| Plan Review Stops For Permit 06090712 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-06 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-12-06 |
Time |
13:01 |
Sent To |
PC |
|
| Notes |
| 2006-12-06 13:02:31 | PERMIT APPLICATION AND SITE PLAN MATCH , THE UNIT IS | | | 275 .EXTENSION WAS UPDATE FROM 210 TO 275 | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | E-MAIL:[email protected] | | 2006-10-22 14:59:16 | NOW PLANS INDICATE SUITE #275, YET APPLIED FOR 210?\ | | | PLEASE SEE ADDRESSING REVIEWERS NOTES. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-10-04 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-10-04 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2006-10-04 00:00:00 | EXT#0006 WAS CREATED FOR THIS UNIT 210 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-27 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-27 |
Time |
18:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-12 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-12 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2007-02-12 13:18:34 | DENIED BY BUILDING | | | | | | REVISED SHEET G-001 IS OKAY. THE REVISION TO LIFE | | | SAFETY PLAN G-002 SHOWS WORK IN PHASE II, WHICH WAS NOT | | | INCLUDED IN THE SCOPE OF WORK FOR THIS PERMIT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-12 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-12 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2007-02-12 11:53:12 | REVISED SHEET A 103 IS OK. | | | HOWEVER, SHEET G-001 IS DENIED. WHITE- OUT HAS BEEN | | | USED TO MAKE CHANGES TO SEALED PLANS. THIS IS NOT | | | ALLOWED BY FS 481. SUBMIT REVISED SHEET G-001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-01-11 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-11 |
Time |
06:33 |
Sent To |
|
|
| Notes |
| 2007-01-11 07:59:31 | REVISED SHEETS GOO1, G002, A101- A104 AND ELECTRICAL | | | SHEET ME 101. RESTAMP REST OF PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-15 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-15 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2006-12-15 09:51:18 | THE ARCHITECT (PHILIP ROBBIE) CAME IN AND REDLINE THE | | | PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-12-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-01 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-01 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2006-12-01 09:08:05 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE 2004 FBC EXISTING BUILDING CODE UNDER | | | APPLICABLE CODES ON G-002. | | | | | | 3) ALSO ON G-002 SPECIFY THE LEVEL OF ALTERATION AS | | | DESIGNATED IN CHAPTER 3 OF THE FBC EXISTING BUILDING | | | CODE. THIS PROJECT IS A LEVEL 2 ALTERATION. | | | | | | 4)FBC 11-4.24.3 REQUIRES KNEE CLEARANCE UNDERNEATH | | | SINKS. DETAIL D ON A-104 HAS A CABINET WITH SHELF SHOWN | | | BELOW THE SINK. | | | | | | 5) THE DETAILS ON A-104 ARE INCORRECTLY LABELED AS | | | A-103. | | | | | | 6) THE REDLINE CORRECTIONS TO DRAWING MW-3 ON A-104 ARE | | | REQUIRED TO BE INITIALED AND DATED BY THE DESIGNER OF | | | RECORD THAT HAS SIGNED AND SEALED THE DRAWING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-10-25 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-10-25 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2006-10-25 10:19:18 | DENIED BY BUILDING | | | | | | 1) THE RECORDED COPY OF THE NOC MUST BE SUBMITTED | | | BEFORE PERMIT WILL BE ISSUED. | | | | | | 2) THE PROJECT IS A LEVEL II ALTERATION AS STATED IN | | | YOUR