| Plan Review Stops For Permit 06091064 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-04-01 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-04-01 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2008-04-01 18:17:38 | REVISION TO REPAIR ROOF AND SIDINGOKLM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-02-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-02-01 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-02-01 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2008-02-01 13:33:11 | REVISION FOR REAR STEPS AND FLOOR CHANGE AT LAUNDRY | | | AREA OKLM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-07-25 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-07-25 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2007-07-25 14:36:07 | REVISION FOR FOUNDATION APPROVED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-13 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-13 |
Time |
19:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-24 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-24 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2006-10-24 13:11:27 | DENIED | | | | | | | | | 1.SUBMIT TWO ORIGINAL SIGNED AND SEALED SURVEYS.FS | | | 472.025 | | | | | | 2.SHOW THE TYPE OF LAP SIDING USED. | | | | | | 3.SHOW ROOF SHEATHING NAILING SCHEDULE.FBC 2304.9.1 | | | TABLE 31 | | | | | | 4.SUBMIT TWO COPIES OF ENERGY CALCS PER 2004 FBC. | | | | | | 5.DOOR STATE PRODUCT APPROVAL MISSING EVALUATION | | | REPORT.ROOF PRODUCT APPROVAL MISSING STATE PRODUCT | | | APPROVAL.ALL PRODUCT APPROVALS SUBMITTED WITH | | | QUALITY ASSURANCE SHALL HAVE THE FOLLOWING STATE | | | APPROVAL ATTACHED. | | | | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF | | | THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | | FORM PER RULE 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 6.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. | | | | | | | | | 7.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER | | | 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE | | | APPROVED PRIOR TO INSTALLATION. | | | | | | 8.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR | | | A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS | | | WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC | | | EXISTING BUILDING 301.5 | | | | | | 9.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | | OF 6 INCHESWITHIN THE FIRST 10 FEET. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6672 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-20 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-20 |
Time |
08:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-07 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-07 |
Time |
12:25 |
Sent To |
PC |
|
| Notes |
