| Plan Review Stops For Permit 06090903 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-15 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-12-15 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2006-12-15 09:32:45 | ADDRESS IS CORRECT. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-10-03 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-10-02 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | FIELD VERIFICATION IS NECESSARY ,IS THE | | | WORK DONE AT 2058 PBL BLVD . | | 2006-09-29 00:00:00 | NEEDS ADDRESSING FOR SUITES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-07 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-07 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-14 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-14 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2007-02-14 12:43:44 | DENIED BY BUILDING | | | | | | 1) THE NOC THAT WAS SUBMITTED HAS EXPIRED. IT WILL NEED | | | TO BE RERECORDED. | | | | | | 2) THE LIFE SAFETY SUMMARY ON 12.1 INCORRECTLY | | | SPECIFIES THAT ONLY ONE EXIT IS REQUIRED. WITH AN | | | OCCUPANT LOAD OF MORE THAN 50 AND/OR THE COMMON PATH OF | | | TRAVEL MORE THAN 100' IF ONLY ONE EXIT, FBC 1014.1 | | | REQUIRES TWO EXITS. PLEASE CORRECT. | | | | | | 3) ADDRESS COMMENTS OF OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-15 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-15 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2006-12-15 08:30:58 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE | | | 2004 FBC EXISTING BUILDING CODE SECTION 301.5. | | | | | | 3) SPECIFY THE SQUARE FOOTAGE FOR THE AREA, THE | | | OCCUPANT LOAD, THE NUMBER OF REQUIRED EXITS AND THE | | | WIDTHS OF THE EGRESS DOORS ON THE PLANS. | | | | | | 4)SPECIFY THE TYPE OF CONSTRUCTION BASED ON THE 2004 | | | FBC DESIGNATIONS ON THE PLANS. NOTE: NON-COMBUSTIBLE IS | | | NOT A CONSTRUCTION TYPE. SEE FBC 602.1 BUILDINGS AND | | | STRUCTURES ERECTED OR TO BE ERECTED, ALTERED OR | | | EXTENDED IN HEIGHT OR AREA SHALL BE CLASSIFIED IN ONE | | | OF THE FIVE CONSTRUCTION TYPES DEFINED IN SECTIONS | | | 602.2 THROUGH 602.5. | | | | | | 5) PLEASE REMOVE THE OLD PLAN SHEETS AND REPLACE THEM | | | WITH THE NEW ONES, MAKING TWO COMPLETE SETS. ONE SET OF | | | THE OLD PLANS MARKED VOIDED CAN BE RESUBMITTED FOR | | | REFERENCE TO AID IN PLAN REVIEW. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-10-02 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-10-02 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | DENIED BY BUILDING | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE LEVEL OF ALTERATION FOR | | | THE PROJECT AS SPECIFIED IN CHAPTER 3 OF | | | THE 2004 FBC EXISTING BUILDING CODE. | | | | | | 3) SPECIFY THE SQUARE FOOTAGE FOR THE | | | AREA, THE OCCUPANT LOAD, THE NUMBER OF | | | REQUIRED EXITS, THE REQUIRED EGRESS | | | WIDTH AND THE TYPE OF CONSTRUCTION BASED | | | ON THE 2004 FBC DESIGNATION. SEE FBC | | | 602, 1004, 1005, 1008.1.1 AND 1014.1. | | | | | | 4) SPECIFY THE LOCATION OF THE REQUIRED | | | EXIT SIGNS. SEE FBC 1006.3. | | | | | | 5) THE NEW SUITE WILL REQUIRE AN ADDRESS | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-28 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-28 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2007-03-28 10:17:57 | PLANS REDLINED, | | | | | | | | | NO NEW ELECTRICAL LIGHTING FIXTURES ARE