Plan Review Details - Permit 06090202
Plan Review Stops For Permit 06090202
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-04-06 Cont ID  
Sent By lmartine Date 2007-04-06 Time 09:10 Rev Time 0.00
Received By lmartine Date 2007-04-06 Time 09:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-03-09 Cont ID  
Sent By btrobaug Date 2007-03-09 Time 16:37 Rev Time 0.25
Received By btrobaug Date 2007-03-09 Time 16:35 Sent To PC
Notes
2007-03-09 16:36:51 
  
 NO CHANGE IN THE PERMITTED SLAB, OK PER LM./WRT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-10-18 Cont ID  
Sent By alange Date 2006-10-18 Time 08:19 Rev Time 0.00
Received By alange Date 2006-10-18 Time 08:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-03-09 Cont ID  
Sent By btrobaug Date 2007-03-09 Time 14:02 Rev Time 0.50
Received By btrobaug Date 2007-03-09 Time 13:36 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-09-15 Cont ID  
Sent By btrobaug Date 2006-09-15 Time 08:14 Rev Time 0.50
Received By btrobaug Date 2006-09-15 Time 06:24 Sent To M
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-09-20 Cont ID  
Sent By mperson Date 2006-09-20 Time 15:26 Rev Time 0.00
Received By mperson Date 2006-09-20 Time 15:25 Sent To B
Notes
2006-09-20 00:00:00NOTE: GAS FOR GENERATOR ON CLOSED PERMIT
 #05100467 WHICH REPLACED EXPIRED PERMIT
 #03090559

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-04-04 Cont ID  
Sent By spalmer Date 2007-04-04 Time 17:33 Rev Time 0.00
Received By spalmer Date 2007-04-04 Time 17:33 Sent To M
Notes
2007-04-04 17:34:27TO TOM GORDON

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-03-27 Cont ID  
Sent By spalmer Date 2007-03-27 Time 18:20 Rev Time 0.00
Received By spalmer Date 2007-03-27 Time 18:20 Sent To Z
Notes
2007-03-27 18:21:02TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-03-05 Cont ID  
Sent By adarroug Date 2007-03-05 Time 10:30 Rev Time 0.00
Received By adarroug Date 2007-03-05 Time 10:30 Sent To E
Notes
2007-03-05 10:31:04TO "BTROBAUGH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-26 Cont ID  
Sent By adarroug Date 2007-02-26 Time 08:51 Rev Time 0.00
Received By adarroug Date 2007-02-26 Time 08:51 Sent To Z
Notes
2007-02-26 08:51:50TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-09-14 Cont ID  
Sent By adarroug Date 2006-09-14 Time 14:30 Rev Time 0.00
Received By adarroug Date 2006-09-14 Time 14:30 Sent To E
Notes
2006-09-14 00:00:00TO "GEN-RES" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-18 Cont ID  
Sent By alange Date 2006-10-18 Time 08:19 Rev Time 0.00
Received By alange Date 2006-09-08 Time 18:52 Sent To  
Notes
2006-09-08 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-04-05 Cont ID  
Sent By tgordon Date 2007-04-05 Time 08:14 Rev Time 0.20
Received By tgordon Date 2007-04-05 Time 08:14 Sent To B
Notes
2007-04-05 08:15:59REVISION TO RELOCATE GEN.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-03-09 Cont ID  
Sent By btrobaug Date 2007-03-09 Time 16:31 Rev Time 0.15
Received By tgordon Date 2007-03-09 Time 16:15 Sent To B
Notes
2007-03-09 16:16:10REVISION (GEN. LOCATION).

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-09-18 Cont ID  
Sent By tgordon Date 2006-09-18 Time 14:24 Rev Time 0.15
Received By tgordon Date 2006-09-18 Time 14:24 Sent To P
Notes
2006-09-18 00:00:00*** PROVISO ***
 1) PER 2004 FBC, FUEL GAS - POWERED
 EQUIPMENT - PERMANENTLY INSTALLED
 EQUIPMENT POWERED BY INTERNAL COMBUSTION
 ENGINES SHALL BE INSTALLED IN ACCORDANCE
 WITH MANUFACTURE'S INSTALLATION
 INSTRUCTIONS AND NFPA 37.
  
 NFPA 37 INSTALLATION & USE OF STATIONARY
 COMBUSTION ENGINES & GAS TURBINES:
 4.1.4ENGINES (GENERATORS) LOCATED
 OUTDOORS SHALL BE MINIMUM OF 5 FT FROM
 OPENINGS IN WALLS & AT LEAST 5 FT FROM
 STRUCTURES HAVING COMBUSTIBLE WALLS.A
 MINIMUM CLEARANCE IS NOT REQUIRED WHEN
 (1) THE ADJACENT WALL HAS A MINIMUM FIRE
 RESISTANCE RATING OF 1 HOUR OR (2) THE
 WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF
 NON-COMBUSTIBLE MATERIALS, AND IT HAS
 BEEN DEMONSTRATED THAT A FIRE WITHIN THE
 ENCLOSURE WILL NOT IGNITE COMBUSTIBLE
 MATERIALS OUTSIDE THE ENCLOSURE.
 INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS
 SHOULD NOT TERMINATE UNDER STRUCTURES OR
 WHERE THE EXHAUST MIGHT BE DRAWN INTO
 THE VENTILATION INTAKES.
  
 2004 FMC 804.3.5 #3, WHERE THE
 TERMINATION IS LOCATED BELOW AN ADJACENT
 ROOF STRUCTURE, THE TERMINATION POINT
 SHALL BE LOCATED AT LEAST 3 FT FROM THE
 ROOF STRUCTURE.
  
 PLEASE NOTE, WHILE ZONING ALLOWS
 MECHANICAL EQUIPMENT TO ENCROACH 4 FT
 INTO THE REQUIRED SETBACK, GENERATORS
 SHALL MAINTAIN THE REQUIRED ABOVE
 MENTIONED CLEARANCES TO THE ADJACENT
 PROPERTY STRUCTURES, I.E. FENCE,
 BUILDING, WINDOWS, DOORS, OR OPENINGS.
  
 FOLLOW MANUFACTURE'S RECOMMENDED
 CLEARANCES AROUND EQUIPMENT FOR
 SERVICING,AND PROVIDE MANUFACTURE'S
 INSTALLATION INSTRUCTIONS AT THE JOBSITE
 FOR THE FIELD INSPECTOR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop Z ZONING
Rev No 3 Status P Date 2007-04-03 Cont ID  
Sent By adavila Date 2007-04-03 Time 15:27 Rev Time 0.00
Received By LFRANCO Date 2007-04-03 Time 15:28 Sent To I
Notes
2007-04-03 15:28:12PLANNING AND ZONING DEPARTMENT
  
 GENERATOR PERMIT ONLY.
  
 APPLICANT SHALL APPLY FOR A SEPERATE WALL PERMIT.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-03-02 Cont ID  
Sent By adavila Date 2007-03-02 Time 17:24 Rev Time 0.00
Received By adavila Date 2007-03-02 Time 14:50 Sent To I
Notes
2007-03-02 17:24:47PER LINDA MIA FRANCO, SENIOR PLANNER.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-09-12 Cont ID  
Sent By mmclean Date 2006-09-12 Time 16:16 Rev Time 0.00
Received By mmclean Date 2006-09-12 Time 16:16 Sent To I
Notes
2006-09-12 00:00:00EXPIRED PERMIT 05082087