| Plan Review Stops For Permit 06100214 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-02-22 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-02-22 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2008-02-22 16:34:39 | THE JOB LOCATION IS AT 3624 GEORGIA AVE , CONVERSATION | | | WITH THE PROJECT ARCHITECT , ANDY SHARE. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-03-21 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-03-21 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2008-03-21 16:44:32 | REVISION FOR BUILDING TYPEOK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-02-22 |
Time |
08:17 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2008-02-22 |
Time |
08:16 |
Sent To |
PC |
|
| Notes |
| 2008-02-22 08:38:08 | BUILDING PLAN REVIEW | | | PERMIT: 06100214 | | | ADD: 3624 GEORGIA AV | | | CONT: INDUSTRIAL COMMERCIAL STRUCTURES, INC | | | TEL: (561)472-0563 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2005 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONREVIEW | | | ACTION: DENIED | | | | | | 1)THERE SEEMS TO BE A QUESTION AS TO THE ADDRESSOF | | | THE TENANT LOCATION, THE PLUMBING INSPECTOR HAS NOTED | | | THIS DURING INSPECTION AS WELL AS THE SUBMITTAL HAVING | | | A DIFFERENT ADDRESS AS OF THE REVISION? 106.1.2. | | | ADDITIONAL INFORMATION REQUIRED. IF A CHANGE OF ADDRESS | | | IS TO BE REQUIRED PLEASE CONTACT LACRAMIOARA (LILLY) | | | URSA AT 822-1239. | | | | | | 2) A-0.0 MINIMUM BUILDING TYPE IS DECLARED AS A TYPE IV | | | (HEAVY TIMBER) WHILE THE NEXT LINE BELOW THE EXTERIOR | | | WALLS ARE CMU. PLEASE PROVIDE THE MINIMUM BUILDING TYPE | | | SEE TABLE | | | 503 & TABLE 601. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-01-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-07 |
Time |
13:51 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2008-01-07 |
Time |
13:51 |
Sent To |
PC |
|
| Notes |
| 2008-01-07 13:54:28 | REVISION# 2 12-31-07 ADD LOW WALL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-06 |
Time |
10:20 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-03-06 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-17 |
Time |
14:28 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2006-11-17 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2006-11-17 15:14:32 | BUILDING PLAN REVIEW | | | PERMIT: 06100214 | | | ADD: 3654 GEORGIA AVE. | | | CONT: INDUSTRIAL COMMERCIAL STRUCTURES | | | TEL: (407)9484395 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 )FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) PLEASE PROVIDE A SITE PLAN PROVIDING THISTENANT | | | LOCATION WITHIN THE BUILDING. | | | 106.1.2* ADDITIONAL INFORMATION REQUIRED. | | | | | | 4) SHEET A-0.0 CODE SUMMARY INDICATES | | | THE PLANS WERE DESIGNED TO THE 2001 | | | FBC. ALL REFRENCES TO CODE SECTIONS ALSO | | | REFLECT THE DESIGN TO THE 2001FBC. | | | OCT. 1, 2005 ALL PERMIT APPLICATIONS SUBMITTED | | | ON THIS OR AFTER ARE TO BE DESIGNED TO THE | | | 2004 FBC, BUILDING & 2004 EXISTING BUILDING CODE. | | | PLEASE CORRECT DESIGN TO THE 2004 FBC AND ALL CODE | | | REFRENCES ARE TO REFLECT THE 2004 FBC. | | | | | | 5) 2004 EXISTING BUILDING CODE PLEASE PROVIDE TO WHAT | | | LEVEL | | | OF ALTERATIONS WILL BE COMPLETED UNDER THIS PERMIT? | | | | | | 6A)SHEET A8.1 SPECIFICATIONS INDICATE THIS DESIGN | | | UNDER | | | THE 2001 FBC, PLEASE CORRECT TO THE 2004 FBCAND THE | | | WRONG ADDITION OF ASCESHOULD READ ASCE 7-02. | | | | | | 6B) THE BUILDING CATEGORY LISTED AS I, THIS WOULD BE | | | FOR | | | FARM OUT BUILDINGS SMALL SHEDS. | | | | | | 6C) PREMANUFACTUREDA/C STANDS REQUIRE, (2) COPIES: | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | PRODUCTS WILL REQUIRE FLORIDA COVERSHEET AND ASSOCIATED | | | REPORT. | | | | | | 6D))W P B ADMINISTRTIVE CODE 106.3.3* | | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 7) PLANS DO NOT PROVIDE A SEATING ARANGEMENT FOR | | | ACCESSIBILITY. | | | PLEASE SHOW COMPLIANCE AND FOR11-5.2 COUNTERS AND | | | BARS. | | | WHERE FOOD OR DRINK IS SERVED AT COUNTERS EXCEEDING 34 | | | | | | INCHES (865 MM) IN HEIGHT FOR CONSUMPTION BY CUSTOMERS | | | SEATED | | | ON STOOLS OR STANDING AT THE COUNTER, A PORTION OF THE | | | MAIN COUNTER | | | WHICH IS 60 INCHES (1525 MM) IN LENGTH MINIMUM SHALL BE | | | PROVIDED | | | IN COMPLIANCE WITH SECTION 11-4.32 OR SERVICE SHALL BE | | | AVAILABLE AT | | | ACCESSIBLE TABLES WITHIN THE SAME AREA. | | | | | | 8) CHANGE OF OCCUPANCY WILL REQUIRE IMPACT FESS REVIEW: | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-04 |
Time |
19:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-04 |
Time |
19:20 |
Sent To |
|
|
| Notes |
| 2008-03-04 19:20:45 | REV #8, E6.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-30 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-30 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2007-12-30 13:48:28 | REV 3.1 AND 6.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-22 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-22 |
Time |
09:15 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-27 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-27 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2007-07-27 14:59:35 | *** UNSAT 4TH REVIEW *** | | | | | | 1) NOTE: PLEASE SEE AS STATED ON PREVIOUS REVIEW, | | | PLEASE CORRELATE THE LIGHTING AND METHODS OF CONTROLS | | | FOR LIGHTING ON THE ENERGY CALCULATIONS WITH PLANS. | | | PLEASE SEE THE PLANS SHOW AUTOMATED CONTROLS FOR ALL | | | LIGHTING, HOWEVER THE INPUT DATA REPORT SHOWS *MANUAL | | | ON/OFF* FOR TWO OF THE FIXTURES FOR BATHROOMS? THIS IS | | | NOT POSSIBLE. | | | PLEASE ALSO SEE THE NEW ENERGY CALCULATIONS SUBMITTED | | | ARE UNDER THE NEW CODE DATED AS OF DECEMBER 8TH, 2006. | | | THIS PROJECT IS UNDER THE PREVIOUS CODE REVISIONS TO | | | THE 2004 FBC WHICH REQUIRES THE RELEVANT ENERGY | | | CALCULATIONS AT THE TIME OF PERMIT APPLICATION. | | | PLEASE SEE THIS WOULD BE VERSION 2.11AS ADOPTED BY THE | | | 2004 FBC W/2005 REVISIONS. | | | PLEASE KNOW THIS WAS CONFIRMED WITH THE STATE AND | | | BUILDING OFFICIAL. MAY NOT SUBMIT ENERGY CALCULATIONS | | | FROM ONE CODE AND PLANS FROM ANOTHER CODE EVEN IF THE | | | NEW ENERGY CODE IS MORE RESTRICTIVE. | | | 13-415.1.A | | | | | | 2) NOTE: PLEASE SEE THE PREVIOUS REVIEW NOTES | | | SPECIFICALLY NOTED FOR ELECTRICAL PLANS TO BE SIGNED BY | | | THE ENGINEER OF RECORD AS ON FILE. PLEASE SEE ONLY THE | | | NEW REVISED SHEET E2.1 CONTAINS THE SIGNATURE AS | | | RECOGNIZED AND AS ON-FILE WITH THE CITY OF WEST PALM | | | BEACH. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-20 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-20 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2007-06-20 12:01:37 | *** UNSAT 3RDREVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED | | | NEED TO COORDINATE WITH THE PLANS FOR THE NUMBER OF | | | FIXTURES, THE WATTAGE FOR FIXTURES. PLEASE SEE THE | | | PLANS DO NOT INDICATE ANY FIXTURE LEGEND FOR THE | | | FIXTURES AND WATTAGE FOR EACH. PLEASE SEE FIXTURES ON | | | ENERGY CALCULATIONS INDICATE COMPACT FLUORESCENT WHICH | | | IS NOT CLEAR WHEN THE MAJORITY OF THE FIXTURES ON PLANS | | | ARE 2X4 LAY-IN FIXTURES. | | | PLEASE PROVIDE INFORMATION FOR THESE FIXTURE TYPES AND | | | BE SURE TO COORDINATE WITH CALCULATIONS. | | | PLEASE BE SURE THE OWNER AGENT IS ISGNED ON SHEETS FOR | | | VERIFICATION.13-103.1, 13-415.1.AB.1.1 | | | | | | 2) NOTE: PLEASE SEE THE VALUE FOR COMPLETE SCOPE