Plan Review Details - Permit 06090569
| Plan Review Stops For Permit 06090569 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-09-25 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-09-25 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2006-09-25 00:00:00 | DENIED BY BUILDING | | | | | | 1) SPECIFY THE LEVEL OF ALTERATION FOR | | | THE WORK PER THE 2004 FBC EXISTING | | | BUILDING CODE. | | | | | | 2) SPECIFY THE CONSTRUCTION TYPE, NUMBER | | | OF FLOORS, SPRINKLERED BUILDING, ETC. | | | FOR THE BUILDING. | | | | | | 3) PROVIDE A DETAIL OF THE NEW PARTITION | | | WALLS. SPECIFY WALL TYPE. | | | | | | 4) FBC 603.1 LIMITS THE APPLICATION OF | | | COMBUSTIBLE MATERIALS IN BUILDINGS OF | | | TYPE I OR II CONSTRUCTION. SHOW | | | COMPLIANCE. | | | | | | 5) THE NEW POWDER ROOM MUST COMPLY WITH | | | THE FAIR HOUSING ACT DESIGN MANUAL FOR | | | THE FOLLOWING. (REQUIREMENT 3) A USABLE | | | DOOR WITH A NOMINAL 32" CLEAR OPENING IS | | | REQUIRED, (REQUIREMENT 4) AN ACCESSIBLE | | | ROUTE TO AND INTO THE POWDER ROOM IS | | | REQUIRED AND (REQUIREMENT 5) A | | | RECEPTACLE IN AN ACCESSIBLE LOCATION. | | | SEE PAGE 7.38 OF DESIGN MANUAL. | | | | | | 6) FAC 61G1-16.004 REQUIRES THE | | | ARCHITECTURAL FIRM'S LICENSE NUMBER IN | | | THE TITLE BLOCK. | | | | | | 7) FAC 61G-16.003 REQUIRES THE ARCHITECT | | | TO DATE EACH SHEET THAT THEY SIGN AND | | | SEAL. | | | | | | 8) ADDRESS COMMENTS FROM OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-30 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
PC |
|
| Notes |
| 2007-07-30 14:14:04 | *** PLANS SENT BACK AS PERMIT APPLICATION TIME HAS | | | EXPIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-24 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-24 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2006-09-24 00:00:00 | ***UNSAT *** | | | | | | 1)NOTE: PLEASE SEE MISSING LICENSE | | | INFORMATION REQUIRED ON TITLE BLOCKS AS | | | REQUIRED PER FAC 61G1-16.004, FS 481.219 | | | PLEASE SEE MISSING FIRM # AKA, | | | CERTIFICATE OF AUTHORIZATION NUMBER. | | | THIS IS REQUIRED FOR ALL TRADES AND FOR | | | ALL SHEETS WHETHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-03 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-03 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | *****DENIED***** | | | | | | | | | | | | 1.) ALL OTHER PLAN REVIEWER'S ISSUES | | | MUST BE ADDRESSED AND/OR RECTIFIED. | | | | | | 2.) STRUCTURES UNDERGOING CONSTRUCTION, | | | ALTERTION, OR DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241. | | | | | | 3.) ACCUMULATIONS OF COMBUSTIBLE WASTE | | | MATERIAL AND DUST DEBRIS SHALL BE | | | REMOVED FROM THE STRUCTURE AND ITS | | | IMMEDIATE VICINITY AT THE END OF THE | | | SHIFT OR MORE FREQUENTLY AS NECESSARY | | | FOR SAFE OPERATIONS. | | | | | | 4.) ENTRANCES, CORRIDORS, AND EXITS ARE | | | NOT BE HINDERED OR COMPROMISED BY THE | | | STOCKING AND/OR DISPOSAL OF BUILDING | | | MATERIALS. | | | | | | 5.) IF THE SCOPE OF THE INTERIOR | | | BUILDOUT REQUIRES MODIFICATION OF THE | | | FIRE PROTECTION SYSTEM, PROVIDE SEPARATE | | | PERMIT AND PLANS. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-18 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-18 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2007-07-26 14:10:58 | TO "BOB"#8 | | 2007-07-18 08:33:01 | WAITING FOR "BOB" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-03 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-09-18 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2006-09-23 00:00:00 | TO "BOB"#1 | | 2006-09-18 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-27 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-27 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2006-09-27 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | | | | 1. SHT A101 PER FAC 61G1-16.004(2) THE | | | FIRM LICENSE NUMBER IS REQUIRED IN THE | | | TITLE BLOCK. ARCHITECTS LICENSE NUMBER | | | IS SHOWN. NO LICENSE NUMBER FOR EDRC | | | ARCHITECTS. FS 481.219. | | | | | | 2. THE SANITARY SYSTEM IS AN ENGINEERED | | | SYSTEM, (SOVENT). CHANGE TO AN | | | ENGINEERED SYSTEM SHALL BE SUBMITTED BY | | | AN ENGINEER AND EXISTING RISERS SHALL BE | | | SHOWN, WITH CHANGES INDICATED. SHOW ALL | | | PIPE SIZES AND VENTING IF REQUIRED. | | | SECTION 106.3.5.1.3. | | | | | | 3. SUBMIT A WATER RISER DIAGRAM | | | ISOMETRIC SHOWING ALL PIPE SIZES, | | | VALVES, AND WATER HAMMER ARRESTORS | | | REQUIRED BY SECTION 604.9. WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE | | | FIXTURE IN AN, "EFFECTIVE RANGE", NOT IN | | | THE CEILING. WH-PDI 201 AND MANUF. | | | INSTALLATION INSTRUCTIONS. | | | | | | 4. SHT A101 STAFF TOILET PLUMBING PLAN | | | SHOWS 1-1/2" SANT. PIPING TO THE WASH | | | MACHINE. PER TABLE 709.1, MINIMUM 2" | | | TRAP IS REQUIRED. | | | | | | 5. SUBMIT MANUF. SPECIFICATIONS FOR THE | | | LAV AND THE W/C. PER FIGURE 405.3.1 THE | | | MINIMUM CLEARNACE BETWEEN THE W/C AND | | | THE LAV IS 21". PLANS INDICATE 57-1/4" | | | OPENING IN ROOM AND SCALES OUT LESS THAN | | | REQUIRED CLEARANCE. SECTION 106.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
|