Plan Review Details - Permit 06100279
Plan Review Stops For Permit 06100279
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-02-05 Cont ID  
Sent By spalmer Date 2007-02-05 Time 09:17 Rev Time 0.00
Received By spalmer Date 2007-02-05 Time 09:17 Sent To  
Notes
2007-02-05 09:17:37OKAY PER MYRON JACOBS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-02-01 Cont ID  
Sent By mjacobs Date 2007-02-01 Time 14:10 Rev Time 0.00
Received By mjacobs Date 2007-02-01 Time 10:01 Sent To  
Notes
2007-02-01 16:42:25PLANS AT MJ DESK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-02-01 Cont ID  
Sent By mjacobs Date 2006-11-29 Time 15:53 Rev Time 0.00
Received By mjacobs Date 2006-11-29 Time 06:52 Sent To  
Notes
2006-11-29 15:51:31BUILDING PLAN REVIEW
 PERMIT:06100279
 ADD:319 CLEMATIS ST.
 CONT: ANDOVER CONSTRUCTION
 TEL: (561)638-4993
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
  
 1)THE VALUE ON THE PERMIT HAS NOT BEING CHANGED. IF A
 FAIR MARKET VALUE IS NOT APPLIED, WE WILL CALCULATE THE
 VALUE USING MARSHALL-SWIFT. ICC (BVD), AND MEANS COST
 ANALYSIS SERVICES PER 108.3 FBC*.
  
 2)WHAT TYPE OF MATERIAL WILL BE USED TO INSTALL THE
 ROOF TILES? IF POLYFOAM WILL BE USED SUBMIT THE PRODUCT
 APPROVAL FOR THE POLYFOAM AND MARK CLEARLY ON THE
 PRODUCT APPROVAL THE TABLE WHICH WILL BE USED. THE
 PRODUCT APPROVAL FOR THE MODIFIED BITUMEN ROOF NEEDS TO
 INCICATE WHICH SYSTEM WILL BE USED. EITHER CIRCLE OR
 HI-LIGHT THE APPLICATION TO BE USED.
  
 3)FBC 703.4THE TESTS INDICATED IN SECTIONS 703.4.1
 AND 703.4.2 SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF
 BUILDING MATERIALS AS SET FORTH IN SECTIONS 602.2 ,
 602.3 AND 602.4 IN TYPE I, II, III AND IV CONSTRUCTION.
 THE TERM ?NONCOMBUSTIBLE? DOES NOT APPLY TO THE FLAME
 SPREAD CHARACTERISTICS OF INTERIOR FINISH OR TRIM
 MATERIALS. A MATERIAL SHALL NOT BE CLASSIFIED AS A
 NONCOMBUSTIBLE BUILDING CONSTRUCTION MATERIAL IF IT IS
 SUBJECT TO AN INCREASE IN COMBUSTIBILITY OR FLAME
 SPREAD BEYOND THE LIMITATIONS HEREIN ESTABLISHED
 THROUGH THE EFFECTS OF AGE, MOISTURE OR OTHER
 ATMOSPHERIC CONDITIONS. A DIFFERENT TYPE OF MATERIAL
 WILL HAVE TO BE USED INSTEAD OF THE
 FIRE-RETARDANT-TREATED PLYWOOD.
  
 4) 704.2.1 TYPE I AND II CONSTRUCTION.
 PROJECTIONS FROM WALLS OF TYPE I OR II CONSTRUCTION
 SHALL BE OF NONCOMBUSTIBLE MATERIALS OR COMBUSTIBLE
 MATERIALS AS ALLOWED BY SECTIONS 1406.3 AND 1406.4 .
  
 5)704.11.1 PARAPET CONSTRUCTION.
 PARAPETS SHALL HAVE THE SAME FIRE-RESISTANCE RATING AS
 THAT REQUIRED FOR THE SUPPORTING WALL, AND ON ANY SIDE
 ADJACENT TO A ROOF SURFACE, SHALL HAVE NONCOMBUSTIBLE
 FACES FOR THE UPPERMOST 18 INCHES (457 MM), INCLUDING
 COUNTERFLASHING AND COPING MATERIALS.THE TREATED
 PLYWOOD IS CONSIDERED COMBUSTIBLE UNDER CERTAIN
 CONDITIONS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-11-01 Cont ID  
Sent By mjacobs Date 2006-11-01 Time 15:09 Rev Time 0.00
Received By mjacobs Date 2006-10-31 Time 13:40 Sent To P
Notes
2006-11-01 15:09:17BUILDING PLAN REVIEW
 PERMIT:06100279
 ADD:319 CLEMATIS ST.
 CONT:
 TEL: (561)638-4993
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW1ST
 ACTION: DENIED
  
  
 1)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 -------------------------------------
 ) NUMBER OF UNITS
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) NUMBER OF BEDROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
 ) SQ. FT. UNDER ROOF (TOTAL)
 ) OCCUPANT LOAD
 ) FLOOD ZONE
 ) FLOOD ELEVATION
 )L.O.M.R. .
  
