| Plan Review Stops For Permit 06090324 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-05 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-05 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2007-07-05 13:58:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)TWO IDENTICAL COLLATED SETS REQUIRED FOR PERMIT | | | ISSUANCE.TWO DISTINCT COLLATED PACKAGES, BOUND | | | (EITHER STAPLED OR WITH A CLIP) SHOULD BE SUBMITTED | | | WITH OLD SHEETS MARKED "VOID" AND SUBMITTED SEPARATELY | | | FROM THE COLLATED PACKAGE.I ATTEMPTED TO STAMP THE | | | SHEETS SHOWING BUILDING APPROVAL BUT WAS UNABLE TO FIND | | | TWO SETS OF SOME OF THE DOCUMENTS.ADDITIONALLY IT IS | | | DIFFICULT TO DETERMINE WHICH SHEETS ARE INTENDED FOR | | | PERMITTING AND WHICH ARE OLD SHEETS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-02 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-02 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-18 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-18 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-18 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-18 |
Time |
09:23 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-23 |
Time |
15:52 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2007-01-23 |
Time |
15:25 |
Sent To |
P |
|
| Notes |
| 2007-01-23 15:52:04 | | | | | | | | | | | | | DENIED | | | | | | THE LOAD CALCULATION FOR THE PANEL SERVED BY THE | | | GENERATOR EXCEEDS THE GENERATOR OUTPUT. NONCOMPLIANT | | | WITH 702.5 CAPACITY AND RATING. AN OPTIONAL STANDBY | | | SYSTEM SHALL HAVE ADEQUATE CAPACITY AND RATING FOR THE | | | SUPPLY OF ALL EQUIPMENT INTENDED TO BE OPERATED AT ONE | | | TIME. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-21 |
Time |
15:21 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-21 |
Time |
14:52 |
Sent To |
P |
|
| Notes |
| 2006-09-21 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE MANUFACTURERS | | | SPECIFICATIONS/RECOMMENDATION, REGARDING | | | CLEARANCES. | | | | | | 2} PROVIDE SPECIFICATIONS FOR THE | | | TRANSFER SWITCH. | | | | | | 3} PROVIDE A CALCULATION FOR THE LOAD | | | BEING SERVED BY THE GENERATOR. SEE | | | 700.15 LOADS ON EMERGENCY BRANCH | | | CIRCUITS. | | | | | | 4} INDICATE HOW THE TRANSFER SWITCH IS | | | FED FROM THE PANEL.THERE MUST BE A | | | MAIN IN THIS PANEL OR OCP IN THE MAIN | | | PANEL. | | | | | | 5} THE PLAN INDICATES A 25 KW GENERATOR | | | AND THE SPECS INDICATE A 20 KW, PLEASE | | | CORRELATE. | | | | | | 6} THE PERSON TAKING RESPONSIBILITY FOR | | | THE PLAN/DRAWINGS, SHALL PRINT AND SIGN | | | THEIR NAME ON THE SHEETS THEY DRAW. | | | PLEASE DO THIS PRIOR TO RESUBMITTING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-02 |
Time |
09:00 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-07-02 |
Time |
09:00 |
Sent To |
M |
|
| Notes |
| 2007-07-02 09:04:55 | DENIED 3RD TIME | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | | MADE ON PREVIOUS REVIEWS. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | | PREVIOUS REVIEW NOTES. | | | | | | A **NO** IS IF THE COMMENT WAS NOT FULLY ADDRESSED | | | AND/OR FURTHER EXPLANATION OR CHANGES IN PLANS OR | | | DOCUMENTS ARE STILL NEEDED. THIS REVIEWER WILL TRY TO | | | BETTER EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | | | AN **OK** WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | | | A **NO/OK** MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | **NOTE: PLEASE ADD THE FOLLOWING INFORMATION ON AN | | | ISOMETRTIC DRAWING** | | | | | | 1. **NO** SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | NOTE: THE RESUBMITTED DRAWING IS NOT AN ISOMETRIC AND | | | DOES NOT CLEARLY SHOW ALL CUT SECTIONS OF PIPE WITH | | | CORRESPONDING LENGTHS. | | | | | | 2. **NO** SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. (OK) | | | | | | 4. **NO** BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. **NO** SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. **NO** INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. (OK) | | | | | | 8. **NO** SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | NOTE: IF NAT. GAS DELIVERY PRESSURE IS 2 PSI PLEASE | | | SUBMIT MANUFACTURER SPECIFICATION SHEETS ON MP | | | REGULATOR. | | | | | | 9. (OK) | | | | | | 10. (OK) | | | | | | 11. (OK) | | | | | | **********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-24 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-01-24 |
Time |
09:54 |
Sent To |
M |
|
| Notes |
| 2007-01-24 10:11:19 | DENIED 2ND TIME | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING CORRECTIONS ARE STILL REQUIRED FROM THE | | | PREVIOUS GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. (OK) | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. (OK) | | | | | | 8. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | NOTE: IF NAT. GAS DELIVERY PRESSURE IS 2 PSI PLEASE | | | SUBMIT MANUFACTURER SPECIFICATION SHEETS ON MP | | | REGULATOR. | | | | | | 9. (OK) | | | | | | 10. (OK) | | | | | | 11. (OK) | | | | | | **********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-27 |
Time |
08:54 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-09-27 |
Time |
08:54 |
Sent To |
B |
|
| Notes |