| 2008-03-07 12:26:09 | ** DENIED REVIEWFOR REVISION ** | | | | | | ** PLEASE SEE SEVERAL ITEMS FROM ORIGINAL *PROVISO* | | | GIVEN ON 5/8/07 HAVE NOT BEEN ADDRESSED. | | | | | | 1) NOTE: PLEASE SEE MISSING REQUIRED FOOTER STEEL AS | | | PART OF THE GROUNDING ELECTRODE SYSTEM. | | | 250.50 | | | | | | 2) NOTE: PLEASE SEE MISSING REFLECTED CODES TO BE | | | STATED ON PLANS. | | | 2005 NFPA-70 | | | 2004 FBC W/2006 REVISIONS | | | 2002 NFPA-72 | | | | | | 3) NOTE: PLEASE SEE THE CIRCUITING FOR DINING ROOM | | | RECEPTACLES ARE STILL SHOWING #14 AWG AND 15AMP | | | BREAKERS WHEN THE CODE SPECIFICALLY REQUIRE THE MINIMUM | | | OF 20AMP AND #12 AWG. | | | THIS WAS REDLINED ON PREVIOUS PLANS ISSUED FOR PERMIT | | | AND STILL HAS NOT BEEN CHANGED. | | | | | | 4) NOTE: PLEASE SEE THE LOADS WHICH ARE REQUIRED TO BE | | | FIGURED INTO LOAD CALCULATIONS FOR DINING ROOM CIRCUITS | | | SHALL BE PER 220.52, 210.11C1 AND 210.52B1 | | | ** MINIMUM 1500VA FOR EACH AND THIS LOAD SHALL BE IN | | | ADDITION TO ANY OTHER SMALL APPLIANCE CIRCUITS. | | | ON PREVIOUS REVIEW AND REDLINED ON PLANS WITH | | | PROVISO*. | | | | | | 5) NOTE: PLEASE SEE THE REFRIGERATOR CIRCUIT WHICH | | | STILL SHOWS #14 AWG WITH 20AMP BREAKER WHICH IS NOT | | | PERMITTED. | | | 240.4, 310.16 ETC | | | ** NOTED ON PREVIOUS REVIEW AND REDLINED ON PLANS ALONG | | | WITH PROVISO. | | | | | | 6) NOTE: PLEASE SHOW THE LOCATION OF ALL SERVICE | | | EQUIPMENT ON PLANS MEETING 110.26, 240.24 PLEASE | | | INDICATE THE EXISTING MAIN AS PART OF THE SERVICE. THE | | | LOAD CALCULATIONS STATE *PROPOSED SERVICE* YET THE | | | RISER SHOWS *EXISTING*? | | | FOR EXAMPLE: PLEASE SEE THE SERVICE PANEL OUTSIDE IS | | | SHOWN DIRECTLY BEHIND THE CONDENSING UNIT WHICH DOES | | | NOT MEET 110.26 AND ONE OR THE TWO ARE REQUIRED TO | | | MOVE. | | | | | | 7) NOTE: PLANS APPEAR TO BE MISSING A GFI RECEPTACLE | | | ALONG KITCHEN COUNTER SPACE WITHIN 2FT OF THE END PER | | | 210.52C1. | | | PLEASE VERIFY AND ADJUST ON PLANS. BASED ON SCALE SHOWN | | | THIS IS MISSING. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-08 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-07 |
Time |
17:08 |
Sent To |
PC |
|
| Notes |
| 2007-05-08 14:31:34 | *** PROVISO/REVISION *** | | | | | | ** IMPORTANT** | | | THE FOLLOWING ITEMS MUST BE REVISED AND ADDRESSED ALONG | | | WITH ANY OTHER CHANGES BEFORE A*ANY* ROUGH ELECTRICAL | | | INSPECTION. | | | A *HOLD* WILL BE PLACED ON THE ELECTRICAL SUB-PERMIT | | | FOR INSPECTIONS. | | | | | | 1) NOTE: PLEASE SEE THE DINING ROOM/BREAKFAST AREA | | | LOADS OF 1500 VA ON PANEL SCHEDULE ARE NOT FIGURED INTO | | | THE LOAD CALCULATIONS PER 210.11C1, 210.52B1, 220.16 | | | PLEASE SEE THE OCP AND AWG IS SHOWN AS 15AMP AND #14 ON | | | ONE OF THE CIRCUITS WHICH REQUIRES 20AMP AND #12. | | | PLEASE REVISE LOAD CALCULATIONS, PANEL SCHEDULE, OCP | | | AND AWG. | | | | | | 2) NOTE: PLEASE INDICATE THE FOLLOWING CODES ON PLANS | | | AS REQUESTED ON PREVIOUS REVIEW AS FOLLOWS: | | | 2002 NFPA-70 | | | 2002 NFPA-72 | | | | | | 3) NOTE: PLEASE SEE THE LOAD ON THE PANEL SCHEDULE FOR | | | THE WATER HEATER IS SHOWN LARGER THAN THE LOAD ON THE | | | LOAD CALCULATIONS. | | | THE OCP IS BASED ON THE 125% OF THE NAMEPLATE LOAD AND | | | THE LOAD FIGURED IN FOR THE SERVICE CALCULATIONS IS | | | BASED ON THE 125%.IF THE NAMEPLATE LOAD IS HIGHER | | | THAN THE 4.5KW (SHOWN ON LOAD CALCULATIONS ) THEN THE | | | OCP WOULD BE REQUIRED TO BE HIGHER THAN THE 2-POLE | | | 25AMP BREAKER ON PANEL SCHEDULE. | | | PLEASE SEE 422.13, 240.4, 310.16 | | | | | | 4) NOTE: PLEASE SEE THE REFRIGERATOR CIRCUIT WHICH | | | SHOWS A 20AMP BREAKER ON #14 AWG. | | | PLEASE CORRECT. | | | 240.4, 310.16 | | | | | | 5) NOTE: PLEASE SEE THE STEEL LISTED PART THE GROUNDING | | | ELECTRODE SYSTEM IS TO INCLUDE *FOOTER* STEEL AS | | | REQUIRED PER 250.50 | | | | | | ** PLEASE SEE THAT THE ABOVE CORRECTIONS ARE MADE ALONG | | | WITH ANY OTHER ELECTRICAL REVISIONS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | 2007-05-07 17:08:51 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-21 |