RESPONSE LETTER. PLEASE SPECIFY THE LEVEL OF | | | ALTERATION ON THE PLANS. | | | | | | 3) PLEASE SPECIFY THE EXISTING TYPE OF CONSTRUCTION | | | THAT WAS INDICATED IN THE RESPONCE LETTER (TYPE II-A) | | | ON THE PLANS. | | | | | | 4) ON SHEET G-002 STILL SPECIFIES TABLE 600UNDER | | | BUILDING SEPARATION NOTES. PLEASE CORRECT TO TABLE | | | 601. | | | | | | 5) FBC 11-4.24.3 REQUIRES KNEE CLEARANCE UNDERNEATH | | | SINKS. SHOW THE REQUIRED CLEARANCE ON THE PLANS. | | | | | | 6) SUITE NUMBER ADDRESS ON PLANS IS 275. THIS DOES NOT | | | AGREE WITH SUITE NUMBER ASSIGNED BY THE CITY. THIS MUST | | | BE CORRECTED BEFORE PERMIT CAN BE ISSUED. CONTACT LILI | | | URSU AT 561-822-1239. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-10-02 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-10-02 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | SUBMITTED FOR PLAN REVIEW NOT FOR PERMIT | | | | | | | | | | | | DENIED BY BUILDING | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE LEVEL OF ALTERATION FOR | | | THE PROJECT AS DEFINED IN THE 2004 FBC | | | EXISTING BUILDING CODE. | | | | | | 3) SPECIFY THE TYPE OF CONSTRUCTION FOR | | | THE BUILDING USING THE 2004 FBC | | | DESIGNATION. | | | | | | 4) ON SHEET G-002 BASED ON THE 2004 FBC | | | THE BUILDING HEIGHT AND AREA TABLE IS | | | 503 AND THE TABLE FOR FIRE WALL RATING | | | IS 601. PLEASE CORRECT. | | | | | | 5) ON G-002 THE OCCUPANT LOAD FOR 6619 | | | SQFT IS 67 PERSONS. PLEASE CORRECT. | | | | | | 6) ON G-002 THE EXIT CAPACITY SHOULD BE | | | 67 X 0.2". PLEASE CORRECT. | | | | | | 7) FBC 1013.2 DOES NOT ALLOW EGRESS TO | | | PASS THROUGH A KITCHEN. ROOM 113 ON | | | A-102 APPEARS TO BE A BREAKROOM AND NOT | | | A KITCHEN. PLEASE LABEL ROOM 113 AS THE | | | BREAKROOM. | | | | | | 8) ON A-103 NOTES 4 AND 5 INCORRECTLY | | | REFERENCE CODE SECTION 705.1.3.6. PLEASE | | | CORRECT. SEE FBC 715.4.3. | | | | | | 9) THE BREAKROOM SINK IS REQUIRED TO BE | | | ACCESSIBLE AND COMPLY WITH FBC 11-4.24. | | | | | | 10) FIXED OR BUILT-IN SEATING AND TABLES | | | ARE REQUIRED TO COMPLY WITH FBC 11-4.32. | | | SEE FIXED SEATING IN BREAKROOM. | | | | | | 11) DETAIL MW-14 IS CROSSED OUT ON SHEET | | | A-104. HOWEVER, IT IS STILL SHOWN ON | | | A-102. | | | | | | 12) THE DOOR TO OFFICE 105 IS REQUIRED | | | TO HAVE A MINIMUM OF 18" CLEARANCE ON | | | THE PULL SIDE OF THE DOOR AT THE LATCH | | | SIDE. SEE FBC 11-4.13.6. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-25 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-25 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2007-02-25 08:50:50 | VALUE INCREASED, PLANS STAMPED OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-12 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-12 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2007-02-12 15:08:58 | ** UNSAT ** | | | | | | | | | 1) NOTE: PLEASE SEE THE SCOPE OF WORK NOW INCLUDED ON | | | PLANS WAS NOT IN SCOPE OF WORK FOR PROJECT UNDER | | | ORIGINAL PERMIT APPLICATION. | | | PLEASE ADJUST PERMIT APPLICATION, VALUE SCOPE ETC. | | | PLEASE SEE THAT THIS SCOPE OF WORK CAN ALSO BE DONE | | | UNDER A SEPARATE PERMIT APPLICATION. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-02-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-07 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-07 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-10 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-10 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2007-01-10 11:23:54 | SHEETME-001 NOT STAMPED AS IT CONTAINS NO REVISONS | | | AND IS THE SAME SHEET WHICH IS ALREADY ON FILE./ |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-28 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-28 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2006-11-28 17:51:09 | REDLINED, | | | | | | ALL LIGHTING AND LIGHTING CONTROLS SHALL MEET 2004 FBC | | | CHAPTER 13 AS SHOWN ON PLANS. | | | AS SOME SWITCHING IS SHOWN VERY SMALL, PLEASE BE SURE | | | TO SEE 13-415.1.ABC.1.2 FOR SEPARATE SPCE CONTROL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-10-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-22 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-22 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2006-10-22 16:47:02 | ***** UNSAT 2ND REVIEW****** | | | | | | *** PLEASE KNOW, THIS PROJECTIS STILLONLY | | | BEEN SUBMITTED FOR "PLAN REVIEW" ONLY | | | AND HAS NOT BEEN SUBMITTED FOR PERMIT. | | | PLEASE SEE SOME NOTE SFROM PREVIOUS REVIEW AND SOME NEW | | | NOTES DUE TO THE PLANS SUBMITTED. PLEASE SEE NOTES | | | BELOW ARE TAKEN DIRECTLY FROM PREVIOUS REVIEW WITH NEW | | | NOTES ADDED TO BOTTOM. | | | | | | 1) NOTE: OK. | | | | | | 2) NOTE:NO/OK. PLEASE SEE PLANS ARE NOW BEING | | | SUBMITTED WITH A SUITE NUMBER OF #275?? PLEASE SEE | | | ORIGINAL "PLAN REVIEW" APPLICATION SHEET INDICATED | | | #210. PLEASE SEE AN EXTENSION WAS GRANTED AND ISSUED BY | | | THE ADDRESSING REVIEWER FOR SUITE #210, HOWEVER NOW | | | SHOWS #275. PLEASE CORRELATE THIS WITH THE ADDRESSING | | | REVIEWER AND PLACE ON FINAL TITLE BLOCKS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE ALL TITLE BLOCKS | | | SHALL CONTAIN THE RELEVANT ADDRESS AND | | | SUITE NUMBER FOR LOCATION OF PROJECT. | | | FAC 61G1-16.004, FAC 61G15-23.002 | | | REQUIRED FOR ALL SHEETS AND FOR ALL | | | TRADES WHETHER OR NOT COMMENT IS | | | ADDRESSED BY OTHER TRADES. | | | | | | 3) NOTE: NO, SAME NOTE. | | | PLEASE SEE NO SCHEDULING WAS SUBMITTED. | | | PLEASE SEE TIMES ONE OVER RIDES ARE NOT INDICATED ON | | | SYMBOL LEGAND ON DEVICES. | | | PLEASE SEE A SYSTEM IS NOT SHOWN. | | | PLEASE SEE NO PERFORMANCE CALCULAITONS WERE SUBMITTED. | | | ETC | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FBC 2004 CHAPTER 13. | | | PLEASE SUBMIT AND SHOW THE SYSTEM WHICH | | | IS REQUIRED FOR LIGHTING CONTROLS. | | | PLEASE SUBMIT COMPLETE SCHEDULING. | | | PLEASE SUBMIT AND SHOW ALL LOCATIONS OF | | | OVER-RIDE DEVICES. PLEASE SEE CODE WITH | | | RESPECT TO LOCATIONS AS THE OCCUPANT | | | MUST BE ABLE TO SEE THE LIGHTING WHICH | | | IS BEING CONTROLLED. | | | PLEASE INDICATE THE DEVICES AND THE | | | TIMES PERMITTED FOR OVER-RIDES (MAX | | | TIMES). | | | PLEASE SUBMIT PERFORMANCE CALCULATIONS. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND | | | .1.3. | | | PLEASE SEE 13-415.2, 13-415.2.ABC.1 AND | | | TABLES. 415. | | | | | | 4) NOTE: NO, PLEASE SEE ALL LOADS ON THE EXSITNG | | | WIREWAY NEED TO BE REFLECTED INCLUDING NEW LOADS PER | | | NEC. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE LOADS ON EXISING | | | WIRE-WAY WHICH NEW SERVICE FOR TENANT IS | | | BEING TAPPED, ALONG WITH EXISTING FEED | | | FROM MDP. | | | 220, 220.3,220.10,220.11,220.13, ETC | | | 215.3 AND 230.42 ETC FOR CONTINOUS | | | LOADS. | | | | | | 5) NOTE:OK. | | | | | | 6) NOTE:NO, ONLY REFERENCE TO THE NEC ARTICLES WHICH | | | WERE GIVEN ON PREVIOUS REVIEW FOR COMPLIANCE WAS PLACED | | | ON PLANS.PLEASE KNOW, PLACING NOTES ON PLANS IN LEIU | | | OF REQUIRED DETAIL(S) IS NOT ACCEPTABLE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE A NOTE FOR A | | | "FLOATING NEUTRAL" IN TENANT METERCAN. 