| Plan Review Stops For Permit 06082188 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-10-16 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-10-16 |
Time |
11:46 |
Sent To |
PC |
|
| Notes |
| 2006-10-16 11:49:43 | USE THIS PCN SINCE A UNITY OF TITLE TOOK PLACE BETWEEN | | | THE FOLLOWING PCN'S : | | | 74434309110000080, 74434309110000090 AND | | | 74434309110000100.THE LOWEST PCN ...0080 WAS KEPT THE | | | REST ARE INACTIVE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
20 |
Status |
P |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-27 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-27 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2008-06-27 11:35:58 | REVISED ENERGY CALCS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
F |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-05-27 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-05-27 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2008-05-27 15:05:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.PER FBPE, ALL ENGINEERS' SIGNATURES ARE TO BE | | | ORIGINAL, "WET" SIGNATURES (CANNOT BE A STAMP). | | | HOWEVER, IT APPEARS THAT ALL DOCUMENTS WITHIN THE | | | BINDER SUBMITTED ARE REPORTS RATHER THAN | | | SPECIFICATIONS, PLANS, PRINTS, OR CALCULATIONS.IF ALL | | | OF THE DOCUMENTS ARE REPORTS, THE FOLLOWING MAY APPLY | | | PER FAC61G15-23.002(2):ENGINEERING REPORTS MUST BE | | | SIGNED, SEALED AND DATED ON A SIGNATURE PAGE OR COVER | | | LETTER BY EACH PROFESSIONAL ENGINEER WHO IS IN | | | RESPONSIBLE CHARGE OF ANY PORTION OF THE REPORT. | | | | | | THIS MAY BE ACCOMPLISHED BY PROVIDING A SIGNED, SEALED, | | | AND DATED COVER LETTER TO BE INCORPORATED INTO THE | | | BINDER OF REPORTS. | | | | | | IF THE DOCUMENTS SUBMITTED INCLUDE SPECIFICATIONS OR | | | PLANS (ANYTHING OTHER THAN A REPORT), A SIGNED, SEALED, | | | AND DATED INDEX SHEET MAY BE PROVIDED IN LIEU OF | | | PROVIDING AN ORIGINAL SIGNATURE FOR EACH SEALED SHEET. | | | | | | OTHER OPTIONS MAY ALSO BE ACCEPTABLE (SUCH AS SIGNING | | | EACH SEALED SHEET) PROVIDED THAT WHATEVER OPTION | | | PROPOSED IS IN COMPLIANCE WITH FAC61G15-23.I HAVE | | | SUGGESTED THE OPTION WHICH APPEARS TO BE THE SIMPLEST | | | BUT THE DECISION AS TO HOW TO COMPLY IS ENTIRELY THE | | | ENGINEER'S DECISION.ANY COMPLIANT METHOD IS | | | ACCEPTABLE. | | | | | | 2.PLEASE HAVE THE DESIGNER OF RECORD (EITHER | | | ARCHITECT OR ENGINEER) REVIEW THE DOCUMENTS PRIOR TO | | | RESUBMITTAL.THIS IS REQUIRED FOR ALL SUBMITTALS AND | | | MAY BE DONE BY EITHER A SHOP DRAWING REVIEW STAMP OR BY | | | LETTER. | | | | | | 3.PLEASE INCLUDE THE CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR THE ENGINEERING BUSINESS, ECS FLORIDA LLC, | | | ON EACH SHEET WHICH IS REQUIRED TO BE SIGNED AND SEALED | | | (INCORPORATED AS TITLE BLOCK INFORMATION). | | | | | | 4.PLEASE NOTE THAT THE REPAIR DETAIL (SHEETS | | | SK4.10-05 AND -03) PREPARED BY BLISS & NYITRAY, INC. IS | | | A SPECIFICATION, AND BASED ON PREVIOUS PLAN REVIEW | | | NOTES, ARE NOT INCORPORATED INTO OUR PLAN SET.PLEASE | | | PROVIDE ORIGINALS AS A REVISION UNLESS THIS HAS ALREADY | | | BEEN DONE.THIS COMMENT APPLIES TO ANY OTHER SHEETS | | | WHICH MAY HAVE BEEN INCLUDED WHICH HAVE THE SAME | | | SITUATION BUT WERE NOT SPECIFICALLY LISTED IN THIS | | | COMMENT. | | | | | | 5.AS THIS DOCUMENT IS A SUBMITTAL (PER BUILDING | | | INSPECTOR'S REQUREST), PLEASE NOTE THAT A COMPLETE PLAN | | | REVIEW OF EACH SHEET WAS NOT PERFORMED.THE REPORTS | | | SUBMITTED WERE SPOT CHECKED FOR GENERAL COMPLIANCE WITH | | | THE CODE AND DESIGNERS' INTENT (ADVISORY, NO ACTION | | | REQUIRED). | | | | | | 6.SOME SHEETS REFER TO NONCOMPLIANCE, OTHERS APPEAR | | | NONCOMPLIANT.IT APPEARS THAT ALL REPORTS WERE | | | SUBMITTED, AND THE NONCOMPLIANCE ADDRESSED IN | | | SUBSEQUENT INSPECTIONS.PLEASE PROVIDE A LETTER FROM | | | BOTH THE ENGINEERING COMPANY AND THE CONTRACTOR WHICH | | | ATTEST GENERALLY TO THE FACT THAT ANY NON COMPLIANCE | | | NOTED IN ANY OF THE REPORTS HAS BEEN ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
P |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-05-02 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-05-02 |
Time |
17:45 |
Sent To |
PC |
|
| Notes |
| 2008-05-02 17:46:52 | REVISION #6 DATED 4/22/08; SHEETS S1.1, 1.2, 1.3, 1.4, | | | 2.1, 2.2., 2.3,3.1,4.1, 4.2, 4.3, 4.4, 4.5, 4.6, 4.7, | | | 4.8 AND NEW SHEETS 4.9, 4.10, 4.11, 4.12 | | | | | | **PROVISO**REVISE COVER SHEET TO REFLECT CURRENT | | | REVISION NUMBER (6) AND NEW SHEETS S4.9 THRU 4.12 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-28 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-28 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2008-04-28 15:28:49 | STAIR SHOPS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
P |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-10 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-10 |
Time |
18:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
F |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-07 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-07 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2008-03-07 16:21:26 | ****CORRECTIONS**** | | | ****STAIR SHOPS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.SEE FBC11-4.9.4(2), FBC1009.11.5 REGARDING HANDRAIL | | | EXTENSIONS.MOST OF THE RAILS SHOWN ON THE PLAN WHICH | | | ARE NOT CONTINUOUS ARE NOT COMPLIANT. | | | | | | 2.SEE FBC FIGURE 8 (C-1).DOES THIS APPLY TO ANY OF | | | THE STAIRS?IF IT DOES, AND PROTECTION FROM OVERHEAD | | | HAZARDS IS TO BE PROVIDED BY THE SAME COMPANY AS THE | | | STAIRS, PLEASE INCLUDE IN THIS SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
P |
Date |
2008-03-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-07 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-07 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2008-03-07 14:56:50 | REVISION, NEW SHEET S4.12 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-28 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-28 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2007-12-28 09:44:19 | ****CORRECTIONS**** | | | STAIR RAILING SHOPS | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.HANDRAIL EXTENSIONS IN COMPLIANCE WITH | | | FBC11-4.9.4(2), FBC1009.11.5.NO DIMENSIONS ARE SHOWN | | | AND, WHEN SCALED, DO NOT COMPLY. | | | | | | 2.HANDRAIL EXTENSIONS ARE TO RETURN TO A WALL, GUARD, | | | WALKING SURFACE, OR CONTINUOUS IN ACCORDANCE WITH | | | FBC1009.11.5.SEE ALSO FBC11-4.9.4(6). | | | | | | 3.SUBMITTALS/SHOP DRAWINGS ARE TO BE REVIEWED BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL TO THE CITY. NOTE | | | THAT IF THE SHOP DRAWINGS DO NOT CORRELATE WITH THE | | | PERMIT PLANS, A REVISION WILL BE REQUIRED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
F |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-12-27 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-12-27 |
Time |
18:58 |
Sent To |
|
|
| Notes |
| 2007-12-27 18:59:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.TWO COLLATED SETS REQUIRED.ONLY ONE SET WAS | | | SUBMITTED OF SOME OF THE SHEETS. | | | | | | 2.ALL CHANGES TO THE PLAN, INCLUDING DETAILS, SHOULD | | | BE SUBMITTED AS REVISIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-08 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-08 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2007-11-08 09:50:30 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)THE CERTIFICATE OF AUTHORIZATION FOR THE | | | ARCHITECTURE FIRM IS TO BE PRINTED ON EACH SHEET, | | | FAC61G16-23.002, 003. | | | | | | 2.)WHEN RESUBMITTING, PLEASE SUBMIT AS A REVISION. | | | CHANGES TO THE PLAN, WHETHER THEY BE ACTUAL CHANGES IN | | | DESIGN OR DETAILS ORIGINALLY OMITTED BY THE ARCHITECT | | | OR ENGINEER, ARE REVISIONS.ONLY SHOP DRAWINGS CAN BE | | | SUBMITTED AS SUBMITTALS, AS THEY DO NOT CONTAIN ANY NEW | | | INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-30 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-30 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2007-10-30 12:02:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.ALL SUBMITTALS ARE TO BE REVIEWED BY DESIGNER OF | | | RECORD (ARCHITECT OR ENGINEER) PRIOR TO SUBMITTAL. | | | | | | 2.PLEASE DISCUSS WITH INSPECTOR WHETHER OR NOT THE | | | SUBMITTALS ARE REQUIRED TO BE SUBMITTED THROUGH PLAN | | | REVIEW. | | | | | | 3.ALL SIGNATURES FOR THE ENGINEER ARE TO BE ORIGINALS | | | (NO STAMPS) PER FBPE. | | | | | | 4.ALL INFORMATION REQUIRED BY FAC61G15-23.002 IS TO | | | BE ON EACH SHEET (TITLE BLOCK, ENGINEER). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-29 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-29 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2007-10-29 10:26:57 | REISION, S4.9, S4.10, SK4.6-01,SK4.5-04,SK4.5-05 DATED | | | 10/11/7 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-26 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-26 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2007-09-26 13:40:15 | REVISION (PRODUCT APPROVAL) AND SHOP DRAWINGS OK | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-14 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-14 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2007-09-14 09:44:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)THE STOREFRONT PRODUCT APPROVAL 05-0317.03 IS NOT | | | THE ONE REVIEWED BY DESIGNER OF RECORD (06-1019.08). | | | IF YOU WISH TO CHANGE PRODUCTS, SUBMIT AS A REVISION | | | AFTER REVIEW BY DESIGNER OF RECORD. | | | | | | 2.)THE NOAS SUBMITTED REQUIRE ENGINEERING ANALYSIS | | | DUE TO DESIGN WITH A 33% STRESS INCREASE WHICH IS NO | | | LONGER ALLOWED UNDER FBC2004.06-1019.08 PREVIOUSLY | | | REVIEWED BY DOR IS COMPLIANT AND DOES NOT REQUIRE THIS | | | ANALYSIS.PLEASE HAVE THE ENGINEER REVISE THE SHOP | | | DRAWINGS TO INDICATE THAT HE HAS REVIEWED ANCHORING | | | WITHOUT THE 33% STRESS INCREASE.SEE THE FLORIDA STATE | | | PRODUCT APPROVAL FOR PRODUCT 04-0227.02 AND SEE THE | | | NOAS WHICH STATE THAT A STRES INCREASE WAS USED IN | | | ANCHOR DESIGN. | | | | | | 3.)SHEET 4A STATES THAT DOOR 202.1 AND FRAME WILL BE | | | NONIMPACT.IS THIS AN INTERIOR DOOR? | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-14 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-14 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2007-09-14 09:33:15 | NEW ENERGY CALCS PROCESSED BY LUIS MARTINEZ 5/21/07 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-13 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-13 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2007-06-13 08:52:10 | STRUCTURAL CONCRETE CALCS AND SHOPS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2007-05-03 11:26:36 | **PROVISO** | | | | | | 1.)MECHANICAL ENGINEER TO MAIL DOCUMENTS REGARDING SF | | | AREA ON ENERGY CALCS.IF THIS DOES NOT SHOW CODE | | | COMPLIANCE, NEW ENERGY CALCS WILL BE REQUIRED. | | | | | | | | | | | | ***NOTE*** | | | | | | NOC, IMPACT FEES, SOILS WITH FOUNDATION PERMIT | | | 07030280 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-04-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-29 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-29 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2007-04-29 14:43:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 | | | RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | | | | FROM PREVIOUS LIST: | | | | | | 1.