| Plan Review Stops For Permit 06091101 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-10-02 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-09-29 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | ATTACH PERMIT EXT #0001 UNDER PCN = | | | 74434321010020080 | | 2006-09-29 00:00:00 | ADDRESS DOES NOT MATCH PCN # |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-06-02 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-06-02 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2008-06-02 19:32:17 | SUBMITTAL ON 6/2/08 FOR LETTER FROM CLOPAY BUILDING | | | PRODUCTS' ENGINEER ON THE AIR INFILTRATION AT THE | | | GARAGE DOORS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-05-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-05-23 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-05-23 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2008-05-23 13:50:11 | IMPACT PROTECTION REVISION APPROVED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-03-19 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-03-19 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2008-03-19 15:01:45 | GARAGE DOOR REVISIONOK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-12-21 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-12-21 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-11-09 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-11-09 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2007-11-09 08:53:53 | SITE SPECIFIC NOT APPROVED. GARAGE DOOR SUBMITTAL SHALL | | | COMPLY WITH ARCHITECT'S DESIGN PRESSURES ON SHEET | | | A-1.01. | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-11-02 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-11-02 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2007-11-02 11:24:36 | GARAGE DOOR PRODUCT APPROVAL TESTED +- PRESSURES ARE | | | LOWER THAN DESIGN PRESSURES PROVIDED ON PLANS BY | | | ARCHITECT. THE PA IS ALSO MISSING THE INSTALLATION | | | ENGINEERING. | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-18 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-18 |
Time |
10:55 |
Sent To |
Z |
|
| Notes |
| 2006-10-18 11:00:15 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY | | | SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | | THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT | | | COMMENCED WITHIN 90 DAYS OF RECORDING. | | | | | | 2.SEPERATE PERMIT REQUIRED FOR AWNINGS AND SIGNS. | | | | | | 3.CLEARLY SHOW SIZE AND NUMBER OF EGRESS DOORS. | | | | | | 4.PRODUCT APPROVALS REQUIRED FOR WINDOWS, DOORS AND | | | OVERHEAD DOORS. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY | | | ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL | | | ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF | | | THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | | FORM PER RULE 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. | | | | | | | | | | | | 9.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR | | | A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS | | | WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC | | | EXISTING BUILDING 301.5 | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6672 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-23 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-23 |
Time |
09:20 |
Sent To |
B |
|
| Notes |
| 2008-04-23 09:21:31 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-07 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-07 |
Time |
15:03 |
Sent To |
B |
|
| Notes |
| 2007-11-07 15:04:08 | TO "LMARTINEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
10:33 |
Sent To |
Z |
|
| Notes |
| 2007-09-17 10:33:41 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-10-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-13 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-13 |
Time |
15:20 |
Sent To |
B |
|
| Notes |
| 2006-10-13 15:20:15 | TO "MISC' BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-31 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-03 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-09-19 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-09-19 |
Time |
10:01 |
Sent To |
B |
|
| Notes |
| 2007-09-19 10:05:13 | ZONING REVIEW: PASSED | | | | | | * SIDEWALK LEVEL FACADE MODIFICATIONS | | | * SIGNAGE NOT INCLUDED AND SHALL BE REVIEWED UNDER | | | SEPARATE PERMIT | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2006-10-31 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2006-10-31 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2006-10-31 13:33:46 | - SIGNAGE TO BE REVIEWED UNDER SEPARATE PERMIT, AND | | | NOT INCLUDED WITH THIS APPROVAL. | | | | | | -MJF |
|
|