| Plan Review Stops For Permit 06090287 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-12-18 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-12-18 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2006-12-18 15:53:26 | DENIED BY BUILDING | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PROJECT IS LOCATED IN AN 'A8' FLOOD | | | ZONE AN ELEVATION CERTIFICATE WILL BE | | | REQUIRED. EQUIPMENT IS REQUIRED TO BE | | | LOCATED 6" ABOVE BASE FLOOD ELEVATION. | | | | | | 3)AN INTERNAL PRESSURE COEFFICENT OF + / - 0.18 IS | | | SPECIFIED ON THE PLANS. THIS INDICATES THAT THIS IS AN | | | ENCLOSED STRUCTURE, WHICH IT IS NOT. PLEASE CORRECT. | | | SEE FBC 1603.1.4 AND ASCE 7-02. | | | | | | 4) SUBMIT THE MANUFACTURES SPECIFICATIONS INDICATING | | | THE ATTACHMENTS OF THE EQUIPMENT TO THE CONCRETE PAD. | | | FBC 1609.1.3. | | | | | | 5) SEE COMMENTS OF OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-10-03 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-10-03 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | DENIED BY BUILDING | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PROJECT IS LOCATED IN AN 'A8' FLOOD | | | ZONE AN ELEVATION CERTIFICATE WILL BE | | | REQUIRED. EQUIPMENT IS REQUIRED TO BE | | | LOCATED 6" ABOVE BASE FLOOD ELEVATION. | | | | | | 3) SPECIFY THE EDITIONS OF THE FLORIDA | | | BUILDING CODE THAT APPLY TO THIS | | | PROJECT. AS WELL AS THE OTHER CODES THAT | | | APPLY (SUCH AS NEC). | | | | | | 4) SPECIFY THE BASIC WIND SPEED FOR THIS LOCATION. | | | | | | 5) THE EQUIPMENT IS REQUIRED TO TO BE | | | ANCHORED TO RESIST OVERTURNING, UPLIFT | | | AND SLIDING. | | | | | | 6) SEE COMMENTS OF OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-17 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-17 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2006-12-17 14:15:22 | *** UNSAT 2ND REVIEW *** | | | | | | | | | 1) NOTE: PLEASE SEE COMMENTS FROM PREVIOUS REVIEW DONE | | | BY BILL TROBAUGH AND MYSELF. PLEASE SUBMIT THE | | | ELECTRICAL INFORMATION AS PREVIOUSLY REQUESTED. PLEASE | | | KNOW THE INSTALLATION CAN NOT BE APPROVED UNTIL PROPER | | | VERIFICATION OF ELECTRICAL CAN BE DONE TO SEE IF THERE | | | IS ADEQUATE SPACE AND ELECTRICAL FOR EQUIPMENT BEING | | | PROPOSED. | | | THIS MUST BE VERIFIED AT THIS TIME. | | | PLEASE SUBMIT THE MANUFACTURE SPECS/CUT SHEETS FOR | | | EQUIPMENT BEING INSTALLED. 90.7, 110.3 | | | PLEASE INDICATE CIRCUITING WHERE EQUIPMENT IS BEING FED | | | FROM, PLEASE INDICATE EXISTING LOAD AND NEW LOAD BEING | | | ADDED. | | | PLEASE INDICATECONDUCTORS, SIZES ETC. | | | 240.4, 310.16, 408.4,220, | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-30 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-30 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2006-09-30 00:00:00 | | | | | | | ** PLEASE ALSO SEE COMMENTS FROM BILL | | | TROBAUGH. | | | | | | 1) NOTE: PLEASE ALSO SEE FS 481.229, | | | PLANS MAY NOT BE DONE BY A "DESIGNER", | | | MUST BE A MINIMUMOF AN ARCHITECT OR | | | ENGINEER. | | | TITLE BLOCK FOR A DESIGNER OFFERING | | | THESE SERVICES IS NOT PERMITTED UNDER FS | | | 481.203,481.223, 481.229 | | | | | | 2) NOTE: PLEASE SEE ADDRESS OF THE | | | LOCATION OF PROJECT SHALL CLEARLRY BE | | | STATED IN TITLE BLOCK. | | | FAC 61G1-16.004, FAC 61G15-23.002 | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE | | | CONTACT THE FLORIDA BOARD OF ARCHITECT'S | | | LEGAL COUNSEL. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-27 |
Time |
18:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-27 |
Time |
18:15 |
Sent To |
ENG |
|
| Notes |
