| 2006-09-15 00:00:00 | |
| | |
| | DENIED |
| | |
| | 1) PROVIDE INFORMATION ON THE "FLEXIBLE |
| | COVERING" IF FABRIC IT SHALL BE FLAME |
| | RESISTANT PER NFPA 701 AND 3105.1.1.5 |
| | FBC (PROVIDE CERTIFICATE) |
| | |
| | 2) AWNINGS SHALL BE DESIGNED SO THAT |
| | FABRIC OR MEMBRANE COVER CAN BE QUICKLY |
| | AND EASILY REMOVED PER 3105.4.2.1 |
| | TIGHTLY WRAPED OR WOVEN CORDS ARE |
| | ACCEPTABLE WHEN 2 COPIES OF A DETAILED |
| | INSTRUCTION GUIDE FOR REMOVAL ARE |
| | INCLUDED IN THE SUBMITTAL. |
| | IN ADDITION 2 COPIES OF A NOTORIZED |
| | LETTER OF INTENT TO REMOVE AT 75 MPH ARE |
| | REQUIRED.THESE REQUIREMENT ARE NOT |
| | NECESSARY IF THE DESIGN IS NON REMOVABLE |
| | AND MEETS THE DESIGN WIND LOADS |
| | |
| | 3) THE CLAIMED VALUATION ON THE PERMIT |
| | APPLICATION IS LOW. FOR PERMITTING |
| | PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT |
| | COST EXCLUDING LAND VALUE. OUR VALUATION |
| | REFERENCE IS ICC (BVD), MARSHALL-SWIFT |
| | AND MEANS COST ANALYSIS SERVICES PER |
| | 108.3 FBC* |
| | |
| | 4) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MAY BE REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED IF VALUE IS |
| | ADJUSTED |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |