Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-10-25 Cont ID  
Sent By alange Date 2006-10-25 Time 11:04 Rev Time 0.00
Received By alange Date 2006-10-25 Time 11:04 Sent To  
Notes
2006-10-25 11:09:38DENIED
  
  
 1.SIGN OWNER/AGENT ON ENERGY CALCS PER 2004 FBC.
  
 2.SUBMIT TWO ORIGINAL SIGNED AND SEALED SURVEYS.FS
 472.025
  
 3.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY
 ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL
 ATTACHED.PRODUCT APPROVALS SUBMITTED WITH THE
 INCORRECT STATE PAGES.PAGES SUBMITTED SHOULD ALSO
 SHOW MAKE PGT FOR EXAMPLE MODEL 701 AND APPROVED
 STATUS.
  
 PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT
 LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF
 THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC
 FORM PER RULE 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 4.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER
 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE
 APPROVED PRIOR TO INSTALLATION.
  
 5.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR
 A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS
 WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC
 EXISTING BUILDING 301.5
  
 6.R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHESWITHIN THE FIRST 10 FEET.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE
 COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DEPARTMENT
 561-805-6672
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-06-19 Cont ID  
Sent By dpalmer Date 2007-06-19 Time 11:29 Rev Time 0.00
Received By dpalmer Date 2007-06-19 Time 09:59 Sent To P
Notes
2007-06-19 11:29:19*** PROVISO/REVISION NEEDED ***
  
 1) NOTE: PLEASE SUBMIT LOAD CALCULATIONS CODE COMPLIANT
 TO 220.31B UNDER THE 2002 NEC>
 PLEASE SEE THE TOTAL LOAD SHOWN ON PANEL B IS
 SUBSTANTIALLY HIGHER THAN THAT OF THE LOAD SHOWN ON THE
 LOAD CALCULATIONS.
 PLEASE ALSO SEE THE LOAD SHOWN ON PANEL SCHEDULE FOR
 AHU AND HEAT DOES NOT CORRELATE WITH THE LOAD
 CALCULATIONS.
  
 ** PLEASE REVISE AND SUBMIT THIS REVISION ALONG WITH
 ANY OTHER REVISIONS BEFORE ANY ROUGH ELECTRICAL
 INSPECTION.
 PLEASE KNOW IF PLANS ARE NOT REVISED BY ROUGH, THE
 PERMIT FOR BUILDING WILL BE PLACED INTO A HOLD STATUS
 UNTIL COMMENTS ARE ADDRESSED. THIS CORRECTED REVISION
 MAY BE SUBMITTED AS SOON AS POSSIBLE ONCE PERMIT IS
 ISSUED.
  
 IF THERE ARE ANY QUESTIONS PLEASE DO NOT HESITATE IN
 CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-01-24 Cont ID  
Sent By dpalmer Date 2007-01-24 Time 17:39 Rev Time 0.00
Received By dpalmer Date 2007-01-24 Time 12:50 Sent To M
Notes
2007-01-24 17:40:14*** UNSAT2ND REVIEW ***
  
 ** PLEASE SEE THERE ARE COMMENTS FROM THE PREVIOUS
 REVIEW WHICH STILL NEED TO BE ADDRESSED ALONG WITH NEW
 COMMENTS BASED ON THE REVISED RISER AND REVISED PANEL
 SCHEDULE(S) SUBMITTED.
  
 1) NOTE: OK.
  
 2) NOTE: OK.
  
 3) NOTE: OK.
  
 4) NOTE: NO, SEE COMMENT BELOW.
  
 ** PREVIOUS REVIEW NOTE #4**
 PLEASE SEE POSSIBLE MISSING GFI FOR KITCHEN COUNTER
 SPACE. 210.52C1,210.8A6.
  
 5) NOTE:NO, PLEASE STILL SEE MISSING RECEPTACLE IN
 KITCHEN FOR 2FT OR MORE OF WALL SPACE.
  