OF | | | WORK WAS NOT ADJUSTED BY THE CONTRACTOR. PLEASE SEE FBC | | | 108.3 AS ALL EQUIPMENT, LABOR, MATERIALS, DESIGN COST | | | FOR ARCHITECTURAL AND ENGINEERING ETC. | | | THE VALUE AS SUBMITTED IS TOO LOW AND IF AN APPROPRIATE | | | VALUE IS NOT INDICATE, ONE WILL BE ASSESSED BY GUIDES | | | ADOPTED BY THE FBC. | | | | | | 3) NOTE: PLEASE SEE THE ELECTRICAL PLANS ARE NOT SIGNED | | | WITH SIGNATURE ON FILE AND RECOGNIZED BY THIS OFFICE. | | | FS 471.025 | | | | | | 4) NOTE: PLEASE SEE THAT SETS NEED TO BE SUBMITTED WITH | | | ALL SHEETS ATTACHED INTO SETS FOR REVIEW AND STAMPING | | | AS PREVIOUSLY STATED IN EACH OF THE PREVIOUS REVIEWS. | | | PLEASE DO NOT SUBMIT LOOSE SHEETS. PLEASE BE SURE THESE | | | ARE BOUND IN SOME MANOR. | | | SETS WERE PLACED AND ATTACHED TOGETHER BY THIS REVIEWER | | | HOWEVER WILL NOT BE DONE IF PLANS ARE SUBMITTED THE | | | SAME WAY FOR THE NEXT REVIEW. | | | FBC 106.1 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-04 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-04 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2007-03-04 11:44:50 | ** UNSAT 2ND REVIEW ** | | | | | | ** PLEASE SEE THAT SOME NOTES ARE FROM THE PREVIOUS | | | REVIEW STILL ARE IN NEED OF ADDRESSING. | | | PLEASE SEE THERE ARE MANY NEW NOTES AS SCOPE OF WORK | | | FOR ELECTRICAL HAS COMPLETELY CHANGED. | | | | | | 1) NOTE: PLEASE SEE COMPLIANCE FOR CHAPTER 13 STILL | | | NEEDS TO BE CLARIFIED. PLEASE SEE CALCULATIONS | | | SUBMITTED DO NOT CORRELATE WITH LIGHTING AS SHOWN ON | | | PLANS OR CONTROL FOR SUCH LIGHTING. | | | PLEASE SEE PREVIOUS ENERGY CALCULATIONS SUBMITTED AS | | | ONLY ONE FIXTURE IS BEING SHOWN AND *MANUAL ON/OFF *. | | | PLEASE SEE NO MAXIMUM TIMES ARE SHOWN FOR DEVICES. | | | PLEASE INDICATE MAXIMUM LIGHTING POWER ALLOWANCES. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3. 13-415.2. | | | ETC | | | | | | 2) NOTE: PLEASE SEE NEW SERVICE RISER AND PLEASE | | | CORRELATE ALL EQUIPMENT. SOME SHOWN AS 2400AMPS, | | | 2500AMPS ETC? | | | FBC 106.1.2 ADMIN SECTION. | | | | | | 3) NOTE: PLEASE SEE THE MSBA AND RISER AS SHOWN COULD | | | HAVE POWER FROM BOTH THE UTILITY AND BACK UP POWER | | | SOURCE. | | | PLEASE SEE PLANS NOW INDICATE A NEW SWITCH BOARD | | | OUTSIDE WHICH DOES NOT PROVIDE THE INADVERTENT | | | CONNECTION OF THE EQUIPMENT INSIDE. | | | PLEASE KNOW THAT A KIRK KEY INTERLOCK WILL NOT PROVIDE | | | A *FAIL SAFE/INADVERTENT* OPERATION. THIS OFFICE HAS | | | REVIEWED DOCUMENTATION PROVIDED BY SQ *D* ON OTHER | | | PROJECT(S) WHICH DOES NOT SEEM TO MEET CODE FOR THE | | | INSTALLATION. PLEASE KNOW IT IS THE UNDERSTANDING OF | | | THIS OFFICE THAT SOME EQUIPMENT IS BEING SUBMITTED FOR | | | LISTINGS FOR INTENDED USE OF TRANSFER EQUIPMENT HOWEVER | | | INFORMATION FOR THIS HAS NOT BEEN SUBMITTED AT THIS | | | TIME FOR ALLOWANCE. | | | PLEASE KNOW THAT THERE HAVE BEEN PREVIOUS PROJECTS | | | WHICH MAY HAVE ALLOWED THESE TYPES OF DEVICES HOWEVER | | | THIS WILL NOT BE PERMITTED BY THIS AHJ. PLEASE KNOW | | | THIS AHJ ALONG WITH SEVERAL OTHER LOCAL JURISDICTIONS | | | HAVE SEEN MULTIPLE KEYS ON-SITE WHICH WILL ALLOW BOTH | | | SIDES TO BE CONNECTED. PLEASE KNOW THAT UNTIL PRODUCTS | | | ARE LISTED AND PROVIDE THE OPERATION WHICH PROVIDES THE | | | INADVERTENT CONNECTION FROM THE UTILITY AND THE BACK UP | | | POWER SOURCE THIS IS A LIFE SAFETY AND PROPERTY HAZARD | | | AND WILL NOT BE ACCEPTED BY THIS AHJ. | | | THIS OFFICE HAS NOT MENTIONED THAT A *LISTED TRANSFER | | | SWITCH* IS REQUIRED HOWEVER WE ARE REQUIRING THE DEVICE | | | IS LISTED FOR USE AND THAT IT PROVIDES COMPLETE FAIL | | | SAFE OPERATION. | | | DEVICES AS SUBMITTED DO NOT PROVIDE THIS REQUIREMENT. | | | PLEASE SEE 110.3, 90.7, 702.6 ETC. | | | PLEASE SUBMIT ACTUAL SPEC/MANUFACTURES CUT SHEETS. | | | | | | 4) NOTE: PLEASE SEE TAPPED CONDUCTORS ON GUTTER WOULD | | | BE REQUIRED TO TERMINATE IN OCP PER 240.21. 