| 2006-09-30 00:00:00 | | | 2006-09-27 00:00:00 | | | | | | | NONCOMPLIANT/INCOMPLETE | | | | | | PLEASE INDICATE THE DESIGNATION, | | | LOCATION AND CIRCUIT NUMBERS,FOR THE | | | PANEL FEEDING THE "MAIN POWER DISCONNECT | | | BOX" SHOWN ON THE PLAN. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-06 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-06 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2006-10-06 00:00:00 | TALKED TO LUIS M., ENG REVIEW NOT | | | REQUIRED, BECAUSE IT IS A PRIVATE | | | PROPERTY & THERE IS NO STORM WATER | | | INVOLVED, ETC FOR ENG REVIEW. | | | | | | RASIK CHOKSHI | | 2006-09-27 00:00:00 | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-30 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-30 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2006-12-13 14:54:35 | TO "COMM" BD#11 | | 2006-11-30 11:28:41 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-29 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-29 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2006-09-30 00:00:00 | TO COMM BOAR #2 | | 2006-09-29 00:00:00 | WAITING FOR "COMM" BD-PLANS GO ON "COMM" | | | BD FOR PLUM AND BLDG PER "LMARTINEZ" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
14:56 |
Sent To |
E |
|
| Notes |
| 2006-09-18 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-13 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-11 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-01-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-16 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-16 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2007-01-16 18:59:30 | DENIED | | | REFERENCES: FBC-2004 CHAPTER 1 | | | FBC-2004 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ***FROM PREVIOUS REVIEW: | | | | | | 1. PLEASE INDICATE WHAT TYPE OF EQUIPMENT WILL BE | | | WASHED AT THE WASH PIT. SECTION106.1.1. | | | ****NO RESPONSE, NOT ADDRESSED. | | | | | | 2. MORE INFORMATION IS REQUIRED. WILL THE SYSTEM BE | | | CONNECTED TO A POTABLE WATER SOURCE OR A SANITARY | | | DRAINAGE SYSTEM? SECTION 106.1.1. IF THE SYSTEM IS | | | CONNECTED TO THE POTABLE WATER, AN RPZV BACKFLOW WILL | | | BE REQUIRED. SECTION 608.13.2. | | | ****NO RESPONSE, NOT ADDRESSED. | | | | | | 3. PLANS INDICATE AN OIL TRAP. PLEASE CONTACT LYNN | | | MASSON, ENVIRONMENTAL COMPLIANCE TO SEE IF AN OIL | | | INTERCEPTOR WILL BE REQUIRED IF THE SYSTEM WILL BE | | | CONNECTED TO THE SANITARY SEWER SYSTEM. (561) 822-2271, | | | OR FAX (561) 822-2279, OR E-MAIL [email protected]. WASTE | | | ORD. #3434. IF THE SYSTEM IS NOT CONNECTED TO THE SANT. | | | SEWER, PLEASE INDICATE HOW THE OIL WILL BE DISPOSED. | | | SECTION 106.1.1. | | | ****NO RESPONSE, NOT ADDRESSED. | | | | | | 4. INDICATE HOW THE SLUDGE WILL BE DISPOSED. SECTION | | | 106.1.1. | | | ****NO RESPONSE, NOT ADDRESSED. | | | | | | 5. OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6713 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-13 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-13 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2006-10-13 17:45:41 | DENIED | | | REFERENCES: FBC-2004 CHAPTER 1 | | | FBC-2004 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. PLEASE INDICATE WHAT TYPE OF EQUIPMENT WILL BE | | | WASHED AT THE WASH PIT. SECTION106.1.1. | | | | | | 2. MORE INFORMATION IS REQUIRED. WILL THE SYSTEM BE | | | CONNECTED TO A POTABLE WATER SOURCE OR A SANITARY | | | DRAINAGE SYSTEM? SECTION 106.1.1. IF THE SYSTEM IS | | | CONNECTED TO THE POTABLE WATER, AN RPZV BACKFLOW WILL | | | BE REQUIRED. SECTION 608.13.2. | | | | | | 3. PLANS INDICATE AN OIL TRAP. PLEASE CONTACT LYNN | | | MASSON, ENVIRONMENTAL COMPLIANCE TO SEE IF AN OIL | | | INTERCEPTOR WILL BE REQUIRED IF THE SYSTEM WILL BE | | | CONNECTED TO THE SANITARY SEWER SYSTEM. (561) 822-2271, | | | OR FAX (561) 822-2279, OR E-MAIL [email protected]. WASTE | | | ORD. #3434. IF THE SYSTEM IS NOT CONNECTED TO THE SANT. | | | SEWER, PLEASE INDICATE HOW THE OIL WILL BE DISPOSED. | | | SECTION 106.1.1. | | | | | | 4. INDICATE HOW THE SLUDGE WILL BE DISPOSED. SECTION | | | 106.1.1. | | | | | | 5. PLEASE SEE COMMENTS BY DEWEY PALMER CONCERNING THE | | | FLORIDA ADMINISTRATIVE CODE AND FLORIDA STATUTES | | | PERTAINING TO THE DESIGNER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6713 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2007-01-17 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2007-01-17 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-16 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-16 |
Time |
15:48 |
Sent To |
I |
|
| Notes |
|
|