Plan Review Details - Permit 06090903
Plan Review Stops For Permit 06090903
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2006-12-15 Cont ID  
Sent By lursu Date 2006-12-15 Time 09:32 Rev Time 0.00
Received By lursu Date 2006-12-15 Time 09:32 Sent To  
Notes
2006-12-15 09:32:45ADDRESS IS CORRECT.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 E-MAIL:[email protected]

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2006-10-03 Cont ID  
Sent By lursu Date 2006-10-03 Time 11:35 Rev Time 0.00
Received By lursu Date 2006-10-02 Time 16:59 Sent To  
Notes
2006-10-03 00:00:00FIELD VERIFICATION IS NECESSARY ,IS THE
 WORK DONE AT 2058 PBL BLVD .
2006-09-29 00:00:00NEEDS ADDRESSING FOR SUITES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-03-07 Cont ID  
Sent By rmcdouga Date 2007-03-07 Time 07:51 Rev Time 0.00
Received By rmcdouga Date 2007-03-07 Time 07:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-02-14 Cont ID  
Sent By rmcdouga Date 2007-02-14 Time 10:59 Rev Time 0.00
Received By rmcdouga Date 2007-02-14 Time 07:24 Sent To  
Notes
2007-02-14 12:43:44DENIED BY BUILDING
  
 1) THE NOC THAT WAS SUBMITTED HAS EXPIRED. IT WILL NEED
 TO BE RERECORDED.
  
 2) THE LIFE SAFETY SUMMARY ON 12.1 INCORRECTLY
 SPECIFIES THAT ONLY ONE EXIT IS REQUIRED. WITH AN
 OCCUPANT LOAD OF MORE THAN 50 AND/OR THE COMMON PATH OF
 TRAVEL MORE THAN 100' IF ONLY ONE EXIT, FBC 1014.1
 REQUIRES TWO EXITS. PLEASE CORRECT.
  
 3) ADDRESS COMMENTS OF OTHER TRADES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-12-15 Cont ID  
Sent By rmcdouga Date 2006-12-15 Time 07:32 Rev Time 0.00
Received By rmcdouga Date 2006-12-15 Time 07:32 Sent To  
Notes
2006-12-15 08:30:58DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE
 2004 FBC EXISTING BUILDING CODE SECTION 301.5.
  
 3) SPECIFY THE SQUARE FOOTAGE FOR THE AREA, THE
 OCCUPANT LOAD, THE NUMBER OF REQUIRED EXITS AND THE
 WIDTHS OF THE EGRESS DOORS ON THE PLANS.
  
 4)SPECIFY THE TYPE OF CONSTRUCTION BASED ON THE 2004
 FBC DESIGNATIONS ON THE PLANS. NOTE: NON-COMBUSTIBLE IS
 NOT A CONSTRUCTION TYPE. SEE FBC 602.1 BUILDINGS AND
 STRUCTURES ERECTED OR TO BE ERECTED, ALTERED OR
 EXTENDED IN HEIGHT OR AREA SHALL BE CLASSIFIED IN ONE
 OF THE FIVE CONSTRUCTION TYPES DEFINED IN SECTIONS
 602.2 THROUGH 602.5.
  
 5) PLEASE REMOVE THE OLD PLAN SHEETS AND REPLACE THEM
 WITH THE NEW ONES, MAKING TWO COMPLETE SETS. ONE SET OF
 THE OLD PLANS MARKED VOIDED CAN BE RESUBMITTED FOR
 REFERENCE TO AID IN PLAN REVIEW.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-10-02 Cont ID  
Sent By rmcdouga Date 2006-10-02 Time 14:26 Rev Time 0.00
Received By rmcdouga Date 2006-10-02 Time 14:26 Sent To  
Notes
2006-10-02 00:00:00DENIED BY BUILDING
  
 1)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SPECIFY THE LEVEL OF ALTERATION FOR
 THE PROJECT AS SPECIFIED IN CHAPTER 3 OF
 THE 2004 FBC EXISTING BUILDING CODE.
  
 3) SPECIFY THE SQUARE FOOTAGE FOR THE
 AREA, THE OCCUPANT LOAD, THE NUMBER OF
 REQUIRED EXITS, THE REQUIRED EGRESS
 WIDTH AND THE TYPE OF CONSTRUCTION BASED
 ON THE 2004 FBC DESIGNATION. SEE FBC
 602, 1004, 1005, 1008.1.1 AND 1014.1.
  
