Plan Review Details - Permit 06100406
Plan Review Stops For Permit 06100406
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-12-01 Cont ID  
Sent By alange Date 2006-12-01 Time 15:27 Rev Time 0.00
Received By alange Date 2006-12-01 Time 15:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-11-22 Cont ID  
Sent By alange Date 2006-11-22 Time 13:15 Rev Time 0.00
Received By alange Date 2006-11-22 Time 13:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-10-27 Cont ID  
Sent By alange Date 2006-10-27 Time 09:11 Rev Time 0.00
Received By alange Date 2006-10-27 Time 09:11 Sent To  
Notes
2006-10-27 09:29:16DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY
 SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT
 COMMENCED WITHIN 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO ORIGINAL SIGNED AND SEALED SURVEYS.FS
 472.025
  
 4.SIGN OWNER AGENT ON ENEGY CALCS ENERGY CALCS PER
 2004 FBC.
  
 5.SEPERATE PERMIT REQUIRED FOR TILE ROOF.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY
 ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL
 ATTACHED.
 PLEASE DONT ATTACH PRODUCT APPROVALS TO PLANS.
  
 PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT
 LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF
 THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC
 FORM PER RULE 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3.
  
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER
 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE
 APPROVED PRIOR TO INSTALLATION.
  
 9.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR
 A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS
 WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC
 EXISTING BUILDING 301.5
  
 10.R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHESWITHIN THE FIRST 10 FEET.
  
 11.TYPE 6 CONSTRUCTION DOES NOT EXIST UNDER THE 2004
 FBC
  
 12.SEE REFERENCE TO ASCE-7-98 THROUGH OUT PLANS
 SHOULD BE ASCE 7-02
  
 13.R403.1.4 MINIMUM DEPTH.
 ALL EXTERIOR FOOTINGS SHALL BE PLACED AT LEAST 12
 INCHES BELOW THE UNDISTURBED GROUND SURFACE.
  
 14.BUCK SHALL PROVIDE FULL SUPORT OF THE FRAME. SEE
 BEVELED BUCK SHOWN.
 UNLESS OTHERWISE TESTED, BUCKS SHALL EXTEND BEYOND THE
 INTERIOR FACE OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS PROVIDED. SHIMS SHALL BE
 MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE
 LOADS, LOCATED AND APPLIED IN A THICKNESS CAPABLE OF
 SUSTAINING APPLICABLE LOADS. ANCHORS SHALL BE PROVIDED
 TO TRANSFER LOAD FROM THE WINDOW OR DOOR FRAME ASSEMBLY
 TO THE SECURED WOOD BUCK.R613.6.2
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE
 COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DEPARTMENT
 561-805-6672
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-11-30 Cont ID  
Sent By btrobaug Date 2006-11-30 Time 17:27 Rev Time 0.50
Received By btrobaug Date 2006-11-30 Time 17:19 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-11-20 Cont ID  
Sent By btrobaug Date 2006-11-20 Time 17:15 Rev Time 0.33
Received By btrobaug Date 2006-11-20 Time 17:06 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-10-24 Cont ID  
Sent By btrobaug Date 2006-10-24 Time 13:22 Rev Time 0.50
Received By btrobaug Date 2006-10-24 Time 13:12 Sent To M
Notes
2006-10-24 13:22:54 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE ARCHITECTURAL FIRM MUST DISPLAY THE CERTIFICATE
 OF AUTHORIZATION ON THE TITLE BLOCK PER 481.221 (8).
  
 2} SMOKE DETECTORS ARE REQUIRED TO BE INTERCONNECTED
 PER R313.1 FBC,
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-30 Cont ID  
Sent By adarroug Date 2006-11-30 Time 16:03 Rev Time 0.00
Received By adarroug Date 2006-11-30 Time 16:03 Sent To E
Notes
2006-11-30 16:04:05TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-11-12 Cont ID  
Sent By adarroug Date 2006-11-12 Time 12:43 Rev Time 0.00
Received By adarroug Date 2006-11-12 Time 12:43 Sent To E
Notes
2006-11-12 12:43:51TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-11-09 Cont ID  
Sent By adarroug Date 2006-11-09 Time 14:08 Rev Time 0.00
Received By adarroug Date 2006-11-09 Time 14:08 Sent To Z
Notes
2006-11-09 14:08:33TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-17 Cont ID  
Sent By adarroug Date 2006-10-17 Time 16:52 Rev Time 0.00
Received By adarroug Date 2006-10-17 Time 16:52 Sent To E
Notes
2006-10-17 16:53:01TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-27 Cont ID  
Sent By alange Date 2006-10-27 Time 09:11 Rev Time 0.00
Received By alange Date 2006-10-13 Time 10:29 Sent To  
Notes
2006-10-13 10:29:50TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-12-01 Cont ID  
Sent By tgordon Date 2006-12-01 Time 08:28 Rev Time 0.20
Received By tgordon Date 2006-12-01 Time 08:28 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-11-21 Cont ID  
Sent By tgordon Date 2006-11-21 Time 10:45 Rev Time 0.20
Received By tgordon Date 2006-11-21 Time 10:45 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-10-25 Cont ID  
Sent By tgordon Date 2006-10-25 Time 15:56 Rev Time 0.25
Received By tgordon Date 2006-10-25 Time 15:56 Sent To B
Notes
2006-10-25 15:59:14*** DENIED ***
 1) PROVIED RETURN AIR FOR NEW BEDROOM, PER 2004 FBC/R
 M1602.4.
 BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-10-25 Cont ID  
Sent By mperson Date 2006-10-25 Time 13:16 Rev Time 0.15
Received By mperson Date 2006-10-25 Time 13:16 Sent To M
Notes
2006-10-25 13:22:04NOTE: POOL PLUMBING PERMIT REQUIRED FOR RELOCATING POOL
 EQUIPMENT.

Review Stop Z ZONING
Rev No 3 Status P Date 2006-12-01 Cont ID  
Sent By alange Date 2006-12-01 Time 15:27 Rev Time 0.00
Received By alange Date 2006-12-01 Time 15:27 Sent To  
Notes
2006-12-01 15:27:33JUST COVERED PATIO, ALREADY APPROVED BY ZONING

Review Stop Z ZONING
Rev No 2 Status F Date 2006-11-11 Cont ID  
Sent By mmclean Date 2006-11-11 Time 14:22 Rev Time 0.00
Received By mmclean Date 2006-11-11 Time 14:22 Sent To I
Notes
2006-11-11 14:27:25DENIED - NEW PLANS
 1. THE DIMENSION OF SITEPLAN DOES NOT MATCH THE SURVEY.
 SURVEYS SHOWS 107.15 AND SITEPLANS SHOWS 75.04.
 2. SITEPLAN DOES NOT SHOW THE SETBACKS OF THE EXISTING
 STRUCTURE AND DOES NOT SHOW ALL THAT IS ON THE SURVEY.
 3. PLEASE SHOW THE PROPOSED WORK ON TWO COPIES OF
 SURVEYS WITH SETBACKS.SURVEY IS LEGAL DOCUMENT.
 4. THE SITEPLAN HAS INSUFFICIENT INFORMATION FOR A
 COMPLETE REVIEW.
 5. ON FLOOR PLANS, PLEASE IDENTIFY THE ROOM THAT WILL
 PROVIDE INTERIOR ACCESS TO NEW ADDITION.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status P Date 2006-10-16 Cont ID  
Sent By kdfreema Date 2006-10-16 Time 11:30 Rev Time 0.00
Received By kdfreema Date 2006-10-16 Time 11:30 Sent To  
Notes
***NONE***