| Plan Review Stops For Permit 06100138 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-10-16 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-10-16 |
Time |
10:18 |
Sent To |
PC |
|
| Notes |
| 2006-10-16 10:20:01 | TWO EXTENSIONS #0007 FRO UNIT 120 AND #0008 FOR UNIT | | | 121 WERE CREATED.TWO PERMIT NECESSARY? | | 2006-10-13 14:43:28 | NEEDS, TWO SUITES.? |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-22 |
Time |
17:36 |
Rev Time |
1.10 |
| Received By |
jwitmer |
Date |
2007-01-22 |
Time |
17:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-13 |
Time |
15:05 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-12-13 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2006-12-13 15:19:45 | BUILDING PLAN REVIEW | | | PERMIT: 06100138 | | | ADD: 1475 CENTREPARK BLVDSUITES 120 & 121 | | | CONT: PASS INTERNATIONAL | | | TEL: (561)706-7201 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 3) COVERSHEET PROJECT DATA BUILDING TYPE IV | | | UNPROTECTED UNDER THE 2004 FBC | | | IS FOR HEAVY TIMBER CONSTRUCTION PLEASE UPDATE | | | THE BUILDING TRMINOLGY TO THE 2004 FBC. | | | TABLE 601. | | | | | | 4) COVERSHEET GENERAL NOT# 3 INDICATES DESIGNED TO | | | THE AMERICANS WITH DISSIBILITY ACT, | | | PLEASE CORRECT TO THE FLORIDA BUILDING CODE CHAPTER 11, | | | | | | THE FLORIDA ACCESSIBILITY REQUIREMEENTS ARE MORE | | | STRINGENT | | | THAN THE ADA ANDAPPROVED BY THE DEPARTMENT OF | | | JUSTICEAS SO. | | | | | | 5) SHEET A-2 BREAK ROOM SINKS, ARE HIGHLIGHTED WITH THE | | | LANGUAGE | | | INDICATING A FORWARD APPROACH COULD BE MADE EXCEPT | | | THAT THE PLAN STILL INDICATES THERE TO BEADJUSTIBLE | | | SHELVING IN THE ACCESSIBLE UNITS. | | | | | | 6)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | G ) NUMBER OF FLOORS | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-12 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-12 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2006-10-12 12:49:59 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY | | | SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | | THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT | | | COMMENCED WITHIN 90 DAYS OF RECORDING. | | | | | | 2.SHOW HOW SINKS IN BOTH KITCHEN AREAS WILL COMPLY | | | WITH THE CLEAR FLOOR SPACE FOR A WEEL CHAIRFBC | | | 11-4.24.5 | | | ONE SINK MAY NEED TO BE MOVED OVER AND ONE MAY NEED TO | | | HAVE A CLEAR AREA UNDERNEATH.SHOW ON PLANS. | | | | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-19 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-18 |
Time |
17:53 |
Sent To |
PC |
|
| Notes |
| 2007-10-19 08:04:52 | REV FOR SUITE/METER LABELING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-22 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-22 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2007-01-22 13:18:16 | STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-12-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-08 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-08 |
Time |
09:17 |
Sent To |
I |
|
| Notes |
| 2006-12-08 14:00:11 | **** UNSAT 2ND REVIEW ***** | | | | | | ** PLEASE SEE SOME COMMENTS FROM THE PREVIOUS REVIEW | | | WHICH IS STILL IN NEED OF ADDRESSING ALONG WITH SOME | | | NEW NOTES WITH THE CHANGES MADE ON PLANS. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | THE PREVIOUS REVIEW WITH A NOTATION OF "NO" OR "OK". | | | PLEASE SEE SOME MAY BE NOTED AS "OK/NO" AS PART OF THE | | | COMMENT MAY HAVE BEEN ADDRESSED HOWEVER NOT FULLY. | | | | | | 1) NOTE: OK.. | | | | | | 2) NOTE: OK. | | | | | | 3) NOTE: OK. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE:NO, PLEASE SEE THE NOTE WAS LOCATED ABOUT H | | | NON-BONDING OF THE NEUTRAL, HOWEVER A NOTE OR | | | INDICATION FOR THE REQUIRED "FLOATING NEUTRAL" COULD | | | NOT LOCATE DON THE RISER. THIS IS BEING REQUESTED AS WE | | | HAVE HAD NUMEROUS SITUATIONS OUT IN THE FIELD WHERE | | | THIS IS NOT BEING DONE CORRECTLY. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE/ NOTE THE "FLOATING NEUTRAL" AT THE | | | TENANT METERS. 250.6, 250.24B. | | | | | | 6) NOTE:NO, PLEASE SEE 13-415.1.ABC.1.1, AND .1.2. | | | PLEASE SEE CONTROLS REQUIRED COULD NOT BE LOCATED. | | | PLEASE SEE PREVIOUS REVIEW NOTE. | | | PLEASE SEE ENERGY CALCULATIONS WHICH MENTIONS "MANUAL | | | ON/OFF" YET, ACTUALLY THIS SHOULD INDICATE "AUTO" | | | ON/OFF"ON THE PROGRAM. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FBC 13-415.1.ABC.1.1, .1.2 AND .1.3 FOR MIN | | | LIGHTING CONTROLS FOR EACH SPACE. | | | PLEASE SEE 13-415.2.ABC.1 FOR MAX LPD'S. (LIGHTING | | | POWER DENSITIES). | | | | | | 7) NOTE: OK/NO, PLEASE SEE POWER PLANS WHICH THE ROOM | | | #'S ARE NOT ON PLANS. THIS IS OK ON THE LIGHTING | | | PLANS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE ROOM/OFFICE DESIGNATIONS SPECIFIC TO | | | ROOM OR AREA. IE; OFFICE RECEPTS 101, OFFICE RECEPTS | | | 104, ETC. | | | 408.6, 240.4, 310.16. | | | FBC 106.1.2 | | | | | | 8) NOTE: OK. | | | | | | 9) NOTE: OK. | | | | | | 10) NOTE: NO/OK. PLEASE SEE THE LOCATIONS ARE NOW BEING | | | SHOWN; HOWEVER PLEASE SEE NOTE ON RISER MENTIONS 25FT | | | MAX FOR THE CONDUCTORS ON THE SECONDARY SIDE OF THE | | | TRANSFORMER YET PLEASE SEE 240.21C AS THE CONDUCTORS ON | | | THE SECONDARY SIDE ARE ONLY PERMITTED AT 25FT IN A | | | DIFFERENT SCENARIO. PLEASE ADJUST NOTE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE VERIFY AND SHOW LOCATIONS OF TRANSFORMERS. | | | PLEASE ALSO PROVIDE MORE OF A DETAIL FOR THE "TAPS" | | | BEING DONE ON THE PRIMARY SIDES OF THE TRANSFORMERS FOR | | | THE VAV'S. | | | PLEASE SEE 240.21, 450.9 ETC | | | | | | ** ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-12-08 09:18:04 | REMOVED FROM INCOMING, IN ELECTRICA FOR REVIEW AND WILL | | | BE ROUTED BACK TO INCOMING ONCE COMPLETED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-10-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-13 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-13 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2006-10-13 15:29:10 | | | | | | | ***** UNSAT ****** | | | | | | 1) NOTE: PLEASE SEE THE FOLLOWING MINIMUM CODES SHALL | | | BE REFELECTED ON PLANS.2002 NFPA-70, 2002 NFPA-72, | | | 2003 NFPA-101 FBC 2004. SOME OF THESE ARE SHOWN ON | | | ARCHITECTURAL PLANS, HOWEVER SHOULD ALSO BE ON | | | ELECTRICAL PLANS. | | | | | | 2) NOTE: PLEASE BE SURE PLANS ARE SIGNED WITH SIGNATURE | | | AS ON FILE AND RECOGNIZED BY THE CITY OF WEST PALM | | | BEACH. | | | FS 471.025 | | | | | | 3) NOTE: PLEASE INDICATE THE CONTINUOUS LOADS AT 125%. | | | 215.3, 230.42 | | | | | | 4) NOTE: PLEASE INDICATE MIN AIC RATINGS ON THE OCP | | | DEVICES AT MAINS. | | | 110.9, FBC 106.1.2 | | | | | | 5) NOTE: PLEASE INDICATE/ NOTE THE "FLOATING NEUTRAL" | | | AT THE TENANT METERS. 250.6, 250.24B. | | | | | | 6) NOTE: PLEASE SEE FBC 13-415.1.ABC.1.1, .1.2 AND .1.3 | | | FOR MIN LIGTHING CONTROLS FOR EACH SPACE. | | | PLEASE SEE 13-415.2.ABC.1 FOR MAX LPD'S. (LIGHTING | | | POWER DENSITIES). | | | | | | 7) NOTE: PLEASE PROVIDE ROOM/OFFICE DESIGNATIONS | | | SPECIFIC TO ROOM OR AREA. IE; OFFICE RECEPTS 101, | | | OFFICE RECETPS 104, ETC. | | | 408.6, 240.4, 310.16. | | | FBC 106.1.2 | | | | | | 8) NOTE: PLEASE LIST THE MIN LIGHTING/AUDIO LEVELS | | | REQUIRED PER2004 FBC ADA 11-4.28. IT IS NOTED ON | | | PLANS, HOWEVER SPECIFIC LEVELS IS REQUIRED TO BE SHOWN | | | FOR EACH. | | | | | | 9) NOTE: PLEASE VERIFY RISER AS THIS SHOWS "NEUTRAL" | | | CONDUCTORS ON THE LINE SIDE OF THE TRANSFORMERS? PLEASE | | | SEE 250.20,250.30, ETC. | | | | | | 10) NOTE: PLEASE VERIFY AND SHOW LOCATIONS OF | | | TRANSFORMERS. PLEASE ALSO PROVIDEMORE OF A DETAIL FOR | | | THE "TAPS" BEING DONE ON THE PRIMARY SIDES OF THE | | | TRANSFORMERS FOR THE VAV'S. | | | PLEASE SEE 240.21, 450.9 ETC | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-24 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-24 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2007-01-24 