 4) SPECIFY THE LOCATION OF THE REQUIRED
 EXIT SIGNS. SEE FBC 1006.3.
  
 5) THE NEW SUITE WILL REQUIRE AN ADDRESS
 BEFORE A PERMIT CAN BE ISSUED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-03-28 Cont ID  
Sent By dpalmer Date 2007-03-28 Time 10:16 Rev Time 0.00
Received By dpalmer Date 2007-03-28 Time 10:07 Sent To  
Notes
2007-03-28 10:17:57PLANS REDLINED,
  
  
 NO NEW ELECTRICAL LIGHTING FIXTURES ARE TO BE
 INSTALLED. IF ANY NEW FIXTURES ARE INSTALLED, REVISED
 PLANS INDICATING LIGHTING LEVELS MEETING FBC 2004
 CHAPTER 13 SHALL BE MET.
 THIS IS REQUIRED TO BE REVISED BEFORE ROUGH.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-03-04 Cont ID  
Sent By dpalmer Date 2007-03-04 Time 09:09 Rev Time 0.00
Received By dpalmer Date 2007-03-04 Time 08:47 Sent To  
Notes
2007-03-04 09:14:02*** UNSAT 4TH REVIEW***
  
 *PLANS REVISED HOWEVER THERE IS INFORMATION NOT ON
 PLANS.
  
 1) NOTE: PLEASE SEE NO MAXIMUM TIMES STATED FOR OC
 DEVICES. PLEASE SEE 13-415.1ABC.1.1
 PLEASE SEE NO LIGHTING DENSITIES/CALCULATIONS OR WHAT
 TYPES OF FIXTURES ARE BEING USED TO INDICATE THIS IS
 SHOWN.
 PLEASE SEE 13-415.2
 THIS CAN NOT BE ASSUMED, INFORMATION IS NEEDED.
  
 2) NOTE: PLEASE SEE EMERGENCY LIGHTS ARE STILL NOT
 SHOWING CIRCUITING.
  
 ** PLEASE KNOW ONCE ALL REVIEWS ARE DONE AND ALL
 REVIEWS ARE OK, THEN PLEASE CALL AS A *PROVISO* MAY BE
 GRANTED FOR CONDITIONS OF PERMIT ISSUANCE.
 ALL OF THE ABOVE CAN BE REDLINED ON PLANS, HOWEVER WAS
 STATED IN PREVIOUS REVIEW NOTES FOR INFORMATION TO BE
 ON PLANS.
  
 ** IMPORTANT**
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-02-11 Cont ID  
Sent By dpalmer Date 2007-02-11 Time 11:42 Rev Time 0.00
Received By dpalmer Date 2007-02-11 Time 10:55 Sent To  
Notes
2007-02-11 11:43:57**** UNSAT 3RD REVIEW ****
  
 *** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW WHICH
 ARE IN NEED OF ADDRESSING AND SOME NEW NOTES DUE TO THE
 PLANS SUBMITTED.
  
 1) NOTE: PLEASE SEE THE SCOPE OF WORK OR NOT CLEAR AT
 THIS TIME. PLEASE SEE THE PREVIOUS REVIEW NOTES
 MENTIONED TO SUPPLY A PANEL SCHEDULE FOR NEW OR
 EXISTING CIRCUITS BEING DONE IN SCOPE OR EXISTING.
 PLEASE SEE THE PANEL SCHEDULE WHICH IS NOW BEING
 SUBMITTED MENTIONS ALL THE NEW CIRCUITS, HOWEVER PLEASE
 SEE THE PLANS DO NOT INDICATE ANY CIRCUITS FOR THESE
 NEW ITEMS.
 PLEASE SEE NOTES ON PLANS MENTIONS ALL CEILING GRID AND
 TILES BEING REMOVED, YET CEILING MOUNTED CEILING GRID
 FIXTURES ARE TO REMAIN?? PLEASE CLARIFY HOW THESE
 EXISTING FIXTURES ARE GOING TO BE USED. SOME ARE NOTED
 AS BEING NEW INDUSTRIAL TYPE FIXTURES.
 PLEASE SEE 700.12E FOR CIRCUITING OF EM/EXT LTS.
 PLEASE CLARIFY THE NEW SCOPE.
 PLEASE SEE ANY NEW ELECTRICAL WORK IS TO MEET THE NEW
 CODES FOR THAT SCOPE OF WORK. THIS IS PERMITTED UNDER
 THE 2002 NEC.
  
