| Plan Review Stops For Permit 06090474 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-09-21 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-09-14 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2006-09-21 00:00:00 | ATTACH PERMIT TO : TEMP7442430208101 | | 2006-09-14 00:00:00 | NEED TO ADD AN EXTENSION TO THIS ADDRESS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-29 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-29 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-09-19 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-09-19 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2006-09-19 00:00:00 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) 505.2 AREA LIMITATION. | | | THE AGGREGATE AREA OF A MEZZANINE OR | | | MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. IN DETERMINING THE ALLOWABLE | | | MEZZANINE AREA, THE AREA OF THE | | | MEZZANINE SHALL NOT BE INCLUDED IN THE | | | AREA OF THE ROOM. SUBMIT CALCULATIONS | | | INDICATING THAT THE AREA OF THE | | | MEZZANINE DOES NOT EXCEED ONE-THIRD OF | | | THE FLOOR AREA OF THE ROOM IN WHICH IT | | | IS LOCATED, NOT INCLUDING THE ENCLOSED | | | AREAS OF THE FIRST FLOOR (INCLUDING NEW | | | ENCLOSURE AT OVERHEAD DOOR). | | | | | | 3) THE EXTERIOR OVERHEAD DOOR IS | | | REQUIRED TO REMAIN. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-16 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-16 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-20 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-20 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2006-09-20 00:00:00 | **********UNSAT ************* | | | | | | 1) NOTE: PLEASE INDICATE ALL CIRCUITING | | | ON PLANS AND CORRELATE WITH A PANEL | | | SCHEDULE TO BE PROVIDED. | | | 408.4, 310.16,240.4 | | | FBC 106.1.2 | | | | | | 2) NOTE: PLEASE CLARIFY THE NEW OR | | | EXISTING LIGHTING LEVELS FOR THE STAIRS | | | WAYS FOR A MIN OF 10FT CANDLES UDNER | | | NORMAL AND 1FT MIN UNDER EMERGENCY. | | | 7.8.1.3, 7.9.2.2 | | | PLEASE ALSO INDICATE SOME SORT OF EM | | | BATTERY BACK UP FIXTURE REQUIRED FOR MIN | | | LTS. | | | | | | 3) NOTE: PLEASE SEE BUILDING REVIEW | | | COMMENTS AS TO ANY COMMENTS WHIHC MAY | | | AFFECT THE ELECTRICAL DESIGN. | | | | | | 4) NOTE: PLEASE SEE ITEMS ON NOTES WHICH | | | ARE NOT ON PLANS. SD'S ETC. | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE SEE THAT ALL PLANS ARE | | | REQUIRED TO CONTAIN THE PRINTED NAME, | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | PLANS AND DESIGN. | | | FBC 106.1.2 ADMIN SECT. | | | | | | 6) NOTE: PLEASE COMPLETE PANEL SCHEDULE | | | WITH ALL OCP AND CONDUCTOR SIZES. PLEASE | | | SEE THAT SOME ITEMS ARE SHOWN , BUT NOT | | | CLEAR WHAT THEY ARE FEEDING. (50A | | | CIRCUIT, ETC | | | ALL AREAS /ROOMS ARE TO BE SPECIFIC . | | | 240.4,310.16,408.4 | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-11-22 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-11-22 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-21 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-21 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2006-09-21 00:00:00 | ***DENIED*** | | | | | | 1) PLANS SHOW EXISTING STROBE LIGHTS. | | | WHAT ARE THEY CONNECTED TO? IF PART OF A | | | FIRE ALARM SYSTEM OR EXISTING STAND | | | ALONE AC UNIT DUCTS, PLEASE INDICATE AND | | | ALSO SHOW IF THEY INCLUDE AUDIBILITY. | | | | | | 2) IS THERE AN EXISTING FIRE SPRINKLER | | | SYSTEM, AND IF SO WILL THIS WORK HAVE AN | | | IMPACT ON SUCH SYSTEM? | | | | | | 3) CONSTRUCTION, ALTERATION AND | | | DEMOLITION SHALL COMPLY WITH NFPA 241. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-06 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-06 |
Time |
16:27 |
Sent To |
M |
|
| Notes |
| 2007-03-06 16:27:27 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-07 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-07 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2006-11-16 11:44:07 | TO "BOB"#13 | | 2006-11-07 16:52:58 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-21 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-14 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2006-09-14 00:00:00 | TO "BOB"#12 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-08 |
Time |
13:41 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-03-08 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2007-03-08 13:42:32 | MECHANICAL REVISION TO PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-07 |
Time |
12:02 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-03-07 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2007-03-07 12:12:34 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) PLEASE SHOW CFM'S AT SUPPLY AIR GRILLS. | | | NOTE. 12" RETURN AIR DUCT MAY BE TO SMALL BUT CAN NOT | | | DETERMINE UNTIL CFM'S ARE SHOWN. | | | | | | 2)ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-22 |
Time |
11:20 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-11-22 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-15 |
Time |
13:36 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-09-15 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2006-09-15 00:00:00 | *** DENIED *** | | | 1) PLANS NEED THE DESIGNER'S INFORMATION | | | ON THEM. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | 2) 10" RETURN AIR DUCT (FLEX) TO TRUNK | | | LINE IS TO SMALL, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|