| Plan Review Stops For Permit 06100197 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-10-20 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-10-20 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-10-20 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2006-10-20 10:28:18 | THE SITE ADDRESS HAS BEEN CHNAGED FROM 6425 S FALGLER | | | DR TO 108 CORTEZ RD |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-10-20 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-10-20 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-10-20 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2007-10-20 11:48:55 | SAME COMMENTS AS THE LAST TWO REVIEWS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-08-27 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-08-24 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2007-08-27 08:36:27 | SAME COMMENTS AS REVIEW DATED APRIL 9TH 2007 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-09 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-09 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2007-04-09 18:27:19 | | | | BUILDING REVIEW COMMENTS | | | | | | | | | | | | PALM BEACH COUNTY IMPACT FEES ARE DUE, PROVIDE RECEIPT | | | AND TWO COPIES OF APPROVED PLANS. | | | | | | A RECORDED NOTICE OF COMMENCEMENT IS ALSO REQUIRED | | | BEFORE FIRST INSPECTION. | | | | | | | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 805-6710 | | 2007-03-20 18:57:31 | NEW SHEETS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-01-15 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2007-01-15 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2007-01-15 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-23 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-23 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2006-10-23 09:19:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY | | | SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | | THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT | | | COMMENCED WITHIN 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED ON ICC BUILDING VALUATION DATA THE PERMIT | | | VALUE HAS BEEN REVISED TO $490,776.ADDITIONAL PERMIT | | | FEES ARE DUE. | | | | | | 4."R" VALUES ON PLANS DO NOT MATCH ENERGY CALCS. | | | | | | 5.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. | | | | | | | | | 6.SUBMIT TWO SETS OF TRUSS DRAWINGS WITH ENGINEERS | | | SEALS SHOWN AS LICENSED NOT CERTIFICATE.FAC 61 | | | G1-16.001 | | | | | | 7.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | | OF 6 INCHESWITHIN THE FIRST 10 FEET. | | | | | | 8.PROPERTY IS IN FLOOD ZONE "A" .BUILDING AND | | | EQUIPMENT SLABS SHALL BE A MINIMUM OF 6" ABOVE THE BASE | | | FLOOD ELEVATION OF 7 FT. NGVD.SHOW ON PLANS. | | | | | | 9.SEPERATE PERMIT REQIRED FOR POOL, FENCE AND | | | ROOFING. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6672 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-17 |
Time |
19:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-17 |
Time |
19:16 |
Sent To |
M |
|
| Notes |
| 2007-07-17 19:36:36 | REDLINED: | | | | | | VIF THE CLEARANCES FOR SERVICE. 110.26 | | | AHU #3 SHOWS 10KW AND 5KW, ALL EQUIPMENT AND OTHER | | | INFORMATION POINTS TO THIS AS A 5KW UNIT. MAY BE | | | MISPRINT. | | | | | | ** PLANS DO NOT NEED TO BE REVISED, STAMPED OK FOR | | | PERMIT ISSUANCE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-20 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-20 |
Time |
18:44 |
Sent To |
M |
|
| Notes |
| 2007-03-20 19:40:52 | ** UNSAT 3RD REVIEW ** | | | | | | 1) NOTE: PLEASE SEE THE FOLLOWING MINIMUM CODES ARE | | | STILL MISSING FROM BEING STATED AND SHOWN ON PLANS. | | | PLEASE SEE THAT THE FOLLOWING ARE LISTED. | | | 2004 FBC | | | 2002 NFPA-70 (NEC). | | | 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE THAT THE PLANS DO NOT CONTAIN A | | | SIGNATURE AND PRINTED NAME OF THE PERSON RESPONSIBLE | | | FOR PLANS AND DESIGN. | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE SEE THE MASTER BATHROOM WEST WALL SINK | | | AREA WHICH REQUIRES A GFI WITHIN 3FT OF THE SINKS EDGE. | | | THE GFI SHOWN BASED ON THE 3/16 SCALE ON PLANS DOES NOT | | | MEET THE WITHIN 3FT. | | | 210.52D. | | | | | | 4) NOTE: PLEASE SEE THE GROUNDING ELECTRODE