-4.)ADDRESSED. | | | | | | 5.)SEPARATE PERMIT REQUIRED FOR THE | | | DUMPSTER ENCLOSURE.PLEASE COMPLETE A | | | PERMIT APPLICATION; SEPARATE PLANS ARE | | | NOT REQUIRED. | | | | | | 6-10.)ADDRESSED. | | | | | | 11-28.)ADDRESSED. | | | | | | 29.)SEE ELECTRIC COMMENTS REGARDING THE ENERGY CALCS. | | | ALSO PLEASE CLARIFY CONFLICT BETWEEN THE SQUARE FOOT | | | AREA ON THE PLAN AND THE ENERGY CALC SQUARE FOOT AREA. | | | | | | 3RD REVIEW - THE RESPONSE LETTER STATES THAT CROSS | | | WALLS ARE EXCLUDED.SEE DEFINITION OF BUILDING AREA IN | | | CHAPTER 13.AREA IS TO MEASURED FROM OUTSIDE FACE TO | | | OUTSIDE FACE OF EXTERIOR WALLS; WHERE IN THE CODE DOES | | | IT ALLOW EXCLUSION OF WALLS?ALSO THE ENERGY CALCS | | | HAVE A "FAILED" STATUS, MUST SAY "PASSED". | | | | | | 30.)NEW COMMENT:DUE TO POLICY CHANGE, PLEASE SUBMIT | | | ALL REQUIRED PRODUCT APPROVALS FOR ALL COMPONENTS & | | | CLADDING.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO EVALUATION REPORTS, FAC9B72, | | | WWW.FLORIDABUILDING.ORG | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-26 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-21 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2007-02-26 09:45:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 | | | RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | | | | 1.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.-4.)ADDRESSED. | | | | | | 5.)SEPARATE PERMIT REQUIRED FOR THE | | | DUMPSTER ENCLOSURE.PLEASE COMPLETE A | | | PERMIT APPLICATION; SEPARATE PLANS ARE | | | NOT REQUIRED. | | | | | | 6-10.)ADDRESSED. | | | | | | 11.)SEE FBC313, FBC406.1.FROM PREVIOUS LIST, | | | PENETRATIONS TO BE IN COMPLIANCE WITH FBC M712 | | | (M1-01-101).THE EXHAUST FAN LOUVER IS NOT IN | | | COMPLIANCE.HOWEVER, AFTER FIRTHER DISCUSSION WITH | | | HAROLD MOSER, CHIEF MECHANICAL INSPECTOR, THE EXHAUSE | | | SHOULD DISCHARGE TO THE OUTSIDE, FBC MECHANICAL 501.2. | | | | | | | | | 1 HOUR OCCUPANCY VERTICAL SEPARATION IS SHOWN BETWEEN | | | THE GARAGE AND BUSINESS AREA; PLEASE SHOW HORIZONTAL | | | SEPARATION BETWEEN THE FIRST AND SECOND FLOOR, EITHER | | | TESTED ASSEMBLY OR CALCULATED FIRE RESISTANCE. | | | | | | 12-16.)ADDRESSED. | | | | | | 17.)SECTION 2-A6-00-101, THE STAIR | | | RAIL IS TO EITHER BE ROUNDED OR RETURN | | | TO THE FLOOR, WALL, OR POST.A STRAIGHT | | | EXTENSION IS SHOWN. | | | | | | SECOND REVIEW; THE STAIR RAILING DETAIL ISN'T CLEAR. | | | HANDRAIL AND GUARDRAIL ARE REQUIRED FBC1012.1, | | | FBC1009.11.ONLY ONE RAIL IS SHOWN.IT APPEARS THAT | | | THE RAILING EXTENSION IS NOT ROUNDED, SEE FBC11 FIGURE | | | 19. | | | | | | 18.)SECTION 2-A6-00-101, THE AREA | | | UNDER THE STAIR LACKS THE HEADROOM | | | REQUIRED BY FBC11-4.4.2, BARRIER | | | REQUIRED. | | | | | | 19.-22.)ADDRESSED. | | | | | | 23.)STRUCTURALS STATE THAT MRH IS | | | 24FT.NOTE THAT THE STAIR ROOF IS AT APPROXIMATELY | | | 37FT.DESIGN PRESSURES | | | APPEAR COMPLIANT AS THE HIGHER SECTION | | | IS A PITCHED ROOF, BUT PLEASE ADDRESS ON | | | THE PLAN. | | | | | | THE RESPONSE LETTER STATES THAT THERE IS A | | | CLARIFICATION LETTER IN THE PACKAGE.PER DISCUSSION | | | WITH THE ENGINEER, THE LETTER WILL BE PROVIDED TO | | | PREVENT FIELD ISSUES (INSPECTIONS). | | | | | | 24.)ON THE YHS 50 STOREFRONT PRODUCT | | | APPROVAL, INDICATE WHICH PRODUCT YOU ARE | | | USING AS NOT ALL MEET WORST CASE FOR | | | WIND LOADS. | | | | | | THE YHS 50 STOREFRONT PRODUCT APPROVALS WERE NOT | | | RESUBMITTED.ANY PRODUCT APPROVALS NOT REVIEWED PRIOR | | | TO PERMIT ISSUANCE WILL REQUIRE SEPARATE PERMITS. | | | | | | 25-26.)ADDRESSED. | | | | | | 27.)ANY PRODUCT APPROVALS REQUIRED BY | | | FAC9B72 AND NOT SUBMITTED PRIOR TO | | | PERMIT ISSUANCE WILL REQUIRE SEPARATE | | | PERMITS; FOR INSTANCE, THE FLAT DECK | | | ROOF AND THE EXTERIOR METAL DOORS.FOR | | | THE FLAT DECK, INDICATE WHICH APPROVED | | | ASSEMBLY YOU WILL BE USING. | | | | | | 28.)ADDRESSED. | | | | | | NEW COMMENTS: | | | | | | 29.)SEE ELECTRIC COMMENTS REGARDING THE ENERGY CALCS. | | | ALSO PLEASE CLARIFY CONFLICT BETWEEN THE SQUARE FOOT | | | AREA ON THE PLAN AND THE ENERGY CALC SQUARE FOOT AREA. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-05 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-04 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2006-10-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 | | | RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | | | | 1.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.)PRODUCT APPROVALS TO BE REVIEWED BY | | | DESIGNER OF RECORD, FBC*106.3.3. | | | | | | 3.)A PRELIMINARY SURVEY WAS SUBMITTED, | | | BUT APPEARS TO HAVE BEEN REPLACED BY A | | | FINAL SURVEY.REMOVE THE PRELIMINARY | | | FROM THE PACKAGE OR CLARIFY AS TO ITS | | | PURPOSE AS THE INFORMATION ON IT IS | | | INCOMPLETE. | | | | | | 4.)SHEET C7, PARKING IS TO COMPLY WITH | | | CITY OF WEST PALM BEACH STANDARD, SEE | | | ATTACHED. | | | | | | 5.)SEPARATE PERMIT REQUIRED FOR THE | | | DUMPSTER ENCLOSURE.PLEASE COMPLETE A | | | PERMIT APPLICATION; SEPARATE PLANS ARE | | | NOT REQUIRED. | | | | | | 6.)PROVIDE MAXIMUM SLOPES FOR THE | | | ACCESSIBLE ROUTE SHEET SP1 OR C5, | | | FBC11-4.1.2(1). | | | | | | 7.)CODE DATE, SHEET G0-00-001, INCLUDE | | | SPRINKLER INFORMATION (APPEARS TO BE | | | FULLY SPRINKLED), BUILDING AREA | | | (EXISTING, PROPOSED ADDITION, NEW | | | TOTAL). | | | | | | 8.)A0-00-601 STATES THAT THE BUILDING | | | IS 30FT FROM THE PROPERTY LINE, SP1 | | | SHOWS A DISTANCE OF 27.97 ON THE SOUTH | | | SIDE.IT APPEARS THAT NO FIRE | | | RESISTANCE IS REQUIRED PER FBC TABLE | | | 602, BUT PLEASE REVISE THE NOTE. | | | | | | 9.)SHOW SIDEWALK WIDTH AT ACCESSIBLE | | | PARKING SPACE ON SHEET A0-00-601, | | | FBC11-4.6.2(1).44IN MINIMUM REQUIRED. | | | A DETAIL IS SHOWN ELSEWHERE ON THE PLAN | | | BUT WHEN SCALED THE SIDEWALK APPEARS TO | | | BE 24IN. | | | | | | 10.)SHEET A0-00-601 REFERS TO | | | ASCE7-98, CORRECT REFERENCE IS 7-02, | | | FBC35. | | | | | | 11.)SEE FBC313, FBC406.1.SHOW | | | OCCUPANCY CLASSIFICATION FOR THE GARAGE, | | | TOTAL SF FOR GARAGE AREA.IF OCCUPANCY | | | SEPARATION IS USED, IT MUST BE IN | | | COMPLIANCE WITH FBC TABLE 302.3.2, | | | FBC406.2.7, PENETRATIONS IN COMPLIANCE | | | WITH FBC712 (M1-01-101).REVISE | | | BUILDING ALLOWABLE AREA CALCULATIONS, | | | FBC 5. | | | | | | 12.)SEE FBC1013.2.THE LIFE SAFETY | | | PLAN A0-00-601 SHOWS THE STAIR 2 | | | TERMINATING IN THE COVERED PARKING AREA. | | | NO DOORS SHOWN FROM THE GARAGE TO THE | | | OUTSIDE, GATE DOES NOT COMPLY WITH | | | FBC1008.1.2 EXCEPTIONS.THIS MAY SERVE | | | AS EGRESS FROM THE PARKING GARAGE, SEE | | | EXCEPTION 1, BUT NOT FROM THE BUSINESS | | | AREA.ALSO SEE FBC1013.2 REGARDING | | | EGRESS THROUGH INTERVENING SPACES. | | | | | | 13.)DETAIL 4-A2-02-001, THE SINK IS TO | | | BE MOUNTED NO HIGHER THAN 34IN | | | FBC11-4.24.2.PROVIDE A DETAIL FOR THE | | | SINK, SEE FBC11-4.24.NOTE THAT CABINET | | | DOORS NOT PERMITTED AS IT PREVENTS THE | | | KNEE CLEARANCE REQUIRED BY FBC11-4.24.3. | | | | | | 14.)DETAILS 21 AND 13, SHEET | | | A7-02-101, CABINET DOORS NOT PERMITTED | | | AS IT PREVENTS THE SINK KNEE CLEARANCE | | | REQUIRED BY FBC11-4.24.3 | | | | | | 15.)THE BUILDING APPEARS TO BE THREE | | | STORIES IN THE STAIRWAY.SEE SHEET | | | A6-00-101.TWO STORY BUILDING DECLARED | | | ON A0-00-601. | | | | | | 16.)DECLARE AN OCCUPANT LOAD FOR THE | | | ROOF TERRACE AND ROOF GARDEN AREAS. | | | | | | 17.)SECTION 2-A6-00-101, THE STAIR | | | RAIL IS TO EITHER BE ROUNDED OR RETURN | | | TO THE FLOOR, WALL, OR POST.A STRAIGHT | | | EXTENSION IS SHOWN. | | | | | | 18.)SECTION 2-A6-00-101, THE AREA | | | UNDER THE STAIR LACKS THE HEADROOM | | | REQUIRED BY FBC11-4.4.2, BARRIER | | | REQUIRED. | | | | | | 19.)A9-01-201 INDICATES THAT BATHROOM | | | WALL FINISHES ARE TO BE DETERMINED.SEE | | | FBC1210.2, HARD NONABSORBENT SURFACE | | | REQUIRED. | | | | | | 20.)NO PENETRATIONS ALLOWED IN THE | | | EXIT ENCLOSURE (STAIRS), FBC1-019.1.2, | | | SEE MECHANICAL SHEETS. | | | | | | 21.)SPECIFY FIRE RATING FOR FIRE RATED | | | DOORS, FC TABLE 715.3, SHEET A8-00-101. | | | | | | | | | 22.)SPECIFY ANCHORING FOR THE | | | GENERATOR, FBC1606.1.3, UNLESS THIS WILL | | | BE ON A SEPARATE PERMIT. | | | | | | 23.)STRUCTURALS STATE THAT MRH IS | | | 24FT.NOTE THAT THE STAIR ROOF IS AT | | | APPROXIMATELY 37FT.DESIGN PRESSURES | | | APPEAR COMPLIANT AS THE HIGHER SECTION | | | IS A PITCHED ROOF, BUT PLEASE ADDRESS ON | | | THE PLAN. | | | | | | 24.)ON THE YHS 50 STOREFRONT PRODUCT | | | APPROVAL, INDICATE WHICH PRODUCT YOU ARE | | | USING AS NOT ALL MEET WORST CASE FOR | | | WIND LOADS. | | | | | | 25.)FOR THE MULLION PRODUCT APPROVAL, | | | INDICATE WHICH PRODUCT YOU ARE | | | INSTALLING. | | | | | | 26.)FOR THE PICTURE WINDOW PRODUCT | | | APPROVAL, INDICATE WHICH PRODUCT YOU ARE | | | INSTALLING. | | | | | | 27.)ANY PRODUCT APPROVALS REQUIRED BY | | | FAC9B72 AND NOT SUBMITTED PRIOR TO | | | PERMIT ISSUANCE WILL REQUIRE SEPARATE | | | PERMITS; FOR INSTANCE, THE FLAT DECK | | | ROOF AND THE EXTERIOR METAL DOORS.FOR | | | THE FLAT DECK, INDICATE WHICH APPROVED | | | ASSEMBLY YOU WILL BE USING. | | | | | | 28.)SHOW COMPLIANCE WITH FBC1014.2.1, | | | EXCEPTION 2, EXITS TO BE LOCATED MORE | | | THAN 1/3 THE DIAGONAL APART. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-09-03 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-09-03 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2008-09-03 15:22:05 | AS-BUILTS WERE GIVEN BACK TO ROSE . ELECTRICAL REVIEW | | | IS NOT REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-30 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-30 |
Time |
09:35 |
Sent To |
PC |
|
| Notes |
| 2008-07-30 09:36:16 | ** DENIEDREVIEW ** | | | | | | | | | 1) NOTE:ELECTRICAL PERMIT IS CLOSED OUT AND ALREADY | | | HAS FINAL. NO PLAN REVIEW TO BE DONE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-16 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-16 |
Time |
13:36 |
Sent To |
M |
|
| Notes |
| 2008-06-16 13:36:32 | ENERGY CALCS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-29 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-29 |