 ** PREVIOUS REVIEW NOTE #5 **
 PLEASE SEE SOME MISSING RECEPTS PER 210.52 AS THESE
 ROOMS WHERE ELECTRICAL IS TAKING PLACE APPEAR TO BE
 REWIRED?
 PLEASE KNOW, DUE TO THE ALTERATION IN DWELLING, PLEASE
 INDICATE EXISTING RECEPTS (E) .
 FBC 106.1.2 ADMIN SECT.
  
 6) NOTE: NO, PLEASE SEE THREE SETS OF PLANS ARE BEING
 SUBMITTED. PLEASE SEE ALL THREE ARE NEW AND ARE SIGNED,
 DATED AND SEALED BY THE ARCHITECT; HOWEVER THE THIRD
 SET OF PLANS ARE NOT SIGNED, DATED OR SEALED BY THE
 ENGINEER. PLEASE KNOW THAT ONLY TOW SETS ARE REQUIRED,
 HOWEVER IF THREE SETS ARE BEING SUBMITTED FOR REVIEW
 AND FOR STAMPING THEN ALL THREE SETS ARE REQUIRED TO BE
 SIGNED , DATED AND SEALED. FS 471.025, FAC
 61G15-23.002.
  
 ** PREVIOUS REVIEW NOTE #6**
 PLEASE SEETHERE ARE A COUPLE OF SEALS FROM ENGINEER
 WHICH ARE NOT CLEAR AND VISIBLE WITH ALL INFORMATION ON
 SAID SEAL.
 FS 471.025
  
 7) NOTE: OK.
  
 8) NOTE:NO, PLEASE SEE NEW RISER NOTES FOR REVISED
 RISER SUBMITTED. PLEASE SEE AS SHOWN, THIS SERVICE IS
 BEING DONE A 250 AMP SERVICE. PLEASE SEE 310.15B6 FOR
 MINIMUM SIZES FOR THE SEC?S.
 ** PLEASE CALL TO GO OVER THIS COMMENT.
  
 ** PREVIOUS REVIEW NOTE #8**
 PLEASE SEE SERVICE ENTRANCE CONDUCTORS SHALL BE SIZED
 PER 310.15B6 AT A MINIMUM. SERVICE SHOWN IS 250A'S.
 240.4
  
 9) NOTE:NO, SAME NOTE.
  
 ** PREVIOUS REVIEW NOTE #9**
 PLEASE ADJUST METER CAN SIZE FOR SERVICE (300A MIN).
 110.3, 90.7, 240.4
  
 10) NOTE: NO, SAME NOTE DEPENDING ON THE OUTCOME OF THE
 SERVICE BEING PROVIDED. AS SHOWN THE GEC IS TOO SMALL.
  
 ** PREVIOUS PLEASE SEE 250.66 AS THE MIN SIZE OF THE
 GROUNDING ELECTRODE CONDUCTOR SHALL BE #2 BASED ON THE
 NEW SEC'S WHICH WILL BE REQUIRED FOR THE SERVICE SIZE
 AS SHOWN.
  
 11) NOTE: NO, PLEASE SEE THERE ARE SOME CIRCUITS NOW
 BEING SHOWN FOR THE EXISTING PANEL WHICH SEEM TO BE
 DEDICATED/MOTOR/APPLIANCE CIRCUITS; HOWEVER IT IS
 UNCLEAR WHERE THESE ARE FIGURED INTO THE MAIN LOAD
 CALCULATIONS.
  
  
 ** PREVIOUS REVIEW NOTE #11**
 PLEASE PROVIDE PANEL SCHEDULE AND LOAD INFORMATION FOR
 EXISTING PANEL"A". SEEMS TO BE ONLY A 5A DIFFERENCE
 IN LOAD.
 240.4, 220.31B
  
 12) NOTE: OK.
  
 13) NOTE: OK.
  
 14) NOTE:NO, PLEASE SEE THIS ELECTRIC WATER HEATER IS
 STILL SHOWN IN THE CLOSET.
  
 ** PREVIOUS REVIEW NOTE #14**
 PLEASE SEE 422.17, AS THE ELEC HWH SEEMS TO BE SHOWN IN
 THE CLOTHES CLOSET. PLEASE PROVIDE MIN SEPARATION
 REQUIRED OR RELOCATE.
  
 15) NOTE: OK.
  