  
 2) NOTE: PLEASE STATE AND DESIGN TO ALL OF THE
 FOLLOWING MINIMUM CODES AT A MINIMUM FOR ELECTRICAL
 REVIEW.
 NFPA-70 2002, 2003 NFPA-101, 2004 FBC.
  
 3) NOTE: PLEASE SEE 600.5 AS THE AMPERAGE SHOWN FOR
 SIGN CIRCUIT IS 6AMPS WHICH DOES NOT MEET THE MINIMUM
 REQUIRED PER 600.5, AND 220.3(B)(6).
  
 4) NOTE: PLEASE SEE THE SEAL WHICH IS PLACED ON
 ELECTRICAL PLANS IS NO LONGER VALID TO BE USED IN THE
 STATE OF FLORIDA.
 PLEASE SEE RULE 61G15-23.001 WHICH WAS CHANGED IN FEB
 2004 WHICH REQUIRED ALL SEALS BY ENGINEERS TO USE THE
 NEW WORDING OF LICENSE. THE TIME WAS EXTENDED TO
 DECEMBER 31ST, 2005, HOWEVER ANY AND ALL DOCUMENTS
 AFTER THAT DATE MUST CONTAIN THE NEW SEALS WITH THE
 WORDING OF *LICENSE* INSTEAD OF *CERTIFICATE*. PLEASE
 KNOW THAT THIS REVIEW HAS SEEN UP DATED NEW SEALS FROM
 THIS DESIGNER AND PERHAPS AN OLDER SEAL WAS USED
 INSTEAD.
 PLEASE KNOW THAT ANY OLD SEALS PERHAPS SHOULD BE
 DISCARDED SO THIS WOULD NOT CREATE INADVERTENT USE.
  
 FS 471.025.
  
 5) NOTE: PLEASE SEE SHEETS DO NOT CONTAIN THE REQUIRED
 TITLE BLOCKS FOR THE ENGINEER OR FIRM OF RECORD AS
 REQUIRED PER FAC 61G15-23.002, FS 471.023.
 PLEASE INCLUDE AND COMPLETE.
 THIS IS REQUIRED FOR ALL TRADES WHETHER OR NOT COMMENT
 IS MADE BY OTHER REVIEWER(S).
  
 6) NOTE: PLEASE SEE FBC 2004 CHAPTER 13, PREVIOUS
 REVIEWS MENTIONS HOW COMPLIANCE IS MET AND RESPONSE
 MENTIONS TO SEE REVISED PLANS, HOWEVER PLANS DID NOT
 SEEM TO CONTAIN INFORMATION AS NEED.
 13-415.1.ABC.1.1, .1.2 AND .1.3.
 13-415.1.AB.1, 13-415.2 ETC??
  
 7) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO
 REPEAT COMMENTS FOR CODE COMPLIANCE.
  
 8) NOTE: PLEASE SEE THE RECORDED NOTICE OF COMMENCEMENT
 SUBMITTED IS NO LONGER VALID PER FS 713.13(2).
 A NEW RECORDED NOC WILL BE REQUIRED BEFORE PICKING UP
 PERMIT.
 IF WORK NOTHAS NOT COMMENCED WITHIN 90DAYS OF
 RECORDING, SUCH NOC SHALL BECOME VOID.
 *MAY RE-RECORD*
  
  
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-12-09 Cont ID  
Sent By dpalmer Date 2006-12-09 Time 17:51 Rev Time 0.00
Received By dpalmer Date 2006-12-09 Time 17:22 Sent To I
Notes
2006-12-09 17:53:46* UNSAT 2ND REVIEW**
  
 ** PLEASE SEE SOME ITEMS FORM PREVIOUS REVIEW WHICH
 STILL NEED TO BE ADDRESSED.
 PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM
 PREVIOUS REVIEW WITH AN "OK" OR "NO" DENOTING IF
 COMMENT WAS ADDRESSED AND ANY FURTHER EXPLANATION FOR
 PREVIOUS COMMENT. PLEASE ANY NOTED AS "OK/NO" MEANS
 PART OF A COMMENT MAY HAVE BEEN ADDRESSED BUT NOT ALL.
  
