| 2006-10-19 13:54:59 | |
| | |
| | BUILDING PLAN REVIEW |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW 1ST |
| | ACTION: DENIED |
| | |
| | 1)W.P.B. AMENDMENTS.106.1.3BUILDINB PLANS SHALL |
| | BE DRAWN TO MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL |
| | PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.THE BUILDING |
| | OFFICIAL MAY ESTABLISH THROUGH DEPARTMENTAL POLICH, |
| | STANDARDS FOR PLANS AND SPECIFICATIONS, IN ORDER TO |
| | PROVIDE CONFORMITY TO ITS RECORD RETENTION PROGRAM. |
| | THE DRAWINGS SUBMITTED ARE INSUFFICENT AND REQUIRE MORE |
| | INFORMATION AND DETAILS. SHOW WHAT THE NEW ARCHES ARE |
| | MADE OF AND HOW THEY WILL BE ATTATCHED TO THE COLUMNS. |
| | THIS WORK SHALL BE DESIGNED TO THE 2004 FBC. |
| | |
| | 2) 2004 FL. BLD CODE 1603.1.4 THE |
| | FOLLOWING INFORMATION RELATED TO WIND |
| | SHALL BE SHOWN ON THE CONSTRUCTION |
| | DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | |
| | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | 4) SHOW ON THE DRAWINGS WHERE THE OLD PORCH IS AND |
| | WHERE THE NEW ADDITION WILL BE ADDED. |
| | |
| | 5) THE NEW CONCRETE AREA SHALL INDICATE THE FOOTING |
| | DETAIL IF REQUIRED AND THE THICKNESS OF THE CONCRETE |
| | PAD. |
| | |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |
| | |
| | |