TO THE LEFT | | | OF THE RISER CONTAINS A #3 FOR THE GEC. THE OTHERS WERE | | | CHANGED TO THE 1/0. | | | | | | 5) NOTE: PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS | | | FROM THE METER TO THE 200AMP MAIN2OF 2 ARE NOT LARGE | | | ENOUGH. PLEASE SEE RISER SHOWS 1/0'S AND THE MINIMUM | | | MUST BE 2/0'S PER 310.15B6 | | | THIS WAS SHOWN THE SAME ON THE PREVIOUS PLANS, HOWEVER | | | WAS MISSED. PLEASE SEE THE 2/0'S SHOWN AFTER THE MAIN | | | ARE OK. | | | | | | 6) NOTE: PLEASE SEE THE CONDUIT SIZES BASED ON THE SCH | | | 80 AND BEING SHOWN AS 1 1/2 INCH IS NOT LARGE ENOUGH | | | FOR THE 3-2/0'S AND THE #6.MUST BE 2INCH MINIMUM. | | | THIS WAS SHOWN THIS WAY ON PREVIOUS RISER, HOWEVER WAS | | | NOT COMMENTED ON BY THIS REVIEWER. | | | | | | 7) NOTE: PLEASE SEE SHEET A-17 WAS NOT SEALED BY THE | | | ENGINEER WHICH IS SIGNED AND DATED ON PLANS AND SHEET | | | ALSO CONTAINS A TITLE BLOCK FOR SAID SHEETS. PLEASE SEE | | | FS 471.025, FAC 61G15-23.002 | | | THIS SHEET WAS VOIDED EVEN THOUGH THIS WAS STAMPED. | | | | | | ** PLANS ROUTED BACK TO MECHANICAL AS M SHEETS DO NOT | | | CONTAIN PRINTED NAME AND SIGNATURE FROM ANY RESPONSIBLE | | | DESIGNER. | | | | | | ** PLEASE ONLY VERIFY THE SPACE ON THE WALL BY THE | | | GARAGE WHICH INDICATES A 400AMP METER AND TWO 200AMP | | | DISCONNECTS IN A SPACE NOTE ON PLANS AS 4FT, 2INCHES? | | | THIS DOES NOT SEEM TO BE ENOUGH SPACE BASED ON THE | | | PLANS AND DIMENSIONS SHOWN WITH THE A/C EQUIPMENT AS | | | SHOWN. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-03-20 18:45:17 | ZONING COMPLETED 3/16, RECEIVED FROM INCOMING ON 3/20 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-12-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-10 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-10 |
Time |
09:37 |
Sent To |
M |
|
| Notes |
| 2006-12-10 10:27:27 | ***** UNSAT 2ND REVIEW **** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW WHICH ARE | | | STILL IN NEED OF ADDRESSING. PLEASE SEE NOTES ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW WITH A "OK" OR "NO" AT | | | THE SAME NUMERICAL NOTE. PLEASE SEE SOME MAY BE NOTED | | | AS "NO/OK", WHICH MEANS PART OF THE NOTE MAY HAVE BEEN | | | ADDRESSED. | | | | | | 1) NOTE: OK. LV SECURITY UNDER SEPARATE PERMIT ALONG | | | WITH POOL.PLEASE KNOW POOL WILL BE UNDER THE 2005 | | | NEC. (PLEASE SEE GROUNDING CHANGES). | | | | | | 2) NOTE: NO, COULD NOT LOCATE THESE NOTED ON PLANS. | | | PLEASE KNOW AS THE CODE HAS CHANGED IT IS IMPORTANT THE | | | RELEVANT CODES ARE SHOWN AS NOT TO FALL UNDER NEW CODE | | | OF 2005 NEC AND THE REVISIONS TO THE 2004 FBC. (REV | | | #6). | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THAT THE FOLLOWING MINIMUM CODES ARE | | | REQUIRED ON PLANS. 2002 NFPA-70, 2002 NFPA-72. | | | | | | 3) NOTE: OK. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE: NO, PLEASE SEE ? BATH WHICH DOES NOT INDICATE | | | ANY GFI AS REQUIRED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE NUMEROUS LOCATIONS ARE MISSING THE REQUIRED | | | GFI RECEPT WITHIN 3' OF LAV/SINKS EDGE IN BATHRMS. | | | 250.52D, 210.8A1 | | | | | | 9) NOTE: NO, PLEASE SEE STUDY AND LAUNDRY ROOMS WITH | | | RECEPTS WITHIN 6' OF SINKS AND NOTE #8 ABOVE. REDLINED | | | ONCE AGAIN. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MANY LOCATIONS ARE MISSING THE GFI | | | DESIGNATIONS AS REQUIRED PER 210.8A1,A2, A3, A7< PLEASE | | | SEE MANY OF THESE HAVE BEEN REDLINED, HOWEVER IT IS IN | | | NO WAY ALL WHICH ARE MISSING THIS DESIGNATION. | | | | | | 10) NOTE: OK. | | | | | | 11) NOTE: OK. | | | | | | 12) NOTE: OK. | | | | | | 13) NOTE: OK. | | | | | | 14) NOTE: OK. | | | | | | 15) NOTE:NO, PLEASE SEE NO RATINGS SHOWN. THE LETTER | | | FROM FPL DOES NOT GIVE THE RATINGS TO BE INSTALLED ONLY | | | WHAT IS AVAILABLE AT THE POLE/TRANSFORMER. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE AIC RATINGS FOR ALL SERVICE EQUIPMENT | | | AND SERIES RATINGS SHALL BE COORDINATED BY THE | | | DESIGNERS. PLEASE SUBMIT. 