| Plan Review Stops For Permit 06091005 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-25 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-25 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-18 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-18 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2006-12-18 14:05:24 | DENIED BY BUILDING | | | | | | 1)SOME OF THE ID TAGS FOR DETAILS ON SP-1.04 AND | | | SP-2.02 DO NOT THE CORRECT DETAIL NUMBER OR PAGE | | | NUMBER. SEE REDLINE CORRECTIONS ON PLANS. | | | | | | 2) ITEM NUMBERS 5, 6 AND 7 FROM THE FIRST REVIEW HAVE | | | NOT BEEN ADDRESSED. SEE FIRST REVIEW. | | | | | | 3) PLEASE PROVIDE A RESPONSE LETTER SPECIFING HOW EACH | | | ONE OF THE PLAN REVIEW COMMENTS HAS BEEN ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-07 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-07 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2006-11-07 16:51:31 | DENIED BY BUILDING | | | | | | 1)THREE SETS OF SIGNED AND SEALED PLANS FOR THE POOL | | | AND SPA ARE REQUIRED TO BE SUBMITTED WITH THE PERMIT | | | APPLICATION (# 06091005). | | | | | | BASED ON A REVIEW OF OUR FILE SET OF PLANS THAT WERE | | | SUBMITTED FOR THE POOL PLUMBING PERMIT (# 06071766) | | | PLEASE SEE THE FOLLOWING COMMENTS: | | | | | | 2)SOME OF THE DETAIL TAGS ON SHEET SP-104 LIST THE | | | WRONG PAGE NUMBER. PLEASE CORRECT. | | | | | | 3) ON SP-1.05 THE DETAIL TAG FOR THE POOL LADDER LISTS | | | THE WRONG PAGE NUMBER. | | | | | | 4) ON SP-2.02 THE DETAIL TAG FOR THE ANCHOR SOCKET | | | DETAIL HAS THE WRONG DETAIL NUMBER AND PAGE NUMBER. | | | | | | 5) 13-412.1.ABC.2.6.1 TIME SWITCHES. | | | TIME SWITCHES SHALL BE INSTALLED ON SWIMMING POOL | | | HEATERS AND PUMPS. | | | EXCEPTIONS: | | | 1.WHERE PUBLIC HEALTH STANDARDS REQUIRE | | | 24-HOUR PUMP OPERATION. | | | 2.WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR | | | AND WASTE HEAT RECOVERY POOL HEATING SYSTEMS. | | | | | | 6) 13-412.1.ABC.2.6.2 POOL COVERS. | | | HEATED POOLS SHALL BE EQUIPPED WITH A VAPOR RETARDANT | | | POOL COVER ON OR AT THE WATER SURFACE. POOLS HEATED TO | | | MORE THAN 90?F (32?C) SHALL HAVE A POOL COVER WITH A | | | MINIMUM INSULATION VALUE OF R -12. | | | EXCEPTION: POOLS DERIVING OVER 60 PERCENT OF THE ENERGY | | | FOR HEATING FROM SITE-RECOVERED ENERGY OR SOLAR ENERGY | | | SOURCE. | | | | | | 7) 13-412.1.ABC.2.6.3 POOL HEATERS. | | | POOL HEATERS SHALL BE EQUIPPED WITH A READILY | | | ACCESSIBLE ON-OFF SWITCH TO ALLOW SHUTTING OFF THE | | | HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING. POOL | | | HEATERS FIRED BY NATURAL GAS SHALL NOT HAVE | | | CONTINUOUSLY BURNING PILOT LIGHTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-07 |
Time |
20:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-07 |
Time |
20:11 |
Sent To |
|
|
| Notes |
| 2006-12-07 20:12:17 | SHEET E5.02 ATTACHED FOR REFERENCE OF POOL PANEL , | | | EQUIPMENT, OCP DEVICES AND CONDUCTOR SIZES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-17 |
Time |
20:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-17 |
Time |
19:54 |
Sent To |
|
|
| Notes |
| 2006-10-17 20:10:19 | ******UNSAT *********** | | | | | | 1) NOTE: PLEASE SUBMIT A COMPLETE ELECTRICAL WIRING | | | DETAIL SHOWING THE CONDUCTORS, CONDUITS , OCP DEVICES | | | ETC FOR THE EQUIPMENT SCHEDULE WHICH IS BEING SHOWN. | | | THE DISCONNECTS ON SHEETSP 201 ARE NOT COMPLETE AT | | | THIS TIME FOR REVIEW. | | | PLEASE ALSO ONLY SUBMIT THE PANEL SCHEDULE WHICH FEEDS | | | THIS EQUIPMENT FOR THE ABOVE. | | | 240.4,310.16, 680.20, 215.5, 215.3,230.42 ETC. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-11-04 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-11-04 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2006-11-04 10:08:43 | SEPERATE GAS PLANS AND PERMIT REQUIRED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-25 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-25 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2007-01-25 08:40:47 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2006-11-29 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2006-11-29 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2006-12-07 10:04:39 | TO "COMM" BD#57 | | 2006-11-29 18:04:43 | WAITING FOR "COMM" BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-07 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-10-02 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2006-10-17 13:36:52 | TO "COMM" BD#12 | | 2006-10-02 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-13 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2007-01-13 |
Time |
06:10 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2007-01-13 |
Time |
05:24 |
Sent To |
|
|
| Notes |
| 2007-01-13 06:11:31 | SEPERATE PLANS ANDPERMIT FOR GAS PIPING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-11-04 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-11-04 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2006-11-04 10:07:18 | PLUMBING REVIEW UNDER PERMIT #06071766 |
|
|