 *** NEW NOTES ***
  
  
 16) NOTE: PLEASE CORRELATE RISER DIAGRAM AND PANELS.
 PLEASE SEE THE RISER SHOWS A 100A MBC PANEL, PANEL
 SHOWS A 100A PANEL WITH A 150A MCB AND SHOWS A 60AMP
 MAIN BREAKER BEING BACK-FED.????
 PLEASE SEE OF THIS 60A BREAKER IS NOT THE SERVICE
 ENTRANCE RATED MAIN, PLEASE SUBMIT DETAILS IF INDEED
 THIS IS THE CASE.
 17) NOTE: PLEASE CORRELATE FEEDERS /SERVICE ENTRANCE
 CONDUCTORS TO THIS EXISTING PANEL AND NEW PANEL. PLEASE
 SEE PANEL SCHEDULE INDICATES THESE AS FEEDERS, WHEN
 THEY ARE SERVICE ENTRANCE CONDUCTORS. PLEASE ALSO SEE
 THE CONDUCTORS ON RISER DO NOT CORRELATE WITH THAT OF
 THE PANEL SCHEDULE WHICH SHOWS A DIFFERENT CONDUCTOR
 SIZE.
  
 18) NOTE: PLEASE SEE RISER IS SHOWING *EQUIPMENT
 GROUNDING CONDUCTORS* FROM THE METER TO THE FIRST MEANS
 OF DISCONNECT WHICH IS NOT PERMITTED. PLEASE SEE 250.6,
 AND 250.24B. PLEASE SEE THIS IS PARALLELING THE
 NEUTRAL.
  
 19) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO
 DESIGN PROFESSIONALS AND REPEAT COMMENTS FOR CODE
 COMPLIANCE. THIS IS ONLY BEING GIVEN AS A NOTICE AT
 THIS TIME.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-10-16 Cont ID  
Sent By dpalmer Date 2006-10-16 Time 19:47 Rev Time 0.00
Received By dpalmer Date 2006-10-16 Time 13:13 Sent To M
Notes
2006-10-16 19:47:56********* UNSAT ***********
  
 1) NOTE: PLEASE STATE THE FOLLOWING RELEVANT CODES ON
 THE PLANS. 2002 NFPA-70 (NEC) , 2002 NFPA-72. FA CODE.
  
 2) NOTE: PLEASE VERIFY THE SMOKE DEVICES BEING
 INSTALLED AS SHOWN. PLEASE SEE NFPA-72 ABOVE
 DEFINITIONS FOR SD (SMOKE DETECTORS) AND SA'S (SMOKE
 ALARMS). PLEASE ADJUST NOTE ON PLANS AND SYMBOLS. IT
 SEEM THESE MAY INDEED BE SA'S.
  
 3) NOTE: PLEASE CLARIFY REQUIREMENTS FOR 210.70 LS 101
 7.8 AS SOME AREAS/ ROOMS SEEM TO SHOW A FAN ONLY BEING
 INSTALLED FOR EGRESS LTS WHERE SOME SORT OF FIXTURE IS
 REQUIRED. PLEASE KNOW, EITHER FAN AND AND LT KIT WILL
 BE REQUIRED OR 1/2 SW RECEPT ETC OR ONLY LT.
  
 4) NOTE; PLEASE SEE POSSSIBLE MISSING GFI FOR KITCHEN
 COUNTER SPACE. 210.52C1, 210.8A6.
  
 5) NOTE: PLEASE SEE SOME MISSING RECEPTS PER 210.52 AS
 THESE ROOMS WHERE ELECTRICAL IS TAKING PLACE APPEAR TO
 BE REWIRED.?
 PLEASE KNOW , DUE TO THE ALTERATION IN DWELLING, PLEASE
 INDICATE EXISTING RECEPTS (E) .
 FBC 106.1.2 ADMIN SECT.
  