110.9, 240.12 | | | | | | 16) NOTE: OK. | | | | | | 17) NOTE: OK/NO, PLEASE SEE THREE CIRCUITS ARE SHOWN | | | HOWEVER THEY ARE ALL SHOWN FOR BEDROOM #2. | | | PLEASE ADJUST FOR OTHER CIRCUITS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE LIST ALL THE REQUIRED ARC FAULT PROTECTED | | | CIRCUITS ON PANEL SCHEDULE(S) TO BE PROVIDED. | | | PLEASE SEE 210.12, 408.4, | | | * IT IS KNOWN THAT A NOTE IS ON PLANS, HOWEVER IT IS | | | REQUIRED TO SHOW THE SPECIFIC BRANCH CIRCUITS AT THIS | | | TIME. | | | FBC 106.1.2 ADM IN SECT | | | | | | 18) NOTE: OK. | | | | | | 19) NOTE: OK, AS ONLY NOTED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | *** IMPORTANT ** PLEASE SEE POSSIBLE MECHANICAL NOTES | | | FOR THE LOCATION OF THE ATTIC ACCESS TO THE MECHANICAL | | | EQUIPMENT. PLEASE KNOW, IT SEEMS THE EQUIPMENT IS | | | FARTHER THAN SIX FT FROM ACCESS. PLEASE SEE MECH REVIEW | | | COMMENTS, AS THIS WILL CLEARLY AFFECT THE ELECTRICAL | | | PLANS. | | | | | | 20) NOTE:OK. | | | | | | 21) NOTE: NO, PLEASE SEE 424.3B FOR MINIMUM OCP FOR | | | 10KW UNITS. | | | REDLINED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 424.3B AS THE MINIMUM OCP FOR THE AHU'S | | | SHALL BE DONE AT 125% (MIN). PLEASE ADJUST ANY | | | CONDUCTOR SIZES IF NEEDED. | | | | | | 22) NOTE: OK. | | | | | | 23) NOTE: NO, SAME NOTE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 220.3B4. PLEASE SHOW ALL RECESSED LTS BASED | | | ON MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT BE FIGURED | | | IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON LEGEND FOR | | | FIXTURES BEING USED. | | | | | | 24) NOTE: NO. THE FIXTURE TYPE AS SHOWN DOES NOT MEET | | | FBC 13-606.1.ABC.1.2.4 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE THE FIXTURE TYPE FOR RECESSED LIGHTING | | | PER CHAPTER 13 OF THE 2004 FBC FOR AIR TIGHT CANS ETC. | | | | | | 25) NOTE: OK. | | | | | | 26) NOTE: OK. | | | | | | 27) NOTE: OK, HOWEVER SAME NOTE ONLY BEING NOTED, AS | | | THE SERVICE IS STILL BEING SHOWN AS OVER HEAD. PLEASE | | | KNOW, BASED ON THE FPL TRANSFORMER LOCATION AND THE | | | FUTURE PROPOSED POOL AS SHOWN ON PLANS, THIS MAY BECOME | | | AN ISSUE AT A FUTURE TIME | | | | | | ** PREVIOUS REVIEW NOTE** | | | ** FOR FUTURE REFERENCE, WHEN APPLYING FOR POOL PERMIT, | | | PLEASE SEE 680.8 FOR ANY OVER HEAD CONDUCTOR CLEARANCES | | | AS THE SERVICE ON RISER SHOWS THE SEC'S AS OH. | | | | | | 28) NOTE: OK. | | | | | | 29) NOTE: OK. | | | | | | 30) NOTE:NO/OK, PLEASE SEE PLANS DO NOT CONTAIN THE | | | REQUIRED SIGNATURE OF PERSON RESPONSIBLE FOR PLANS | | | DESIGN. | | | FBC ADMIN SECTION 106.1.2 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FS 481.223 FOR REQUIREMENTS OF WHO IS AND IS | | | NOT PERMITTED TO OFFER ARCHITECTURAL SERVICES AND | | | PROVIDING SIGNED AND SEALED DOCUMENTS.PLEASE BE SURE | | | THE ENGINEER OF RECORD AS SIGNING AND SEALING SAID | | | DOCUMENT IS AWARE OF THIS AND FS 471.025. IF THERE ARE | | | ANY QUESTIONS, ON THIS PLEASE CONTACT THE STATE'S LEGAL | | | COUNSEL TO THE BOARD OF ARCHITECT'S. | | | ** PLEASE KNOW ONE SET OF ELECTRICAL PLANS ARE BEING | | | RETAINED BY THIS OFFICE AT THIS TIME. | | | | | | ** NEW NOTE ** | | | | | | 1) NOTE: PLEASE SEE FLORIDA STATUTES 553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS. PLEASE KNOW THIS IS ONLY A | | | NOTICE GIVEN AT THIS TIME. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-14 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-13 |
Time |
20:03 |
Sent To |
Z |
|
| Notes |
| 2006-10-14 13:16:00 | ***** UNSAT **** | | | | | | 1) NOTE: PLEASESEE NOTES FROM ZONING AND BUILDING | | | REVIEW AS THE POOL AND WALL WILL NOT PART OF THIS | | | PERMIT AND WILL REQUIRE SEPARATE PERMIT APPLICATION FOR | | | EACH ALONG WITH PLANS ETC. ANY WALL DETAILS ETC WOULD | | | BE IN THESE PLANS. | | | PLEASE KNOW, BESIDES THE SEPARATE ELECTRICAL PERMIT, | | | SEPARATE PERMITS FOR LV PHONE/CATV /SPKRS ETC ARE | | | SEPARATE. THESE MAY REFERENCE THESE PLANS AS TURN | | | AROUND PERMIT HOWEVER WILL REQUIRE FEE BASED ON LV | | | SCOPE OF WORK VALUE. | | | ** PLEASE KNOW THE LV SECURITY PERMIT IS SEPARATE FROM | | | ALL OF THE ABOVE AS THEY ARE REPORTED TO THE POLICE | | | DEPT SEPARATELY. | | | | | | 2) NOTE: PLEASE SEE THAT THE FOLLOWING MINIMUM CODES | | | ARE REQUIRED ON PLANS. 