Plan Review Details - Permit 06082250
| Plan Review Stops For Permit 06082250 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-09-19 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-09-18 |
Time |
18:17 |
Sent To |
PC |
|
| Notes |
| 2006-09-18 00:00:00 | | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | | | | 1) 2004 FL. BLD CODE 1603.1.4 THE | | | FOLLOWING INFORMATION RELATED TO WIND | | | SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 2) THE DETAIL SHEETS ARE MISSING FROM | | | THE PACKAGE. SUBMIT THE DETAIL SHEETS | | | WHICH SHOW THE CONNECTION DETAILS OF THE | | | NEW FLEX AWNINGS AND THE NEW BULLNOSE. | | | | | | 3)THE COVER SHEET HAS A DRAWING INDEX, | | | HOWEVER, SOME THE SHEETS MENTIONED ON | | | THE DRAWING INDEX WERE NOT SUBMITTED. | | | ALL THOSE SHEETS MENTIONED ON THE COVER | | | NEEDS TO BE SUBMITTED WITH THIS PACKAGE | | | OR REMOVE THAT INDEX SHEET. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-14 |
Time |
16:13 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2006-09-14 |
Time |
16:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-14 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-14 |
Time |
14:23 |
Sent To |
E |
|
| Notes |
| 2006-09-14 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-12 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-12 |
Time |
16:44 |
Sent To |
I |
|
| Notes |
| 2006-09-12 00:00:00 | DENIED, CPD | | | 1. MUST APPLY FOR A MINOR AMENDMENT WITH | | | THE PLANNING & ZONING DEPT FOR THE | | | CHANGE IN THE ELEVATION (CHANGE OF THE | | | BULLNOSE ON STRUCTURE). | | | 2. PLEASE CONTACT A PLANNER AT 822-1435, | | | PLANNING & ZONING DEPT, 5TH FLOOR, CITY | | | HALL. | | | |
|
|
|