TO BE | | | INSTALLED. IF ANY NEW FIXTURES ARE INSTALLED, REVISED | | | PLANS INDICATING LIGHTING LEVELS MEETING FBC 2004 | | | CHAPTER 13 SHALL BE MET. | | | THIS IS REQUIRED TO BE REVISED BEFORE ROUGH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-04 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-04 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2007-03-04 09:14:02 | *** UNSAT 4TH REVIEW*** | | | | | | *PLANS REVISED HOWEVER THERE IS INFORMATION NOT ON | | | PLANS. | | | | | | 1) NOTE: PLEASE SEE NO MAXIMUM TIMES STATED FOR OC | | | DEVICES. PLEASE SEE 13-415.1ABC.1.1 | | | PLEASE SEE NO LIGHTING DENSITIES/CALCULATIONS OR WHAT | | | TYPES OF FIXTURES ARE BEING USED TO INDICATE THIS IS | | | SHOWN. | | | PLEASE SEE 13-415.2 | | | THIS CAN NOT BE ASSUMED, INFORMATION IS NEEDED. | | | | | | 2) NOTE: PLEASE SEE EMERGENCY LIGHTS ARE STILL NOT | | | SHOWING CIRCUITING. | | | | | | ** PLEASE KNOW ONCE ALL REVIEWS ARE DONE AND ALL | | | REVIEWS ARE OK, THEN PLEASE CALL AS A *PROVISO* MAY BE | | | GRANTED FOR CONDITIONS OF PERMIT ISSUANCE. | | | ALL OF THE ABOVE CAN BE REDLINED ON PLANS, HOWEVER WAS | | | STATED IN PREVIOUS REVIEW NOTES FOR INFORMATION TO BE | | | ON PLANS. | | | | | | ** IMPORTANT** | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-11 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-11 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2007-02-11 11:43:57 | **** UNSAT 3RD REVIEW **** | | | | | | *** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW WHICH | | | ARE IN NEED OF ADDRESSING AND SOME NEW NOTES DUE TO THE | | | PLANS SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE THE SCOPE OF WORK OR NOT CLEAR AT | | | THIS TIME. PLEASE SEE THE PREVIOUS REVIEW NOTES | | | MENTIONED TO SUPPLY A PANEL SCHEDULE FOR NEW OR | | | EXISTING CIRCUITS BEING DONE IN SCOPE OR EXISTING. | | | PLEASE SEE THE PANEL SCHEDULE WHICH IS NOW BEING | | | SUBMITTED MENTIONS ALL THE NEW CIRCUITS, HOWEVER PLEASE | | | SEE THE PLANS DO NOT INDICATE ANY CIRCUITS FOR THESE | | | NEW ITEMS. | | | PLEASE SEE NOTES ON PLANS MENTIONS ALL CEILING GRID AND | | | TILES BEING REMOVED, YET CEILING MOUNTED CEILING GRID | | | FIXTURES ARE TO REMAIN?? PLEASE CLARIFY HOW THESE | | | EXISTING FIXTURES ARE GOING TO BE USED. SOME ARE NOTED | | | AS BEING NEW INDUSTRIAL TYPE FIXTURES. | | | PLEASE SEE 700.12E FOR CIRCUITING OF EM/EXT LTS. | | | PLEASE CLARIFY THE NEW SCOPE. | | | PLEASE SEE ANY NEW ELECTRICAL WORK IS TO MEET THE NEW | | | CODES FOR THAT SCOPE OF WORK. THIS IS PERMITTED UNDER | | | THE 2002 NEC. | | | | | | | | | 2) NOTE: PLEASE STATE AND DESIGN TO ALL OF THE | | | FOLLOWING MINIMUM CODES AT A MINIMUM FOR ELECTRICAL | | | REVIEW. | | | NFPA-70 2002, 2003 NFPA-101, 2004 FBC. | | | | | | 3) NOTE: PLEASE SEE 600.5 AS THE AMPERAGE SHOWN FOR | | | SIGN CIRCUIT IS 6AMPS WHICH DOES NOT MEET THE MINIMUM | | | REQUIRED PER 600.5, AND 220.3(B)(6). | | | | | | 4) NOTE: PLEASE SEE THE SEAL WHICH IS PLACED ON | | | ELECTRICAL PLANS IS NO LONGER VALID TO BE USED IN THE | | | STATE OF FLORIDA. | | | PLEASE SEE RULE 61G15-23.001 WHICH WAS CHANGED IN FEB | | | 2004 WHICH REQUIRED ALL SEALS BY ENGINEERS TO USE THE | | | NEW WORDING OF LICENSE. THE TIME WAS EXTENDED TO | | | DECEMBER 31ST, 2005, HOWEVER ANY AND ALL DOCUMENTS | | | AFTER THAT DATE MUST CONTAIN THE NEW SEALS WITH THE | | | WORDING OF *LICENSE* INSTEAD OF *CERTIFICATE*. PLEASE | | | KNOW THAT THIS REVIEW HAS SEEN UP DATED NEW SEALS FROM | | | THIS DESIGNER AND PERHAPS AN OLDER SEAL WAS USED | | | INSTEAD. | | | PLEASE KNOW THAT ANY OLD SEALS PERHAPS SHOULD BE | | | DISCARDED SO THIS WOULD NOT CREATE INADVERTENT USE. | | | | | | FS 471.025. | | | | | | 5) NOTE: PLEASE SEE SHEETS DO NOT CONTAIN THE REQUIRED | | | TITLE BLOCKS FOR THE ENGINEER OR FIRM OF RECORD AS | | | REQUIRED PER FAC 61G15-23.002, FS 471.023. | | | PLEASE INCLUDE AND COMPLETE. | | | THIS IS REQUIRED FOR ALL TRADES WHETHER OR NOT COMMENT | | | IS MADE BY OTHER REVIEWER(S). | | | | | | 6) NOTE: PLEASE SEE FBC 2004 CHAPTER 13, PREVIOUS | | | REVIEWS MENTIONS HOW COMPLIANCE IS MET AND RESPONSE | | | MENTIONS TO SEE REVISED PLANS, HOWEVER PLANS DID NOT | | | SEEM TO CONTAIN INFORMATION AS NEED. | | | 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | 13-415.1.AB.1, 13-415.2 ETC?? | | | | | | 7) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | | | | | 8) NOTE: PLEASE SEE THE RECORDED NOTICE OF COMMENCEMENT | | | SUBMITTED IS NO LONGER VALID PER FS 713.13(2). | | | A NEW RECORDED NOC WILL BE REQUIRED BEFORE PICKING UP | | | PERMIT. | | | IF WORK NOTHAS NOT COMMENCED WITHIN 90DAYS OF | | | RECORDING, SUCH NOC SHALL BECOME VOID. | | | *MAY RE-RECORD* | | | | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-09 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-09 |
Time |
17:22 |
Sent To |
I |
|
| Notes |
| 2006-12-09 17:53:46 | * UNSAT 2ND REVIEW** | | | | | | ** PLEASE SEE SOME ITEMS FORM PREVIOUS REVIEW WHICH | | | STILL NEED TO BE ADDRESSED. | | | PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH AN "OK" OR "NO" DENOTING IF | | | COMMENT WAS ADDRESSED AND ANY FURTHER EXPLANATION FOR | | | PREVIOUS COMMENT. PLEASE ANY NOTED AS "OK/NO" MEANS | | | PART OF A COMMENT MAY HAVE BEEN ADDRESSED BUT NOT ALL. | | | | | | 1) NOTE: NO, PLEASE SEE MULTIPLE ITEMS SHOWN ON PANEL | | | SCHEDULE WHICH IS NOT LOCATED ON PLANS. PLEASE SHOW | | | ALL. SOME ITEMS FOR CODE COMPLIANCE VERIFICATION FOR | | | LOCATION ON PLANS COULD NOT BE VERIFIED AT THIS TIME. | | | ** NOTE, PLEASE KNOW THAT THE LENNY'S SUB SHOP TO DATE | | | HAS STILL NOT YET "APPLIED" FOR PERMIT. THE PLANS WERE | | | ONLY SUBMITTED FOR "PLAN REVIEW" ONLY. THEIR PLANS WILL | | | FALL UNDER NEW REVISIONS TO THE 2004 FBC AND THE 2005 | | | NEC WHICH WERE ADOPTED AS OF DEC 8TH, 2006. | | | PLEASE KNOW COMMENTS ON SOME ITEMS MAY BE DIFFERENT | | | EVEN IF NEXT TO EACH OTHER. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE ON PLANS THE NEW CIRCUITING FOR | | | ELECTRICAL BEING SHOWN TO EXISTING PANELS. | | | PLEASE SUBMIT A PANEL SCHEDULE INDICATING NEW CIRCUITS | | | AND EXISTING AS THIS ONE LARGER SPACE IS BEING DIVIDED | | | INTO TWO SPACES AND NEED TO VERIFY THAT ALL CIRCUITING | | | FROM THE EXISTING ONE SPACE IS NOW BEING SEPARATED. | | | NEED TO SHOW OR EXISTING AND NEW. NEED TO VERIFY ALL | | | CIRCUITING. 