2002 NFPA-70, 2002 NFPA-72. | | | | | | 3) NOTE: PLEASE SEE SEC'S TO THE 200A MAIN 1OF 2 IS | | | REQUIRED TO BE SIZED PER 310.16. (31.15B6DOES NOT | | | APPLY) | | | | | | 4) NOTE: PLEASE SEE MAIN PANEL 2OF 2 SHOWS A 200A PANEL | | | SCHEDULE YET RISER SHOWS 100A'S WITH A LOAD EXCEEDING | | | THE RATING OF THE 100A MAIN DISCONNECT. | | | PLEASE ADJUST. | | | 230.70, 240, 240.4, 310.16 ETC. | | | | | | 5) NOTE: PLEASE SEE PLANS DO NOT SHOW LOCATION OF THE | | | MAINS. ONLY SHOWS THE LOCATIONS OF METER AND EACH | | | PANEL. PLEASE SHOW AND PLEASE SEE 230.70, 230.72 FOR | | | GROUPING OF MAINS REQUIRED. | | | | | | 6) NOTE: PLEASE SEE GEC IS NOT LARGE ENOUGH. PLEASE SEE | | | TABLE IN 250.66 AS #3 IS NOT ON TABLE AND #3 IS NOT | | | LARGE ENOUGH. PLEASE KNOW, AS BASED ON THE MIN SEC'S | | | WHICH WILL BE REQUIRED AS THE MAINS AS SHOWN WILL BE | | | CHANGING, PLEASE SEE 250.66 1/0 AWG MIN. | | | | | | 7) NOTE: PLEASE SEE BASED ON PREVIOUS NOTES AND LOADS | | | SHOWN, IF INDEED SERVICE IS GOING CONTAIN A 400A METER | | | AND 2-200A DISCONNECTS, PLEASE SEE 310.15B6 MAY BE USED | | | TO PROVIDE MIN SEC'S ON RISER ONL. | | | | | | 8) NOTE: PLEASE SEE NUMEROUS LOCATIONS ARE MISSING THE | | | REQUIRED GFI RECEPT WITHIN 3' OF LAV/SINKS EDGE IN | | | BATHRMS. 250.52D, 210.8A1 | | | | | | 9) NOTE: PLEASE SEE MANY LOCATION ARE MISSING THE GFI | | | DESIGNATIONS AS REQUIRED PER 210.8A1, A2, A3.A7 < | | | PLEASE SEE MANY OF THESE HAVE BEEN REDLINED, HOWEVER IT | | | IS IN NO WAY ALL WHICH ARE MISSING THIS DESIGNATION. | | | | | | 10) NOTE: PLEASE SEE 210.8A6 AS ALL RECEPTS SERVING | | | KITCHEN COUNTER SPACE ARE REQUIRED TO BE GFI/GFI | | | PROTECTED. | | | | | | 11) NOTE: PLEASE SEE MISSING SMOKE ALARM AT FOYER/AREA | | | LEADING TO FLR ABOVE. PLEASE KNOW THE LOCATION ATTHE | | | TOP OF THE STAIRS IS ALSO REQUIRED. PLEASE KNOW EVEN IF | | | THIS UNIT HAS TO BE WALL MOUNTED, IT MUST BE IN CLOSE | | | PROXIMITY OF THE STAIRS LEADING TO THE FLOOR ABOVE. | | | NFPA-72 11.5.1.1, | | | | | | 12) NOTE: PLEASE SEE NFPA-72 AS ALL SA'S ARE REQUIRED | | | TO BE LOCATED WITHIN 12' OF THE HIGHEST POINT OF ANY | | | GIVEN ROOM'S FLAT CEILING. PLEASE SEE ANY AREAS WITH | | | TRAY CEILINGS WHICH ARE 12" OR MORE WILL REQUIRE THE SA | | | TO BE MOVED. PLEASE ALSO KNOW 3' W/IN THE PEAKS OF | | | SLOPED CEILING, NONE NOTED AT THIS TIME. PLEASE SEE | | | 11.8.3 | | | | | | 13) NOTE: PLEASE VERIFY AND INDICATE OF THESE ARE | | | INDEED GOING TO BE SMOKE DETECTORS ORSMOKE ALARMS? | | | PLEASESEE NFPA-72 FOR DEFINITIONS. IF INDEED SA'S, | | | PLEASE ADJUST DESIGNATIONS. | | | | | | 14) NOTE: PLEASE PROVIDE INFORMATION FOR ELEVATOR AND | | | POWER REQUIREMENTS ETC. PLEASE SEE NO INFORMATION | | | /LOADS ETC ARE SHOWN ON PANEL SCHEDULE/LOAD CALCS. FBC | | | 106.1.2, NEC 2002. | | | UNABLE TO VERIFY CODE COMPLIANCE FOR THIS AT THIS TIME | | | AS ONLY A RECEPT IS BEING SHOWN. | | | | | | 15) NOTE: PLEASE PROVIDE AIC RATINGS FOR ALL SERVICE | | | EQUIPMENT AND SERIES RATINGS SHALL BE CO-ORDINATED BY | | | THE DESIGNERS. PLEASE SUBMIT . 110.9, 240.12 | | | | | | 16) NOTE: PLEASE SEE 210.52E AS A WP LOCATION IS BEING | | | SHOWN AT REAR OF DWELLING HOWEVERNORECEPT OR GFI? | | | 210.8A3 | | | | | | 17) NOTE; PLEASE LIST ALL THE REQUIRED ARC FAULT | | | PROTECTED CIRCUITS ON PANEL SCHEDULE(S) TO BE | | | PROVIDED. | | | PLEASE SEE 210.12, 408.4, | | | * IT IS KNOWN THAT A NOTE IS ON PLANS, HOWEVER IT IS | | | REQUIRED TO SHOW THE SPECIFIC BRANCH CIRCUITS AT THIS | | | TIME. | | | FBC 106.1.2 ADM IN SECT | | | | | | 18) NOTE: PLEASE SEE MISSING RECEPT /LT PER 210.63, | | | 210.70 FOR ATTIC EQUIPMENT. | | | | | | 19) NOTE:*** IMPORTANT ** PLEASE SEE POSSIBLE | | | MECHANICAL NOTES FOR THE LOCATION OF THE ATTIC ACCESS | | | TO THE MECHANICAL EQUIPMENT. PLEASE KNOW, IT SEEMS THE | | | EQUIPMENT IS FARTHER THAN SIX FT FROM ACCESS. PLEASE | | | SEE MECH REVIEW COMMENTS, AS THIS WILL CLEARLY AFFECT | | | THE ELECTRICAL PLANS. | | | | | | 20) NOTE:PLEASE CORRELATE ALL MECHANICAL EQUIPMENT | | | WITH THE ELECTRICAL PLANS AS THE LOADS SHOWN ARE NOT | | | THE SAME. | | | FBC 106.1.2. PLEASE ALSO SEE NEXT COMMENT. | | | | | | 21) NOTE: PLEASE SEE 424.3B AS THE MINIMUM OCP FOR THE | | | AHU'S SHALL BE DONE AT 125% (MIN). PLEASE ADJUST ANY | | | CONDUCTOR SIZES IF NEEDED. | | | | | | 22) NOTE; PLEASE SEE BRANCH CIRCUIT CONDUCTOR FOR OVEN | | | SHOWS 20A BRLR WITH #8?? PLEASE KNOW THIS CONDUCTOR | | | WILL NOT FIT UNDER THE 20A BRKR SCREW/LUG/PLATE. IF THE | | | WIRING