| 2006-09-27 00:00:00 | ******DENIED****** | | | REFERENCE: FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR GAS PLAN REVIEW ON THE ISOMETRIC | | | DRAWING: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | NOTE: GALVANIZED SCHEDULE 40 METALLIC | | | PIPE SHALL NOT BE INSTALLED UNDER GROUND | | | | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | 8. SUBMIT MANUFACTURE SHEETS AND | | | INSTALLATION INSTRUCTIONS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | 9. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 10. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | 11. FBC-2004 CHAPTER 1,SECTION | | | 106.3.4.2: THE PERSON RESPONSIBLE FOR | | | THE DESIGN OF THE DRAWING SHALL CLEARLY | | | PRINT AND SIGN NAME, AND ALSO DATE | | | DRAWING. PLEASE DO THIS PRIOR TO | | | RESUBMITTING. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-06-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-14 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-14 |
Time |
08:33 |
Sent To |
E |
|
| Notes |
| 2007-06-14 08:34:11 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-11 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-11 |
Time |
15:59 |
Sent To |
Z |
|
| Notes |
| 2007-06-11 16:00:22 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-01-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-16 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-16 |
Time |
17:30 |
Sent To |
E |
|
| Notes |
| 2007-01-16 17:30:38 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-09 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-09 |
Time |
17:36 |
Sent To |
Z |
|
| Notes |
| 2007-01-09 17:37:02 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
15:06 |
Sent To |
E |
|
| Notes |
| 2006-09-18 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-18 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-12 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2006-09-12 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-03 |
Time |
08:08 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-07-03 |
Time |
08:08 |
Sent To |
B |
|
| Notes |
| 2007-07-03 08:11:54 | *** DENIED *** | | | 1) PLEASE SUBMIT TWO IDENTICAL COPIES OF THE SITE | | | PLAN. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-24 |
Time |
15:03 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-01-24 |
Time |
15:03 |
Sent To |
B |
|
| Notes |
| 2007-01-24 15:04:59 | *** DENIED *** | | | 1) SEE ZONING REVIEW, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-20 |
Time |
16:21 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-09-20 |
Time |
16:21 |
Sent To |
E |
|
| Notes |
| 2006-09-20 00:00:00 | *** DENIED *** | | | 1) SEE ZONING REVIEW NOTES AND PLEASE | | | CORRECT. | | | *** NOTICE *** | | | PER 2004 FBC, FUEL GAS - POWERED | | | EQUIPMENT - PERMANENTLY INSTALLED | | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AND NFPA 37. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: | | | 4.1.4ENGINES (GENERATORS) LOCATED | | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. | | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | | THE VENTILATION INTAKES. | | | | | | 2004 FMC 804.3.5 #3, WHERE THE | | | TERMINATION IS LOCATED BELOW AN ADJACENT | | | ROOF STRUCTURE, THE TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | | ROOF STRUCTURE. | | | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | | INTO THE REQUIRED SETBACK, GENERATORS | | | SHALL MAINTAIN THE REQUIRED ABOVE | | | MENTIONED CLEARANCES TO THE ADJACENT | | | PROPERTY STRUCTURES, I.E. FENCE, | | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | | | FOLLOW MANUFACTURE'S RECOMMENDED | | | CLEARANCES AROUND EQUIPMENT FOR | | | SERVICING,AND PROVIDE MANUFACTURE'S | | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | | FOR THE FIELD INSPECTOR. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-06-12 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-06-12 |
Time |
08:20 |
Sent To |
I |
|
| Notes |
| 2007-06-12 08:27:22 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE SETBACK DIMENSIONS OF HIGHLIGHTED | | | AREAS ON SURVEY TO THE PROPERTY LINES.(THE SIDE | | | SETBACK OF PRINCIPAL BUILDING NEXT TO LOT 86, THE | | | SETBACK FROM GENERATOR TO SIDE PROPERTY LINE, SETBACK | | | FROM GENERATOR TO REAR PROPERTY LINE, SETBACK DIMENSION | | | FROM GENERATOR TO FRONT PROPERTY LINE.) | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2007-01-12 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2007-01-12 |
Time |
12:20 |
Sent To |
I |
|
| Notes |
| 2007-01-12 12:25:33 | DENIED. | | | 1. PLEASE SUBMIT A COPY OF THE SURVEY, SITEPLAN | | | SUBMITTED DOES NOT PROVIDE THE SIDE SETBACK (OPPOSITE | | | OF THE PROPOSED GENERATOR). (NOT ALL SETBACKS SHOWN). | | | 2. THE PROPOSED GENERATOR CANNOT BE LOCATED INTO THE | | | 10FT U.E. AND CAN ONLY PROJECT 4FT INTO SETBACK. | | | 3. THE SITPLAN SUBMITTED DOES NOT PROVIDE ALL | | | INFORMATION NEEDED TO COMPLETE REVIEW THE PROPOSED | | | GENERATOR. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-16 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-16 |
Time |
16:34 |
Sent To |
I |
|
| Notes |
| 2006-09-16 00:00:00 | DENIED, | | | 1. THE PROPOSED GENERATOR MUST BE SHOWN | | | ON THE PROPERTY, CANNOT BE LOCATED ON | | | THE NEIGHBORING PROPERTY. | | | 2. THE PROPOSED GENERATOR CANNOT BE | | | LOCATED IN THE 10FT UTILITY EASEMENT IN | | | THE REAR OF THE PROPERTY. | | | 3. NEED TO SHOW THE LOCATION OF THE | | | PROPOSED GENERATOR ON THE PROPERTY WITH | | | SETBACKS (FROM PROPERTY LINE). | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|