Time |
19:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-21 |
Time |
19:09 |
Sent To |
M |
|
| Notes |
| 2007-03-21 19:47:15 | | | | | | | ****** UNSAT2ND REVIEW ****** | | | | | | ** PLEASE SEE THERE ARE MANY ITEMS FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING ALONG WITH NEW | | | COMMENTS BASED ON CHANGES IN PLANS, OR NEW ITEMS SHOWN | | | WHICH WERE NOT ON PREVIOUS PLANS. | | | | | | 1) NOTE: PLEASE BE SURE THE PLANS REFLECT THE FOLLOWING | | | RELEVANT CODES 2002 NFPA-70 (NEC), 2002 NFPA-72. SAME | | | NOTE FROM PREVIOUS REVIEW. | | | | | | 2) NOTE: PLEASE COMPLETE ALL CIRCUITING ON PLANS AND | | | CORRELATE WITH THE PANEL SCHEDULE NOW SUBMITTED. PLEASE | | | SEE SMOKE ALARMS WHICH ARE MISSING CIRCUITING. PLEASE | | | BE SURE TO ALSO SEE 210.12 FOR AFCI PROTECTION | | | REQUIRED. | | | 310.16, 240.4, 408.4 | | | | | | 3) NOTE: PLEASE SEE A RISER DIAGRAM IS NOW SHOWN AND | | | SHOWS THE SERVICE AS EXISTING, YET THE PANEL WHICH IS | | | NOTED ON RISER IS NOT SHOWN ON PLANS FOR LOCATION. | | | PLEASE SEE 110.26, 408.7 AND 240.24. | | | | | | 4)NOTE: PLEASE SEE 210.8A6 AS ALL RECEPTACLES SERVING | | | KITCHEN COUNTER SPACE ARE REQUIRED TO BE GFI/GFI | | | PROTECTED. SAME NOTE ON PREVIOUS REVIEW. | | | | | | 5) NOTE: PLEASE SEE 250.50 AS THE NEW FOOTER STEEL IS | | | REQUIRED ON THE RISER FOR THE GROUNDING ELECTRODE | | | SYSTEM. | | | | | | 6) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.16 FOR | | | DINING ROOM. PLEASE SEE THE LOAD IS BEING SHOWN AT | | | 1200VA. | | | PLEASE ALSO SEE THESE SAME SECTIONS OF THE CODE AS THE | | | LOAD FOR THE SMALL APPLIANCE CIRCUITS ARE BEING SHOWN | | | WITH THE SAME 1200VA. | | | NOTED ON PREVIOUS REVIEW. | | | | | | 7) NOTE: PLEASE SEE 210.8A1 FOR RECEPTACLES IN BATH | | | ROOMS WHICH ARE REQUIRED TO BE GFI. | | | PLEASE ALSO SEE EXISTING BATHROOMS. | | | PLEASE ALSO SEE THE MISSING GFI RECEPTACLE REQUIRED IN | | | POWDER RM. | | | 210.52D, 210.11C1 | | | | | | 8) NOTE: PLEASE SEE WATER HEATER SHOWN WITHOUT THE | | | REQUIRED DISCONNECT PER 422.30, 422.31. | | | | | | 9) NOTE: PLEASE SHOW LOAD CALCULATIONS FOR HOUSE PER | | | 220.31B. | | | SAME NOTE ON PREVIOUS REVIEW. | | | | | | 10) NOTE: PLEASE SEE RISER NOW SHOWS A 2-POLE BREAKER | | | FOR GFI CIRCUIT? PLEASE ALSO SEE RISER ALSO SHOWS A | | | 2-POLE 60AMP CIRCUIT TO POOL EQUIPMENT; HOWEVER POOL | | | EQUIPMENT WOULD MEAN A POOL PANEL AS CIRCUITED. IF THIS | | | IS THE CASE PLEASE INCLUDE PANEL ON RISER, FEEDERS | | | ETC. | | | | | | IF THERE IS NO PANEL, THEN THIS WOULD NOT BE A 60AMP | | | BREAKER FOR GENERAL POOL EQUIPMENT. | | | PLEASE CLARIFY THIS INFORMATION. | | | 240.4, 310.16, | | | FBC 106.1.2, 106.3.5.4 | | | | | | 11) NOTE: PLEASE SHOW THE