 6) NOTE: PLEASE SEETHERE ARE A COUPLE OF SEALS FROM
 ENGINEER WHICH ARE NOT CLEAR AND VISABLE WITH ALL
 INFORMATION ON SAID SEAL.
 FS 471.025
  
 7) NOTE: PLEASE VERIFY THE KW RATING FOR AHU, AS THE
 LOAD CALCULATIONS SHOW 10KW, YET PANEL SCHEDULE AND OCP
 DO NOT CORRELATE.
 PLEASE SEE 424.3B , 240.4, 310.16 FOR ANY ADJUSTMENTS.
 PLEASE SEE MECH PLANS AS THESE ALSO ONLY SHOW 6KW? FOR
 THIS SIZE HOUSE?
  
 8) NOTE: PLEASE SEE SERVICE ENTRANCE CONDUCTORS SHALL
 BE SIZED PER 310.15B6 AT A MINIMUM. SERVICE SHOWN IS
 250A'S.
 240.4
  
 9) NOTE: PLEASE ADJUST METER CAN SIZE FOR SERVICE (300A
 MIN).
 110.3, 90.7, 240.4
  
 10) NOTE: PLEASE SEE 250.66 AS THE MIN SIZE OF THE
 GROUNDING ELECTRODE CONDUCTOR SHALL BE #2 BASED ON THE
 NEW SEC'S WHICH WILL BE REQUIRED FOR THE SERVICE SIZE
 AS SHOWN.
  
 11) NOTE: PLEASE PROVIDE PANEL SCHEDULE AND LOAD
 INFORMATION FOR EXISTING PANEL"A". SEEMS TO BE ONLY A
 5A DIFFERENCE IN LOAD.
 240.4, 220.31B
  
 12) NOTE: PLEASE SEE THAT THE NEW FOOTER STEEL WILL BE
 REQUIRED TO BE PART OF THE NEW GROUNDING ELECTRODE
 SYSTEM. 250.50, PLEASE SHOW.
  
 13) NOTE: PLEASE SEE MISSING SA'S LEADING TO FLOOR
 ABOVE IN THE IMMEDIATE VICINITY OF THE STAIRS AND AT
 THE 2ND FLR LEVEL AS REQUIRED PER NFPA-72 11.5.1.1,
 11.8.3, 2004 FBC R313
  
 14) NOTE: PLEASE SEE 422.17, AS THE ELEC HWH SEEMS TO
 BE SHOWN IN THE CLOTHES CLOSET. PLEASE PROVIDE MIN
 SEPARATION REQUIRED OR RELOCATE.
  
 15) NOTE: PLEASE PROVIDE THE PANEL SCHEDULE WITH
 SPECIFIC AREAS AND ROOMS IN WHICH CIRCUITS FEED."IE":
 MASTER BEDRM LTS, MASTER BDRM RECEPTS, LIVING RM LTS,
 DINING RM RECEPTS.ETC.
 408.4, 310.16.
 IT IS KNOW TO THIS OFFICE THAT CIRCUITING WILL MOST
 LIKELY BE REVISED AND CHANGED DURING CONSTRUCTION,
 HOWEVER THIS IS REQUIRED AT THIS TIME AND CANE REVISE
 PANEL SCHEDULE AT A LATE DATE.
  
 ** PLEASE SEE ONE SET OF THE ELECTRICAL PLANS SUBMITTED
 ARE REDLINED AT MANY AREAS AS NOTED ABOVE.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2006-09-29 Cont ID  
Sent By ssherman Date 2006-09-29 Time 11:32 Rev Time 0.00
Received By ssherman Date 2006-09-29 Time 11:30 Sent To  
Notes
2006-09-29 00:00:00HISTORICAL APPROVAL PER GALINA JUDGE

