Plan Review Details - Permit 06090383
| Plan Review Stops For Permit 06090383 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-04-23 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-23 |
Time |
07:45 |
Sent To |
PC |
|
| Notes |
| 2008-04-23 17:09:18 | MERRY PLACE PROJECT, PICNIC SHELTERS BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004. | | | | | | 1- SITESTRUCTURE AMENITIES LIKE PICNIC SHELTERS AND | | | PLAYGROUNDS NEED TO BE SUBMITTED UNDER A SEPARATE | | | PERMIT. | | | | | | 2- CALCULATIONS SUBMITTED DON'T MATCH SIZE AND TYPE OF | | | STRUCTURE SHOWN ON FLOOR PLAN SUBMITTED. CALCULATIONS | | | ARE FOR 18' PITTSBURGH SQUARE SHELTERS, WHILE DRAWINGS | | | SHOW 18' X 36'RECTANGULAR SHELTERS.ALSO, SEE THE | | | 1/4" STEEL CABLE AROUND PERIMETER OF SHELTER. REVISE AS | | | REQUIRED TO MATCH. | | | | | | 3- ENGINEER NEEDS TO PROVIDE ALL HIS INFORMATION IN ALL | | | CALCULATIONS SHEETSAS REQUIRED BY SEC. 61G15-23.002 | | | FLORIDA ADMINISTRATIVE CODE AND CHAPTER 471 FLORIDA | | | STATUTE. | | | | | | 4- ENGINEER NEEDS TO SIGN AND SEAL ALL CALCULATIONS | | | SHEETS. SOME ARE MISSING THE SIGNATURE. SEC | | | 61G15-23.002 FLORIDA ADMINISTRATIVE CODE AND CHAPTER | | | 471 FLORIDA STATUTE. | | | | | | 5-IF ONLY THE STRUCTURE IS DESIGNED TO RESIST THE | | | 140MPH WIND LOAD WITHOUT THE FABRIC , THEN NEED TO | | | PROVIDE FABRIC REMOVAL INSTRUCTIONS TO SHOW COMPLIANCE | | | WITH SEC. 3105.4.2.1 FBC 2004 FOR QUICK RELEASE.THE | | | INSTRUCTIONS SHOULD CONSIST OF A SERIES OF PHOTOGRAPHS. | | | THIS IS TO BE APPROVED BY THE BUILDING OFFICIAL. | | | PROVIDE COMPLETE INFORMATION AS REQUIRED. | | | | | | 6- PER BUILDING OFFICIAL, NEIL MELICK,A LETTER SIGNED | | | BY THE OWNER (NOT TENANT)IS REQUIREDACKNOWLEDGING | | | RESPONSIBILITY TO HAVE THE FABRIC REMOVED PRIOR TO ANY | | | WIND EVENT WITH PROJECTED WIND SPEEDS OF 75 MPH OR | | | GREATER.PROVIDE LETTER FROM OWNER ACKNOWLEDGING REMOVAL | | | OFFABRIC. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-09-21 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-09-21 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2006-09-21 00:00:00 | CONDITIONAL APPROVAL: | | | | | | 1. MUST SUBMIT POLLUTION PREVENTION PLAN | | | & DETAIS BEFORE CONSTUCTION START. | | | | | | 2. MUST MEET CITY OF WPB STANDARDS FOR | | | DUMPSTER & ENCLOSURE,SIDEWALK, | | | | | | 3. STORM WATER CAL.,RUNOFF CAL.,CONTROL | | | STRUCTURES, EXFILTRATION TRENCH | | | CAL.,ETC.,SFWMD PERMIT,ETC., MUST BE | | | INCLUDED IN MASTER PERMIT. | | | | | | 4. FIRST FLOOR ELE.,SIDEWALK ELE.,CENTER | | | OF ROAD ELE.,ALL MUST MEET BUILDING | | | CODES & MUST BE IN MASTER PLAN. | | | | | | RASIK CHOKSHI 805-6723 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-09-21 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-09-14 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2006-09-14 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-09-20 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-09-20 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2006-09-20 00:00:00 | PLUMBING PLAN REVIEW PAUL SCHMITZ | | | 561-805-6692 | | | NOT REQUIRED | | | ENGINEERING PLAN REVIEW REQUIRED FOR | | | SITE WORK. | | | PLUMBIMNG SCOPE IN BUILDING AND 5' | | | OUTSIDE OF BUILDING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-09-19 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-09-19 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2006-09-19 00:00:00 | PER ANGELLA JONES-VANN NO ZONING REVIEW | | | REQUIRED. |
|
|
|