 2)F.S489.113(3)A GENERAL CONTRACTOR SHALL
 SUB-CONTRACT ALLELECTRICAL, MECHANICAL, PLUMBING,
 ROOFING
 SHEET METAL,SWIMMING POOL, AND AIR-CONDITIONING WORK,
 UNLESS SUCH CONTRACTOR HOLDS A STATE CERTIFICATE OR
 REGISTRATION IN THE RESPECTIVE TRADE CATEGORY.
 A LICENSE ROOFING CONTRACTOR WILL HAVE TO DO ALL THE
 ROOFING WORK AT THIS PROJECT.
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE.OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3FBC*.
  
 4)1406.2.2 ARCHITECTURAL TRIM.
 IN BUILDINGS OF TYPE I, II, III AND IV CONSTRUCTION
 THAT DO NOT EXCEED THREE STORIES OR 40 FEET (12 192 MM)
 IN HEIGHT ABOVE GRADE PLANE, EXTERIOR WALL COVERINGS
 SHALL BE PERMITTED TO BE CONSTRUCTED OF WOOD WHERE
 PERMITTED BY SECTION 1405.4 OR OTHER EQUIVALENT
 COMBUSTIBLE MATERIAL. COMBUSTIBLE EXTERIOR WALL
 COVERINGS, OTHER THAN FIRE-RETARDANT-TREATED WOOD
 COMPLYING WITH SECTION 2303.2 FOR EXTERIOR
 INSTALLATION, SHALL NOT EXCEED 10 PERCENT OF AN
 EXTERIOR WALL SURFACE AREA WHERE THE FIRE SEPARATION
 DISTANCE IS 5 FEET (1524 MM) OR LESS. ARCHITECTURAL
 TRIM THAT EXCEEDS 40 FEET (12 192 MM) IN HEIGHT ABOVE
 GRADE PLANE SHALL BE CONSTRUCTED OF APPROVED
 NONCOMBUSTIBLE MATERIALS AND SHALL BE SECURED TO THE
 WALL WITH METAL OR OTHER APPROVED NONCOMBUSTIBLE
 BRACKETS.
  
 5)703.4 NONCOMBUSTIBILITY TESTS.
 THE TESTS INDICATED IN SECTIONS 703.4.1 AND 703.4.2
 SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING
 MATERIALS AS SET FORTH IN SECTIONS 602.2 , 602.3 AND
 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM
 "NONCOMBUSTIBLE" DOES NOT APPLY TO THE FLAME SPREAD
 CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A
 MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE
 BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN
 INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE
 LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF
 AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS.
  
  
 6)602.2 TYPES I AND II.
 TYPE I AND II CONSTRUCTION ARE THOSE TYPES OF
 CONSTRUCTION IN WHICH THE BUILDING ELEMENTS LISTED IN
 TABLE 601 ARE OF NONCOMBUSTIBLE MATERIALS.
  
 7)THE NAIL SPACING FOR THE ROOF SHALL BE IN
 ACCORDANCE WITH TABLE2304.9.1 (Q).
  
 8)61G15-23.001.(1)THE FLORIDA BOARD OF PROFESSIONAL
 ENGINEERS AMENDED IT SEALS RULE EFFECTIVE FEBRUARY5,
 2004 TO ALLOW EMBOSSING SEALS MADE OF MATERIALS OTHER
 THAN METAL AND THE SAME TIME CLEAND UP THE APPERANCE OF
 THE SEAL BY ELEMITATINS OBLOLETE CONTENT AND CHANGING
 THE "CERTIFICATE" TO "LICENSE.
 NOTE: SHEET S1. THE SEALSTILL HAS THE WORD
 "CERTIFICATE" .THIS TYPE OF SEAL EXPIRED DECEMBER 31,
 2005. THE NEW SEAL SHALL HAVE THE WORD "LICENSE".
  
 9) 106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITTING
 BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 SUBMIT THE MATCHING STATE COVER SHEET WITH THE FL# FOR
 EACH PRODUCT APPROVAL. SEE FLORIDABUILDING.ORG FOR
 ADDITIONAL INFORMATION.
  
 10) THIS ROOF IS MISSING OR NOT IN
 COMPLIANCE WITH THE FOLLOW ITEMS:
  
 _XX__ CONTRACTOR DID NOT INDICATE THE ROOF
 PITCH.
  
 _XX__ CONTRACTOR FAILED TO INDICATE WHICH
 SYSTEM TO BE USED.
  
 _XX__THE SYSTEM PROVIDED INDICATES
 LIMITATION# 9, NO ENHANCED
 FASTENING ALLOWED.
  