240.24,110.26, 408.4, 310.16, 240.4 | | | ** NOTES ON PLANS MENTIONS OTHER ADJACENT SPACE UNDER | | | REVIEW FOR SEPARATE | | | PERMIT, HOWEVER TO THE DATE OF THIS REVIEW NO OTHER | | | PERMIT HAS BEEN APPLIED FOR OR PLAN REVIEW FOR SAID | | | SEPARATION OR SPACE. | | | | | | 2) NOTE: OK,/NO, PLEASE SEE CIRCUITING NOTE ABOVE. TO | | | BE COMPLETED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE NEW OR EXISTING EXIT /EM LTS, SINCE | | | THIS IS A NEW SPACE, WHERE ARE THESE LOCATED. PLEASE | | | ALSO SEE FIRE MARSHAL'S OFFICE REVIEW NOTES. | | | PLEASE SEE 700.12E FOR CIRCUITING OF THESE LTS. | | | | | | 3) NOTE: NO. PLEASE SEE THIS SPACE EVEN THOUGH IT IS | | | LESS THAN 5K SQ FT IS LOCATED IN A "BUILDING" LARGER | | | THEN 5K SQ FT. PLEASE SEE DEFINITIONS OF "BUILDING" AS | | | STATED IN THE FBC. AS THIS SPACE DOES NOT CONTAIN THE | | | RATED "FIREWALL" IN ORDER TO CONSIDER THIS SPACE A | | | SEPARATE BUILDING, IT DOES FALL UNDER THE REQUIREMENTS | | | FOR LIGHTING CONTROLS. PLEASE SEE SECTIONS AS NOTED | | | BELOW WHICH EVEN MENTION "METERED" SPACES IN A | | | BUILDING. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FBC 2004 CHAPTER 13 AS THIS IS A NEW | | | BUILD-OUT AND ALL IS NOT EXISTING, THEN PLEASE SEE | | | 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE 13-415.2, 13-415.2.ABC.1 | | | | | | 4) NOTE: OK. | | | **NEW NOTE ** | | | | | | 1) NOTE: PLEASE SEE PREVIOUS NOTES AT THE END OF THE | | | REVIEW NOTESWHICH REQUESTED FOR ALL OLD/VOIDED SHEETS | | | TO BE REMOVED FROM SETS AND FOR NEW SHEETS TO BE | | | INSERTED IN PLACE OF OLD/VOIDED SHEETS. PLEASE MAKE TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. PLEASE DO NOT | | | SUBMIT LOOSE SHEETS NOT IN SETS. THIS WILL HELP IN THE | | | REVIEW AND PROCESSING OF PLANS. | | | CONTRACTOR WILL BE CALLED IN TO DO THIS IF PLANS ARE | | | NOT PLACED INTO SETS WHEN RESUBMITTING FOR THE NEXT | | | REVIEW. | | | | | | ** PLEASE KNOW, THERE IS SOME | | | INFORMATION WHICH IS NOT CLEAR AT THIS | | | TIME AND NEEDS TO BE VERIFIED. PLEASE | | | SEE ANY POSSIBLE NOTES FROM OTHER | | | REVIEWER(S) WHICH MAY AFFECT THE | | | ELECTRICAL PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-12-09 17:26:28 | PLANS REMOVED FROM INCOMING AND WILL BE ROUTED BACK TO | | | INCOMING ONCE REVIEW IS DONE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-29 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-29 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2006-09-29 00:00:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE INDICATE ON PLANS THE | | | NEW CIRCUITING FOR ELECTRICAL BEING | | | SHOWN TO EXISTING PANELS. | | | PLEASE SUBMIT A PANEL SCHEDULE | | | INDICATING NE CIRCUITS AND EXISTING AS | | | THIS ONE LARGER SPACE IS BEING DIVIDED | | | INTO TWO SPACES AND NEED TO VERIFY THAT | | | ALL CIRCUITING FROM THE EXISTING ONE | | | SPACE IS NOW BEING SEPARATED. | | | NEED TO SHOW OR EXISTIGN AND NEW. NEED | | | TO VERIFY ALL CIRCUITING . 240.24,110.26,408.4,310.16, | | | 240.4 | | | | | | | | | ** NOTES ON PLANS MENTIONS OTHER | | | ADJACENT SPACE UNDER REVIEW FOR SEPARATE | | | PERMIT, HOWEVER TO THE DATE OF THIS | | | REVIEW NO OTHER PERMIT HAS BEEN APPLIED | | | FOR OR PLAN REVIEW FOR SAID SEPARATION | | | OR SPACE. | | | | | | 2) NOTE: PLEASE INDICATE NEW OR EXISTING | | | EXIT /EM LTS, SINCE THIS IS A NEW SPACE, | | | WHERE ARE THESE LOCATED. PLEASE ALSO SEE | | | FIRE MARSHAL'S OFFICE REVIEW NOTES. | | | PLEASE SEE 700.12E FOR CIRCUITING OF | | | THESE LTS. | | | | | | 3) NOTE: PLEASE SEE FBC 2004 CHAPTER 13 | | | AS OF THIS IF THIS IS NEW BUILD -OUT AND | | | ALL IS NOT EXISTING, THEN PLEASE SEE 13-415.1.ABC.1.1, | | | .1.2 AND .1.3, | | | PLEASE SEE 13-415.2, 13-415.2.ABC.1 | | | | | | 4) NOTE: PLEASE SEE THE FOLLOWING CODES | | | SHALL BE STATED ON THE PLANS AT A MIN. | | | PLEASE