12:37:10 | *****APPROVED***** | | | | | | | | | SHEET E- 2 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-12 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-12 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2006-12-12 13:02:31 | *****APPROVED***** | | | | | | | | | | | | | | | PLANS TO BE STAMPED WHEN OTHER PLAN REVIEWS COMMENTS | | | HAVE BEEN SATISFIED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-26 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-26 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2006-10-26 14:59:41 | *****DENIED***** | | | | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION SHALL COMPLY WITH NFPA 241. | | | | | | 2.ACCUMULATIONS OF COMBUSTIBLE WASTE AND DUST DEBRIS | | | SHALL BE REMOVED FROM THE STRUCTURE AND ITS IMMEDIATE | | | VICINITY AT THE END OF THE SHIFT OR MORE FREQUENTLY AS | | | NECESSARY FOR SAFE OPERATIONS. | | | | | | 3.EXITS AND EXIT ACCESS CORRIDORS ARE TO BE | | | MAINTAINED AND REMAIN CLEAR AND OBSTRUCTED. | | | | | | 4.)IF THE SCOPE OF TE INTERIOR BUILDOUT REQUIRES | | | MODIFICATION OF THE FIRE ALARM OR FIRE SPRINKLER | | | SYSTEM, SEPARATE PERMIT AND PLAN ARE TO BE SUBMITTED | | | FOR REVIEW. | | | | | | 5.INTERIOR FINISH FOR WALL AND CEILING IN EXITS AND | | | EXIT ACCESS CORRIDORS SHALL BE CLASS "A" OR CLASS "B". | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-18 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-18 |
Time |
10:26 |
Sent To |
E |
|
| Notes |
| 2007-10-18 10:26:36 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
13:56 |
Sent To |
M |
|
| Notes |
| 2007-08-21 13:56:31 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-22 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-22 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2007-01-24 15:03:35 | | | | | | | | | | 1/24/07PASSED.SENT TO DEWEY PALMER'S DESK FOR | | | PROCESSING.RB | | 2007-01-22 11:35:05 | TO "BOB"#16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-21 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-21 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2006-12-12 11:39:30 | TO "BOB"#3 | | 2006-11-21 14:26:23 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-27 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-06 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2006-10-12 09:50:34 | TO "BOB"#18 | | 2006-10-06 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-22 |
Time |
08:11 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-08-22 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2007-08-22 08:13:26 | REVISION, SUBMITTED DETAIL TO WALL WERE FIRE DAMPER IS | | | INSTALLED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-12 |
Time |
14:39 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-12 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-16 |
Time |
14:22 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-10-16 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2006-10-16 14:26:17 | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE | | | # 2, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-21 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-21 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-27 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-27 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2006-10-27 14:39:38 | DENIED; | | | 1. SEE ELECTRICAL PLAN REVIEW'S NOTE 2. | | | 2. ADD TO KEY NOTE #7 NO DEAD ENDS INSANITARY | | | DRAINAGE SYSTEM LONGER THAN 2 FT PLUMBING INSPECTION | | | REQUIRED. | | | 3.BREAK ROOM SINKS SHALL COMPLY WITH FBC-2004 CHAPTER | | | 11 SECTIONS 11-4.24.2 THRU 11-4.24.7. | | | 11-4.24.2HEIGHT OF SINK | | | 11-4.24.3KNEE CKEARANCE | | | 11-4.24.4DEPTH OF SINK | | | 11-4.25.5CLEAR FLOOR SPACE | | | 11-4.25.6EXPOSED PIPES | | | 11-4.24.7FAUCETS | | | SHOW ALL MEASUREMENTS PERTAINING TO ABOVE CODES ON | | | PAGE A-2 ELEVATION 1 | | | SHOW CLEAR FLOOR SPACE ON FLOOR PLAN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|