LOCATION OF THE A/C EQUIPMENT | | | REQUIRED DISCONNECTS PER 440.11. | | | | | | 12) NOTE: PLEASE SEE NOW NOTE #24 ON PLANS; THIS HAS | | | CHANGED FROM PREVIOUS PLANS WHICH WAS NOTE #22. PLEASE | | | SEE THIS AS IT REFERENCES CODES FROM THE 1996 NFPA-72. | | | PLEASE SEE AT PRESENT WITH THE 2002 NFPA-72, 11.5.1.1, | | | AND 11.8.3 IS THE CURRENT SECTIONS FOR INSTALLATIONS OF | | | SMOKE ALARMS. PLEASE SEE PLAN NOTE MENTIONS SD'S IS | | | SMOKE DETECTORS. PLEASE SEE PLANS NOW SHOW SA FOR SMOKE | | | ALARMS. PLEASE SEE 11.8.3 AS THE SA SHOWN OUTSIDE | | | BEDROOM #2 AND #3 IS SHOWN TOO CLOSE TO THE BATHROOM | | | DOOR. MUST BE AT LEAST 3FT FROM DOOR OPENING. | | | PART OF THIS IS STILL FROM PREVIOUS REVIEW NOTES WITH | | | RESPECT TO OLD CODE BEING REFERENCED. | | | | | | 13) NOTE: PLEASE CLARIFY THE FIXTURES SHOWN IN CLOSETS | | | TO MEET 410.8. PLEASE KNOW AN ASSUMED 12" SHELF SHALL | | | BE DETERMINED. | | | | | | 14) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | DESIGN PROFESSIONALS AND REPEAT COMMENTS FOR CODE | | | COMPLIANCE. | | | | | | 15) NOTE: PLEASE SEE THE RISER WHICH DOES NOT INCLUDE | | | ANY EXISTING OR NEW MAIN. HOW IS THIS PANEL WHICH IS | | | BEING NOTED AS EXISTING 200AMP PANEL BEING FED? PLEASE | | | ELABORATE ON RISER AND PROVIDE COMPLETED INFORMATION ON | | | RISER AS NOTED. | | | 215.5, 230.2, 230.70, 230.71, 230.72, 240.4, 310.16 | | | ETC. | | | FBC 106.1.2, 106.3.5.4 | | | | | | 16) NOTE: PLEASE SEE THE NOTICE OF COMMENCMENT WHICH | | | WAS RECORDED IN 9/06 HAS EXPIED PER FS 713.13(2). | | | PLEASE KNOW THAT A NEW RECORDED NOC WILL BE REQUIRED | | | BEFORE PICKING UP PERMIT AFTER ISSUANCE. IT IS | | | SUGGESTED THAT THE NOC DOES NOT GET RE-RECORDED UNTIL | | | PERMIT IS ISSUED. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-16 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-15 |
Time |
20:57 |
Sent To |
M |
|
| Notes |
| 2006-10-16 07:50:19 | ****** UNSAT ********* | | | | | | 1) NOTE: PLEASE BE SURE THE PLANS REFLECT THE FOLLOWING | | | RELEVANT CODES 2002 NFPA-70 (NEC), 2002 NFPA-72 . | | | | | | 2) NOTE: PLEASE COMPLETE THE PANEL SCHEDULE INCLUDING | | | ALL CONDUCTOR SIZES ALONG WITH THE OCP | | | DEVICES/BREAKERS. 310.16, 240.4, 408.4 | | | | | | 3) NOTE: PLEASE SEE LOAD CALCS MENTIONS "OVENS" YET | | | ONLY ONE SHOWN ON PANEL SCHEDULE AND LOAD CALCS. PLEASE | | | CLARIFY AND ADJUST. | | | 220.31, 408.4 ETC. | | | | | | 4)NOTE: PLEASE SEE 210.8A6 AS ALL RECEPTS SERVING | | | KITCHEN COUNTER SPACE ARE REQUIRED TO BE GFI/GFI | | | PROTECTED. | | | | | | 5) NOTE: PLEASE BE SUREPANEL SCHEDULE IS SPECIFIC TO | | | ROOMS AND AREAS IN WHICH THEY FEED. IE: BEDRM #2 | | | RECEPTS, BATH RECEPTS, ETC | | | 408.4, 310.16, 240.4 | | | | | | 6) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.16 FOR | | | DINING ROOM.