250.6.250.24 | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE: OK. HOWEVER PLEASE SEE DESIGNATION FOR ROOM IS | | | NOT ON ELECTRICLA POWER PLAN. | | | | | | | | | 9) NOTE: NO, PLEASE INDICATE FOR ALL NEW. | | | 110.9, 240.12 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE ALL AIC RATINGS | | | FOR ALL SERVICE EQUIPMENT. | | | 110.9. | | | | | | 10) NOTE: NO, PLEASE INDICATE AND SHOW ATTACHMENT | | | LOCATION. QUOTING OF CODE IN LEIU OF SPECIFIC | | | INFORMATION IS NOT PERMITED. | | | AN ASSUMPTION OF THE CONTRACTORS WORK CAN NOT BE | | | EXPECTED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | ' PLEASE INDICATE AND SHOW THE | | | LOCATION OF THE GROUND ATTACHMENT FOR | | | THE THE TRANSFORMER. PLEASE SEE 250.30, | | | 250.66, 250.20 ETC. | | | | | | ** NEW NOTES** | | | | | | 11) NOTE: PLEASE SEE NEW ME PLANS ARE NOT SEALED BY THE | | | DESIGNER OF RECORD AS REQUIRED UNDER FS 471.025, AND | | | FAC 61G15-23.002. | | | PLEASE SEE BOTH SETS ARE THE SAME. AN EMBOSSED RAISED | | | SEAL IS REQUIRED. | | | | | | 12) NOTE: PLEASE CLARIFY WHAT IS SHOWN AS "H2C AND | | | "L2C" ON RISER. ARE THESE PART OF THE SAME TENANT | | | SPACE? IF SO, MAINS ARE NOT GROUPED PER 230.72, ETC. | | | PLEASE KNOW, THIS CAN BE REMOVED IF NOT PART OF THIS | | | TENANT. | | | | | | ** PLEASE KNOW AS SOME INFORMATION HAS NOT BEEN | | | PROVIDED, THERE MAY BE FUTURE COMMENTS. | | | | | | ** PLEASE SEE ANY OTHER COMMENTS FROM | | | OTHER TRADES WHICHMAY AFFECT PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-03 |
Time |
19:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-03 |
Time |
07:07 |
Sent To |
PC |
|
| Notes |
| 2006-10-03 00:00:00 | ***** UNSAT ****** | | | | | | *** PLEASE KNOW, THIS PROJECT HAS ONLY | | | BEEN SUBMITTED FOR "PLAN REVIEW" ONLY | | | AND HAS NOT BEEN SUBMITTED FOR PERMIT. | | | | | | 1) NOTE: PLEASE BE SURE TO STATE THE | | | FOLLOWING MINIMUM CODES RELVANT TO THE | | | DESIGNS OF PROJECT SUBMITTED. | | | 2002 NFPA-72, 2002 NFPA-70, 2003 | | | NFPA-101, 2004 FBC. | | | | | | 2) NOTE: PLEASE SEE ALL TITLE BLOCKS | | | SHALL CONTAIN THE RELEVANT ADDRESS AND | | | SUITE NUMBER FOR LOCATION OF PROJECT. | | | FAC 61G1-16.004, FAC 61G15-23.002 | | | REQUIRED FOR ALL SHEETS AND FOR ALL | | | TRADES WHETHER OR NOT COMMENT IS | | | ADDRESSED BY OTHER TRADES. | | | | | | 3) NOTE: PLEASE SEE FBC 2004 CHAPTER 13. | | | PLEASE SUBMIT AND SHOW THE SYSTEM WHICH | | | IS REQUIRED FOR LIGHTING CONTROLS. | | | PLEASE SUBMIT COMPLETE SCHEDULING. | | | PLEASE SUBMIT AND SHOW ALL LOCATIONS OF | | | OVER-RIDE DEVICES. PLEASE SEE CODE WITH | | | RESPECT TO LOCATIONS AS THE OCCUPANT | | | MUST BE ABLE TO SEE THE LIGHTING WHICH | | | IS BEING CONTROLLED. | | | PLEASE INDICATE THE DEVICES AND THE | | | TIMES PERMITTED FOR OVER-RIDES (MAX | | | TIMES). | | | PLEASE SUBMIT PERFORMANCE CALCULATIONS. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND | | | .1.3. | | | PLEASE SEE 13-415.2, 13-415.2.ABC.1 AND | | | TABLES. 415. | | | | | | 4) NOTE: PLEASE PROVIDE LOADS ON EXISING | | | WIRE-WAY WHICH NEW SERVICE FOR TENANT IS | | | BEING TAPPED, ALONG WITH EXISTING FEED | | | FROM MDP. | | | 220, 220.3,220.10,220.11,220.13, ETC | | | 215.3 AND 230.42 ETC FOR CONTINOUS | | | LOADS. | | | | | | 5) NOTE: PLEASE SEE EXSTING FEED FROM | | | THE MDP IS SHOWN #3'S ON A 200A | | | BREAKER/OCP WHICH IS NOT PERMITTED. | | | 240.4,310.16 | | | | | | 6) NOTE: PLEASE INDICATE A NOTE FOR A | | | "FLOATING NEUTRAL" IN TENANT METERCAN. 