 1) NOTE: NO, PLEASE SEE MULTIPLE ITEMS SHOWN ON PANEL
 SCHEDULE WHICH IS NOT LOCATED ON PLANS. PLEASE SHOW
 ALL. SOME ITEMS FOR CODE COMPLIANCE VERIFICATION FOR
 LOCATION ON PLANS COULD NOT BE VERIFIED AT THIS TIME.
 ** NOTE, PLEASE KNOW THAT THE LENNY'S SUB SHOP TO DATE
 HAS STILL NOT YET "APPLIED" FOR PERMIT. THE PLANS WERE
 ONLY SUBMITTED FOR "PLAN REVIEW" ONLY. THEIR PLANS WILL
 FALL UNDER NEW REVISIONS TO THE 2004 FBC AND THE 2005
 NEC WHICH WERE ADOPTED AS OF DEC 8TH, 2006.
 PLEASE KNOW COMMENTS ON SOME ITEMS MAY BE DIFFERENT
 EVEN IF NEXT TO EACH OTHER.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE INDICATE ON PLANS THE NEW CIRCUITING FOR
 ELECTRICAL BEING SHOWN TO EXISTING PANELS.
 PLEASE SUBMIT A PANEL SCHEDULE INDICATING NEW CIRCUITS
 AND EXISTING AS THIS ONE LARGER SPACE IS BEING DIVIDED
 INTO TWO SPACES AND NEED TO VERIFY THAT ALL CIRCUITING
 FROM THE EXISTING ONE SPACE IS NOW BEING SEPARATED.
 NEED TO SHOW OR EXISTING AND NEW. NEED TO VERIFY ALL
 CIRCUITING. 240.24,110.26, 408.4, 310.16, 240.4
 ** NOTES ON PLANS MENTIONS OTHER ADJACENT SPACE UNDER
 REVIEW FOR SEPARATE
 PERMIT, HOWEVER TO THE DATE OF THIS REVIEW NO OTHER
 PERMIT HAS BEEN APPLIED FOR OR PLAN REVIEW FOR SAID
 SEPARATION OR SPACE.
  
 2) NOTE: OK,/NO, PLEASE SEE CIRCUITING NOTE ABOVE. TO
 BE COMPLETED.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE INDICATE NEW OR EXISTING EXIT /EM LTS, SINCE
 THIS IS A NEW SPACE, WHERE ARE THESE LOCATED. PLEASE
 ALSO SEE FIRE MARSHAL'S OFFICE REVIEW NOTES.
 PLEASE SEE 700.12E FOR CIRCUITING OF THESE LTS.
  
 3) NOTE: NO. PLEASE SEE THIS SPACE EVEN THOUGH IT IS
 LESS THAN 5K SQ FT IS LOCATED IN A "BUILDING" LARGER
 THEN 5K SQ FT. PLEASE SEE DEFINITIONS OF "BUILDING" AS
 STATED IN THE FBC. AS THIS SPACE DOES NOT CONTAIN THE
 RATED "FIREWALL" IN ORDER TO CONSIDER THIS SPACE A
 SEPARATE BUILDING, IT DOES FALL UNDER THE REQUIREMENTS
 FOR LIGHTING CONTROLS. PLEASE SEE SECTIONS AS NOTED
 BELOW WHICH EVEN MENTION "METERED" SPACES IN A
 BUILDING.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE FBC 2004 CHAPTER 13 AS THIS IS A NEW
 BUILD-OUT AND ALL IS NOT EXISTING, THEN PLEASE SEE
 13-415.1.ABC.1.1, .1.2 AND .1.3.
 PLEASE SEE 13-415.2, 13-415.2.ABC.1
  
 4) NOTE: OK.
 **NEW NOTE **
  
 1) NOTE: PLEASE SEE PREVIOUS NOTES AT THE END OF THE
 REVIEW NOTESWHICH REQUESTED FOR ALL OLD/VOIDED SHEETS
 TO BE REMOVED FROM SETS AND FOR NEW SHEETS TO BE
 INSERTED IN PLACE OF OLD/VOIDED SHEETS. PLEASE MAKE TWO
 COMPLETE SETS FOR REVIEW AND STAMPING. PLEASE DO NOT
 SUBMIT LOOSE SHEETS NOT IN SETS. THIS WILL HELP IN THE
 REVIEW AND PROCESSING OF PLANS.
 CONTRACTOR WILL BE CALLED IN TO DO THIS IF PLANS ARE
 NOT PLACED INTO SETS WHEN RESUBMITTING FOR THE NEXT
 REVIEW.
  