Time |
12:57 |
Sent To |
PC |
|
| Notes |
| 2008-05-29 12:57:39 | ** DENIED/HOLD REVISIONS** | | | REVISED ENERGY CALCULATIONS AND PLANS SUBMITTED 5/15. | | | | | | 1) NOTE:PLEASE SEE THE INFORMATION ON THE | | | CERTIFICATION SHEETS FOR PREPARER OF ENERGY | | | CALCULATIONS AND OTHER DESIGNERS IS NOT COMPLETE. FOR | | | EXAMPLE: PLEASE SEE THE PERSON PREPARING DOCUMENTS FOR | | | THIS SCOPE OF WORK SHALL BE A LICENSED PE ALONG WITH | | | THE OTHER DESIGNERS LISTED ON SHEET. SOME OF THE | | | INDIVIDUALS LISTED DO CONTAIN LICENSE INFORMATION, SOME | | | DO NOT. | | | AN E-MAIL WAS SENT AS OF THIS REVIEW REQUESTING | | | INFORMATION FROM MR. CHRIS CONROY. | | | | | | 2) NOTE: PLEASE BE SURE TO SEE NOTES DATED AS OF THIS | | | DATE WHICH AFFECT ELECTRICAL REVISIONS. REVISED | | | ELECTRICAL PLANS WERE SUBMITTED WITH DOZENS OF HAND | | | DRAWN CHANGES TO PHOTO-COPIED ENGINEERED PLANS WHICH IS | | | NOT PERMITTED. | | | PLEASE BE SURE TO COORDINATE THIS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-29 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-29 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2008-05-29 12:51:12 | ** DENIEDREVIEW FOR REVISIONS** | | | | | | 1) NOTE:PLEASE SEE ARCHITECTURAL SHEETS, ELECTRICAL | | | SHEETS AND PLUMBING SHEETS SUBMITTED 5/20/08 ARE ALL | | | *PHOTO-COPIES OF SIGNED AND SEALED PLANS. THESE SHEETS | | | ALSO CONTAIN NUMEROUS ITEMS WHICH HAVE BEEN HAND DRAWN | | | ON SHEETS WHICH IS NOT PERMITTED. | | | PLEASE KNOW ALL LOW VOLTAGE SYSTEMS BEING ADDED MUST BE | | | REVISED BY THE BASE BUILDING ELECTRICAL ENGINEER OF | | | RECORD ALONG WITH PERMIT FOR SUCH WORK. | | | PLEASE SEE THAT ANY REVISED LIGHTING MODULES ETC WHICH | | | WERE ADDED TO PLANS MUST ALOS BE INCLUDED AND REVISED | | | IN THE BASE BUILDING PLANS. | | | FS481.221 AND 471.025 | | | FBC 106.3.5.1.2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2008-05-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-06 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-06 |
Time |
10:37 |
Sent To |
PC |
|
| Notes |
| 2008-05-06 10:38:12 | ** DENIED REVISIONS ** | | | | | | 1) NOTE: PLEASE SEE THE VERSION OF THE ENERGY | | | CALCULATIONS SHALL BE UNDER THE VERSION WHICH PERMIT | | | APPLICATION WAS MADE. PLEASE KNOW THE VERSION SUBMITTED | | | AS 2.5 WAS NOT ADOPTED UNTIL 12/8/06. PERMIT WAS | | | APPLIED FOR BEFORE THIS DATE. VERSION 2.11 WAS IN | | | AFFECT AT THE APPLICATION DATE. | | | 13-400.3.A (2005 REVISIONS TO THE 2004 FBC) | | | | | | 2) NOTE: PLEASE SEE THE PLANS DO NOT CORRELATE WITH THE | | | CALCULATIONS OR INPUT DATA REPORT. PLEASE SEE THE | | | FIXTURES ON PHOTO-METRICS DO NOT COORDINATE WITH THE | | | LIGHTING FIXTURES ON THE FIXTURE LEGEND. | | | PLEASE SEE | | | FOR EXAMPLE: | | | PLEASE SEE THE FIXTURES SL2 WHICH ARE ON FIXTURE LEGEND | | | ON E0-00-001 WHICH ARE NOT THE SAME AS SHEET | | | E1-01-301. | | | THESE SAME FIXTURES COULD NOT BE LOCATED FOR THE TOTAL, | | | WATTAGE ETC IN THE IDR. THE IDR CONTAINS FIXTURES FOR | | | EXTERIOR BUT NOT ALL. | | | PLEASE SEE THE IDR ALSO CONTAINS A *NON-A/C* ZONE | | | HOWEVER THESE SL2 FIXTURES ARE NOT IN THIS ZONE. | | | THE GARAGE ALONE SHOWS A MINIMUM OF 8-SL2 FIXTURES. | | | THERE ARE NO SL2 FIXTURES ON IDR. SL2 FIXTURES INDICATE | | | 4-42W COMPACT BULBS. PLEASE GOT THROUGH ALL AND | | | COORDINATE. | | | THESE WERE SPECIFICALLY NOTED ON THE PREVIOUS REVIEW | | | HOWEVER THE SAME FIXTURES ARE THE SAME COMMENTS. ONE | | | COPY OF THE CALCULATIONS WILL BE RETAINED BY THIS | | | OFFICE. | | | **** IT IS IMPORTANT TO KNOW THIS IS NOT AN EXHAUSTED | | | LIST AS THERE ARE OTHER FIXTURES WHICH DO NOT | | | COORDINATE. THE EXAMPLES ARE GIVEN AS A BENEFIT ONLY. | | | | | | PLEASE SUBMIT COMPLETED REVISED LIGHTING PLANS FOR ALL | | | REVISED LIGHTING. THIS WOULD INCLUDE ALL OUTSIDE | | | LIGHTS, EVEN 2ND FLOOR ARE. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2008-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-09 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-09 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2008-02-11 08:39:39 | ** DENIED REVISIONS ** | | | | | | 1) NOTE: PLEASE SEE PROVISO NOTES FROM MAY 07 HAVE NOT | | | YET BEEN SUBMITTED FOR CORRECTIONS. PLEASE SEE NOTES | | | ATTACHED TO THIS REVIEW. | | | | | | 2) NOTE: PLEASE SEE THE REVISED ENERGY CALCULATIONS | | | HAVE ITEMS WHICH NEED TO BE ADDRESSED. IN THE FOLLOWING | | | NOTES THE INPUT DATA REPORT WILL BE NOTED AS IDR. | | | | | | A) ** PLEASE SEE THE SIGNATURE OF THE OWNER AGENT NEEDS | | | TO BE SIGNED ON CERTIFICATION SHEETS. 13-103.1.1.1 | | | | | | B) ** PLEASE SEE THE LIGHTING AS SHOWN ON PLANS NEEDS | | | TO COORDINATE WITH THE LIGHTING ON THE IDR. | | | PLEASE SEE THE EXTERIOR LIGHTING ON THE IDR DOES NOT | | | MATCH WITH THE FIXTURE LEGEND ON PLANS, THE NUMBER OF | | | FIXTURES OR THE WATTAGE OF FIXTURES. A FEW EXAMPLES | | | WILL BE NOTED BELOW. | | | PLEASE SEE FIXTURE SL3 WHICH IS 500WATTS ON IDR, IS | | | ONLY 250WATTS ON FIXTURE LEGEND. | | | PLEASE SEE THIS SAME SL3 FIXTURE ON THE IDR SHOWS ONLY | | | THREE FIXTURES YET THE PLANS SHOW AT LEAST SEVEN. | | | PLEASE SEE THE SL2 FIXTURES ON PLANS ARE NOT EVEN ON | | | THE IDR. | | | PLEASE SEE THE SL2 FIXTURE ALSO NEEDS TO SHOW WATTAGE | | | OF FIXTURE ON FIXTURE LEGEND. | | | PLEASE SEE THE CATEGORY FOR SL3 AND SL4 STATES | | | *LIGHTING THAT IS SPECIFICALLY DESIGNATED AS REQUIRED | | | BY A HEALTH, OR LIFE SAFETY STATUTE OR ORDINANCE*. | | | PLEASE KNOW THERE IS NO SPECIFIC STATUTE, ORDINANCE, OR | | | CODE WHICH THIS TYPE OF OUTSIDE LIGHTING IS REQUIRED. | | | THERE IS SOME LIGHTING THAT IS REQUIRED BY STATUTES, | | | HOWEVER THIS OCCUPANCY AND LOCATIONS DOES NOT FALL | | | UNDER THIS. | | | ** THIS WAS A FEW EXAMPLES, PLEASE BE SURE TO | | | COORDINATE OTHERS AS WELL. | | | | | | 3) NOTE: PLEASE SUBMIT REVISED PHOTO-METRICS FOR | | | REVISIONS IN THE LIGHTING PLANS. PLEASE KNOW THAT THE | | | REVISED OUTSIDE LIGHTS DO NOT COORDINATE WITH THE | | | LIGHTING FIXTURES AS SHOWN ON PHOTO-METRICS. NOT ALL | | | BUT SOME ARE IN NEED OF BEING REVISED. | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION/COORDINATION. | | | | | | PLEASE SUBMIT REVISED ITEMS. PLEASE BE SURE TO CALL IF | | | THERE ARE ANY QUESTIONS OR IF THE COMMENTS ARE NOT | | | UNDERSTOOD IN ANY FASHION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-21 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-21 |
Time |
07:46 |
Sent To |
PC |
|
| Notes |
| 2007-06-21 09:43:39 | REVISIONS ADDRESSING PREVIOUS *PROVISO* ARE OK. STAMPED | | | SHEETS. | | | | | | SHEETS SUBMITTED WITHOUT REVISIONS OR CHANGES ARE BEING | | | RETURNED AS THEY ARE THE SAME AS PLANS ALREADY ON | | | RECORD. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-15 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-15 |
Time |
11:38 |
Sent To |
B |
|
| Notes |
| 2007-05-15 16:39:48 | ** PROVISO/REVISIONS REQUIRED ** | | | | | | ** PLEASE SEE REFERENCES TO CHAPTER 1 OF THE FLORIDA | | | BUILDING CODE IS THE ADMINISTRATIVE SECTION AS ADOPTED | | | BY THE CITY OF WEST PALM BEACH. | | | | | | ** PLEASE SEE THE BELOW COMMENTS ARE BASED ON CHANGES | | | ON PLANS. THERE ARE ITEMS ON THE ELECTRICAL RISER | | | DIAGRAM/PANELS WHICH WERE CHANGED FROM PREVIOUS PLANS | | | AND NOT PART OF PREVIOUS REVIEWED PLANS. NEW COMMENTS | | | ARE NOW BASED ON THESE CHANGES. | | | | | | 1) NOTE:PLEASE SEE THE ELECTRICAL RISER. PLEASE | | | COORDINATE FEEDERS/CONDUCTORS WITH THAT OF THE FEEDER | | | LEGEND AND THE PANEL(S). | | | A) PLEASE SEE RISER SHOWS 250MCM FROM PANEL *H* TO | | | *MH*, HOWEVER PANEL *MH* INDICATES 500MCM. | | | ** THIS FEEDER WAS REVISED FROM PREVIOUS PLANS. | | | | | | B) PLEASE SEE THE FEEDERS FROM *QQ* TO *MQ* WHICH NOW | | | INDICATE 4/300, WHICH TRANSLATED TO THE FEEDER SCHEDULE | | | SHOULD BE 4-350MCM AND EQUIPMENT GROUND, HOWEVER THE | | | FEEDER LEGEND ONLY INDICATES 3-350MCM AND EQUIPMENT | | | GROUND WHICH IS MISSING ONE PHASE OR NEUTRAL CONDUCTOR. | | | | | | ( 4-WIRE COLUMN CONTAINS OTHERS NOTED AS 3-WIRE, | | | HOWEVER THESE DO NOT APPLY TO RISER) | | | **THIS FEEDER WAS REVISED FROM PREVIOUS PLANS. | | | | | | C) PLEASE SEE THE NEW METER CENTER ELEVATION WHICH DOES | | | NOT COORDINATE WITH THE RISER BELOW ELEVATION AS | | | SHOWN. | | | PLEASE SEE THE ELEVATION SHOWS 225AMP MAIN CIRCUIT | | | BREAKERS FOR MAIN FOR THE HOUSE AND AMERICAN LUNG | | | HOWEVER THE ELECTRICAL RISER SHOWS 250AMP MAIN CIRCUIT | | | BREAKERS WHICH DO NOT CORRELATE. | | | **THIS ELECTRICAL RISER AND METER CENTER ELEVATION WAS | | | REVISED FROM PREVIOUS PLANS. | | | | | | 2) NOTE: PLEASE SEE RISER, AS THE TAPPED CONDUCTORS ARE | | | NOT SHOWN FROM GUTTER TO EACH METER OR FIRST MEANS OF | | | DISCONNECT, THE RISER WAS REDLINED TO NOTE THAT *NO | | | EQUIPMENT GROUNDING CONDUCTOR* BEFORE THE FIRST MEANS | | | OF DISCONNECT. | | | | | | 3) NOTE: PLEASE COORDINATE THE SHEET DESIGNATION OF | | | E1-01-301 AS THE FIRST FLOOR IS CALLED LIGHT DENSITY | | | AND SECOND FLOOR IS PHOTO-METRICS. | | | | | | 4) NOTE:PLEASE KNOW THE ABOVE CORRECTIONS MUST BE | | | SUBMITTED FOR REVIEW BEFORE ANY ROUGH ELECTRICAL | | | INSPECTION IS CALLED IN OR 30DAYS WHICH EVER COMES | | | FIRST. THIS CONDITION OF ISSUANCE WILL PLACE PERMIT ON | | | HOLD WITHIN 30DAYS IF REVISIONS ARE NOT SUBMITTED. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-09 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-08 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2007-04-09 18:10:33 | | | | ** UNSAT3RD REVIEW ** | | | | | | 11) NOTE: PLEASE SEE THAT COMPLIANCE WITH THE ENERGY | | | CALCULATIONS HAS NOT BEEN MET. | | | ** PLEASE SEE THAT THIS IS THE FIRST TIME THAT ENERGY | | | CALCULATIONS ARE BEING SUBMITTED FOR REVIEW. PLEASE SEE | | | THERE ARE SEVERAL ITEMS ON CALCULATIONS WHICH DO NOT | | | CORRELATE WITH PLANS. | | | PLEASE SEE THE WATTAGES FOR MANY OF THE SAME FIXTURES | | | ON PLANS ARE BEING SHOWN ON ENERGY CALCULATIONS AS | | | DIFFERENT WATTAGES EVEN THOUGH IT'S THE SAME FIXTURE. | | | ONE FIXTURE IS SHOWN WITH AS MANY AS THREE DIFFERENT | | | FIGURES FOR WATTAGE. 