408.16. | | | PLEASE SEE THAT DISCONNECTS OF SOME KIND ARE BEING | | | SHOWN HOWEVER PLEASE PROVIDE/SHOW THE OVER CURRENT AT | | | EACH OF THESE. | | | | | | 5) NOTE:PLEASE SEE THIS COMMENT FROM THE PREVIOUS | | | REVIEW HAS NOT BEEN ADJUSTED. PLEASE KNOW THAT BASED ON | | | THE ELECTRICAL SCOPE OF WORK ALONG, THE VALUE HAS | | | SUBSTANTIALLY INCREASED AND NO ADJUSTMENTS TO THE | | | PERMIT APPLICATION HAVE BEEN MADE. A VALUE WILL BE | | | REVIEWED AND ADJUSTED BY THIS OFFICE AS NEEDED ON THE | | | NEXT RE-SUBMITTAL. | | | PLEASE SEE VALUE FOR COMPLETE SCOPE OF WORK SHALL | | | INCLUDE ALL LABOR AND MATERIALS, EVEN IF ANY EQUIPMENT | | | IS OWNER SUPPLIED. | | | PLEASE KNOW IF AN APPROPRIATE VALUE IS NOT ADJUSTED, | | | ONE WILL BE ADJUSTED BASED ON MARSHALL'S & SWIFT GUIDE | | | AS ADOPTED INTO THE FBC 108.3 ADMINISTRATIVE SECTION AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 6) NOTE: PLEASE SEE THAT PLANS DO NOT INDICATE DIRECT | | | ACCESS TO THE MAIN ELECTRICAL SWITCHGEAR FOR SHUT DOWN. | | | DOORS, OPENINGS, TRAVEL DISTANCE, ETC. THE LOCATION | | | NEEDS TO BE DETERMINED BY THIS OFFICE AND THE FIRE | | | MARSHAL ONCE SHOWN ON PLANS. | | | PLEASE SEE 230.70. | | | PLEASE ALSO SEE THAT THE LOCATION FOR STORAGE/EASILY | | | IGNITABLE ETC CAN NOT BE VERIFIED AT THIS TIME. | | | PROTECTION OF THIS EQUIPMENT IS REQUIRED IN ANY OPEN | | | AREAS AS THE OTHER EQUIPMENT ON PLANS OUTSIDE IS | | | SHOWN. | | | 110.26, 408.7, 240.24 ETC. | | | | | | 7) NOTE: PLEASE SEE THE NEW SWITCH GEAR SHOWS NEW OVER | | | CURRENT PROTECTION TO ALL EXISTING PANELS; HOWEVER SIZE | | | OF THOSE EXISTING PANELS HAS NOT BEEN SHOWN. | | | PLEASE ALSO SEE PANELS *KB AND KC* WHICH DO NOT SHOW | | | ANY ITEMS ON PANEL SCHEDULES, YET PANELS SHOW LOADS? | | | PLEASE CLARIFY ALL PANELS, USE, LOADS ETC. | | | 215.5, 240, 220, 310.16 ETC | | | | | | FBC 106.3.5.1.2, 106.1.2 ADMIN SECTION FOR INFORMATION | | | NEEDED. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-10-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-28 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-28 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2006-10-28 18:15:35 | **** UNSAT ****** | | | | | | 1) NOTE: PLEASE BE SURE ALL OF THE FOLLOWING CODES ARE | | | STATED ON PLANS. 2002 NFPA-70, 2003 NFPA-101, 2002 | | | NFPA-72, 2004 NFPA-96 ETC. | | | | | | 2) NOTE: PLEASE SEE SPACE APPEARS TO BE PART OF A | | | LARGER BUILDINGAND THE NEW SERVICE BEING REQUESTED IS | | | NOT GRANTED AT THIS TIME. THIS BUILDING ALREADY | | | CONTAINS NUMEROUS MAINS AND SERVICE EQUIPMENT. A | | | SERVICE CHANGE/OVERHAUL WILL BE REQUIRED. AS SHOWN AND | | | GIVEN THE SERVICE ON THE BUILDING THIS DOES NOT MEET | | | 230.2. | | | | | | 3) NOTE: PLEASE SEE PLANS STATE A "TEST" KITCHEN | | | HOWEVER THE SAME REQUIREMENTS FOR ANY COMMERCIAL | | | KITCHEN WILL BE REQUIRED AS THESAME TASKS WILL BE AT | | | HAND. | | | PLEASE SEE 210.8B3 FOR ALL RECEPTS. PLEASE KNOW, EVEN | | | ALL THE EXISTING. | | | | | | 4) NOTE: PLEASE SEE AS THIS APPEARS TO BE A CHANGE IN | | | USE OR OCCUPANCY, PLEASE SEE CHAPTER 13 FOR | | | COMPLIANCE. | | | PLEASE SHOW ALL OTHER AREAS PART OF THIS BUILDING. | | | | | | 5) NOTE: PLEASE SEE ANY POSSIBLE FIRE REVIEW NOTES WITH | | | RESPECT TO AN EXIT LT WHICH APPEARS TO GUIDE PERSON | | | BACK INTO THE LARGER PORTION OF THE BUILDING. THIS IS | | | NOT AN ELECTRICAL REVIEW NOTE , HOWEVER ANY CHANGES MAY | | | AFFECT THE ELECTRICAL PLANS. | | | LS 101 7.8, 7.9 | | | | | | 6) NOTE: PLEASE SEE TAPPED CONDUCTORS ON GUTTER WOULD | | | BE REQUIRED TO