IS GOING TO BE #8'S PLACE FOR POSSIBLE FUTURE | | | ELECTRICAL RANGE/OVEN PLEASE NOTE. | | | 110.3, | | | | | | 23 )NOTE: PLEASE SEE 220.3B4. PLEASE SHOW ALL RECESSED | | | LTS BASED ON MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON LEGEND FOR | | | FIXTURES BEING USED. | | | | | | 24) NOTE: PLEASE INDICATE THE FIXTURE TYPE FOR RECESSED | | | LIGHTINGPER CHAPTER 13 OF THE 2004 FBC FOR AIR TIGHT | | | CANS ETC. | | | | | | 25) NOTE:PLEASE SEE MISSING WATER HEATER DISCONNECT | | | PER 422.31, AS A RECEPT IS NOW BEING SHOWN WHICH IS NOT | | | PERMITTED. | | | PLEASE SHOW DISCONNECT. | | | | | | 26) NOTE: PLEASE BE SURE A GFI RECEPT LOCATION IN TH | | | REAR OF THE DWELLING IS WITHIN 20' OF POOL AND AT LEAST | | | 10FT. PLEASE SEE 210.8, 680.22 | | | | | | 27) NOTE:: ** FOR FUTURE REFERENCE, WHEN APPLYING FOR | | | POOL PERMIT , PLEASE SEE 680.8 FOR ANY OVER HEAD | | | CONDUCTOR CLEARENCES AS THE SERVICE ON RISER SHOWS THE | | | SEC'S AS OH. | | | | | | 28) NOTE: PLEASE SEE "ENHANCED" GROUNDING ELECTRODE | | | SYSTEM GROUNDING DETAIL SHOULD REFLECT THE INCREASED | | | GEC AS REQUIRED PER NOTES ABOVE 250.66. | | | 250.50. | | | | | | 29) NOTE: PLEASE SEE SOME BATH RM RECEPTS ARE BEING | | | SHOW WITH A SYMBOL WHICH INDICATE THE DEVICE AT | | | 220V'S?? | | | PLEASE SEE PREVIOUS NOTE WITH RESPECT TO ALL BATH RMS. | | | 210.8A1, 210.52D. | | | | | | 30) NOTE: PLEASE SEE FS 481.223 FOR REQUIREMENTS OF WHO | | | IS AND IS NOT PERMITTED TO OFFER ARCHITECTURAL SERVICES | | | AND PROVIDING SIGNED AND SEALED DOCUMENTS.PLEASE BE | | | SURE THE ENGINEER OF RECORD AS SIGNING AND SEALING SAID | | | DOCUMENT IS AWARE OF THIS AND FS 471.025. IF THERE ARE | | | ANY QUESTIONS, ON THE THIS PLEASE CONTACT THE STATE'S | | | LEGAL COUNSEL TO THE BOARD OF ARCHITECT'S. | | | ** PLEASE KNOW ONE SET OF ELECTRICAL PLANS ARE BEING | | | RETAINED BY THIS OFFICE AT THIS TIME. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2006-10-13 20:32:38 | PLANS WILL BE PLACED INTO A "F" STATUS AND REVIEW NOTES | | | ADDED ONCE COMPLETED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-08 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-08 |
Time |
12:40 |
Sent To |
M |
|
| Notes |
| 2008-09-08 12:40:47 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-05 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-05 |
Time |
10:38 |
Sent To |
Z |
|
| Notes |
| 2007-09-05 10:39:49 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-17 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-17 |
Time |
09:18 |
Sent To |
E |
|
| Notes |
| 2007-07-17 09:18:36 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-13 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-13 |
Time |
09:27 |
Sent To |
Z |
|
| Notes |
| 2007-07-13 09:27:49 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-20 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-20 |
Time |
08:51 |
Sent To |
E |
|
| Notes |
| 2007-03-20 08:51:58 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-09 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-09 |
Time |
10:05 |
Sent To |
Z |
|
| Notes |
| 2007-03-09 10:06:14 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-10 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-10 |
Time |
09:36 |
Sent To |
E |
|
| Notes |
| 2006-12-10 09:37:19 | PLANS ROUTED TO DVP'S DESK, REMOVED FORM INCOMING. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2006-11-29 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2006-11-29 |
Time |
18:00 |
Sent To |
Z |
|
| Notes |
| 2006-11-29 18:01:24 | RESUB/MMCLEAN DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-23 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-11 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2006-10-12 14:29:36 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-07-20 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-07-20 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-07-20 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-09 |
Time |
13:53 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-09-09 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2008-09-09 13:54:18 | REVISION TO MECHANICAL PLAN A13, ENERGY CAL'S. AND | | | COOLING LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-12 |