250.6.250.24 | | | | | | 7) NOTE: PLEASE SEE LOAD ON H2D EXCEEDS | | | THE RATING OF THE EQUIPMENT FEEDING THIS | | | PANEL. PLEASE SEE RISER ONLY SHOWS A 60A | | | FEED, | | | PLEASE ADJUST. | | | 240, 408 ETC | | | | | | 8) NOTE: PLEASE INDICATE THE MIN | | | CLEARENCES IN FRONT OF ALL ELECTRICAL | | | SERVICE EQUIPMENT. | | | 110.26, 450.13, 450.9 ETC. | | | | | | 9) NOTE: PLEASE INDICATE ALL AIC RATINGS | | | FOR ALL SERVICE EQUIPMENT. | | | 110.9. | | | | | | 10) NOTE: PLEASE INDICATE AND SHOW THE | | | LOCATION OF THE GROUND ATTACHMENT FOR | | | THE THE TRANSFORMER. PLEASE SEE 250.30, | | | 250.66, 250.20 ETC. | | | | | | ** PLEASE SEE ANY OTHER COMMENTS FROM | | | OTHER TRADES WHICHMAY AFFECT PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-27 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-27 |
Time |
12:54 |
Sent To |
B |
|
| Notes |
| 2007-02-27 13:01:02 | *****APPROVED***** | | | | | | | | | **REVISED PLAN SHEET (G-002) DATED 02/07/2007WAS | | | STAMPED, INITIALED, AND DATED.** |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-10 |
Time |
19:05 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-27 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2007-01-10 19:07:41 | *****APPROVED***** | | | | | | | | | **REVISED PLAN SHEET (G-002) DATED 12/19/2006 WAS | | | STAMPED, INITIALED, AND DATED.** | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-06 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-06 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2006-12-06 12:51:19 | *****APPROVED***** | | | | | | | | | | | | | | | PLAN SHEET G-002 STAMPED AND DATED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-30 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-30 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2006-10-30 11:36:29 | *****APPROVED***** | | | | | | | | | ALL FIRE PLAN REVIEW COMMENTS OF 10/02/2006 HAVE BEEN | | | ADDRESSED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-02 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-02 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | *****DENIED***** | | | | | | | | | | | | | | | 1.) NFPA 101-2003 EDITION AND FLORIDA | | | FIRE PREVENTION CODE-2004 EDITION SHALL | | | BE REFERENCED. | | | | | | 2.) STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241. | | | | | | 3.) BUILDINGS OR PORTIONS OF BUILDINGS | | | SHALL BE PERMITTED TO BE OCCUPOED DURING CONSTRUCTION, | | | REPAIR, ALTERATIONS, OR | | | ADDITIONS ONLY WHERE REQUIRED MEANS OF | | | EGRESS AND REQUIRED FIRE PROTECTION | | | FEATURES ARE IN PLACE AND CONTINUOUSLY | | | MAINTAINED FOR THE PORTION OCCUPIED OR | | | WHERE ALTERNATIVE LIFE SAFETY MEASURES | | | ACCEPTABLE TO THE AUTHORITY HAVING | | | JURISDICTION ARE IN PLACE. | | | | | | 4.) EXITS ARE TO REMAIN CLEAR AND | | | UNOBSTRUCTED. | | | | | | 5.) ALL FIRE DOORS AND WINDOWS TO COMPLY | | | WITH NFPA 80, FIRE DOORS AND WINDOWS. | | | | | | 6. INTERIOR FINISH FOR WALLS AND CEILING | | | IN EXITS AND EGRESS CORRIDORS SHALL BE | | | CLASS"A" OR CLASS "B". | | | | | | 7.) INDICATE ON PLANS THE LOCATION OF | | | FIRE PROTECTION SYSTEMS (I.E. SPRINKLER, | | | SMOKE DETECTORS, ETC.) AND HOW THE | | | LISTED ALTERATIONS WILL AFFECT THEIR | | | OPERATION. | | | | | | 8.) IF THE SCOPE OF THE INTERIOR | | | BUILDOUT REQUIRES MODIFICATION OF THE | | | FIRE ALARM AND/OR FIRE SPRINKLER SYSTEM, | | | SEPARATE PERMIT AND SHOP