TERMINATE IN OCP PER 240.21. | | | 408.16HOWEVER PLEASE KNOW, AT THIS TIME, DUE TO THE | | | UNKNOWN OF THE EXISTING SERVICE, BUILDING ETC, THIS | | | COMMENT HAS NO AFFECT AS THE SERVICE AS SHOWN IS NOT | | | PERMITTED. | | | | | | 7) NOTE: PLEASE SEE VALUE FOR COMPLETE SCOPE OF WORK | | | SHALL INCLUDE ALL LABOUR AND MATERIALS, EVEN IF ANY | | | EQUIPMENT IS OWNER SUPPLIED. | | | PLEASE KNOW IF AN APPROPRIATE VALUE IS NOT ADJUSTED, | | | ONE WILL BE ADJUSTED BASED ON MARSHALL'S & SWIFT GUIDE | | | AS ADOPTED INTOTHE FBC 108.3 ADMINISTRATIVE SECTION | | | AS ADOPTED BY THE CITY OF WESTPALM BEACH. | | | | | | 8) NOTE: PLEASE SEE SOME SHEETS ARE MISSING FROM SETS | | | WHICH ARE INDICATED ON COVER TITLE SHEET. | | | | | | 9) NOTE:** IMPORTANT** | | | ** DO NOT IGNORE THIS COMMENT. | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT THE ELECTRICLA PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-10-22 09:16:29 | SEE UPDATED "I" NOTES, TO BE PLACED ON COMM BOARD. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-19 |
Time |
19:37 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-19 |
Time |
19:24 |
Sent To |
|
|
| Notes |
| 2008-03-19 19:37:21 | *****REVISION #3, DATED 2/22/08, APPROVED***** | | | | | | | | | REVISED PLAN SHEETS A-1.1AND A-1.2 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-01-09 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-09 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2008-01-09 10:43:28 | REVISED SHEETS E3.1, E6.1, M0.1, M2.1, P2.1, P5.1. | | | STAMPED. SIGNED AND DATED E3.1 ON THIS DATE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-29 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-29 |
Time |
11:51 |
Sent To |
M |
|
| Notes |
| 2007-11-29 11:54:51 | *****APPROVED REVISION***** | | | | | | | | | PLAN SHEET 3 OF 3 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-08 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-08 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2007-03-08 10:42:54 | *****APPROVED***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED.PLAN SHEET A-1.0 AND E2.1 WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-13 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-13 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2006-12-13 12:04:04 | *****DENIED***** | | | | | | | | | | | | 1.NFPA 101 (2003 EDITION) AND THE FLORIDA FIRE | | | PREVENTION CODE (2004 EDITION) SHALL BE REFERENCED. | | | AMEND SHEET A 0.0 UNDER BUILDING CODES. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT | | | HINDER OR INTERFERE WITH EMERGENCY ACCESS TO THE SAID | | | PROPERTY OR VICINITY TEREOF. | | | | | | 4.INTERIOR FINISH IN AN UNSPRINKLERED BUILDING SHALL | | | BE CLASS "A" OR CLASS "B" , NO CLASS "C". | | | | | | 5.THERE APPEARS TO BE A DISCREPANCY IN THE SWING OF | | | THE DOUBLE EXIT DOORS.FOR EXAMPLE, SHEET KE-1.0 HAS | | | THE DOORS SWINGING INTO THE EGRESS PATH, WHEREAS SHEET | | | P2.1 HAS THE DOORSPROPERLY SWINGING OUT TOWARDS THE | | | DIRECTION OF EGRESS. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-03-07 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-03-07 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-26 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-26 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2008-02-26 16:25:39 | TO "COMM" BD#19 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-14 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-14 |
Time |
11:50 |
Sent To |
B |
|
| Notes |
| 2008-02-14 11:50:52 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2008-01-02 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2008-01-02 |
Time |
12:25 |
Sent To |
B |
|
| Notes |