26, 55, AND 62. | | | PLEASE CLARIFY MISSING AREAS ON PLANS, WHICH ARE NOT IN | | | CALCULATIONS. | | | PLEASE SEE SOME AREAS ON PLANS DO NOT CORRELATE WITH | | | THE SAME AMOUNT OF FIXTURES ON CALCULATIONS. PLEASE SEE | | | THE NUMBER OF LIGHT FIXTURES IN SOME ROOMS ON PLANS | | | SHOW FOR EXAMPLE THREE FIXTURES AND ENERGY CALCULATIONS | | | SHOW TWO OR TWO ON PLANS AND ONE IN CALCULATIONS ETC. | | | PLEASE SEE STORAGE ROOMS, STAIRS, SOME OFFICES WHICH | | | CONTAIN THE EXACT SAME FIXTURES, YET SHOWN WITH | | | DIFFERENT FIGURES ON CALCULATIONS. | | | PLEASE CLARIFY WATTAGE USE IN CALCULATIONS WITH THAT OF | | | THE FIXTURES. PLEASE SEE THE PLANS AND FIXTURE LEGEND | | | CONTAINS FIXTURES AT ONE LEVEL OF WATTAGE AND THE | | | ENERGY CALCULATIONS INDICATE A DIFFERENT WATTAGE? | | | PLEASE GO THROUGH ALL ENERGY CALCULATIONS AS THERE ARE | | | MANY OF THESE ITEMS WHICH CAN NOT BE LISTED ONE FOR | | | ONE. | | | | | | PLEASE SEE 2004 FBC CHAPTER 13, 13-415.1.AB.1.1, | | | 13-415.2 | | | | | | 2) NOTE: PLEASE SEE THE ELECTRICAL LIGHTING PLANSFOR | | | FIRST AND SECOND FLOORS AND LIGHTING POWER DENSITY | | | SHEETS DO NOT CORRELATE. | | | PLEASE SEE SOME OF THE ROOM LAYOUTS AND LIGHTING | | | LAYOUTS AND THE AMOUNT OF FIXTURES ON THESE SHEETS DO | | | NOT CORRELATE. | | | PLEASE SEE E1-01-101, E1-01-302, ETC. | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE SEE SOME SHEETS INDICATE THE ELECTRICAL | | | ROOM ALSO BEING PART OF THE WATER METER ROOM IN THE | | | SAME ROOM AND SOME SHEETS INDICATE THESE BEING IN TWO | | | SEPARATE ROOMS? | | | PLEASE SEE 110.26 AND ROOMS AND AREAS WHICH ARE | | | REQUIRED TO BE DEDICATED ELECTRICAL SPACE. | | | PLEASE COORDINATE SHEETS AND LAYOUTS FOR ROOMS/WALLS. | | | PLEASE SEE E1-01-101, 302, 201 ETC | | | | | | 4) NOTE: PLEASE SEE THE PHOTO-METRIC TABLES ON THE SITE | | | PLANS WHICH ARE NOT READABLE AT THIS TIME, PLEASE | | | ADJUST THE SCALE ON PLANS FOR THIS. | | | 106.1.2, 106.3.1 | | | | | | 5) NOTE:PLEASE SEE THE PANEL *A* IS BEING SHOWN WITH | | | FEED-THRU LUGS TO PANEL *MA* WHICH INDICATES 200AMP | | | OVER CURRENT PROTECTION ON 2/0 WHICH ARE ONLY RATED FOR | | | 175AMPS. | | | PLEASE SEE 310.16, 240.4. | | | PLEASE SEE THE RISER SEEMS TO INDICATE THE CORRECT SIZE | | | TO LEGEND ON PLANS. | | | | | | 6) NOTE: PLEASE SEE THAT LOAD CALCULATIONS ARE NOW | | | BEING SUBMITTED FOR REVIEW FOR THE FIRST TIME. THESE | | | COMPLETED CALCULATIONS WERE NOT SUBMITTED ON PREVIOUS | | | PLANS. THE GENERAL VA PER SQ FT FOR RECEPTACLES MAY | | | ONLY BE USED WHEN THE KNOWN NUMBER OF DEVICES IS NOT | | | KNOWN. PLEASE SEE THAT THE PLANS DO HOWEVER INDICATE | | | THE TOTAL NUMBER OF DEVICES THEREFORE THE MINIMUM | | | REQUIRED VA IS TO BE BASED ON THE AMOUNT OF RECEPTACLES | | | AT 180VA PER DEVICE. | | | PLEASE SEE 220.13 AND ADJUST CALCULATIONS. | | | | | | 7) NOTE: PLEASE SEE THE LOADS SHOWN ON THE PANEL | | | SCHEDULES FOR *Q, H AND A*ARE NOT THAT OF THE CONNECTED | | | LOAD BEING SHOWN IN THE LOAD CALCULATIONS ON SHEET | | | E0-00-01. | | | PLEASE SEE THE LOAD ON THE *A* PANEL SEEMS TO BE VERY | | | CLOSE TO LOAD PERMITTED ON THIS PANEL AND MAINS. PLEASE | | | SEE 90.8 AS THERE DOES NOT SEEM TO BE MUSH ROOM FOR | | | FUTURE LOADS OR CHANGES IN DESIGN. PLEASE REVIEW LOADS | | | AND BE SURE LOADS DO NOT EXCEED RATING OF SERVICE AND | | | CONSIDERATION IS TAKEN FOR ANY FUTURE LOADS. PLEASE | | | ALSO SEE THE LOAD CALCULATIONS FOR WHAT APPEARS TO BE | | | THE LOAD FOR THE ENTIRE SERVICE AS THESE ARE BEING | | | LABELED FOR THE *QUANTUM* SERVICE. | | | THIS SEEMS TO BE A MISPRINT FOR SERVICE. | | | PLEASE SEE NEC 220. | | | FBC 106.3.5.1.2 | | | | | | 8) NOTE: PLEASE SEE THE PANEL SCHEDULES WILL BE | | | REQUIRED TO BE SPECIFIC TO LIST ALL CIRCUITS TO ROOMS | | | AND AREAS IN WHICH THEY FEED. | | | PLEASE SEE THE USE OF *GENERAL LIGHTING OR GENERAL | | | RECEPTACLES* IS NOT ACCEPTABLE ANDWILL BE REQUIRED TO | | | LIST ROOMS OR AREAS FOR WHICH THEY FEED. THIS MAY BE | | | DONE BY OFFICE DESIGNATION BY NAME OR NUMERICAL | | | IDENTIFICATION. | | | A *PROVISO* (CONDITION OF ISSUANCE) MAY BE SET UP FOR | | | THIS ITEM OR THIS MAY BE ADDRESSED AT THIS TIME. PLEASE | | | SEE THE FOLLOWING TEXT WHICH IS TAKEN FROM THE CODE | | | COMMENTARY* | | | *PROVISO* (CONDITION OF ISSUANCE) MAY BE SET UP FOR | | | THIS ITEM. | | | | | | *CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* 408.4, | | | 310.16, 240.4 ETC | | | | | | 9) NOTE: PLEASE SEE THAT ONE SET OF ELECTRICAL PLANS | | | AND ENERGY CALCULATIONS ARE BEING RETAINED BY THIS | | | OFFICE AT THIS TIME. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-04-08 13:59:49 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-15 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-14 |
Time |
19:10 |
Sent To |
|
|
| Notes |
| 2007-01-15 14:25:18 | | | | | | | *** UNSAT 2ND REVIEW*** | | | | | | AMERICAN LUNG ASSOCIATION | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW STILL | | | NEED TO BE ADDRESSED ALONG WITH SOME NEW COMMENTS BASED | | | ON CHANGES MADE TO PLANS. | | | PLEASE KNOW THAT THERE NEW COMMENTS BASED ON PLANS AND | | | CHANGES MADE. | | | | | | ** PLEASE KNOW THAT BASED ON THE LAST MEETING HELD, THE | | | ARCHITECT WAS PRESENT HOWEVER NO CONTACT TO DATE HAS | | | BEEN MADE BY THE ENGINEERING DESIGNER(S) TO GO OVER | | | COMMENTS. | | | | | | ** PLEASE SEE THE COMMENTS BELOW ARE TAKEN DIRECTLY | | | FROM PREVIOUS REVIEW IN THE SAME NUMERICAL ORDER. THEY | | | WILL CONTAIN A NO, OK, OR NO/OK. | | | A) NO WILL BE FOLLOWED BY FURTHER EXPLANATION OF THE | | | PREVIOUS COMMENT. | | | B) OK, MAY REFERENCE TO ANY NEW NOTES, HOWEVER WILL | | | HAVE PREVIOUS NOTE REMOVED. | | | C) NO/OK, WILL BE FOLLOWED BY FURTHER EXPLANATION AS | | | PART OF THE COMMENT MAY NOT HAVE BEEN ADDRESSED FULLY | | | AND PART OF THE PREVIOUS COMMENT MAY BE OK. | | | D) OK/N/A, AS THE PREVIOUS NOTE DOES NOT APPLY ANY | | | FURTHER AS PLANS HAVE DELETED OR CHANGED. | | | | | | ** ANY NEW NOTES WILL BE AT THE BOTTOM AND IDENTIFIED | | | AS *** NEW NOTES ***. | | | | | | | | | | | | | | | 1) NOTE: NO/OK. PLEASE SEE THE ENGINEERING BUSINESS | | | NUMBER WAS VERIFIED WITH THE STATE, HOWEVER PLEASE SEE | | | THE ADDRESS FOR FIRM ON THE STATE'S WEBSITE AND PLANS | | | DIFFER. A FAR AS WE HAVE BEEN INFORMED FROM THE STATE, | | | THIS INFORMATION IS REQUIRED TO MATCH. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING REQUIRED LICENSE INFORMATION ON | | | TITLE BLOCKS. | | | PLEASE SEE FAC 61G15-23.002 AND FS | | | 471.023. | | | PLEASE KNOW PER THE FLORIDA STATUES AS NOTED ABOVE AND | | | PER THE FLORIDA BOARD OF PROFESSIONAL ENGINEERS, ANY | | | FIRM PRACTICING ENGINEERING AND OFFERING ENGINEERING | | | SERVICES MUST ALSO OBTAIN A CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR THE ENGINEERING PART OF THE | | | BUSINESS. | | | PLEASE SEE THE FIRM NUMBER AS SHOWN IS ONLY LICENSED | | | FOR THE ARCHITECTURAL FIRM. | | | PLEASE ALSO SEE ADDRESS ON TITLE BLOCK DO NOT CORRELATE | | | WITH THE ADDRESS AS LISTED ON THE STATE'S DEPARTMENT OF | | | BUSINESS AND PROFESSIONAL REGULATION. | | | PLEASE SEE THE ATTACHED PRINT OUT ATTACHED TO | | | ELECTRICAL NOTES. | | | ** THIS IS REQUIRED FOR ALL SHEETS AND FOR ALL TRADES | | | WHETHER OR NOT COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 2) NOTE: OK/NO, PLEASE SEE THIS WAS DONE HOWEVER THIS | | | INFORMATION WAS HAND WRITTEN ON SHEETS WHICH IS OK. THE | | | COMMENT WILL REMAIN AS NEW SHEETS WILL ALSO BE REQUIRED | | | TO CONTAIN THIS INFORMATION. THIS IS SOMETHING THAT | | | SHOULD BE ADDED INTO THE FIRMS CADD OR COMPUTER SYSTEMS | | | SO THAT THIS INFORMATION DOES NOT HAVE TO BE | | | HANDWRITTEN ON ALL SHEETS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING THE PRINTED NAME AND LICENSE NUMBER | | | FOR THE ENGINEER OF RECORD ON SAID TITLE BLOCKS AS | | | REQUIRED UNDER FAC 61G15-23.002 | | | | | | 3) NOTE: OK. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE: OK, N/A | | | | | | 6) NOTE: OK, AS THE GEN HAS BEEN REMOVED AND NOTES | | | BEING DONE AS FUTURE, HOWEVER PLEASE SEE THESE SECTIONS | | | AND PREVIOUS NOTES ARE BEING LEFT FOR INFORMATIONAL | | | REASONS FOR THE PANEL E WHICH IS BEING SHOWN AS FUTURE | | | WHICH DOES NOT SEEM TO MEET THESE SECTIONS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 225.31-225.39 FOR MISSING REQUIRED MEANS OF | | | DISCONNECT FOR THE FEEDERS FROM THE GENERATOR UNIT. | | | PLEASE SEE GROUPING ETC AS REQUIRED. | | | | | | | | | 7) NOTE: OK, HOWEVER SEE NEW NOTES WITH RESPECT TO GAP, | | | FACP AND FAAP. | | | | | | 8) NOTE: OK, N/A. SEE NEW NOTES HOWEVER FOR PANEL H. | | | | | | | | | 9) NOTE: OK. | | | | | | 10) NOTE: OK, N/A. | | | | | | 11) NOTE: OK, N/A. | | | | | | 12) NOTE: OK/NO, PLEASE SEE THESE ITEMS WERE ADDED, | | | HOWEVER PLEASE SEE MISSING CIRCUITING FOR THE ROOF TOP | | | GFI'S. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING DISCONNECTS FOR RTU'S WHICH COULD | | | NOT BE LOCATED ON PLANS. CAN BE TYPICAL IF THE SAME. | | | 440.11 | | | PLEASE ALSO SEE MISSING ROOF TOP GFI'S WHICH COULD NOT | | | BE LOCATED ON PLANS FOR ROOF. | | | 230.63, 210.8 | | | | | | 13) NOTE: NO, PLEASE SEE PLANS AS THE INTENTION SEEMS | | | TO HAVE BEEN MADE, BUT PLEASE SEE THAT THERE ARE LINES | | | FOR CIRCUITING WHICH STILL PLACES THE LIGHTING ON WITH | | | OTHER HOUSE CIRCUITS AND OTHER AREAS WHICH IS NOT | | | PERMITTED. PLEASE SEE SECTIONS AS NOTED REQUIRE | | | DEDICATED CIRCUITS WHICH MAY NOT FEED OTHER AREAS. | | | PLEASE SEE NOTE FOR CONTROL OF PIT LTS. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE MISSING THE REQUIRED DEDICATED CIRCUITS FOR | | | THE ELEVATOR MACHINE ROOM. | | | 620.23, 620.24 | | | | | | 14) NOTE:OK, HOWEVER SEE NEW NOTES FOR EMERGENCY | | | LIGHTING. | | | | | | 15) NOTE:NO, PLEASE SEE ALL DEVICES AS NOTED AND | | | SHOWN ON PLANS SHALL INDICATE ALL OF THE MAXIMUM TIMES. | | | ONLY ONE SYMBOL ON LEGEND CONTAINS THE INFORMATION AS | | | NEEDED. | | | PLEASE SEE ELEVATOR PIT LIGHTS WHICH APPEAR TO BE | | | MISSING CONTROL(S). | | | PLEASE CALL F THERE ARE ANY QUESTIONS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SPECIFY THE MAX OVER RIDE TIMES FOR THE OCCUPANT | | | SENSORS. | | | 30MIN MAX FOR SENSORS AND 4HRS MAX FOR TIMER TYPE OVER | | | RIDES. | | | PLEASE ALSO SEE SEPARATE SPACES/ROOMS WHICH SEEM TO BE | | | MISSING OVER RIDE CONTROLS. | | | PLEASE SEE FBC 13-415.1.ABC.1.1, .1.2, | | | .1.3 | | | | | | 16) NOTE:NO, PLEASE SEE THAT IT APPEARS BASED ON THE | | | RESPONSE FROM THE DESIGN TEAM THAT THIS COMMENT WAS NOT | | | UNDERSTOOD. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED SHOWING | | | METHOD A, INDICATES ALL LIGHTING BEING CONTROLLED AS | | | "MANUAL ON/OFF". THIS IS NOT POSSIBLE IF THERE ARE | | | AUTOMATED CONTROL LIGHTING SYSTEMS AND AUTOMATED | | | DEVICES/OCCUPANCY SENSORS ETC. | | | 13-415.1.ABC.1.1, .1.2, AND .1.3. 13-415.2. ETC. | | | | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE VERIFY HOW THE ENERGY CALCULATIONS SUBMITTED ALL | | | MENTIONS AND CONTAIN "MANUAL ON/OFF" CONTROLS FOR | | | LIGHTING?? | | | PLEASE SEE METHODS REQUIRED PER 13-415.1.AB.1. | | | | | | 17) NOTE:NO, PLEASE SEE BASED ON THE RESPONSE IT | | | MENTIONS TO SEE LIGHTING PHOTO-METRICS?? PLEASE KNOW | | | THAT PHOTO-METRICS AND LIGHTING POWER DENSITIES AND | | | PERFORMANCE CALCULATIONS A RE COMPLETELY DIFFERENT | | | ITEMS. | | | PLEASE SUBMIT PER SECTIONS GIVEN IN PREVIOUS REVIEW | | | NOTE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SUBMIT LIGHTING POWER DENSITY CALCULATIONS AS | | | REQUIRED. 