DRAWING/PLAN | | | ARE REQUIRED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-23 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-23 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2007-02-23 16:06:08 | TO "BOB"#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-12 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-12 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2007-02-12 09:18:54 | TO "BOB"#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-02 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-02 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2007-02-06 10:31:24 | TO "BOB"#4 | | 2007-02-02 14:38:44 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-01-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-08 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-08 |
Time |
10:27 |
Sent To |
M |
|
| Notes |
| 2007-01-08 10:27:25 | TO "PKRAUSS" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-26 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-26 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2007-01-09 13:41:22 | TO "BOB"#4 | | 2006-12-26 13:16:01 | WAITING FOR "BOB"--REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-13 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-13 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2006-11-27 09:03:42 | TO "BOB"#6 | | 2006-11-13 09:21:20 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-10-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-13 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-13 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2006-10-22 16:53:29 | BOB BOARD #13 | | 2006-10-13 09:03:02 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-10-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2006-09-27 00:00:00 | TO "BOB"#11 | | 2006-09-23 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-13 |
Time |
09:33 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2007-02-13 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2007-02-13 09:33:55 | NO MECHANICAL CHANGES TO PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-10 |
Time |
15:48 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2007-01-10 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2007-01-10 15:48:55 | RE-STAMP MECHANICAL PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-01-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2007-01-08 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2007-01-08 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2007-01-08 11:11:46 | REVISED DUCT / FROM ROUND TO SQUARE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-27 |
Time |
10:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-27 |
Time |
10:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-23 |
Time |
09:20 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-23 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2006-10-23 09:33:57 | **FOR PLAN REVIEW ONLY NOT FOR PERMIT** | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 9-28-06 NOTE #2. | | | SEE PAGE ME-103 CONDENSER UNIT | | | MOUNTING DETAIL, PLEASE SHOW HOW | | | CONDENSER STAND NEEDS TO BE SECURED TO | | | ROOF, AND HOW CONDENSER UNIT NEEDS TO BE | | | SECURED TO STAND TO WITHSTAND 140 MPH | | | WINDS, PER 2004 FBC 1609. | | | (THE CITY OF WPB DOES NOT PERMIT CABLE STRIPS OVER | | | CONDENSRE UNITS), SHOW SIZES OF ANCHOR BOLT FROM | | | CONDENSER UNIT TO STAND. | | | SEE PIPE SUPPORT DETAIL NEED TO SHOW HOW THE STEEL | | | PLATE FROM THE CONDENSER STAND IS TO BE SECURED TO THE | | | STEEL JOIST. | | | | | | 2) PLANS PAGE ME-001 THROUGH ME-104 NEED TO BE SEALED | | | BY THE ENGINEER, PER FAC 61G15-23.002. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-28 |
