| Plan Review Stops For Permit 06090338 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-09-12 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-09-12 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2006-09-12 00:00:00 | EXT #0006 WAS ADDED FOR UNIT 100 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-07 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-12-12 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-05 |
Time |
16:45 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-10-05 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2006-10-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 06090338 | | | ADD: 560 VILLAGE SUITE# 100 | | | CONT: FISHER | | | TEL: (561)691-4916 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) DOOR 102 AND 121A ARE MISSING THE | | | REQUIRED 18" ON THE LATCH SIDE. | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARANCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARANCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 2) EXIT STAIRWAY( NOT IN UNIT) BETWEEN | | | OFFICE 116 AND 117 INTERIOR DOOR SWINGS | | | THE WRONG WAY. 1008.1.2 DOORS SHALL | | | SWING IN THE DIRECTION OF EGRESS TRAVEL | | | WHERE SERVING AN OCCUPANT LOAD OF 50 OR | | | MORE PERSONS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-08 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-08 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
| 2007-03-08 16:39:01 | REDLINED 408.4 AS PANEL SCHEDULE SHALL HAVE A PANEL | | | DIRECTORY WHICH IS SPECIFIC TO ALL ITEMS BEING SERVED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-14 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-14 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2007-02-14 15:47:35 | | | | **** UNSAT **** | | | | | | 1) NOTE:PLEASE SEE THAT THE PANEL SCHEDULE NEEDS TO | | | BE REVISED TO CORRELATE TO ALL AREAS AND ROOMS WHICH | | | CIRCUITS FEED. | | | PLEASE SEE THE FOLLOWING TEXT WHICH IS EXTRACTED FROM | | | 408.4 COMMENTARY OF THE NEC. | | | | | | *CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* | | | | | | PLEASE KNOW AS THE DRYWALL IS ALREADY INSTALLED, THESE | | | PLANS WILL BE FOR FINAL AND THE ABOVE IS REQUIRED TO | | | SPECIFIC AT THIS TIME. THIS IS FOR BOTH PANELS P AND | | | P2. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-01-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-04 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-04 |
Time |
19:21 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-24 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-24 |
Time |
13:29 |
Sent To |
PC |
|
| Notes |
| 2006-12-24 14:05:03 | **UNSAT 3RD REVIEW ** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW WHICH IS | | | STILL IN NEED OF ADDRESSING. | | | PLEASE SEE NOTE # 1 FROM PREVIOUS REVIEW. | | | | | | 1) NOTE: PLEASE BE SURE TO REMOVE ANY OLD | | | NON-APPLICABLE SHEETS FROM ENERGY CALCULATIONS WHICH DO | | | NOT APPLY. PLEASE SEE OLD SHEETS WERE LEFT IN ALONG | | | WITH NEW. | | | PLEASE CORRELATE ENERGY CALCULATIONS WITH THE FIXTURES | | | AND WATTAGE OF EACH FIXTURE ON PLAN. PLEASE SEE THE | | | WATTAGE DOES NOT CORRELATE. | | | THE EXCEPTION AS PERMITTED AS NOTED IS OK, HOWEVER | | | PLEASE SEE NOT ALL AREAS ARE BEING INCLUDED IN ENERGY | | | CALCULATIONS. | | | PLEASE ALSO SEE THERE ARE ROOMS WHICH ARE NOT BEING | | | INCLUDED FOR CONTROLS. DUE TO THE REMODEL/BUILD OUT | | | TAKING PLACE, THESE AREAS SHALL ALSO BE INCLUDED AS | | | STATED IN THE PREVIOUS REVIEW FOR ALL SEPARATE SPACES | | | CONTAINING FLOOR TO CEILING HEIGHT PARTITIONS. | | | PLEASE SEE ROOMS, 107,108,109,117, 118, 119 AND ROOM | | | WHICH IS NOTED AS CONFERENCE ROOM IN CENTER OF PLANS. | | | AT LAST CONVERSATION, IT WAS UNDERSTOOD THAT ALL AREAS | | | WOULD BE INCLUDED. | | | | | | 13-415.1.ABC.1.1, .1.2, AND .1.3, 13-415.1AB.1, | | | 13-415.2.ABC.1 | | | | | | ** PLEASE KNOW THIS IS NOT SOMETHING THAT CANNOT BE | | | REDLINED. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-28 |
Time |
19:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-28 |
Time |
19:21 |
Sent To |
|
|
| Notes |
| 2006-11-28 19:57:37 | **** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE ENERGY CALCULATIONS SUBMITTED WHICH | | | INDICATE MANUAL ON/OFF CONTROL CHOSEN FOR THE METHOD OF | | | CONTROLLING LIGHTING. PLEASE CHOOSE AUTO OPTION. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3. PLEASE SEE | | | MISSING OVER RIDE DEVICES LOCATED IN ALL SPACES | | | CONTAINING FLOOR TO CEILING HEIGHT PARTITIONS. | | | PLEASE SEE MISSING THE MAX TIMES PERMITTED FOR TYPE OF | | | OVER RIDES WHICH ARE NOT SHOWN AT THIS TIME. (30 MINS | | | MAX FOR OCCUPANT SENSOR TYPE DEVICES, 4HRS MAX FOR | | | TIMER TYPE.) | | | PLEASE SEE MISSING OVER RIDE CONTROLS AS THEY ARE | | | REQUIRED AT THE LOCATIONS OF INGRESS/EGRESS SO THE | | | OCCUPANT MAY BE ABLE TO CONTROL THE LIGHTS WHICH ARE IN | | | SIGHT. | | | PLEASE INDICATE DEVICES AND CORRELATE WITH THE SYMBOL | | | LEGEND. | | | PLEASE EXPLAIN NOTE NUMBER #6 ON DRAWING KEY NOTES AS | | | IT MENTIONS RELAY FOR NOT BEING ABLE TO OPERATE SOME | | | RECESSED LIGHTING AT THE SAME TIME WITH OTHERS?? | | | | | | 2) NOTE: PLEASE SEE FBC 2004 11-4.28.1, .2 AND .3(4). | | | PLEASE KNOW, ANY NEW FA DEVICES INSTALLED MUST MEET | | | THESE MINIMUM LEVELS. THIS WAS NOT IN PREVIOUS REVIEW | | | AS THIS WAS NOT IN THE SCOPE OF WORK OF ELECTRICAL | | | REVIEW, HOWEVER IT NOW IS.THE PRIMARY ISSUE IS ITEM | | | 11-4.28.3(4) WHICH REQUIRES A MIN OF 75 CANDELAS FOR | | | ANY NEW STROBE DEVICES. | | | PLEASE INDICATE ON LEGEND. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS, COMMENTS OR IF ANY PART OF | | | NOTES ABOVE ARE NOT UNDERSTOOD OR TYPED IN A MANNER | | | WHICH IS NOT CLEAR, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE OR REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-29 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-29 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2006-09-29 00:00:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE STATE THE FOLLOWING | | | RELEVANT CODES (WHICH ARE ON PLANS) | | | HOWEVER PLEASE GIVE YEAR EDITIONS | | | CURRENTLY INEFFECT FOR THE DESIGN. | | | 2002 NFPA-70, 2002 NFPA-72, 2003 | | | NFPA-101. | | | | | | | | | 2) NOTE: PLEASE EXPLAIN SERVICE | | | SCENARIO, IT IS UNCLEAR AT THIS TIME. IT | | | SEEMS LIGHTING ETC IS BEING NOTED AND | | | SHOWNFROM A SERVICE WHICH ALSO | | | FEEDS THE REST OF THE FLOOR?? | | | IS THIS NOT A SEPARATE TENANT? PLANS | | | INDICATE ADJACENT TENANT SPACES, HOWEVER | | | MAY NOT HAVE A SERVICE WHICH FEEDS ONE | | | TEANT FEED ANOTHER. PLEASE VERIFY AND | | | SHOW THE LOCATION OF THE OTHER | | | ELECTRICAL EQUIPMENT/SERVICE. NOT ABLE | | | TO DETERMINE SOME ITEMS AT THIS TIME. | | | 110.26,240.24,210.25 ETC. | | | | | | 3) NOTE: PLEASE SEE FBC CHAPTER 13 FOR | | | NEW BUILD OUTS OF TENANT SPACES AND | | | LIGHTING CONTROLS REQUIRED. | | | 13-415.1.ABC.1.1,.1.2,.1.3. | | | PLEASE SEE CALCULAITONS FOR 13-415.2, 13-415.2.ABC.1, | | | TABLES 415.2.C.1, AND | | | 415.2.B.1. | | | DEPENDING ON WHAT WORK IS BEING DONE, IT | | | SEEMS THESE REQUIREMENTS FOR LIGHTING | | | CONTROLS ARE REQUIRED AND LPD'S ARE | | | REQUIRED ALSO. | | | | | | 4) NOTE: PLEASE SEE A COUPLE OF OUTSIDE | | | OFFICES IN TENANT SPACE WHICH DO NOT | | | INDICATE ANY LIGHTING?? | | | | | | 5) NOTE: PLEASE SEE BLDG AND POSSIBLE | | | FIRE REVIEW COMMENTS AS THE SEEMS TO | | | SHOW AN EGRESS DOOR ON THE EXIT STAIR | | | TOWERS WHICH OPENS IN. ?? IT IS KNOWN | | | THAT THIS MAY NOT BE A PART OF THIS BLD | | | OUT HOWEVER IF THIS IS SHOWN ON | | | ARCHITECURAL AND MEP PLANS, DOOR SWING | | | SHOULD BE VERIFIED. THIS WAS | | | HIGH-LIGHTED ON PLANS. | | | | | | | | | ** PLEASE SEE ANY COMMENTS WHICH MAY | | | AFFECT THE ELECTRICAL PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-05 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-05 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-10-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-20 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-20 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-07 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-07 |
Time |
15:25 |
Sent To |
E |
|
| Notes |
| 2007-03-07 15:25:43 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-13 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-13 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2007-02-13 09:39:44 | TO "BOB"#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-04 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-04 |
Time |
16:41 |
Sent To |
E |
|
| Notes |
| 2007-01-04 16:42:01 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-19 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-19 |
Time |
16:19 |
Sent To |
E |
|
| Notes |
| 2006-12-19 16:23:09 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-15 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-15 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2006-11-27 16:43:40 | TO "COMM" BD#23 | | 2006-11-15 14:40:32 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-20 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-09-12 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2006-09-25 00:00:00 | TO "COMM" BD#18 | | 2006-09-12 00:00:00 | WAITING FOR "COMM" BD-THIS JOB IS OVER | | | 5000 SQ. FT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-02-28 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-02-28 |
Time |
18:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-21 |
Time |
11:03 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-21 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2007-02-21 11:04:13 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-12-11 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-12-11 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2006-12-11 18:24:55 | PLEASE REFER TO SECTION 601.4 BALANCED RETURN AIR 2004 | | | FBC (M) | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-17 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-17 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-14 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-14 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2006-10-14 10:04:32 | DEMO OF SINK ONLY - NO DEAD ENDS PER 704.5 - PLUMBING | | | PERMIT REQUIRED. |
|
|