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-06-12 Cont ID  
Sent By adarroug Date 2007-06-12 Time 09:10 Rev Time 0.00
Received By adarroug Date 2007-06-12 Time 09:10 Sent To E
Notes
2007-06-12 09:10:30TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-01-22 Cont ID  
Sent By adarroug Date 2007-01-22 Time 16:20 Rev Time 0.00
Received By adarroug Date 2007-01-22 Time 16:20 Sent To E
Notes
2007-01-22 16:20:56TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-01-16 Cont ID  
Sent By adarroug Date 2007-01-16 Time 16:16 Rev Time 0.00
Received By adarroug Date 2007-01-16 Time 16:16 Sent To Z
Notes
2007-01-16 16:16:46TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-10 Cont ID  
Sent By adarroug Date 2006-10-10 Time 19:43 Rev Time 0.00
Received By adarroug Date 2006-10-10 Time 19:43 Sent To E
Notes
2006-10-10 19:43:40TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-25 Cont ID  
Sent By alange Date 2006-10-25 Time 11:09 Rev Time 0.00
Received By alange Date 2006-10-03 Time 14:30 Sent To  
Notes
2006-10-03 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-01-25 Cont ID  
Sent By tgordon Date 2007-01-25 Time 09:24 Rev Time 0.30
Received By tgordon Date 2007-01-25 Time 09:24 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-10-17 Cont ID  
Sent By tgordon Date 2006-10-17 Time 08:54 Rev Time 0.45
Received By tgordon Date 2006-10-17 Time 08:53 Sent To P
Notes
2006-10-17 09:09:22*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY
 OWNER/AGENT, PER 2004 FBC 13-600.3.ABC.2 .
  
 2) MANUAL J CALCULATIONS ARE CALLING FOR 22,281
 SENSIBLE BTU'S, AND THE MECH. PLANS ARE CALLING FOR
 48,900 SENSIBLE BTU'S, THE PLANS CAN ONLY CALL FOR 20%
 MORE THAN THE MANUAL J CAL'S, PER 2004 FBC
 13-607.1.ABC.1.1, PLEASE CORRECT.
  
 3) THE MECH. PLANS ARE CALLING FOR A 6 KW HEATER, AND
 THE ELECT. PLANS ARE CALLING FOR A 10 KW HEATER, THE
 TWO MUST COINCIDE, PLEASE CORRECT.
  
 4) SEE PAGE M-3 CONDENSER UNIT DETAIL, A METAL BAND MAY
 NOT GO OVER THE CONDENSER UNIT, PLEASE CORRECT.
  
 5) SEE PAGE M-1 FIRST FLOOR MASTER SUITE, 20X20 RAG
 DUCT IS NOT SIZED, PLEASE CORRECT. NOTE IF THE AHU
 CLOSET IS AN OPEN RETURN WITH A LOUVERED DOOR THAN THE
 RETURN AIR DUCT WOULD NOT BE NEEDED .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-07-02 Cont ID  
Sent By jleech Date 2007-07-02 Time 09:36 Rev Time 0.00
Received By jleech Date 2007-07-02 Time 09:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-02-08 Cont ID  
Sent By jleech Date 2007-02-08 Time 08:00 Rev Time 0.00
Received By jleech Date 2007-02-08 Time 08:00 Sent To B
Notes
2007-02-08 08:08:38DENIED;
 1. ONE SET OF PLANS ARE NOT SEALED AND ONE SET IS
 MISSING PAGE P-1.
 2. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE 3". SEE
 FBC-2004 PLUMBING SECTION 406.3.
 3. MASTER BATH WET VENT FOR W/C SHOULD BE 3" NOT 2" SEE
 TABLE 909.3.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-10-21 Cont ID  
Sent By jleech Date 2006-10-21 Time 12:35 Rev Time 0.00
Received By jleech Date 2006-10-21 Time 12:35 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-01-22 Cont ID  
Sent By adavila Date 2007-01-22 Time 12:13 Rev Time 0.00
Received By adavila Date 2007-01-22 Time 12:13 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-10-10 Cont ID  
Sent By adavila Date 2006-10-10 Time 15:13 Rev Time 0.00
Received By adavila Date 2006-10-10 Time 15:13 Sent To I
Notes
2006-10-10 15:16:5010/10/06 ***FAILED***
  
 1) LANDSCAPE NEEDS TO MEET SUSTAINABLE PLANTING
 REQUIREMENTS.
 A) ROOT BALL SHALL BE SLIGHTLY ABOVE GRADE
 B) PLANTING HOLE WILL BE THREE (3) TIMES THE DIAMETER
 OF THE ROOT BALL ON THE SURFACE AND TWO (2) TIMES THE
 ROOT BALL DIAMETER AT THE BASE.
  
 COMMENTS/QUESTIONS, CONTACT LINDA M. FRANCO, SENIOR
 PLANNER, AT 822-1435.