13-415.1.AB.1,13 ,415.2.ABC.1 AND TABLES | | | 415.2.C.1 AND 415.2.B.1 (WHERE APPLICABLE) | | | | | | 18) NOTE: OK. | | | | | | 20) NOTE: OK, HOWEVER THIS NOTE WILL REMAIN AS BASED ON | | | THE SIZE OF THE SERVICE ENTRANCE CONDUCTORS, THE LOAD | | | CALCULATIONS SUBMITTED THIS MAY BE CHANGED AND/OR | | | INCREASED. SEE COMMENTS AS THIS PREVIOUS NOTE WILL | | | REMAIN AT THIS TIME. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 250.66 FOR MIN SIZING OF THE GEC. APPEARS | | | THIS SHOULD BE 2/0 MIN. | | | | | | 21) NOTE: NO, PLEASE SEE AS NOTED ABOVE THIS STILL | | | SEEMS TO BE IN QUESTION. PLEASE SEE SOME COMMON AREAS | | | WHICH ARE NOT FED FROM HOUSE PANELS, PLEASE SEE OTHER | | | AREAS LIKE THE ROOF TOP WHICH IS BEING FED FROM HOUSE | | | PANEL AND QQ PANELS FOR STAIRS. PLEASE SEE NOTES FOR | | | ELEVATOR ROOMS WHICH ARE BEING FED FROM HOUSE AND | | | TENANT PANELS. | | | THIS SCENARIO ON PLANS AS SHOWN IS NOT CLEAR. PLEASE | | | SEE THERE SEEMS TO BE AN ELECTRICAL ROOM ON FIRST FLOOR | | | WHICH REVIEW OF 240.24 SHOULD BE NOTED AND ADJUST PLANS | | | AS NEEDED. | | | PLEASE MAKE OTHER ADJUSTMENTS AS ROOF TOP ACCESS SEEMS | | | TO BE ONLY ACCESSIBLE THROUGH WHAT IT BEING SHOWN AS | | | STAIRWAYS FOR THE 2ND FLR TENANT ONLY. IF THESE | | | STAIRWAYS OR A STAIRWAY IS BEING USED FOR COMMON USE, | | | THEN THE ONE OR MORE BEING USED SHALL BE CIRCUITED FORM | | | THE HOUSE COMMON AREA PANEL/EQUIPMENT. | | | PLEASE ALSO SEE BOLLARDS BEING SHOWN ON ROOF?, AND | | | BEING SHOWN FROM HOUSE WHICH IS OK, HOWEVER NOT CLEAR | | | WHY THERE ARE BOLLARD TYPE FIXTURES ON ROOF? PLEASE | | | KNOW THAT AS PLANS ARE NOT CLEAR AT THIS TIME. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CLARIFY THE SEPARATION OF TENANTS. PLEASE SEE | | | PLANS AS SHOWN HAS CIRCUITING FROM EACH TENANT SERVICE | | | CROSSING OVER INTO OTHER TENANT'S AREAS AND ROOMS. IF | | | THE BUILDINGS GOING TO HAVE "HOUSE" POWER THESE MAY NOT | | | FEED INTO TENANT SPACES. PLEASE ALSO SEE | | | CIRCUITS FOR UPPER TENANT MAY NOT FEED AREAS IN LOWER | | | TENANTS. PLEASE SEE PROPER TENANT SEPARATION AND | | | CROSSING OVER OF CIRCUITS AND COMMON AREAS. PLEASE | | | ADJUST CIRCUITING ON PLANS. | | | PLEASE SEE "HOUSE" PANELS LOCATED ON FIRST FLR TENANTS | | | SPACE? | | | THIS IS UNCLEAR WHAT IS BEING PROPOSED IN THIS DESIGN | | | | | | 22) NOTE: NO, PLEASE SEE NEW COMMENTS AS THE RISER HAS | | | COMPLETELY CHANGED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE AS KNOW "SCHEDULE WAS SUBMITTED FOR THE | | | 800A BUS/METER CENTER, PLEASE INDICATE THE CONDUCTORS | | | FROM THE MAIN BUS TO EACH OF THE ATS UNITS. | | | 215.5, 240.4,310.16 | | | | | | 23) NOTE: OK, HOWEVER SEE NEW NOTES. | | | | | | 24) NOTE: OK/NO, CIRCUITS ARE BEING SHOWN, HOWEVER | | | COMING FROM HOUSE PANEL? PLEASE SEE 600.5 AND THE | | | REQUIRED DEDICATED CIRCUITS. THIS CIRCUIT AS SHOWN ON | | | PLANS COMES NOT ONLY FROM THE HOUSE PANEL; IT IS ALSO | | | SHOWN FEEDING OTHER AREAS OF LIGHTING. PLEASE SEE 600.5 | | | REFERENCES TO 220.3(B)6 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE VERIFY NEW OR EXISTING REQUIRED SIGN CIRCUIT PER | | | 600.5 | | | | | | 25) NOTE: NO, PLEASE SEE LOAD CALCULATIONS ARE NOT | | | COMPLETE PER NEC AND CODE SECTIONS GIVEN. | | | PLEASE ALSO SEE NEW NOTES BASED ON THE LOADS ALREADY | | | SHOWN WHICH EXCEED THE RATING OF THE SERVICE ENTRANCE | | | CONDUCTORS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE VERIFY AND SHOW LOAD CALCULATIONS FOR SERVICE | | | AND GENERATOR. | | | PLEASE SEE 220.3,220.10,220.11,220.13, ETC | | | PLEASE SHOW ALL CONTINUOUS LOADS AT 125%.215.3,230.42 | | | | | | 26) NOTE: OK,N/A. | | | | | | 27) NOTE: OK, N/A. | | | | | | 28) NOTE: NO, SEE NEW NOTES FROM THIS REVIEWER. | | | | | | PLEASE SEE POSSIBLE FIRE AND BUILDING REVIEW COMMENTS | | | AS IT DID NOT SEEM PLANS WERE SUBMITTED FOR ANY | | | BUILDING FIRE ALARM SYSTEM? | | | | | | **** NEW NOTES ****** | | | | | | | | | 29) NOTE: PLEASE SEE PANELS MH, MA, H, MQ ETC ALL LIST | | | FEEDS TO AUTOMATIC TRANSFER SWITCHES WHICH ARE NOT ON | | | RISER. THESE ARE NOT THE ATS DEVICES WHICH ARE SHOWN ON | | | RISER WHICH ARE NOTED AS FUTURE ON THE LINE SIDE OF | | | THESE PANELS. | | | PLEASE ALSO SEE ONE IS STILL BEING SHOWN AS LS /ATS FOR | | | LIFE SAFETY. PLEASE SEE IF THERE ARE LEGALLY REQUIRED | | | SYSTEMS OR LIFE SAFETY SYSTEMS, PLEASE REVISE PLANS. | | | PLEASE CLARIFY ALL OF THESE. REVIEW FOR ANY CODE | | | COMPLIANCE CAN NOT BE DONE AT THIS TIME AS PLANS ARE | | | CONFUSING AND ARE NOT CLEAR OF INTENTIONS, CODES AND | | | DESIGNS AS SHOWN. | | | PLEASE SUBMIT ALL MANUFACTURE'S SPEC/CUT SHEETS FOR ANY | | | PROPOSED SWITCHES TO BE INSTALLED AT THIS TIME. 110.3, | | | 90.7. | | | FBC 106.1.2, 106.3.5.1.2 ADMIN SECTION FOR ADDITIONAL | | | INFORMATION. | | | | | | 30) NOTE: PLEASE SEE THAT THE MEN'S AND WOMEN'S | | | BATHROOM WHICH ARE NOT SINGLE OCCUPANT OR SINGLE POINT | | | OF USE SHALL CONTAIN A BATTERY BACK UP LIGHT FIXTURE OF | | | SOME KIND. | | | PLEASE ALSO SEE UPPER STAIRS WHICH DO NOT INDICATE | | | BATTERY BACK UP FIXTURES. | | | PLEASE SEE PARKING GARAGE AREA FOR EGRESS TO THE PUBLIC | | | RIGHT OF WAY. | | | PLEASE SEE LS 101 7.8.1.3, AND 7.9.2.2. | | | PLEASE KNOW THE LIGHTING LEVELS ON STAIRS SHALL MEET | | | 10FT UNDER NORMAL AND 1FT CANDLED UNDER EM. | | | | | | 31) NOTE: PLEASE SEE THAT THESE PLANS SHALL CONTAIN A | | | BASE LAYOUT FOR ALL FIRE ALARM DEVICES TO REVIEW FOR | | | ADA COMPLIANCE. PLEASE SEE THE NOTE BEING PLACED ON THE | | | PLANS CAN NOT BE ACCEPTED. PLEASE KNOW THAT EVEN THOUGH | | | THE FIRE ALARM AND ANY FIRE SPRINKLER WILL BE REQUIRED | | | UNDER A SEPARATE PERMIT THESE BASE SYSTEMS ARE STILL | | | REQUIRED ON BASE BUILDING PLANS. | | | THIS WAS NOT A COMMENT ON THIS REVIEWER'S PREVIOUS | | | REVIEW; HOWEVER IT HAS NOW BECOME PART OF THE | | | ELECTRICAL REVIEW SINCE THESE PLANS WERE PREVIOUSLY | | | REVIEWED. PLEASE SEE COMPLIANCE FOR MINIMUM STROBE AND | | | SOUNDING DEVICE LEVELS SHALL BE STATED AND LOCATIONS | | | SHOWN. | | | PLEASE SEE 11-4.28.1, .2, AND.3(4). | | | FBC ADMIN SECTION 106.3.5.1.2 | | | | | | 32) NOTE: PLEASE CLARIFY PANELS H, A AND Q AS BEING | | | NOTED AS SERVICE ENTRANCE RATED. HOW IS THIS POSSIBLE | | | WHEN THESE ARE ALL BEING SHOWN AS MLO? | | | PLEASE ALSO EXPLAIN. | | | 106.1.2, 106.3.5.1.2, NEC 230.70, 110.3, 90.7 | | | | | | 33) NOTE: PLEASE SUBMIT MANUFACTURE'S SPEC/CUT SHEETS | | | ON THE PROPOSED SERVICE AS SHOWN ON RISER. THIS 800A | | | RATED BUS WHICH SHOWS NO MAIN, YET SHOWS SEPARATE | | | METERS AND MAINS FOR EACH TENANT AND HOUSE IS NOT | | | CLEAR. | | | IT MAY SEEM THAT THIS EQUIPMENT MAY BE REQUIRED TO | | | CONTAIN A MAIN? (IF APPLICABLE) | | | PLEASE SUBMIT MORE INFORMATION. FBC 106.1.2, | | | 106.3.5.1.2 | | | NEC 110.3, 90.7, 230.70, ETC | | | | | | 34) NOTE: PLEASE SEE BASED ON THE LOAD CALCULATIONS | | | SUBMITTED AND NOTED ABOVE IN NOTE #25, THE SEC'S ARE | | | NOT LARGE ENOUGH FOR THE LOADS AS SHOWN. PLEASE ALSO | | | KNOW BASED ON THESE LOADS SHOWN AND SOME LOADS WHICH | | | ARE REQUIRED WHICH HAVE NOT YET BEEN ADDED OR SHOWN THE | | | SIZING OF THESE CAN NOT BE VERIFIED FOR CODE COMPLIANCE | | | AT THIS TIME. | | | PLEASE ALSO SEE NOTE ABOVE AS IF THE EQUIPMENT CHANGES | | | SOME OTHER CODE SECTIONS MAY ALSO APPLY FOR DEVICES | | | RATED OVER 800AMPS. | | | PLEASE SEE 240.4, 310.16, 230.70, 230.76, 230.79, | | | 230.90, 230.91 ETC | | | | | | 35) NOTE: PLEASE SUBMIT WIND LOADS FOR NEW SITE | | | LIGHTING POLES AS SHOWN. THESE SHALL INDICATE THE | | | MINIMUM LEVELS PER FBC 140MPH 3-SEC GUST (120 | | | SUSTAINED) AND INDICATE THE EPA OF FIXTURES FOR THE | | | POLE BEING STATED. | | | PLEASE KNOW THIS WILL BE REVIEWED FURTHER BY THE | | | BUILDING REVIEWER. | | | | | | 36) NOTE: PLEASE KNOW CONTACT WITH THE FIRE MARSHAL'S | | | OFFICE SHOULD BE MADE FOR COORDINATION OF THE LOCATIONS | | | OF THE FACP, GAP(FUTURE) AND FAAP. | | | | | | 37) NOTE: PLEASE KNOW THIS IS BEING NOTED ONLY AS PANEL | | | E IS NOT UNDER THIS PERMIT. THE BREAKER IS BEING SHOWN | | | FOR ATS-LS.? | | | THIS IS ONLY BEING NOTED. | | | | | | 38) NOTE: PLEASE SEE ATTACHED REFERENCE TO FS | | | 553.80(2)(B) WITH RESPECT TO DESIGN PROFESSIONALS AND | | | REPEAT COMMENTS FOR CODE COMPLIANCE. THIS IS ONLY A | | | NOTICE GIVEN AT THIS TIME. | | | | | | ** PLEASE KNOW AS THERE MAY BE COMMENTS ON THE NEXT | | | REVIEW BASED ON INFORMATION NOT SHOWN OR CHANGES WHICH | | | WILL BE TAKING PLACE ON PLANS. | | | | | | ** PLEASE BE AWARE OF ANY COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT THE | | | ELECTRICAL PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-01-15 11:23:55 | 2007-01-15 11:23:55 | | | REVIEW IN PROGRESS | | 2007-01-14 19:10:49 | PLANS REMOVED FROM INCOMING TABLE. IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-10 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-10 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2006-09-10 00:00:00 | *** UNSAT *** | | | | | | AMERICAN LUNG ASSC | | | | | | 1) NOTE: PLEASE SEE MISSING REQUIRED | | | LICENSE INFORMATION ON TITLE BLOCKS. | | | PLEASE SEE FAC 61G15-23.002 AND FS | | | 471.023. | | | PLEASE KNOW PER THE FLORIDA STATUES AS | | | NOTED ABOVE AND PER THE FLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS, ANY FIRM | | | PRACTICING ENGINEERING AND OFFERING | | | ENGINEERING SERVICES MUST ALSO OBTAIN A CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR | | | THE ENGINEERING PART OF THE BUSINESS. | | | PLEASE SEE THE FIRM NUMBER AS SHOWN IS | | | ONLY LICENSED FOR THE ARCHITECTURAL | | | FIRM. | | | PLEASE ALSO SEE ADDRESS ON TITLE BLOCK | | | DO NOT CORRELATE WITH THE ADDRESS AS | | | LISTED ON THE STATE'S DEPARTMENT OF | | | BUSINESS AND PROFESSIONAL REGULATION. | | | PLEASE SEE THE ATTACHED PRINT OUT | | | ATTACHED TO ELECTRICAL NOTES. | | | ** THIS IS REQUIRED FOR ALL SHEETS AND | | | FOR ALL TRADES WHETHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | 2) NOTE: PLEASE SEE MISSING THE PRINTED | | | NAME AND LICENSE NUMBER FOR THE ENGINEER | | | OF RECORDON SAID TITLE BLOCKS AS | | | REQUIRED UNDER FAC 61G15-23.002 | | | | | | 3) NOTE: PLEASE SEE A LETTER WAS | | | ATTACHED FROM THE ENGINEER OF RECORD FOR VERIFICATION | | | OF LEGAL SIGNATURE. PLEASE | | | KNOW THE WORDING OF LETTER IS FINE, | | | HOWEVER LETTER MUST BE ORIGINAL. | | | (PHOTO-COPY SUBMITTED). MUST ALSO BE | | | SIGNED, DATED AND SEALED BY SAID | | | ENGINEER. | | | PLEASE ALSO SEE THE STATUES IN WHICH | | | STATE THE DOCUMENT IS BEING NOTARIZED, | | | IF IN FLORIDA PLEASE SEE FS 117.05 AS IN | | | THE STATE OF FLORIDA A STAMP AND | | | SIGNATURE OF NOTARY IS NOT ALL THAT IS | | | REQUIRED FOR A LEGAL DOCUMENT. | | | | | | 4) NOTE: PLEASE SEE SURVEY SUBMITTED IN | | | INDEED A PHOTO-COPY OF THE SIGNATURE | | | WITH A RAISED SEAL OVER PHOTO-COPIED | | | SIGNATURE WHICH IS NOT PERMITTED UNDER | | | FAC 61G17, FS 472.025 | | | PLEASE ALSO SEE THAT THE RAISED SEAL | | | MUST BE CLEAR AND VISIBLE WITH ALL | | | INFORMATION ON SAID SEAL. (NOT VISIBLE AT | | | THIS TIME). | | | PLEASE CORRELATE THE SURVEY WITH THE | | | ELECTRICAL PLANS, AS THE E-SHEETS | | | INDICATE ANEW GENERATOR.