| 2008-01-02 12:26:24 | TO JIM WITMERS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-28 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-28 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2007-12-28 11:58:24 | TO COMM BOARD # 42 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-19 |
Time |
16:30 |
Sent To |
M |
|
| Notes |
| 2007-11-19 16:30:49 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-16 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-16 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2007-08-16 10:51:30 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-18 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-18 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2007-07-27 12:04:59 | TO "COMM" BD#60 | | 2007-07-18 16:37:19 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-25 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-25 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2007-06-26 09:50:23 | 6/26/07--TAKEN FROM "COMM" BD AND ROUTED TO "P" | | 2007-06-14 13:43:12 | TO "COMM" BD#4 | | 2007-05-25 09:51:03 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-01 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-01 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2007-03-01 11:27:02 | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-13 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-12 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2006-10-24 15:47:56 | TO "COMM" BD#26 | | 2006-10-22 09:15:41 | REMOVED FROM BOB BOARD, AND PLACED ON TABLE WAITING FOR | | | COMM BOARD. PER RB AND DVP> | | 2006-10-20 13:09:21 | TO "BOB"#6 | | 2006-10-12 10:21:10 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-12-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-31 |
Time |
14:35 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-12-31 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2007-12-31 14:37:21 | REVISION TO MECH. PLANS PAGES M0.1 AND M2.1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-29 |
Time |
14:07 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-29 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2007-11-29 14:08:15 | REVISION TO KITCHEN HOOD PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-02 |
Time |
09:13 |
Rev Time |
2.00 |
| Received By |
tgordon |
Date |
2007-03-02 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2007-03-02 09:19:39 | *** NOTICE *** | | | 1) ADDITIONAL PERMITS REQUIRED FOR HOOD AND FIRE | | | SUPPRESSION (SUBMIT FIRE SUPPRESSION PLANS WITH | | | APPLICATION). |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-26 |
Time |
11:58 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2006-10-26 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2006-10-26 12:08:58 | *** DENIED *** | | | 1) SEE PAGE A-8.1 SPECIF. #10 REFERS TO THE 2001 FBC, | | | PLEASE CORRECT AS THE CURRENT CODE IN USE IS 2004 FBC. | | | | | | 2) PAGE KE-3.0 (CAPTIVE AIR HOOD DRAWING) IS MISSING | | | FROM PLAN SET. PLEASE PROVIDE PLANS FOR KITCHEN HOOD. | | | | | | 3) PLEASE SHOW ON PLANS HOW KITCHEN HOOD EXHAUST FAN & | | | SUPPLY FAN ARE TO BE SECURED TO ROOF TO WITH STAND 140 | | | MPH WIND, PER 2004 FBC 1609. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | | | 2006-10-20 15:31:05 | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2008-03-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-24 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-24 |
Time |
11:04 |
Sent To |
PC |
|
| Notes |
| 2008-03-24 11:06:40 | REVISION:ADDED NEW SHEET NUMBERS A-1.1, AND A-1.2. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-22 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-22 |
Time |
06:33 |
Sent To |
|
|
| Notes |