Time |
14:17 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-09-12 |
Time |
14:17 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-18 |
Time |
09:32 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2007-07-18 |
Time |
09:32 |
Sent To |
P |
|
| Notes |
| 2007-07-18 10:01:36 | *** DENIED *** | | | 1) SEE MECHANICAL PLANS PAGE A13, SEE YELLOW HIGH | | | LIGHTED DUCTS THAT NEED TO BE SIZED, OR SHOW TWO | | | DIFFERENT SIZES FOR THE SAME DUCT, OR DUCT (FLEX) | | | MISSING, OR SIZED WRONG. PLEASE CORRECT. | | | | | | 2) SEE MECHANICAL PLANS LAUNDRY ROOM SHOWS A 4" METAL | | | DUCT AND A 12X12 BOX PLEASE STATE ON PLAN WHAT THEY ARE | | | FOR. | | | | | | 3) MECHANICAL PLAN ALSO NEEDS THE PRINTED NAME OF THE | | | PERSON WHO SIGNED THEM. | | | | | | 4) MECHANICAL PLANS NEED THE JOB ADDRESS IN THE TITLE | | | BLOCK. | | | | | | 5) PLEASE SHOW THE SEER IN THE EQUIPMENT SCHEDULE. | | | | | | 6) IS CLOTHES DRYER GAS OR ELECTRIC (NOT LISTED ON | | | ELECTRICAL PANEL BUT SHOWN AS 220 VOLT) IF GAS PROVIDE | | | COMBUSTION AIR. | | | | | | 7) ENERGY CALCULATIONS SHOW THE WATER HEATER AS GAS, | | | THE ELECTRICAL PLANS SHOW IT AS 220 VOLT, PLEASE | | | CORRECT. | | | | | | 8) SEE ENERGY CALCULATIONS ARE SHOWING THE WRONG BTU'S | | | FOR THE ELECTRIC HEAT STRIPS, WHEN CONVERTED TO KW THEY | | | DO NOT MATCH THE MECHANICAL PLANS, PLEASE CORRECT. | | | | | | 9) ENERGY CALCULATIONS LINE 11 SHOWS DUCT INSULATION IS | | | R-30, THE MECHANICAL PLANS SHOW THE DUCTS AS R-6, | | | PLEASE CORRECT ENERGY CALCULATIONS OR SUBMIT | | | MANUFACTURER'S SPECIFICATION SHEET FOR THE DUCTS | | | (FLEX). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-26 |
Time |
10:39 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-03-26 |
Time |
10:39 |
Sent To |
P |
|
| Notes |
| 2007-03-26 10:43:39 | *** DENIED *** | | | 1) SEE MECHANICAL PLANS PAGE A-13. ALL INFORMATION, | | | DRAWINGS, SPECIFICATIONS AND ACCOMPANYING DATA SHALL | | | BEAR THE PRINTED NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE | | | FOR THE DESIGN. PER FBC 104.2.1, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-11 |
Time |
09:47 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-11 |
Time |
09:47 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-18 |
Time |
08:53 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2006-10-18 |
Time |
08:53 |
Sent To |
Z |
|
| Notes |
| 2006-10-18 09:10:08 | *** DENIED *** | | | 1) SEE PAGE A13 A/C SCHEDULE UNIT #1 EQUIPMENT SENSIBLE | | | BTU'S ARE MORE THAN THE TOTAL BTU'S, PLEASE CORRECT. | | | | | | 2) SEE A/C SCHEDULE UNIT #3 CONDENSER MODEL NUMBER IS | | | FOR A 8 TON UNIT, PLEASE CORRECT. | | | | | | 3) SEE SECOND FLOOR STUDY ROOM 10" RETURN AIR DUCT IS | | | TO SMALL FOR 786 CFM'S OF SUPPLY AIR,PER FBC/R M1602.4, | | | PLEASE CORRECT. | | | | | | 4) PROVIDE RETURN SIR FOR AHU #1 TO FOYER SECOND FLOOR, | | | PER 2004 FBC/R M 1602.4. | | | | | | 5)ATTIC ACCESS MUST BE WITHIN SIX FEET OF THE AHU'S | | | SERVICE PANEL, PER 2004 FBC/R M 1305.1.3, PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-09-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-24 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-24 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-26 |
Time |
10:08 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2007-07-26 |
Time |
10:08 |
Sent To |
B |
|
| Notes |
| 2007-07-26 11:42:13 | DENIED 4TH TIME | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE WITH THE | | | ADDITION OF BATH 4 AND CABANA BATH.: | | | | | | 1. SHEET A15 THE RESUBMITTED ISOMETRIC SANITARY RISER | | | DIAGRAM DOES NOT REFLECT THE FLOOR PLAN IN THE | | | FOLLOWING AREAS. PER FBC-2004 CHAPTER 1, SECTION | | | 106.1.1 CONSTRUCTION DOCUMENTS (ISOMETRIC) SHALL BE OF | | | SUFFICIENT CLARITY TO THE LOCATION OF THE PROPOSED | | | WORK. | | | | | | A. ALL OF THE GROUND FLOOR PLUMBING (1/2 BATH, | | | KITCHEN, AND CABANA BATH). PLEASE REFERENCE THE | | | CORRECTED ISOMETRIC GROUND FLOOR PLUMBING THAT REFLECTS | | | THE FLOOR PLAN ON THIS SHEET FOR THE RESUBMITTAL. | | | | | | B. 2ND FLOOR MASTER BATH DOES NOT INDICATE THE 1/8 | | | BEND OFFSETS OR WYE FITTINGS AND THE LAV BY SHOWER | | | BEING INDICATED IN THE WRONG PLACE. THE TRAP IS BEING | | | INDICATED AS GOING OUT THE BACK