PLEASE INDICATE THE WASHING MACHINE CLEANOUT FOUR FEET
 ABOVE FINNISH FLOOR (4' AFF).
 (D)PER FBC-2004 PLUMBING, SECTION
 901.2.1 VENTING REQUIRED: EVERY TRAP AND
 TRAPPED FIXTURE SHALL BE VENTED IN
 ACCORDANCE WITH ONE OF THE VENTING
 METHODS SPECIFIED IN THIS CHAPTER. (NOTE: THE WASHING
 MACHINE NEEDS A VENT.)
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  