| 2008-02-22 06:42:07 | REVISION DENIED | | | REFERENCE: FBC-2004 CHAPTER 11 | | | FBC-2004 BUILDING | | | | | | 1. SHT A-1.1 DETAIL 5, THE LAV SHALL BE A MINIMUM 1'3" | | | OFF THE WALL TO THE CENTERLINE OF THE FIXTURE TO BE | | | CENTERED ON THE 30" WIDTH OF THE 30"X48" CLEAR FLOOR | | | SPACE REQUIRED BY SECTION 11-4.19.3. | | | | | | 2. SHT A-1.2 DETAILS 19 & 20, SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | | | | ___FOR W/C: | | | 1. 11-4.16.3 HEIGHT | | | | | | ___ FOR LAV: | | | 1. 11-4.19.3 HEIGHT | | | | | | | | | 3. SHT A-1.2 DETAILS 19 & 20 PER SECTION 1210.2 WALLS | | | WITHIN 2 FEET OF WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE. EPOXY PAINT DOES NOT COMPLY | | | WITH THE REQUIREMENT FOR A HARD SURFACE. PLEASE SHOW | | | COMPLIANCE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-01-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-01-23 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-01-23 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2008-01-23 16:36:12 | REVISION OK - SHTS P2.1 & P5.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-08-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-11 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-11 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-07-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-07 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-07 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2007-07-07 17:43:35 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHEETS P0.1 & P5.1. A PROFESSIONAL ENGINEER SHALL | | | SIGN HIS NAMEWITH A LEGAL SIGNATURE ON FILE IN THIS | | | OFFICE. INITIALS ARE NOT ACCEPTABLE. FAC | | | 61G15-23.002(1)(2) & FS 471.025. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-03-07 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-03-07 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2007-03-07 14:29:13 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE WPB | | | | | | | | | 1. OK | | | | | | 2. ALL ARCHITECTURAL SHEETS. THE EMBOSSED SEAL SHALL | | | IMPART ALL REQUIRED INFORMATION ON EACH SHEET. PLEASE | | | IMPRESS ALL INFORMATION REQUIRED BY FAC 61G1-16.002(1) | | | & FS 481.2055. | | | ****RESPONSE NOTED, BUT ALL THE INFORMATION REQUIRED IS | | | NOT IMPRESSED ON EACH SHEET. THE SEAL APPEARS TO BE | | | WORN OUT, AND MAYBE A NEW SEAL IS NEEDED. | | | | | | 3. OK | | | 4. OK | | | 5. OK | | | | | | 6. A GREASE INTERCEPTOR MAY BE REQUIRED. PLEASE CONTACT | | | LMASSON, ENVIRONMENTAL COMPLIANCE MANAGER, (561) | | | 822-2271, FAX (561) 822-2279, E-MAIL [email protected]. | | | UTILITY ORD. 3434. | | | ****RESPONSE NOTED, BUT NO REPLY FROM ENVIRONMENTAL | | | COMPLIANCE AT THIS TIME. I WILL TRY TO GET THE FINAL | | | DETERMINATION. | | | | | | 7. OK (DEPT. OF AGRICULTURE) | | | 8. OK | | | 9. OK (DELETED) | | | 10. OK | | | 11. OK | | | | | | 12. SHTS P2.1 AND P5.1 THE UNDERCOUNTER GREASE TRAP IS | | | NOT APPROVED. A MINIMUM 750 GALLON GREASE INTERCEPTOR | | | IS REQUIRED PER SECTION 90-124(7)(F) OF THE MUNICIPAL | | | CODE AND THE UTILITY DEPT STANDARD GREASE INTERCEPTOR | | | DETAIL. | | | ****RESPONSE NOTED. WAITING FOR RESPONSE FROM | | | ENVIRONMENTAL COMPLIANCE. | | | | | | 13. OK | | | | | | A. OK | | | B. OK | | | C. OK | | | D. OK | | | E. OK | | | F. OK | | | G. OK | | | H. N/A | | | I. N/A | | | J. OK | | | | | | **********NEW COMMENT********** | | | | | | 1B. SHT P5.1 WATER ISOMETRIC, THE WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURES, IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING AS SHOWN. PDI-WH | | | 201 AND MANUF. INSTALLATION INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-12-06 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-12-06 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2006-12-06 