 ** PLEASE KNOW, THERE IS SOME
 INFORMATION WHICH IS NOT CLEAR AT THIS
 TIME AND NEEDS TO BE VERIFIED. PLEASE
 SEE ANY POSSIBLE NOTES FROM OTHER
 REVIEWER(S) WHICH MAY AFFECT THE
 ELECTRICAL PLANS.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
2006-12-09 17:26:28PLANS REMOVED FROM INCOMING AND WILL BE ROUTED BACK TO
 INCOMING ONCE REVIEW IS DONE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-09-29 Cont ID  
Sent By dpalmer Date 2006-09-29 Time 07:50 Rev Time 0.00
Received By dpalmer Date 2006-09-29 Time 07:32 Sent To  
Notes
2006-09-29 00:00:00** UNSAT **
  
 1) NOTE: PLEASE INDICATE ON PLANS THE
 NEW CIRCUITING FOR ELECTRICAL BEING
 SHOWN TO EXISTING PANELS.
 PLEASE SUBMIT A PANEL SCHEDULE
 INDICATING NE CIRCUITS AND EXISTING AS
 THIS ONE LARGER SPACE IS BEING DIVIDED
 INTO TWO SPACES AND NEED TO VERIFY THAT
 ALL CIRCUITING FROM THE EXISTING ONE
 SPACE IS NOW BEING SEPARATED.
 NEED TO SHOW OR EXISTIGN AND NEW. NEED
 TO VERIFY ALL CIRCUITING . 240.24,110.26,408.4,310.16,
 240.4
  
  
 ** NOTES ON PLANS MENTIONS OTHER
 ADJACENT SPACE UNDER REVIEW FOR SEPARATE
 PERMIT, HOWEVER TO THE DATE OF THIS
 REVIEW NO OTHER PERMIT HAS BEEN APPLIED
 FOR OR PLAN REVIEW FOR SAID SEPARATION
 OR SPACE.
  
 2) NOTE: PLEASE INDICATE NEW OR EXISTING
 EXIT /EM LTS, SINCE THIS IS A NEW SPACE,
 WHERE ARE THESE LOCATED. PLEASE ALSO SEE
 FIRE MARSHAL'S OFFICE REVIEW NOTES.
 PLEASE SEE 700.12E FOR CIRCUITING OF
 THESE LTS.
  
 3) NOTE: PLEASE SEE FBC 2004 CHAPTER 13
 AS OF THIS IF THIS IS NEW BUILD -OUT AND
 ALL IS NOT EXISTING, THEN PLEASE SEE 13-415.1.ABC.1.1,
 .1.2 AND .1.3,
 PLEASE SEE 13-415.2, 13-415.2.ABC.1
  
 4) NOTE: PLEASE SEE THE FOLLOWING CODES
 SHALL BE STATED ON THE PLANS AT A MIN.
 PLEASE SEE 2002 NFPA-70(NEC), 2003
 NFPA-101 (SHOWS 2000), 2002 NFPA-72
  
 ** PLEASE KNOW, THERE IS SOME
 INFORMATION WHICH IS NOT CLEAR AT THIS
 TIME AND NEEDS TO BE VERIFIED. PLEASE
 SEE ANY POSSIBLE NOTES FROM OTHER
 REVIEWER(S) WHICH MAY AFFECT THE
 ELECTRICAL PLANS.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2007-03-15 Cont ID  
Sent By mawillia Date 2007-03-15 Time 18:42 Rev Time 0.00
Received By mawillia Date 2007-03-15 Time 18:39 Sent To  
Notes
2007-03-15 18:42:08*****PROVISO*****
  
  
  