WALL. PLEASE INDICATE | | | THE WASTE ARM AND CORRECT LOCATION OF TRAP. | | | | | | C. 2ND FLOOR LAUNDRY: SINK IN LAUNDRY IS MISLABELED, | | | IT SHOULD BE INDICATED AS A LAUNDRY TRAY (L.T.). THE | | | LAUNDRY TRAY WASTE ARM IS BEING INDICATED IN THE WRONG | | | PLACE. | | | | | | D. 2ND FLOOR STUDY: THE SINK IS BEING INDICATED ON THE | | | WRONG SIDE OF THE 4" HORIZONTAL SANITARY PIPE. | | | | | | E. 2ND FLOOR BATH 2: THE LAV WASTE IS BEING INDICATED | | | IN THE WRONG PLACE. | | | | | | F. 2ND FLOOR BATH 3 AND 4: FLOOR PLAN ON SHEET A6 ARE | | | INDICATING A TUBS, BUT THE SANITARY ISOMETRIC ARE | | | INDICATING SHOWERS. PLEASE CLARIFY OR CORRECT THIS ON | | | THE RESUBMITTAL. | | | | | | 2. SHEET A15 PLUMBING NOTES: PLEASE DELETE THE | | | FOLLOWING "PROVIDE MINIMUM PITCH 1/4" AT ALL HORIZONTAL | | | BRANCHES AND SEWER LINES PER 701.01. PLEASE ADD IN ITS | | | PLACE THE FOLLOWING "SLOPE OF HORIZONTAL DRAIN PIPE PER | | | TABLE 704.1" ON THE RESUBMITTAL. | | | | | | 3. SHEET A15 SANITARY ISOMETRIC RISER PLEASE INDICATE | | | THE FOLLOWING. | | | | | | A. PER FBC-2004 PLUMBING SECTION, 708.3.4: CLEANOUT AT | | | THE BASE OF THE 4" SOIL STACK TO THE 2ND FLOOR. | | | | | | B. PER FBC-2004 PLUMBING SECTION, 708.3.5: PLEASE | | | INDICATE A TWO-WAY CLEANOUT AT THE JUNCTION OF THE | | | BUILDING DRAIN AND BUILDING SEWER. | | | | | | 4.SHEET A15 2ND FLOOR PLUMBING PLAN: PLEASE CORRECT | | | THE BRANCH DRAIN TO THE LAUNDRY TO THREE INCH (3") PER | | | FBC-2004 PLUMBING SECTION 406.3. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-26 |
Time |
11:38 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-03-26 |
Time |
11:38 |
Sent To |
B |
|
| Notes |
| 2007-03-26 11:46:55 | DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION IS REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. FBC-2004 CHAPTER 1,SECTION 106.1.2: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-11 |
Time |
11:45 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-12-11 |
Time |
11:45 |
Sent To |
B |
|
| Notes |
| 2006-12-11 13:12:52 | DENIED 2ND TIME | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. ON SHEET A15 THE PLUMBING FLOOR PLAN LAYOUTS ARE | | | INDICATED WRONG. THE KITCHEN AND 1/2 BATH SHOULD BE | | | INDICATED AS THE GROUND FLOOR AND THE LAUNDRY, MASTER | | | BATH, BATH 2 AND BATH 3 SHOULD BE INDICATED AS THE 2ND | | | FLOOR PLUMBING. PLEASE CORRECT FOR THE RESUBMITTAL. | | | | | | 2. ON SHEET A15 SANITARY RISER DIAGRAM: THE VENT | | | INDICATED ON THE 2ND FLOOR PLUMBING PLAN IS MISSING ON | | | THE SANITARY RISER DIAGRAM. PLEASE CORRECT ON THE | | | RESUBMITTAL. | | | | | | 3. ON SHEET A15 SANITARY RISER DIAGRAM:PLEASE REMOVE | | | THE PARTIALLY DRAWN VENT TO THE FIRST FLOOR 1/2 BATH IT | | | IS ALREADY INDICATED. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-19 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-19 |
Time |
14:40 |
Sent To |
B |
|
| Notes |
| 2006-10-19 14:53:51 | DENIED; | | | 1.SANITARY RISER DIAGRAM; MASTER BATH ONLY HAS 2 | | | LAVATORIES. W/C IN HALF BATH IS NOT VENTED AS DRAWN. | | | 2.PLUMBING NOTES; HORIZONTAL PIPE TO BE PITCHED PER | | | 710.1. PIPE UNDER THREE INCH. TO SLOP A MINUMUM OF | | | 1/4". | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-09-12 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-09-05 |
Time |
14:15 |
Sent To |
M |
|
| Notes |
| 2007-09-12 11:52:12 | PROVISO ALL TREES SHALL BE PLANTED PURSUANT TO THE CITY | | | OF WEST PALM BEACH SUSTAINABLE PLANTING PLANS (ATTACHED | | | TO LANDSCAPE PLANS). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-07-17 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-07-13 |
Time |
12:24 |
Sent To |
I |
|
| Notes |