(PLEASE SEE | | | ZONING COMMENTS FOR THIS. | | | | | | 5) NOTE: PLEASE SUBMIT ALL MANUFACTURES | | | SPECS/CUT SHEETS FOR THE NEW GENERATOR, | | | NEW SUB-BASE FUEL TANK AND EACH OF THE | | | PROPOSED ATS SWITCHES. | | | PLEASE SEE THAT ALL SPEC SHEETS FOR THE | | | ATS UNITS CONTAINS A LISTING FROM A | | | (NRTL). NATIONALLY RECOGNIZED TESTING | | | LABORATORY. | | | PLEASE ALSO BE SURE ALL AIC RATING FOR | | | ALL ATS UNITS AND MAINS ARE INDICATED ON | | | PLANS/SPECS.700.5, 701.6,702.5 NFPA-110 | | | 6.5 | | | 110.3,90.7 | | | FBC 106.1.2 ADMIN SECT. | | | | | | 6) NOTE: PLEASE SEE 225.31-225.39 FOR | | | MISSING REQUIRED MEANS OF DISCONNECT FOR | | | THE FEEDERS FROM THE GENERATOR UNIT. | | | PLEASE SEE GROUPING ETC AS REQUIRED. | | | | | | | | | 7) NOTE: PLEASE SEE A NOTE FOR SIGNAGE | | | IS REQUIRED INCLUDING SIGNAL DEVICES. | | | 700.7,700.8,701.8,701.9 | | | | | | 8) NOTE: PLEASE SEE 700.1 AND 701.1 | | | EMERGENCY AND LEGALLY REQUIRED SYSTEMS | | | MAY NOT OCCUPY THE SAME ELECTRICAL | | | DISTRIBUTION EQUIPMENT RACEWAYS ETC. | | | PLEASE SEE PANEL "E" IS THE SAME DIST | | | EQUIPMENT WHICH FEEDS EM/LEGALLY AND | | | OPTIONAL STAND-BY SYSTEMS.700.9, | | | 701.10ETC | | | ** PLEASE CLARIFY SYSTEMS AS SHOWN AS IT | | | IS UNCLEAR WHY ALL ARE BEING SHOWN AS | | | REQUIRED LS OR EM SYSTEM. | | | | | | 9) NOTE: PLEASEKNOW THAT ALL CODES | | | RELEVANT TO THE DESIGN AND SCOPE PF WORK | | | SHALL BE STATED ON PLANS. PLEASE SEE | | | THAT THE FOLLOWING IS REQUIRED AT A | | | MINIMUM. PLEASE KNOW AS OF JULY 1ST 2003 | | | THE 2002 NEC WAS ADOPTED BY THE STATE. | | | PLEASE SEE "A" SHEET WHICH SHOWS 99. | | | 2002 NFPA-70, 2002 NFPA-72, 2003 | | | NFPA-101, 2002 NFPA-110, 2004 FBC | | | | | | 10) NOTE: PLEASE SEE NFPA-110 7.2.2.1 AS | | | TWICE THECLEARANCE DISTANCE FOR ATS | | | IS REQUIRED IN MAIN ELECTRICAL ROOM AS | | | REQUIRED PER 110.26 | | | | | | 11) NOTE: PLEASE SEE NFPA-110 CHAPTER 7 | | | AS THE ELEVATION OF THE GENERATOR IS NOT | | | STATED. PLEASE SEE MOUNTING ETC AS | | | REQUIRED. PLEASE SEE THE ELEVATION IS | | | REQUIRED AT A MIN OF 6" ABOVE THE | | | FLOODING LEVEL (BFE) IF IN A FLOOD ZONE. | | | PLEASE SEE 7.4 AND BUILDING REVIEW | | | COMMENTS FOR REQUIRED SLAB DETAIL. | | | | | | 12) NOTE: PLEASE SEE MISSING DISCONNECTS | | | FOR RTU'S WHICH COULD NOT BE LOCATED ON | | | PLANS. CAN BE TYPICAL IF THE SAME. | | | 440.11 | | | PLEASE ALSO SEE MISSING ROOF TOP GFI'S | | | WHICH COULD NOT BE LOCATED ON PLANS FOR | | | ROOF. | | | 230.63, 210.8 | | | | | | 13) NOTE: PLEASE SEE MISSING THE | | | REQUIRED DEDICATED CIRCUITS FOR THE | | | ELEVATOR MACHINE ROOM. | | | 620.23,620.24 | | | | | | 14) NOTE: PLEASE SEE THAT AN EMERGENCY | | | LT FIXTURE OF SOME SORT WITH BATTERY | | | BACK UP WILL BE REQUIRED IN THE MAIN | | | ELECTRICAL ROOM AND THE ELEVATOR MACHINE | | | ROOM. | | | 7.9.2.2, 700.16, 90.4 | | | | | | 15) NOTE: PLEASE SPECIFY THE MAX OVER | | | RIDE TIMES FOR THE OCCUPANT SENSORS. | | | 30MIN MAX FOR SENSORS AND 4HRS MAX FOR | | | TIMER TYPE OVER RIDES. | | | PLEASE ALSO SEE SEPARATE SPACES/ROOMS | | | WHICH SEEM TO BE MISSING OVER RIDE | | | CONTROLS. | | | PLEASE SEE FBC 13-415.1.ABC.1.1, .1.2, | | | .1.3 | | | | | | 16) NOTE: PLEASE VERIFY HOW THE ENERGY CALCULATIONS | | | SUBMITTED ALL MENTIONS AND | | | CONTAIN "MANUAL ON/OFF" CONTROLS FOR | | | LIGHTING?? | | | PLEASE SEE METHODS REQUIRED PER | | | 13-415.1.AB.1. | | | | | | 17) NOTE: PLEASE SUBMIT LIGHTING POWER | | | DENSITY CALCULATIONS AS REQUIRED. | | | 13-415.1.AB.1,13.415.2.ABC.1 AND TABLES | | | 415.2.C.1 AND 415.2.B.1 | | | | | | 18) NOTE: PLEASE SEE MISSING GROUNDING | | | ELECTRODE DETAIL FOR THE GROUNDING | | | ELECTRODE SYSTEM. PLEASE SEE MISSING NEW | | | FOOTER STEEL ETC | | | 250.50 | | | | | | 20) NOTE: PLEASE SEE 250.66 FOR MIN | | | SIZING OF THE GEC. APPEARS THIS SHOULD | | | BE 2/0 MIN. | | | | | | 21) NOTE: PLEASE CLARIFY THE SEPARATION | | | OF TENANTS. PLEASE SEE PLANS AS SHOWN | | | HAS CIRCUITING FROM EACH TENANT SERVICE | | | CROSSING OVER INTO OTHER TENANT'S AREAS | | | AND ROOMS. IF THEBUILDINGS GOING TO | | | HAVE "HOUSE" POWER THESE MAY NOT FEED | | | INTO TENANT SPACES. PLEASE ALSO SEE | | | CIRCUITS FOR UPPER TENANT MAY NOT FEED | | | AREAS IN LOWER TENANTS. PLEASE SEE PROPER | | | TENANT SEPARATION AND CROSSING OVER OF | | | CIRCUITS AND COMMON AREAS. PLEASE ADJUST CIRCUITING ON | | | PLANS. | | | PLEASE SEE "HOUSE" PANELS LOCATED ON | | | FIRST FLR TENANTS SPACE? | | | THIS IS UNCLEAR WHAT IS BEING PROPOSED | | | IN THIS DESIGN | | | | | | 22) NOTE: PLEASE SEE AS KNOW "SCHEDULE | | | WAS SUBMITTED FOR THE 800A | | | BUS/METER CENTER, PLEASE INDICATE THE | | | CONDUCTORS FROM THE MAIN BUS TO EACH OF | | | THE ATS UNITS. | | | 215.5, 240.4,310.16 | | | | | | 23) NOTE: PLEASE KNOW , DEPENDING ON | | | OUTCOME OF SERVICE, PLEASE BE SURE TO | | | LABEL MAINS. | | | 230.2E ETC | | | | | | 24) NOTE: PLEASE VERIFY NEW OR EXISTING | | | REQUIRED SIGN CIRCUIT PER 600.5 | | | | | | 25) NOTE: PLEASE VERIFY AND SHOW LOAD | | | CALCULATIONS FOR SERVICE AND GENERATOR. | | | PLEASE SEE 220.3,220.10,220.11,220.13, | | | ETC | | | PLEASE SHOW ALL CONTINUOUS LOADS AT 125%.215.3,230.42 | | | | | | 26) NOTE: PLEASE INDICATE THE GROUNDING | | | ELECTRODE SYSTEM AT THE GENERATOR. | | | 250.30,250.20, 250.50 | | | | | | 27) NOTE: PLEASE INDICATE THE OCP AT THE GENERATOR. | | | 106.1.2, 700,701, 702 | | | | | | 28) NOTE: PLEASE SEE POSSIBLE FIRE AND | | | BUILDING REVIEW COMMENTS AS IT DID NOT | | | SEEM PLANS WERE SUBMITTED FOR ANY | | | BUILDING FIRE ALARM SYSTEM? | | | | | | ** PLEASE BE AWARE OF ANY COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT THE | | | ELECTRICAL PLANS. | | | | | | ** PLEASE KNOW AS THERE ARE ITEMS WHICH | | | WERE NOT SUBMITTED FOR REVIEW AND | | | POSSIBLE CHANGES IN DESIGN, THERE MAY BE | | | OTHER COMMENTS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-31 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-31 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2006-10-31 15:04:00 | MATTHEW HAROLD SENT SHEETS C-4 & C-5AT 45TH STREET | | | WITH ALL ENG CORRECTIONS PREVIOUSLY ASKED FOR.MR | | | HAROLD ALSO SAID THAT HE IS GOING TO SEND REVISED PLANS | | | WITH ALL OTHER DISCIPLINE'S CORRECTIONS TO CITY HALL | | | CONST. SERVICES.IT IS APPROVED FOR ENG. REVIEW WHILE | | | AT 45TH STREET.RASIK CHOKSHI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-02 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-02 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | AGAIN FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE TELL US WHAT IS YOUR | | | MAINTENANCE PLAN FOR EX-FILTRATION | | | PIPES,TRENCH ETC., TO KEEP CLEAN & | | | UNPLUG HOLES. MAY BE A GOOD IDEA TO KEEP | | | SWALE IN GRASS AREA AROUND THE SITE, | | | OTHERWISE WATER FROM THIS SITE WILL GO | | | TO AUSTRALIAN AVE OR BACK IN THE LAKE | | | WHICH WE DO NOT WANT. | | | 2. YOU HAVE NOT SHOWN ANY CATCH BASINS | | | NEXT TO YOUR SITE ON EITHER | | | DIRECTION.PLEASE SHOW. | | | 3. PLEASE SHOW PLACE FOR A DUMPSTER | | | ENCLOSURE WHICH MUST MEET STANDARDS OF | | | CITY OF WPB. | | | 4. DRAWINGS ARE NOT SEALED & SIGNED | | | | | | PLEASE RESPOND EACH ITEM ASKED FOR. | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-09-15 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-09-15 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2006-09-15 00:00:00 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE SHOW HOW WAS EXFILTERATION | | | TRENCH LENGTH DETERMINED? NEED CAL. | | | CRITERIA FOR RUNOFF CAL., PLEASE SHOW | | | CONTROL STRUCTURES DETAILS, ( C-4, | | | CA,ETC,ON SHEET C-5) SFWMD PERMIT, | | | | | | 2. PLEASE SHOW ALL CATCH BASINS IN | | | SURROUNDING AREA OF THE SITE. PLEASE | | | SHOW ROAD, SIDEWALK, PARKING LOT, FIRST | | | FLOOR ELEVATION, MAKE SURE AREA DO NOT | | | GET FLOODED. | | | | | | 3. SHOW ALL WATER/SEWER MAINS,DRAINAGE | | | WATER CONNECTIONS ON THE DRAWINGS. | | | UTILITY (45TH STREET) MUST APPROVE | | | BEFORE WE APPROVE. | | | | | | 4. SHOW NOTES ANDSHOW DUMPSTER | | | ENCLOSURE DETAILS,SIDE WALK | | | DETAIL,PARKINGS, MUST MEET CITY OF WPB | | | STANDARDS. ADA ETC., | | | | | | PLEASE RESPOND EACH ITEMS, SEPARATELY | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
N |
Date |
2008-06-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-06-17 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-06-17 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2008-06-17 16:04:00 | *****NO REVIEW***** | | | | | | PLAN REVIEW FOR THE FIRE ALARM AND FIRE SPRINKLER | | | AS-BUILTS CAN NOT BE CONDUCTED UNDER BUILDING PERMIT. | | | ANY REVISIONS SHALL BE MADE UNDER THE APPROPIATE SUB | | | PERMIT.PLEASE BE ADVISED THAT PERMIT 07051013 (FIRE | | | SPRINKLER) WAS FINALED 5/29/08, AND ON 5/23/08 PERMIT | | | 07090086 WAS FINALED | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-02-19 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-02-19 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2008-02-19 15:51:15 | REVISION DATED 11/28/07 STAMPED SHEETS F1-01-101 AND | | | F1-02-101. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-05-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-05-02 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-05-02 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2007-05-02 14:17:53 | ***PROVISO*** | | | | | | 1) IT APPEARS THAT PREVIOUS FIRE COMMENTS HAVE BEEN | | | ADDRESSED. | | | | | | 2) YOUR RESPONSE TO THE FIRST FIRE REVIEW #14 REFERS | | | THIS WRITER TO ELECTRICAL COMMENTS. THE PLANS WILL BE | | | STAMPED WITH THE REQUIREMENT FOR UL LISTING FOR CENTRAL | | | STATION SERVICE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-02-15 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-02-15 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2007-02-15 10:56:03 | ***DENIED*** | | | | | | 1 OK | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4) SEE ELECTRICAL COMMENTS. | | | | | | 5) RESPONSE INDICATES FBC. IN ADDITION, PLEASE ADD NOTE | | | REFERENCING NFPA 241. | | | | | | 6) OK | | | | | | 7) OK | | | | | | 8) NO SHEET FOUND IN EACH SET OF PLANS. | | | | | | 9) OK | | | | | | 10) OK | | | | | | 11) OK | | | | | | 12) OK | | | | | | 13) OK | | | | | | 14) FIRE COMMENTS HAVE BEEN REFERRED TO ELECTRICAL. | | | PLEASE ACKNOWLEDGE AND ADD TO PLANS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | (561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-17 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-10-17 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2006-10-17 14:25:52 | ***DENIED*** | | | | | | 1) FIREAND SMOKE DAMPER INSTALLATIONS TO BE DROP | | | TESTED PRIOR TO FINAL INSPECTION. | | | | | | 2) FIRE DEPARTMENT CONNECTIONS SHALL BE SECURED WITH | | | KNOX LOCKING CAPS. | | | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER AND FIRE ALARM SYSTEMS. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED FOR | | | GENERATOR AND EQUIPMENT. PLEASE SUBMIT MANUFACTURER | | | SPEC SHEETS. | | | | | | 5) CONSTRUCTION, ALTERATION AND DEMOLITION SHALL COMPLY | | | WITH NFPA 241. | | | | | | 6) PLEASE PROVIDE MINIMUM INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILING. | | | | | | 7) PLANS SHOW ACCESS TO ROOF. PLEASE PROVIDE FURTHER | | | INFORMATION REGARDING THIS ARRANGEMENT. | | | | | | 8) AN ADDRESS IS REQUIRED ON BUILDING AND SHALL BE | | | MINIMUM OF 6" IN HEIGHT, 1" IN WIDTH AND CONTRASTING TO | | | BACKGROUND. PLEASE SHOW ON ELEVATIONS. | | | | | | 9) PLEASE PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENT FOR | | | HANDRAILS AND GUARDS. | | | | | | 10) STAIRS TO COMPLY WITH NFPA 101, SECTION 7.2.2.2.1 | | | (A). | | | | | | 11) PLEASE ILLUSTRATE FIRE RATING OF DOORS IN MINUTES. | | | SHT A-800-101 (DOOR SCHEDULE). | | | | | | 12) FIRE RATED DOORS SHALL CLOSE AND LATCH UTILIZING UL | | | LISTED CLOSERS. | | | | | | 13) FIRE PROTECTION SHEETS SHOW THE FDC AT SOUTH SIDE | | | OF BUILDING AND E SHEETS SHOW THE CONNECTION AT NORTH | | | SIDE OF BUILDING. PLEASE CLARIFY CORRECT LOCATION. | | | | | | 14) FIRE ALARM SYSTEM TO BE UL CERTIFIED FOR CENTRAL | | | STATION SERVICE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-15 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-15 |
Time |
10:04 |
Sent To |
E |
|
| Notes |
| 2008-08-15 10:05:11 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-07 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-07 |
Time |
09:11 |
Sent To |
P |
|
| Notes |
| 2008-08-07 09:12:58 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-11 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-11 |
Time |
10:54 |
Sent To |
E |
|
| Notes |
| 2008-07-11 10:55:01 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-11 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-11 |
Time |
10:52 |
Sent To |
P |
|
| Notes |
| 2008-07-11 10:52:31 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2008-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-25 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-25 |
Time |
10:25 |
Sent To |
B |
|
| Notes |
| 2008-06-25 10:26:09 | TO "HMOSER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-03 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-03 |
Time |
12:20 |
Sent To |
E |
|
| Notes |
| 2008-06-03 12:20:56 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-30 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-30 |
Time |
15:32 |
Sent To |
FIRE |
|
| Notes |
| 2008-05-30 15:33:13 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-20 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-20 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2008-05-22 13:21:47 | TO "COMM" BD#19 | | 2008-05-20 12:28:03 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-16 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-16 |
Time |
11:11 |
Sent To |
E |
|
| Notes |
| 2008-05-16 11:12:16 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-15 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-15 |
Time |
12:36 |
Sent To |
B |
|
| Notes |
| 2008-05-15 12:36:31 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-29 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-29 |
Time |
10:43 |
Sent To |
B |
|
| Notes |
| 2008-04-29 10:44:19 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-29 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-29 |
Time |
10:25 |
Sent To |
E |
|
| Notes |
| 2008-04-29 10:27:36 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-18 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-18 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
| 2008-04-18 14:16:43 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-14 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-14 |
Time |
10:02 |
Sent To |
M |
|
| Notes |
| 2008-03-14 10:02:49 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-29 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-29 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2008-02-29 08:58:37 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-29 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-29 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2008-02-29 08:40:50 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-02-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-02-04 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-02-04 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2008-02-04 16:58:41 | TO "COMM" BD#33 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-12 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-12 |
Time |
09:23 |
Sent To |
B |
|
| Notes |
| 2007-12-12 09:25:05 | TO "SHILL" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-08 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-08 |
Time |
08:37 |
Sent To |
B |
|
| Notes |
| 2007-11-08 09:07:12 | TO "SHILL' DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-26 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-26 |
Time |
10:14 |
Sent To |
B |
|
| Notes |
| 2007-10-26 10:14:32 | TO "SHILL" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-25 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-25 |
Time |
10:06 |
Sent To |
B |
|
| Notes |
| 2007-09-25 10:06:21 | TO "SHILL' DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-12 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-12 |
Time |
16:44 |
Sent To |
B |
|
| Notes |
| 2007-09-12 16:45:20 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-06 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-06 |
Time |
11:47 |
Sent To |
B |
|
| Notes |
| 2007-06-06 11:48:17 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-06 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-06 |
Time |
11:36 |
Sent To |
E |
|
| Notes |
| 2007-06-06 11:36:30 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-14 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-14 |
Time |
16:48 |
Sent To |
E |
|
| Notes |
| 2007-05-14 16:48:25 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-02 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-02 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2007-04-02 17:18:18 | TO COMM BOARD # 61 RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-29 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-29 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2007-03-29 18:42:36 | WAITING FOR COMM BOARD. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-29 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-29 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2007-01-29 08:35:37 | TO "COMM" BD#39 | | 2006-12-29 10:22:02 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-17 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-01 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2006-09-07 00:00:00 | TO "COMM" BD#48 | | 2006-09-01 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-27 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-27 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2008-06-27 10:37:19 | REVISED ENERGY CALCULATIONS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-06-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-06-26 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-06-26 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-14 |
Time |
16:15 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-03-14 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2008-03-14 16:16:40 | REVISION TO MECH. PLAN PAGE M1-02-101. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-19 |
Time |
11:20 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-02-19 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2008-02-19 11:22:11 | REVISION TO MECH. PLANS PAGES M1-01-101, M1-02-101, | | | M6-00-101, AND COOLING LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-04-26 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-04-25 |
Time |
19:06 |
Sent To |
|
|
| Notes |
| 2007-04-26 07:51:34 | *************PROVISO************ | | | | | | EF-5: AIR REMOVED BY MECHANICAL EXHAUST SHALL BE | | | DISCHARGED OUTDOORS (NOT INTO PARKING GARAGE) PER FBC,M | | | 501.2. ALSO, OPENING PROTECTIVE (FIRE DAMPER) IS | | | REQUIRED AT WALL PENETRATION INTO GARAGE PER FBC,M | | | 607.5. REVISION REQUIRED TO SHOW THESE CORRECTIONS | | | PRIOR TO ROUGH INSPECTION. | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-02-12 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-02-12 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2006-10-16 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2006-10-14 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2006-10-16 17:20:01 | -------------------DENIED------------------- | | | 1. PG.M1-02-101 SHOWS 1 HOUR RATED SHAFT WITH DUCTS TO | | | FIRST FLOOR. PLEASE PROVIDE DETAIL FOR SHAFT | | | TERMINATION AT 2ND FLOOR LEVEL IN COMPLIANCE WITH FBC | | | 707.11 | | | | | | 2. PG.M1-02-101 PENETRATIONS INTO A MEANS-OF-EGRESS | | | STAIRWELL ARE PROHIBITED PER FBC 1019.1.2 | | | | | | 3. PG.M1-02-101 SHAFT ENCLOSURES PERMITTED TO BE | | | PENETRATED BY DUCTS SHALL BE PROTECTED BY APPROVED FIRE | | | AND SMOKE DAMPERS INSTALLED IN ACCORDANCE WITH THEIR | | | LISTING PER FBC,M 607.5.5.1 | | | | | | 4. PG M1-01-101 ROOMS 121 AND EM2 SHOW FIRE DAMPERS ON | | | TRANSFER OPENINGS BUT NOT AT SUPPLY DUCTS. DUCT | | | PENETRATIONS IN FIRE BARRIERS SHALL BE PROTECTED WITH | | | APPROVED FIRE DAMPERS IN ACCORDANCE WITH THEI RLISTING | | | PER FBC,M 607.5.2 | | | | | | 5. PG.M7-00-101 DETAIL #8 FIRE DAMPERS ARE TO BE UL555 | | | LISTED AND INSTALLED PER MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AND LISTING PER FBC,M 607.2 | | | | | | 6. PG M1-0R-101 PLEASE SHOW MEANS OF CONDENSATE | | | DISPOSAL TO BE IN COMPLIANCE WITH FBC,M 307.2.1 AND FBC | | | 1503.6.AUXILIARY DRAIN PROTECTION IS ALSO REQUIRED | | | PER FBC,M 307.2.3 | | | | | | 7. PG.M7-00-101 ROOFTOP EQUIPMENT REQUIRES AN | | | ENGINEERED SYSTEM TO SHOW COMPLIANCE WITH WIND LOAD | | | REQUIREMENTS PER