(NEW OR EXSITIGN?) | | | | | | 7) NOTE: PLEASE SEE 210.8A1 FOR RECEPTS IN BATH RMS | | | WHICH ARE REQUIRED TO BE GFI. | | | PLEASE ALSO SEE EXISITING BATHRMS ARE BEING SHOWN AS | | | WORK BEING IN THOSE AREAS, PLEASE SEE HOWEVER THERE ARE | | | NOT GFI RECEPTS INIDCATED ON PLANS ? ARE THEY GOING TO | | | BE NEW OR EXISTING. | | | 210.52D, 210.11C1 | | | | | | 8) NOTE: PLEASE SEE 422.17 FOR WHAT APPEARS TO BE A | | | WATER HEATER IN A STORAGE CLOTHES CLOSET WHICH IS NOT | | | PERMITTED. | | | | | | 9) NOTE: PLEASE SHOW LOAD CALCULATIONS FOR HOUSE PER | | | 220.31B. | | | | | | 10) NOTE: PLEASE SHOW LOCATION OF SERVICE ON PLANS. | | | PANEL, METER OR MAIN? | | | IF THIS GOING TO BE A NEW SERVICE PLEASE SUBMIT A | | | COMPLETE RISER DIAGRAM ALONG WITH AIC RATINGS , | | | CONDUCTORS, GROUNDING ETC. | | | | | | 11) NOTE: PLEASE SEE NOTE ON PLANS MENTIONS ALL | | | EXISTIGN BEDRMS BEING REWIRED TO CODE, HOWEVER PLEASE | | | PROVIDE A LAYOUT FOR EITHER NEW OR EXISTING RECEPTS | | | MEETING SPACING REQUIRMENTS PER 210.52. | | | | | | 12) NOTE: PLEASE SHOW THE LOCATION OF THE A/C EQUIPMENT | | | AND REQUIRED DISCONNECT'S PER 440.11. | | | | | | 13) NOTE: PLEASE SHOW REQUIRED GFI PER 210.63/210.8A2 | | | | | | 14) NOTE: PLEASE SEE NOTE #22 ON PLANS AS IT REFERENCES | | | CODES FROM THE 1996 NFPA-72. | | | PLEASE SEE AT PRESENT WITH THE 2002 NFPA-72, 11.5.1.1, | | | AND 11.8.3 ARE THE CURRENT SECTIONS FOR INSTALLATIONS | | | OF SMOKE ALARMS. PLEASE SEE PLANS MENTIONS SD'S IS | | | SMOKE DETECTORS. PLEASE VERIFY AS IF THESE ARE SMOKE | | | DETECTORS, PLEASE VERIFY THE SYSTEM BEING INSTALLED AND | | | WHAT DEVICES AND LOCATIONS FOR AUDIBLE SIGNAL WILL BE. | | | PLEASE SEE DEFINITIONS AS THIS SEEMS PERHAPS THEY | | | SHOULD BE SHOWN AS "SA"'S SMOKE ALARMS. | | | PLEASE BE AWARE OF THE OCATIONF OF THE SD/SA SHOWN AT | | | AHU LOCATION, 5'MIN AWAY FROM RA GRILLE(ONLY NOTED). | | | | | | 15) NOTE: PLEASE SEE LOAD CALCS MENTIONS | | | "FUTURELANSCAPE LTS" YET NO LOADS SHOWN? | | | | | | 16) NOTE: PLEASE CLARFIY THE FIXTURES SHOWNIN CLOSETS | | | TO MEET 410.8. PLEASE KNOW AN ASSUMNED 18" SHELF SHALL | | | BE DETERMINED. | | | | | | ** PLEASE KNOW AS THERE IS INFORMATION NOT YET | | | SUBMITTED THERE MAY BE FUTURE COMMENTS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2006-10-15 20:58:46 | IN ELEC FOR REVIEW , NOTES TO FOLLOW |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2006-09-29 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2006-09-29 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2006-09-29 00:00:00 | HISTORICAL APPROVAL PER JILLIAN PAPA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-14 |
Time |
13:51 |
Sent To |
Z |
|
| Notes |
| 2008-04-14 13:52:16 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-09 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-09 |
Time |
08:53 |
Sent To |
Z |
|
| Notes |
| 2008-04-09 08:53:42 | TO "Z" BOX/SUBMITTLAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-03-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-17 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-17 |
Time |
14:39 |
Sent To |
E |
|
| Notes |
| 2008-03-17 14:39:35 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-07 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-07 |
Time |
09:01 |
Sent To |
B |
|
| Notes |
| 2008-03-07 09:02:21 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-07 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-07 |
Time |
08:43 |
Sent To |
P |
|
| Notes |
| 2008-03-07 08:44:20 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-04 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-04 |