 11)SHEET A2.0INDICATE THE SCUTTLE HATCHES DETAILS
 IS ON SHEET S-2, HOWEVER, THERE IS NO SHEET S-2. EITHER
 SUBMIT SHEET S-2 OR REVISED THE DRAWINGS TO REFLECT THE
 CORRECT INFORMATION.
  
 12)WHAT IS THE SLOPE OF THE NEW ROOF OVERHANG.
 INDICATE ON THE DRAWINGS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-01-29 Cont ID  
Sent By adarroug Date 2007-01-29 Time 19:10 Rev Time 0.00
Received By adarroug Date 2007-01-29 Time 19:10 Sent To P
Notes
2007-01-29 19:11:06TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-01-25 Cont ID  
Sent By adarroug Date 2007-01-25 Time 10:17 Rev Time 0.00
Received By adarroug Date 2007-01-25 Time 10:17 Sent To Z
Notes
2007-01-25 10:18:13TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-11-16 Cont ID  
Sent By adarroug Date 2006-11-16 Time 11:37 Rev Time 0.00
Received By adarroug Date 2006-11-16 Time 11:37 Sent To P
Notes
2006-11-16 11:38:04TO "JLEECH" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-11-13 Cont ID  
Sent By adarroug Date 2006-11-13 Time 14:58 Rev Time 0.00
Received By adarroug Date 2006-11-13 Time 14:58 Sent To Z
Notes
2006-11-13 14:58:36TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-23 Cont ID  
Sent By adarroug Date 2006-10-23 Time 11:46 Rev Time 0.00
Received By adarroug Date 2006-10-23 Time 11:46 Sent To B
Notes
2006-10-23 11:46:27TO "MISC' BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-11-02 Cont ID  
Sent By jleech Date 2006-11-02 Time 14:16 Rev Time 0.00
Received By jleech Date 2006-10-12 Time 15:34 Sent To  
Notes
2006-10-12 15:35:08TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-01-30 Cont ID  
Sent By jleech Date 2007-01-30 Time 10:02 Rev Time 0.00
Received By jleech Date 2007-01-30 Time 10:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-11-16 Cont ID  
Sent By jleech Date 2006-11-16 Time 14:12 Rev Time 0.00
Received By jleech Date 2006-11-16 Time 14:12 Sent To B
Notes
2006-11-16 14:38:39DENIED;
  
 1.(SECOND REQUEST) SECONDARY ROOF DRAINS SHALL
 DISCHARGE IN A LOCATION WHICH WOULD NORMALLY BE
 OBSERVED BY THE BUILDING OCCUPANTS
 OR MAINTENANCE PERSONNEL. SEE FBC-2004 PLUMBING
 SECTION 1107.2. (NOT VISIBLE AS DRAWN)
 2. DETAIL "B" ON SHT. A3.0;
 A. SHOW SIZE AND MATERIAL TYPE
 OF PIPE, SECONDARY DRAIN.
 B. SIZE EMERGENCYSCUPPER
 PER TABLE 1106.7 PLBG.
 C. SHOW HIGHT ABOVE ROOF DRAIN
 TO COMPLY WITH FBC-2004 BUILDING
 SECTION 1503.4.3.
 ALL COMMENTS ARE SECOND REQUESTS.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-11-02 Cont ID  
Sent By jleech Date 2006-11-02 Time 14:16 Rev Time 0.00
Received By jleech Date 2006-11-02 Time 13:58 Sent To  
Notes
2006-11-02 14:16:01DENIED;
 NO INFORMATION FOR ROOF DRAINS OR SECONDARY EMERGENCY
 DRAINS SHOWN ON PLANS;
 THE FOLLOWING INFORMATION IS REQUIRED
 SO A PLUMBING PLAN REVIEW CAN BE DONE.
 A) TYPE OF MATERIAL TO BE USED.
 B) LIST DRAINS TO BE USED.
 C) SIZE THE RAIN DRAINS AND LEADERS. SHOW ROOF
 AREA AND PARAPET AREA PER FBC-2004 PLUMBINGCHAPTER
 11.
 D) SHOW CALCULATIONS FOR SECONDARY DRAINS.
 HEIGHT ABOVE ROOF.
 E)SECONDARY DRAINS SHALL TERMINATE IN A
 VISIBLE LOCATION. PLAN SHOW DRAIN ENDS BEFORE THE EDGE
 OF ROOF.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-11-14 Cont ID  
Sent By mflis Date 2006-11-14 Time 11:53 Rev Time 0.00
Received By mflis Date 2006-11-14 Time 11:53 Sent To  
Notes
2006-11-14 14:14:16ROUTED TO INCOMONG FOR FURTHER REVIEW

Review Stop Z ZONING
Rev No 1 Status P Date 2006-11-14 Cont ID  
Sent By mflis Date 2006-10-17 Time 11:32 Rev Time 0.00
Received By mflis Date 2006-10-17 Time 11:30 Sent To  
Notes
2006-10-17 11:33:40REVIEWED - PERIMETER WALL W/ CLAY TILE.
  
 -MJF