Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-11-09 Cont ID  
Sent By alange Date 2006-11-09 Time 11:29 Rev Time 0.00
Received By alange Date 2006-11-09 Time 11:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-10-19 Cont ID  
Sent By alange Date 2006-10-19 Time 14:38 Rev Time 0.00
Received By alange Date 2006-10-19 Time 14:38 Sent To  
Notes
2006-10-19 14:43:02DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT SET OF
 PLANS MUST BE STAMPED BY THAT OFFICE,
 AND A COPY OF THE PAID RECEIPT ATTACHED
 TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025
 FOR MORE INFORMATION.
  
 NEW COMMENT:
 A.SELECT THE ASSEMBLY USED WITH THE MULE-HIDE
 ROOFING.SHOW ON PRODUCT APPROVAL.ALSO MAKE SPECIAL
 NOTE OF GENERAL LIMITATION NUMBER 7 ON PAGE 43.
 ENGINEERED CALCULATIONS MAY BE REQUIRED FOR THE
 INHANCED FASTENING REQUIRED.
  
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-09-29 Cont ID  
Sent By alange Date 2006-09-29 Time 09:39 Rev Time 1.50
Received By alange Date 2006-09-29 Time 09:39 Sent To  
Notes
2006-09-29 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT SET OF
 PLANS MUST BE STAMPED BY THAT OFFICE,
 AND A COPY OF THE PAID RECEIPT ATTACHED
 TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025
 FOR MORE INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO
 $8,222.ADDITIONAL PERMIT FEES ARE DUE.
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC.
  
 5.PRODUCT APPROVALS REQUIRED FOR
 WINDOWS, IMPACT PROTECTION, ROOFING AND
 HARDIE PLANK SIDING AND STRAPS AND
 TIE-DOWNS.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT A ROOF SHEATHING NAILING
 SCHEDULE.
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 10.SHOW SPACING FOR FASTENERS ON
 LEDGER DETAIL.
  
 11.SHOW CEILING HEIGHT COMPLYING WITH
 R-305.
  
 12.DESIGN PARAMETERS SHOULD BE
 DESIGNED TO ASCE-7-02.
  
 13.SHOW EXISTING WINDOWS IN BEDROOM
 INCLUDING SIZES AND TYPE AND SILL HEIGHT
 SO THAT EMERGENCY ESCAPE AND RESCUE
 OPENING SIZES CAN BE VARIFIED R-310.
  
 14.PROTECTION AGAINS DECAY R 319
 1.WOOD JOISTS OR THE BOTTOM OF A
 WOOD STRUCTURAL FLOOR WHEN CLOSER THAN
 18 INCHES OR WOOD GIRDERS WHEN CLOSER
 THAN 12 INCHES TO THE EXPOSED GROUND IN
 CRAWL SPACES OR UNEXCAVATED AREA LOCATED
 WITHIN THE PERIPHERY OF THE BUILDING
 FOUNDATION.
 2.ALL WOOD FRAMING MEMBERS THAT
 REST ON CONCRETE OR MASONRY EXTERIOR
 FOUNDATION WALLS AND ARE LESS THAN 8
 INCHES FROM THE EXPOSED GROUND.
 5.WOOD SIDING, SHEATHING AND WALL
 FRAMING ON THE EXTERIOR OF A BUILDING
 HAVING A CLEARANCE OF LESS THAN 6 INCHES
 FROM THE GROUND.
  
 NOTE;FOOTING THICKNESS OF 6" AND
 FOOTING DEPTH OF 12" BELOW GRADE ARE
 BOTH AT THE MINIMUM REQUIRED BY CODE.
 JUST A NOTE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-09-28 Cont ID  
Sent By btrobaug Date 2006-09-28 Time 07:27 Rev Time 0.25
Received By btrobaug Date 2006-09-28 Time 07:27 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-14 Cont ID  
Sent By adarroug Date 2006-10-14 Time 16:20 Rev Time 0.00
Received By adarroug Date 2006-10-14 Time 16:20 Sent To B
Notes
2006-10-14 16:20:40TO "ALANGE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-10 Cont ID  
Sent By adarroug Date 2006-10-10 Time 08:39 Rev Time 0.00
Received By adarroug Date 2006-10-10 Time 08:39 Sent To Z
Notes
2006-10-10 08:39:42TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-09-29 Cont ID  
Sent By alange Date 2006-09-29 Time 09:56 Rev Time 0.00
Received By alange Date 2006-09-26 Time 14:32 Sent To  
Notes
2006-09-26 00:00:00TO "E" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2006-10-16 Cont ID  
Sent By adavila Date 2006-10-16 Time 09:57 Rev Time 0.00
Received By adavila Date 2006-10-16 Time 09:57 Sent To  
Notes
2006-10-16 09:57:5010/16/06 - PLANNING AND ZONING ***PASSED***
2006-10-12 15:07:00ZONING REVIEWED ON THE 12TH.WAITING FOR ADDITIONAL
 INFORMATION.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-09-23 Cont ID  
Sent By mmclean Date 2006-09-23 Time 14:49 Rev Time 0.00
Received By mmclean Date 2006-09-23 Time 14:49 Sent To I
Notes
2006-09-23 00:00:00DENIED,
 1. PLEASE SHOW THE PROPOSED WORK ON TWO
 COPY OF CURRENT SURVEY WITH SETBACKS
 FROM SIDE PROPERTY LINE.
 2. ONE SURVEY SHOWS THE WORK, BUT CANNOT
 BE MARKED WITH PENCIL.
 CITY OF WEST PALM - AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION: BUILDING PLANS SHALL BE
 DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER
 ACCEPTABLE MEDIUM. THE BUILDING OFFICAL
 MAY ESTABLISH THROUGH DEPARTMENTAL
 POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROIVDE
 CONFORMITY TO ITS RECORD RETENTION
 PROGRAM.THIS POLICY MAY INCLUDE SUCH
 THINDS AS MINIMUM SIZE, SHAPE, CONTRAST,
 CLARITY, OR OTHER ITEMS RELATED TO
 RECORDS MANAGEMENT.
  
 NOTE: SEC 94-305 BAY WINDOWS, CANNOT
 PROJECT NO MORE THAN 18 INCHES INTO ANY
 SIDE SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  