Time |
09:10 |
Sent To |
M |
|
| Notes |
| 2008-03-04 09:11:36 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-03 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-03 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2008-03-03 16:32:55 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-20 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-20 |
Time |
12:05 |
Sent To |
M |
|
| Notes |
| 2008-02-20 12:05:42 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-20 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-20 |
Time |
11:59 |
Sent To |
P |
|
| Notes |
| 2008-02-20 11:59:55 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-15 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-15 |
Time |
11:45 |
Sent To |
B |
|
| Notes |
| 2008-01-15 11:45:33 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-12 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-12 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2007-07-12 14:07:11 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
13:06 |
Sent To |
E |
|
| Notes |
| 2007-05-03 13:07:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-20 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-20 |
Time |
11:17 |
Sent To |
E |
|
| Notes |
| 2007-03-20 11:17:33 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-10 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-10 |
Time |
09:30 |
Sent To |
E |
|
| Notes |
| 2006-10-10 09:30:48 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-24 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-03 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-26 |
Time |
13:39 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2008-03-26 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2008-03-26 13:40:11 | MECH. REVISION TO PLAN HVAC. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-04 |
Time |
15:55 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-03-04 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2008-03-04 15:56:32 | REVISION TO MECH. PLAN, ENERGY CAL'S. AND COOLING LOAD | | | CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-22 |
Time |
14:41 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2008-02-22 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2008-02-22 14:49:21 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | ** MECHANICAL REVISION TO PLANS ** | | | *** DENIED *** | | | 1) COOLING LOAD CALCULATIONS ON FILE ARE CALLING FOR | | | 32,785 TOTAL COOLING BTU'S, MECHANICAL REVISION IS | | | SHOWING TWO SYSTEMS TOTALING 47,600 COOLING BTU'S. THE | | | PLANS CAN ONLY CALL FOR 15% MORE THAN THE COOLING LOAD | | | CAL'S, SEE 2004 FBC 13-607.1.ABC.1.1. PLEASE CORRECT | | | PLANS OR COOLING LOAD CAL'S. | | | | | | 2) PLEASE SHOW THE LOCATION OF CONDENSER UNIT #2 ON | | | PLAN. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-26 |
Time |
13:49 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-26 |
Time |
13:49 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-16 |
Time |
08:28 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-16 |
Time |
08:28 |
Sent To |
P |
|
| Notes |
