Plan Review Details - Permit 06090267
| Plan Review Stops For Permit 06090267 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-28 |
Time |
13:50 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-28 |
Time |
13:50 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-15 |
Time |
15:18 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-15 |
Time |
15:18 |
Sent To |
PC |
|
| Notes |
| 2006-09-15 00:00:00 | ******DENIED****** | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR GAS PLAN REVIEW: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | NOTE: THIS INCLUDES THE EXISTING SYSTEM | | | AS WELL AS THE PROPOSED SYSTEM IN ORDER | | | TO VERIFY THE LONGEST LENGTH. | | | | | | 2. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | NOTE: NEED BTU LOAD OF EXISTING SYSTEM | | | AS WELL AS THE PROPOSED. | | | | | | 3. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | NOTE: THIS INCLUDES THE EXISTING SYSTEM | | | AS WELL AS THE PROPOSED. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
17:37 |
Sent To |
G |
|
| Notes |
| 2006-09-23 00:00:00 | TO "G" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-15 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-09-11 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | TO "G" BOX |
|
|
|