| 2007-07-17 08:16:02 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. BALCONY 1 OF BEDROOM 2 SHALL BE SHOWN ON THE SURVEY | | | AND SITE PLAN (REPEAT COMMENT). | | | A. FLOOR PLANS SHOW THAT THE BALCONY PROJECTS 2 FEET 9 | | | INCHES INTO THE FRONT YARD; HOWEVER THE BALCONY IS | | | STILL NOT SHOWN ON THE SITE PLAN OR SURVEY. | | | | | | 2. PLEASE PROVIDE BUILDING HEIGHT FROM THE GRADE TO THE | | | MID-POINT OF THE ROOF (REPEAT COMMENT). | | | A. PLEASE NOTE THAT BUILDING HEIGHT MAY NOT EXCEED 30 | | | FEET FROM GRADE TO THE MID-POINT BETWEEN THE ROOF RIDGE | | | AND THE ROOF EVE. | | | | | | 3. PLEASE PROVIDE A TABULAR DATA TABLE WITH THE | | | REQUIRED AND PROVIDED TREES AND SHRUBS (REPEAT | | | COMMENT). | | | A. PER SECTION 94-442(B)(2)(A), AT LEAST ONE SHADE, | | | FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 | | | SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.IN | | | ADDITION, AT LEAST ONE SHRUB SHALL BE PLANTED FOR EACH | | | 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF | | | (REPEAT COMMENT). | | | B. PLEASE NOTE THAT PER SECTION 94-442(C), PALM TREES | | | MAY BE SUBSTITUTED FOR NOT MORE THAN 35 PERCENT OF THE | | | SHADE OR FLOWERING TREES REQUIRED; HOWEVER, WHEN PALM | | | TREES ARE SUBSTITUTED FOR SHADE TREES, TWO PALM TREES | | | SHALL BE PROVIDED FOR EACH REQUIRED SHADE TREE. | | | | | | 4. SURVEY AND SITE PLAN DIMENSIONS SHALL SHOW SAME | | | CONDITION. | | | A. SOUTH PROPERTY LINE DEPTH DIMENSION AND WEST | | | PROPERTY LINE WIDTH DIMENSION SHALL BE REVISED TO SHOW | | | DIMENSIONS ON SURVEY. | | | | | | 5. PLEASE NOTE THAT SETBACK DIMENSIONS ARE MEASURED TO | | | THE FURTHEST PROJECTION POINT, TO INCLUDE A VENEER OR | | | CLADDING.THIS SHALL APPLY TO ALL BALCONIES. | | | | | | 6. PROPOSED POOL, POOL DECK, AND WALL/FENCE (WITH AN | | | APPROVED EASEMENT CONSENT FORM), SHALL BE APPROVED | | | UNDER SEPARATE PERMITS.THIS SHALL BE NOTED ON THE | | | SITE PLAN AND LANDSCAPE PLAN. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-03-16 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-03-16 |
Time |
16:02 |
Sent To |
I |
|
| Notes |
| 2007-03-16 16:16:30 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. SECOND FLOOR TUB POP-OUT IS PART OF THE PRIMARY | | | STRUCTURE AND SHALL MEET THE MINIMUM REQUIRED SIDE | | | SETBACK OF 12.5 FEET FROM THE SIDE PROPERTY LINE. | | | | | | 2. SETBACK DIMENSIONS FROM PROPERTY LINE TO A/C UNITS | | | AND ALL OTHER MECHANICAL EQUIPMENT SHALL BE PROVIDED. | | | | | | 3. BALCONY 1 OF BEDROOM 2 SHALL BE SHOWN ON THE SURVEY | | | AND SITE PLAN. | | | | | | 4. PLEASE PROVIDE BUILDING HEIGHT FROM THE GRADE TO THE | | | MID-POINT OF THE ROOF. | | | | | | 5. PLEASE PROVIDE A TABULAR DATA TABLE WITH THE | | | REQUIRED AND PROVIDED TREES AND SHRUBS. | | | A. PER SECTION 94-442(B)(2)(A), AT LEAST ONE SHADE, | | | FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 | | | SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.IN | | | ADDITION, AT LEAST ONE SHRUB SHALL BE PLANTED FOR EACH | | | 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-12-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-08 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-08 |
Time |
07:58 |
Sent To |
I |
|
| Notes |
| 2006-12-08 08:38:34 | DENIED. 2ND REQUEST. | | | 1. THE BALCONY ON SECOND FLOOR STILL PROJECTS 4FT INTO | | | SETBACK. SEC 94-305(2). | | | 2. THE ROOF PROJECTION FROM BALCONY CAN ONLY BE LINED | | | WITH THE BALCONY PROJECTING 3FT. SEC 94-305(2). PLANS | | | A-2 SHOWS THE BALCONY PROJECTING 4FT, 1FT ROOF | | | OVERHANG, WHICH CAN ONLY PROJECT 3FT INCLUDING | | | PILISTAR. | | | 3. THE 2ND FLOOR PROJECTION BAY WINDOWS CAN ONLY | | | PROJECT18 INCHES ON SIDE SETBACK OF CORTEZ.SURVEYS | | | SHOWS 2 1/2 FT ON SIDE. SEC 94-305(8) | | | | | | NOTE: THE PROPOSED A/C UNIT SHALL NOT BE CLOSER THAN | | | 1.41FT FROM SIDE AND 8FT REAR PROPERTY LINE. | | | NOTE: SEPARATE PERMIT MUST BE PULLED FOR THE PROPOSED | | | POOL/SPA | | | NOTE: SEPARATE PERMIT MUST BE PULLED FOR THE PROPOSED | | | FENCE/GATE/WALL WITH CITY OF WEST PALM BEACH UTILITY | | | EASEMENT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-10-18 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-10-18 |
Time |
14:18 |
Sent To |
P |
|
| Notes |
| 2006-10-18 14:29:47 | DENIED, | | | 1. MUST PULL A SEPARATE PERMIT FOR THE PROPOSED | | | POOL/SPA. | | | 2. MUST PULL A SEPARATE PERMIT FOR THE PROPOSED WALL | | | WITH EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH | | | UTILITY DEPT. | | | 3. THE PROPOSED BALCONY CAN ONLY PROJECT 3FT INTO | | | REQUIRED SETBACK. SEC 94-305 (2) | | | 4. THE PROPOSED BAY WINDOWS CAN ONLY PROJECT 18 INCHES | | | INTO ANY SIDE SETBACK. SEC 94-305(8). | | | | | | | | | NOTE: THE PROPOSED POOL EQUIPMENT SHALL NOT BE | | | CLOSER THAN 1FT FROM SIDE PROPERTY LINE. |
|
|