| 2006-10-16 08:36:27 | *** DENIED *** | | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER | | | 2004 FBC 13-101.2.2. | | | | | | 2) PLEASE SHOW LOCATION OF A/C CONDENSER | | | UNIT ON MECHANICAL PLANS. | | | | | | 3) SHOW LOCATION OF BATHROOM EXHAUST | | | FAN AND CLOTHES DRYER VENT TERMINATION | | | ON MECHANICAL PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-10 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-10 |
Time |
07:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-02-25 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-02-25 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2008-02-25 10:29:36 | DENIED; | | | 1. AUTOMATIC CLOTHES WASHER SHALL DISCHARGE DOWN STREAM | | | OF THE BATHROOM GROUP. SEE FBC PLUMBING SECTION 909.1. | | | 2. APPROVED "P" PAGE WAS RED LINES, TO EXPEDITE PLANS, | | | CHANGES WERE NOT MADE ON NEW REVISION. | | | PLANS ARE RED LINED . PLEASE MAKE CHANGES. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-02 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-02 |
Time |
09:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-21 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-21 |
Time |
12:49 |
Sent To |
B |
|
| Notes |
| 2006-10-21 13:00:21 | 1. AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO BE 3" | | | SECTION 406.3 CLEANOUT REQUIRED AT 48" AFF. | | | 2.W/M TO DISCHARGE DOWN STREAM OF THE BATHROOM GROUP | | | SECTION 909.1 | | | 3.SHOWER BATH, SHOWER IS NOT VENTED THE WET VENT FOR | | | THE BATHROOM GROUP SHOULD BE THE | | | BEFORE THE SHOWER TO RELEAVE THE NEGATIVE PRESSURE | | | FROM TOILET. | | | 4.DISHWASHER TO DISCHARGE INTO THE TAIL PIECE OF THE | | | KITCHEN SINK. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-15 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-15 |
Time |
11:46 |
Sent To |
PC |
|
| Notes |
| 2008-04-15 11:47:00 | ***APPROVED - LANDSCAPE PLAN SUBMITTAL*** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-09 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-09 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2008-04-09 16:06:52 | ***FAILED - SUBMITTAL - LANDSCAPE PLAN*** | | | | | | | | | 1)TWO (2) COPIES OF ALL PLANS SHALL BE SUBMITTED, | | | ONE FOR CITY'S RETENTION AND ONE TO BE POSTED AT | | | JOBSITE.PLEASE SUBMIT TWO (2) COPIES OF ALL | | | DOCUMENTS. | | | | | | 2)ANYTHING OTHER THAN LANDSCAPING INDICATED ON PLANS | | | (SUCH AS FENCES, PATIOS, ETC) SHALL BE REMOVED FROM | | | PLANS OR LABELED "TO BE PERMITTED SEPARATELY" AS SOME | | | ITEMS SHOWN ARE NOT CODE COMPLIANT. | | | | | | 3)LANDSCAPE PLAN SHALL INDICATE OPEN SPACE AND | | | REQUIRED LANDSCAPING CALCULATIONS. | | | | | | 4)LANDSCAPE PLANS SHALL SHOW COMPLIANCE WITH BOTH | | | SECTIONS 94-442 AND 94-445 OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | INCLUDING, BUT NOT LIMITED TO: | | | *PLANT MATERIAL SPECIFICATIONS: PLANT QUALITY. | | | *PLANS SHALL INDICATE THAT THE REQUIRED IRRIGATION | | | SYSTEM (FOR BOTH THE YARD AND SWALE/PARKWAY AREA) WILL | | | BE APPLIED FOR. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2006-10-05 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2006-10-05 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|