 THE APPROPIATE PLAN SHEETS WILL BE APPROVED WHEN ALL
 OTHER PLAN REVIEWS HAVE BEEN SATISFIED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-02-14 Cont ID  
Sent By mawillia Date 2007-02-14 Time 16:20 Rev Time 0.00
Received By mawillia Date 2007-02-14 Time 16:20 Sent To  
Notes
2007-02-14 16:23:15*****PROVISO*****
  
  
  
 ALL COMMENTS FROM PREVIOUS FIRE PLAN REVIEW
 (12/22/2006) HAVE BEEN ADDRESSED.THE APPROPIATE PLAN
 SHEETS WILL BE APPROVED WHEN ALL OTHER PLAN REVIEWS
 HAVE BEEN SATISFIED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-12-22 Cont ID  
Sent By mwennerg Date 2006-12-22 Time 12:01 Rev Time 0.00
Received By mwennerg Date 2006-12-22 Time 12:01 Sent To  
Notes
2006-12-22 12:02:49***DENIED***
  
 PLEASE NOTE THAT A RESPONSE LETTER WAS NOT SUBMITTED
 FOR PREVIOUS FIRE REVIEW. PLEASE SEE FOLLOWING TAKEN
 FROM FIRST REVIEW AND MAKE CORRECTIONS.
  
 1) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION.
  
 2) PLEASE SHOW ALL EXISTING AND OR NEW EXIT AND
 EMERGENCY LIGH EQUIPMENT.
  
 3) PLEASE SHOW LOCATION OF REQUIRED 2A-10B,C RATED FIRE
 EXTINGUISHERS THAT SHALL NOT BE SPACED AT DISTANCES
 EXCEEDING 75'.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-10-18 Cont ID  
Sent By mwennerg Date 2006-10-18 Time 11:04 Rev Time 0.00
Received By mwennerg Date 2006-10-18 Time 11:04 Sent To  
Notes
2006-10-18 11:08:28***DENIED***
  
 1) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION.
  
 2) PLEASE SHOW ALL EXISTING AND OR NEW EXIT AND
 EMERGENCY LIGH EQUIPMENT.
  
 3) PLEASE SHOW LOCATION OF REQUIRED 2A-10B,C RATED FIRE
 EXTINGUISHERS THAT SHALL NOT BE SPACED AT DISTANCES
 EXCEEDING 75'.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW (561) 805-6722

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-03-27 Cont ID  
Sent By spalmer Date 2007-03-27 Time 18:42 Rev Time 0.00
Received By spalmer Date 2007-03-27 Time 18:42 Sent To  
Notes
2007-03-27 18:42:39TO BOB # 11

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-03-02 Cont ID  
Sent By adarroug Date 2007-03-02 Time 15:03 Rev Time 0.00
Received By adarroug Date 2007-03-02 Time 15:01 Sent To  
Notes
2007-03-02 15:05:52TO "BOB"#18

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-08 Cont ID  
Sent By adarroug Date 2007-02-08 Time 08:27 Rev Time 0.00
Received By adarroug Date 2007-02-08 Time 08:27 Sent To  
Notes
2007-02-08 08:28:44TO "BOB"#7

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-29 Cont ID  
Sent By spalmer Date 2006-11-29 Time 19:45 Rev Time 0.00
Received By spalmer Date 2006-11-29 Time 19:45 Sent To  
Notes
2006-12-12 17:45:21TO "BOB"#13
2006-11-29 19:46:55WAITING FOR "BOB" BOARD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-23 Cont ID  
Sent By jleech Date 2006-10-23 Time 07:43 Rev Time 0.00
Received By jleech Date 2006-09-28 Time 11:09 Sent To  
Notes
2006-09-28 00:00:00WAITING FOR "BOB"
 TO "BOB"#7

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-03-29 Cont ID  
Sent By tgordon Date 2007-03-29 Time 10:37 Rev Time 0.20
Received By tgordon Date 2007-03-29 Time 10:37 Sent To  
Notes
2007-03-29 10:37:52BATHROOM EXHAUST FAN ONLY.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-03-07 Cont ID  
Sent By tgordon Date 2007-03-07 Time 11:19 Rev Time 0.20
Received By tgordon Date 2007-03-07 Time 11:19 Sent To  
Notes
2007-03-07 11:20:18BATHROOM EXHAUST FAN ONLY.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-02-13 Cont ID  
Sent By tgordon Date 2007-02-13 Time 10:01 Rev Time 0.20
Received By tgordon Date 2007-02-13 Time 10:01 Sent To  
Notes
2007-02-13 10:03:14*** DENIED ***
 1) SEE ELECTRICAL REVIEW NOTE #4, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-10-03 Cont ID  
Sent By tgordon Date 2006-10-03 Time 09:44 Rev Time 0.25
Received By tgordon Date 2006-10-03 Time 09:44 Sent To  
Notes
2006-10-03 00:00:00FOR BATHROOM EXHAUST FAN ONLY.