SEE 2002 NFPA-70(NEC), 2003 | | | NFPA-101 (SHOWS 2000), 2002 NFPA-72 | | | | | | ** PLEASE KNOW, THERE IS SOME | | | INFORMATION WHICH IS NOT CLEAR AT THIS | | | TIME AND NEEDS TO BE VERIFIED. PLEASE | | | SEE ANY POSSIBLE NOTES FROM OTHER | | | REVIEWER(S) WHICH MAY AFFECT THE | | | ELECTRICAL PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-15 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-15 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2007-03-15 18:42:08 | *****PROVISO***** | | | | | | | | | | | | THE APPROPIATE PLAN SHEETS WILL BE APPROVED WHEN ALL | | | OTHER PLAN REVIEWS HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-14 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-14 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2007-02-14 16:23:15 | *****PROVISO***** | | | | | | | | | | | | ALL COMMENTS FROM PREVIOUS FIRE PLAN REVIEW | | | (12/22/2006) HAVE BEEN ADDRESSED.THE APPROPIATE PLAN | | | SHEETS WILL BE APPROVED WHEN ALL OTHER PLAN REVIEWS | | | HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-12-22 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-12-22 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2006-12-22 12:02:49 | ***DENIED*** | | | | | | PLEASE NOTE THAT A RESPONSE LETTER WAS NOT SUBMITTED | | | FOR PREVIOUS FIRE REVIEW. PLEASE SEE FOLLOWING TAKEN | | | FROM FIRST REVIEW AND MAKE CORRECTIONS. | | | | | | 1) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION. | | | | | | 2) PLEASE SHOW ALL EXISTING AND OR NEW EXIT AND | | | EMERGENCY LIGH EQUIPMENT. | | | | | | 3) PLEASE SHOW LOCATION OF REQUIRED 2A-10B,C RATED FIRE | | | EXTINGUISHERS THAT SHALL NOT BE SPACED AT DISTANCES | | | EXCEEDING 75'. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-18 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-10-18 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2006-10-18 11:08:28 | ***DENIED*** | | | | | | 1) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION. | | | | | | 2) PLEASE SHOW ALL EXISTING AND OR NEW EXIT AND | | | EMERGENCY LIGH EQUIPMENT. | | | | | | 3) PLEASE SHOW LOCATION OF REQUIRED 2A-10B,C RATED FIRE | | | EXTINGUISHERS THAT SHALL NOT BE SPACED AT DISTANCES | | | EXCEEDING 75'. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-03-27 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-03-27 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2007-03-27 18:42:39 | TO BOB # 11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-02 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-02 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2007-03-02 15:05:52 | TO "BOB"#18 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-08 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-08 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2007-02-08 08:28:44 | TO "BOB"#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2006-11-29 |
Time |
19:45 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2006-11-29 |
Time |
19:45 |
Sent To |
|
|
| Notes |
| 2006-12-12 17:45:21 | TO "BOB"#13 | | 2006-11-29 19:46:55 | WAITING FOR "BOB" BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-23 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-28 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2006-09-28 00:00:00 | WAITING FOR "BOB" | | | TO "BOB"#7 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-29 |
Time |