17:42:18 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE WPB | | | | | | | | | 1. ALL ARCHITECTURAL SHEETS. THE BUSINESS NUMBER IS | | | REQUIRED IN THE TITLE BLOCK. FAC 61G1-16.004(2) & FS | | | 481.219. PLEASE PROVIDE REQUIRED INFORMATION ON EACH | | | SEET. | | | | | | 2. ALL ARCHITECTURAL SHEETS. THE EMBOSSED SEAL SHALL | | | IMPART ALL REQUIRED INFORMATION ON EACH SHEET. PLEASE | | | IMPRESS ALL INFORMATION REQUIRED BY FAC 61G1-16.002(1) | | | & FS 481.2055. | | | | | | 3. SHT A-0.0 CODES IN EFFECT ARE FBC-2004. PLEASE | | | DESIGN TO THIS CODE AND CHANGE CODE REFERENCES TO | | | REFLECT THIS REQUIREMENT. | | | | | | 4. PLEASE INDICATE THE SPACE NUMBER ON THE APPLICATION | | | AND ON THE PLANS. THE PLANS INDICATE THAT THIS IS A | | | SPACE WITHIN THE BUILDING. SECTION 106.1.2. | | | | | | 5. SHT A-0.1 PER TABLE 403.1 A DRINKING FOUNTAIN AND A | | | SERVICE SINK ARE REQUIRED. PLEASE INDICATE THE LOCATION | | | OF EACH. | | | | | | 6. A GREASE INTERCEPTOR MAY BE REQUIRED. PLEASE CONTACT | | | LMASSON, ENVIRONMENTAL COMPLIANCE MANAGER, (561) | | | 822-2271, FAX (561) 822-2279, E-MAIL [email protected]. | | | UTILITY ORD. 3434. | | | | | | 7. MORE INFORMATION IS REQUIRED. WILL THERE BE SALES OF | | | FOOD AND WILL THIS BE CONSIDERED A RESTURANT? IF SO THE | | | PLANS WILL HAVE TO BE ROUTED TO DBPR HOTEL & RESTURANT | | | DIVISION FOR REVIEW, AND A MINIMUM OF TWO SETS OF | | | STAMPED PLANS WITH THE TWO PAGE "WORKSHEETS" WILL BE | | | REQUIRED TO BE SUBMITTED TO WEST PALM BEACH FOR REVIEW | | | PRIOR TO ISSUING A PERMIT. SECTION 102.2.1. | | | | | | 8. SHT KE-2.1 DETAIL 15 INDICATES PLUMBING EQUIPMENT | | | SCHEDULE. DETAIL 5 DOES NOT REFLECT THE ITEM NUMBERS. | | | PLEASE CORRELATE SCHEDULE AND ITEM NUMBERS ON THE FLOOR | | | PLAN. SECTION 106.1.1. | | | | | | 9. SHT KE-2.1 DETAIL 15, ITEM 34 INDICATES A WATER | | | FILTER. THE FILTER SHALL COMPLY WITH NSF-42. PLEASE | | | SUBMIT MANUF. SPECIFICATIONS FOR THE FILTER SHOWING | | | COMPLIANCE WITH THE NSF STANDARD. SECTION 611.1. | | | | | | 10. SHT P.1 WATER SERVICE. AN RPZV BACKFLOW IS REQUIRED | | | ON THE WATER SERVICE TO THE SPACE. SECTION 608.13.2. | | | PLEASE INDICATE ON THE RISER DIAGRAM AND ON THE FLOOR | | | PLAN. | | | | | | 11. THERMAL EXPANSION CONTROL IS REQUIRED. PLEASE | | | INDICATE HOW THIS WILL BE ACCOMPLISHED. SECTION | | | 607.3.2. | | | | | | 12. SHTS P2.1 AND P5.1 THE UNDERCOUNTER GREASE TRAP IS | | | NOT APPROVED. A MINIMUM 750 GALLON GREASE INTERCEPTOR | | | IS REQUIRED PER SECTION 90-124(7)(F) OF THE MUNICIPAL | | | CODE AND THE UTILITY DEPT STANDARD GREASE INTERCEPTOR | | | DETAIL. | | | | | | 13. THE FOLLOWING INFORMATION IS REQUIRED FOR THE | | | SEPARATE GAS PERMIT: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. - NO CORRESPONDING LENGTHS SHOWN. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). - THIS WILL BE VERIFIED | | | WHEN ALL LENGTHS OF PIPE ARE SHOWN ON THE RISER | | | DIAGRAM. | | | | | | E. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. - INDICATE IF WATER HEATER ROOM | | | IS A CONFINED SPACE OR NOT. SHOW CUBIC FEET OF HEATER | | | ROOM. | | | | | | F. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. SHOW THE MODEL NUMBER | | | AND BTU LOAD FOR EACH PIECE OF EQUIPMENT TO REFLECT THE | | | GAS RISER DIAGRAM. | | | | | | H. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | I. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | J. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-08 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-08 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2008-01-08 10:38:55 | *ZONING REVIEW NOT REQUIRED - INTERIOR WORK ONLY, AND | | | THE VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|