Review Stop P PLUMBING
Rev No 6 Status P Date 2007-03-30 Cont ID  
Sent By jleech Date 2007-03-30 Time 09:48 Rev Time 0.00
Received By jleech Date 2007-03-30 Time 09:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-03-10 Cont ID  
Sent By jleech Date 2007-03-10 Time 08:20 Rev Time 0.00
Received By jleech Date 2007-03-10 Time 08:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-02-12 Cont ID  
Sent By jleech Date 2007-02-12 Time 15:02 Rev Time 0.00
Received By jleech Date 2007-02-12 Time 15:02 Sent To  
Notes
2007-02-12 15:22:21DENIED;
 FBC-2004 PLUMBING CODE TABLE REQUIRES A DRINKING
 FOUNTAIN. SECTION 410 ALLOWS WATER COOLERS TO
 SUBSTITUED FOR NOT MORE THAN 50% OF THE DRINKING
 FOUNTAIN, SO THE BOTTLED WATER COOLER SHOWN ON PLAN
 MUST BE CHANGED TO A DRINKING FOUNTAIN. PLEASE SHOW ON
 FLOOR PLAN AND PLUMBING RISERS. ALSO SHOW A DETAIL TO
 SHOW COMPLIANCE TO CHAPTER 11 OF THE BUILDING CODE.
 SECTIONS 11-4.1.3(10)AND SECTIONS 11-4.15.2 SPOUT
 HEIGHT 11-4.15.3 SPOUT LOCATION, 11-4.15.4 CONTROLS,
 AND 11-4.15.5 CLEARANCES.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-01-03 Cont ID  
Sent By jleech Date 2007-01-03 Time 14:31 Rev Time 0.00
Received By jleech Date 2007-01-03 Time 14:31 Sent To  
Notes
2007-01-03 14:45:35DENIED;
 SECOND REVIEW SAME COMMENTS;
 1. SHOW ON PLANS; SQ. FOOTAGE OF SPACE, NUMBER OF
 EMPLOYEES, SANITARY RISER DIAGRAM, AND WATER RISER
 DIAGRAM.
 2. SHOW DETAIL OF BATHROOM, TO COMPLY WITH FLORIDA
 HANDICAP CODESECTION 11-4.16.2 THRU 11-4.16.6 FOR
 TOILET AND 11-4.19.2 THRU 11-4.19.6 FOR LAVATORY. 3.
 THE TOILET SHALL BE LOCATED IN THE CORNER DIAGONAL TO
 DOOR.
 4. DRINKING FOUNTAIN REQUIRED, SEE FBC-2004 PLUMBING
 TABLE 403.1(6M) MINIMUM PLUMBING FIXTURES REQUIRED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-10-23 Cont ID  
Sent By jleech Date 2006-10-23 Time 07:18 Rev Time 0.00
Received By jleech Date 2006-10-23 Time 07:18 Sent To  
Notes
2006-10-23 07:42:05DENIED;
 1. PLEASE PROVIDE THE FOLLOWING INFORMATION;
 A) SQ. FOOTAGE OF SPACE .
 B) NUMBER OF EMPLOYEES
 C) CARRY OUT OR DINE IN, HOW MANY SEATS?
 D) SANITARY RISER DIAGRAM REQUIRED.
 E) SURCE OF WATER
 F) TYPE OF PIPING MATERIAL TO BE USED WATER AND
 SANITARY.
 G) SEWER TIE IN.
 2. ADA BATHROOM; SHOW MIN. DISTANCE OF WALL FOR
 LAVATORY. 15"
 3. THE WATER CLOSET SHALL BE LOCATED IN THE CORNER
 DIAGONAL TO THE DOOR.
 SEE FIGURE 30E FBC-2004 CHAPTER 11.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695


Account Summary | Usage Policy | Privacy Policy