10:37 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-03-29 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2007-03-29 10:37:52 | BATHROOM EXHAUST FAN ONLY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-07 |
Time |
11:19 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-03-07 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2007-03-07 11:20:18 | BATHROOM EXHAUST FAN ONLY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-13 |
Time |
10:01 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-02-13 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2007-02-13 10:03:14 | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE #4, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-03 |
Time |
09:44 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-10-03 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | FOR BATHROOM EXHAUST FAN ONLY. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2007-03-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-30 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-30 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-10 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-10 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-12 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-12 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2007-02-12 15:22:21 | DENIED; | | | FBC-2004 PLUMBING CODE TABLE REQUIRES A DRINKING | | | FOUNTAIN. SECTION 410 ALLOWS WATER COOLERS TO | | | SUBSTITUED FOR NOT MORE THAN 50% OF THE DRINKING | | | FOUNTAIN, SO THE BOTTLED WATER COOLER SHOWN ON PLAN | | | MUST BE CHANGED TO A DRINKING FOUNTAIN. PLEASE SHOW ON | | | FLOOR PLAN AND PLUMBING RISERS. ALSO SHOW A DETAIL TO | | | SHOW COMPLIANCE TO CHAPTER 11 OF THE BUILDING CODE. | | | SECTIONS 11-4.1.3(10)AND SECTIONS 11-4.15.2 SPOUT | | | HEIGHT 11-4.15.3 SPOUT LOCATION, 11-4.15.4 CONTROLS, | | | AND 11-4.15.5 CLEARANCES. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-01-03 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-01-03 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2007-01-03 14:45:35 | DENIED; | | | SECOND REVIEW SAME COMMENTS; | | | 1. SHOW ON PLANS; SQ. FOOTAGE OF SPACE, NUMBER OF | | | EMPLOYEES, SANITARY RISER DIAGRAM, AND WATER RISER | | | DIAGRAM. | | | 2. SHOW DETAIL OF BATHROOM, TO COMPLY WITH FLORIDA | | | HANDICAP CODESECTION 11-4.16.2 THRU 11-4.16.6 FOR | | | TOILET AND 11-4.19.2 THRU 11-4.19.6 FOR LAVATORY. 3. | | | THE TOILET SHALL BE LOCATED IN THE CORNER DIAGONAL TO | | | DOOR. | | | 4. DRINKING FOUNTAIN REQUIRED, SEE FBC-2004 PLUMBING | | | TABLE 403.1(6M) MINIMUM PLUMBING FIXTURES REQUIRED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-23 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-23 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2006-10-23 07:42:05 | DENIED; | | | 1. PLEASE PROVIDE THE FOLLOWING INFORMATION; | | | A) SQ. FOOTAGE OF SPACE . | | | B) NUMBER OF EMPLOYEES | | | C) CARRY OUT OR DINE IN, HOW MANY SEATS? | | | D) SANITARY RISER DIAGRAM REQUIRED. | | | E) SURCE OF WATER | | | F) TYPE OF PIPING MATERIAL TO BE USED WATER AND | | | SANITARY. | | | G) SEWER TIE IN. | | | 2. ADA BATHROOM; SHOW MIN. DISTANCE OF WALL FOR | | | LAVATORY. 15" | | | 3. THE WATER CLOSET SHALL BE LOCATED IN THE CORNER | | | DIAGONAL TO THE DOOR. | | | SEE FIGURE 30E FBC-2004 CHAPTER 11. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|