Time |
13:36 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-09-28 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2006-09-28 00:00:00 | **FOR PLAN REVIEW ONLY NOT FOR PERMIT** | | | *** DENIED *** | | | 1) SEE PAGE ME-001, PLEASE PROVIDE | | | OUTDOOR AIR CALCULATIONS, PER 2004 FBC/M | | | 403.2 . | | | | | | 2) SEE PAGE ME-103 CONDENSER UNIT | | | MOUNTING DETAIL, PLEASE SHOW HOW | | | CONDENSER STAND NEEDS TO BE SECURED TO | | | ROOF, AND HOW CONDENSER UNIT NEEDS TO BE | | | SECURED TO STAND TO WITHSTAND 140 MPH | | | WINDS, PER 2004 FBC 1609. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-12-13 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-12-13 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2006-12-13 17:54:26 | PASSED/PROVISO: 11-4.24.3, 11-4.24.5, 11-4.24.7 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-11-09 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-11-09 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2006-11-09 10:00:30 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 11 | | | MUNICIPAL CODE | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ************PLAN REVIEW ONLY************ | | | SECOND REVIEW | | | | | | 1. SHT A-104 DETAIL MW-3. THE FOLLOWING INFORMATION IS | | | REQUIRED TO SHOW | | | COMPLIANCE WITH SECTION 11-4.24. | | | A. OK | | | B. 11-4.24.3 KNEE CLEARANCE - NOT SHOWN | | | C. OK | | | D. 11-4.24.5 CLEAR FLOOR SPACE - | | | FORWARD APPROACH IS REQUIRED, MAXIMUM | | | 19" UNDERNEATH THE SINK. CABINET DOORS | | | ARE NOT APPROVED IN CLEAR FLOOR SPACE. - NOT SHOWN | | | UNDERNEATH THE SINK AS REQUIRED. | | | E. OK | | | F. 11-4.24.7 FAUCETS. - NOT ADDRESSED | | | | | | 2. OK | | | 3. OK | | | | | | **************NEW COMMENT************** | | | | | | 1B. SEE COMMENT #2 FROM ELECTRICAL REVIEW WITH RESPECT | | | TO THE TITLE BLOCK INFORMATION REQUIRED FOR THE ADDRESS | | | AND SUITE NUMBER FOR PROJECT. FAC 61G1-16.004(1) & FS | | | 481.2055. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-27 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-27 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2006-09-27 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 11 | | | MUNICIPAL CODE | | | | | | ************PLAN REVIEW ONLY************ | | | | | | 1. SHT A-104 DETAIL MW-3. THE FOLLOWING INFORMATION IS | | | REQUIRED TO SHOW | | | COMPLIANCE WITH SECTION 11-4.24. | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.5 CLEAR FLOOR SPACE - | | | FORWARD APPROACH IS REQUIRED, MAXIMUM | | | 19" UNDERNEATH THE SINK. CABINET DOORS | | | ARE NOT APPROVED IN CLEAR FLOOR SPACE. | | | E. 11-4.24.6 EXPOSED PIPES & SURFACES | | | F. 11-4.24.7 FAUCETS. | | | | | | 2. SHT ME-2 CONDENSATE NOT APPROVED TO | | | DRAIN INTO THE SANITARY SYSTEM. CITY | | | CODE 90-125(B)(5). CONDENSATE SHALL | | | DRAIN SEPARATELY OUT OF THE BUILDING AND | | | CONNECT TO STORM, (WITH A RELIEF VENT OR | | | GOOSENECK AS IT EXITS THE BUILDING), A | | | CATCH BASIN, A DRYWELL, OR INTO A | | | PLANTED AREA TERMINATING 6" ABOVE THE | | | GROUND LEVEL. | | | | | | 3. SHT ME-2 WATER RISER DIAGRAM | | | ISOMETRIC. THE WATER HAMMER ARRESTOR | | | PROVIDED SHALL BE LOCATED NEAR THE | | | FIXTURE, IN AN "EFFECTIVE RANGE", NOT IN | | | THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|