FBC,M 301.13. PLEASE PROVIDE DETAIL | | | SHOWING ROOF-TO-CURB AND CURB-TO-EQUIPMENT ATTACHMENTS. | | | NOTE: THE CITY OF WEST PALM BEACH IS IN THE 140MPH WIND | | | ZONE PER FBC CHAPTER 16. | | | | | | 8. PG.M1-01-101 SEE BUILDING PLAN REVIEW COMMENT #11 | | | REGARDING DUCT PENETRATIONS INTO GARAGE. THERE ARE ALSO | | | TWO DUCTS PENETRATING RATED WALL AT ROOM EM1. | | | | | | REVIEWED BY: | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2008-08-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-20 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-20 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2008-08-20 10:34:23 | REVISIONS OK--SHTS P1-01-101 & P1-02-101 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-23 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-23 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2008-07-23 15:14:41 | REVISIONS DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHTS P1-01-101, P1-02-101 & P7-00-001 INDICATE | | | REVISION #4 IN THE REVISION INDEX, BUT NO CLOUD OR | | | REVISION NUMBER IS SHOWN. SECTION 106.1.3. PLEASE CLOUD | | | ALL REVISIONS AND INDICATE REVISION NUMBER FOR EACH | | | REVISION SUBMITTED. | | | | | | 2. SHTS P1-0R-101 & P7-00-002 INDICATE REVISION #3 IN | | | THE REVISION INDEX, BUT NO CLOUD OR REVISION NUMBER IS | | | SHOWN. SECTION 106.1.3. PLEASE CLOUD ALL REVISIONS AND | | | INDICATE REVISION NUMBER FOR EACH REVISION SUBMITTED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-06-05 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-06-05 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2008-06-05 10:44:26 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHTS P1-01-101 & P1-02-101 HAVE BEEN SUBMITTED AS | | | PHOTO COPIES AND WITH HAND DRAWN CHANGES TO ORIGINAL | | | SIGNED, SEALED, DATED PLANS. ALL CHANGES TO SIGNED, | | | SEALED & DATED PLANS SHALL BE SUBMITTED AS NEW | | | REVISIONS, CLOUDED AND INDICATED WITH A REVISION NUMBER | | | AND SHALL BE SIGNED, SEALED AND DATED BY THE ENGINEER | | | OF RECORD. SECTION 106.1, FAC 61G15-23.002(2) & FS | | | 471.025. | | | | | | 2. ALL CHANGES TO THE PLUMBING SANITARY, WATER, STORM, | | | CONDENSATE, OR GAS SYSTEMS SHALL BE REFLECTED WITH | | | REVISIONS TO THE ISOMETRIC RISER DIAGRAMS OF EACH | | | SYSTEM THAT IS REVISED. SECTION 106.3.5.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-03-03 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-03-03 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2008-03-03 15:36:28 | REVISIONS APPROVED. SHTS P1-OR-101, P1-01-101, | | | P1-02-101, P7-00-001 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-05-09 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-05-09 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-02-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-07 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-06 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2007-02-07 10:22:54 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. DELETED | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. DELETED | | | 7. OK | | | | | | 8. SHT A7-01-101 ELEVATION 1 KITCHEN | | | SINK TO COMPLY WITH SECTION 11-4.24 AND | | | ALL SUBSECTIONS. SHOW ON DETAIL. | | | ****RESPONSE NOTED, INFORMATION STILL REQUIRED. SHOW | | | COMPLIANCE WITH THE FOLLOWING: | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.5 CLEAR FLOOR SPACE - FORWARD APPROACH | | | REQUIRED. SHOW ON THE FLOOR PLAN OF SHT A9-03-101 TO | | | SEE IF FURNITURE WILL CONFLICT WITH THE CLEAR FLOOR | | | SPACE. | | | E. 11-4.24.7 FAUCETS. | | | | | | 9.OK | | | 10. OK | | | | | | 11. SHT A7-02-101 ELEVATION 13, STAFF | | | SINK SHALL COMPLY WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. SUBMIT INFORMATION | | | ON DETAIL. | | | ****RESPONSE NOTED, BUT SUCH INFORMATION SHALL BE | | | SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS | | | A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. SHOW COMPLIANCE WITH THE FOLLOWING: | | | A. 11-4.24.3 KNEE CLEARANCE | | | B. 11-4.24.4 SINK DEPTH | | | C. 11-4.24.5 CLEAR FLOOR SPACE - FORWARD APPROACH | | | REQUIRED. SHOW ON THE FLOOR PLAN OF SHT A9-03-101 TO | | | SEE IF FURNITURE WILL CONFLICT WITH THE CLEAR FLOOR | | | SPACE. | | | D. 11-4.24.7 FAUCETS. | | | | | | 12. SHTS A9-01-201 & AP-02-201 ROOMS | | | 108, 126, 127, 205, 206, 214. TOILET | | | ROOM FLOORS & WALLS SHALL BE SMOOTH, | | | HARD AND NONABSORBENT PER SECTIONS | | | 1210.1 & 1210.2. THE BASE IS INDICATED | | | AS T2 WHICH IS NOT SHOWN UNDER THE BASE INFORMATION, | | | BUT AS "TBD" UNDER THE | | | FLOOR INFORMATION. WALLS ARE INDICATED | | | AS P5 OR P6. PLEASE SUBMIT INFORMATION | | | SHOWING HOW A PAINTED WALL CAN COMPLY | | | WITH REQUIREMENTS OF "HARD & | | | NONABSORBENT". SHOW BASE MATERIAL. | | | ****RESPONSE NOTED, BUT ROOM 108 STILL SHOWS PAINT ON | | | THE EAST WALL. SECTION 1210.2 STATES "WALLS WITHIN 2' | | | OF URINALS AND WATER CLOSETS".--THE FINISH SCHEDULE | | | DOES NOT SHOW T1 IN THE BASE INFORMATION, NOR DOES IT | | | SHOW T1/T3 IN THE WALL INFORMATION.--ROOM 205 SHOWS | | | T1/T3 ON THE NORTH & SOUTH WALLS, BUT IT IS REQUIRED ON | | | THE SOUTH, EAST, & WEST WALLS.--ROOM 206 SHOWS | | | T1/T3 ON THE NORTH & SOUTH WALLS, BUT IT IS REQUIRED ON | | | THE NORTH, EAST & WEST WALLS.--ROOM 214 SHOWS T1/T3 | | | ON THE EAST WALL ONLY, BUT IT IS ALSO REQUIRED ON THE | | | SOUTH WALL. PLEASE INDICATE THE REQUIRED FINISH ON THE | | | REQUIRED WALLS.--PLEASE UPDATE THE FINISH SCHEDULES | | | TO INCLUDE THE FINISH SHOWN ON THE BASE & WALLS. | | | | | | 13. OK | | | 14. OK | | | 15. OK | | | 16. OK | | | 17. OK | | | 18. OK | | | 19. OK | | | 20. OK | | | | | | **************NEW COMMENT************* | | | | | | 1B. SHT P1-01-101 INDICATES A SHOWER TRAP IN THE | | | CEILING OF THE ELECTRIC METER ROOM. THIS IS NOT | | | APPROVED PER NFPA 70 SECTION 110.26.--THIS SHEET | | | ALSO INDICATES A DRAIN PAN UNDER THE PIPING DISCHARGING | | | TO THE GARAGE. THIS WILL BE WASTE WATER AND CAN NOT | | | DRAIN TO THE GARAGE. ALL PLUMBING FIXTURES, DRAINS, | | | APPURTENANCES AND APPLIANCES USED TO RECEIVE OR | | | DISCHARGE LIQUID WASTES OR SEWAGE SHALL BE DIRECTLY | | | CONNCETED TO THE SANITARY DRAINAGE SYSTEM. SECTION | | | 301.3. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-11 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-09 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL CIVIL SHEETS, THE BUSINESS NUMBER (CERTIFICATE | | | OF AUTHORIZATION) IS | | | REQUIRED IN THE TITLE BLOCK ON EACH | | | SHEET. FAC 61G1-16.004(2), FAC | | | 61G15-23.002(2), FS 481.219. & FS | | | 481.2055. BOTH CA#'S ARE REQIRED FOR THE ENGINEERING | | | AND THE SURVEYO PORTION OF | | | THE BUSINESS IN THE TITLE BLOCK PER | | | DBPR. | | | | | | 2. ALL ARCHITECTURAL SHEETS. THE TITLE | | | BLOCK SHALL SHOW THE DATE PREPARED, | | | DATED SEAL, PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT. | | | 61G1-16.004(4)(5)(6) & FS 481.2055. | | | | | | 3. SHT A0-00-001 THE FOLLOWING | | | INFORMATION IS REQUIRED TO SHOW | | | COMPLIANCE WITH ACCABILITY REQUIREMENTS: | | | A. 11-4.18.2 HEIGHT (SHOWS 19") | | | B. 11-4.18.3 CLEAR FLOOR SPACE | | | C. 11-4.19.5 FAUCETS (LAV) | | | | | | 4. SHT A0-01-301 DEMO KEY NOTES #3. | | | INDICATE THAT DEAD ENDS ARE PROHIBITED | | | PER SECTION 704.5. | | | | | | 5. SHT A1-0R-001 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107 WITH ALL | | | SUBSECTIONS. SHOW THE SQUARE FOOTAGE | | | BEING DRAINED BY EACH ROOF DRAIN. | | | CALCULATIONS SHALL SHOW ROOF AREA PLUS | | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS, ALONG WITH ALL AREAS OF ROOF | | | THAT DRAIN ONTO THE ROOF FROM ABOVE. | | | | | | 6. SHT A2-02-001 DETAIL #4 SHOWS THE | | | COUNTERTOP AT 36". MAX 34" TO SINK PER | | | 11-4.24.2. | | | | | | 7. SHT A5-00-103 DETAIL #7 OVERFLOW | | | SCUPPERS TO BE 2" TO 4" ABOVE THE ROOF | | | TO THE FLOW LINE. (SHOW AS EVEN WITH | | | ROOF). ALSO THE MINIMUM HEIGHT IS 4". | | | (SHOWN AS 3"). SECTION 1503.4.3 AND | | | SECTION 1107.3. | | | | | | 8. SHT A7-01-101 ELEVATION 1 KITCHEN | | | SINK TO COMPLY WITH SECTION 11-4.24 AND | | | ALL SUBSECTIONS. SHOW ON DETAIL. | | | | | | 9. SHT A7-01-101 ELEVATIONS 7, 13, 17. | | | FLUSH CONTROLS TO BE LOCATED ON THE WIDE | | | SIDE TO THE W/C TANK. SECTION 11-4.16.5. | | | | | | 10. SHT A7-02-101 ELEVATIONS 2, 8 , 11 | | | FLUSH CONTROLS SHALL BE LOCATED ON THE | | | WIDE SIDE OF THE W/C TANK. SECTION | | | 11-4.16.5. | | | | | | 11. SHT A7-02-101 ELEVATION 13, STAFF | | | SINK SHALL COMPLY WITH SECTION 11-4.24 | | | AND ALL SUBSECTIONS. SUBMIT INFORMATION | | | ON DETAIL. | | | | | | 12. SHTS A9-01-201 & AP-02-201 ROOMS | | | 108, 126, 127, 205, 206, 214. TOILET | | | ROOM FLOORS & WALLS SHALL BE SMOOTH, | | | HARD AND NONABSORBENT PER SECTIONS | | | 1210.1 & 1210.2. THE BASE IS INDICATED | | | AS T2 WHICH IS NOT SHOWN UNDER THE BASE INFORMATION, | | | BUT AS "TBD" UNDER THE | | | FLOOR INFORMATION. WALLS ARE INDICATED | | | AS P5 OR P6. PLEASE SUBMIT INFORMATION | | | SHOWING HOW A PAINTED WALL CAN COMPLY | | | WITH REQUIREMENTS OF "HARD & | | | NONABSORBENT". SHOW BASE MATERIAL. | | | | | | 13. SHTP1-01-101 ELEVATOR SUMP PUMPS. | | | PLUMBING SYSTEMS SHALL NOT BE LOCATED IN | | | AN ELEVATOR SHAFT, OR IN AN ELEVATOR | | | EQUIPMENT ROOM. SECTION 301.6. OIL FROM | | | THE ELEVATOR SHAFT SHALL NOT BE | | | DEPOSITED INTO THE SEWER SYSTEM. SECTION | | | 302.1. THIS IS CONSIDERED HAZARDOUS | | | MATERIAL AND SHALL BE CONTAINED AND | | | RECYCLED. | | | | | | 14. SHT P1-01-101 DEAD ENDS ARE | | | PROHIBITED PER SECTION 704.5. ALL | | | SANITARY PIPING SHALL BE DEMO'D AT THE | | | MAIN LINE. ALL CAPPED PIPING SHALL BE | | | INSPECTED PRIOR TO COVERING. | | | | | | 15. SHT P1-01-101 INDICATE WHAT "SW" | | | FIXTURE IS. DESIGNATION NOT SHOWN ON THE | | | PLUMBING CONNECTION FIXTURE SCHEDULE. | | | | | | 16. SHT P7-00-001 SUBMIT THE SANITARY | | | RISER DIAGRAM IN ISOMETRIC FORM THAT | | | REFLECTS THE FLOOR PLAN. SHOW ALL DFU'S | | | AS THEY ACCUMULATE IN THE SYSTEM. | | | SECTIONS 106.1.1 AND 106.3.5.1.3. (SEE | | | ATTACHED SHEET FOR AN EXAMPLE OF A | | | PORTION OF THE SANT. RISER ISOMETRIC | | | DIAGRAM THAT REFLECTS THE FLOOR PLAN). | | | RISER DIAGRAMS AS DRAWN ARE NOT | | | ACCEPTABLE AND DO NOT REFLECT THE FLOOR | | | PLAN. | | | | | | 17. SHT P7-00-001 W/C NOT VENTED AS | | | DRAWN. (TOILET ROOM BY OFFICE ROOM 107). | | | (SEE ATTACHED EXAMPLE OF ISOMETRIC FOR | | | CORRECT VENTING OF W/C). | | | | | | 18. SHT P7-00-002 DETAIL #2 WATER HEATER | | | PAN REQUIRES A PAN DRAIN. SECTION | | | 504.7.1. | | | | | | 19. SHT P7-00-002 DETAIL #3 SUBMIT | | | MANUF. SPECIFICATION SHEETS FOR TANKLESS | | | WATER HEATER. MUST SHOW LISTING. SECTION | | | 303.4. | | | | | | 20 ALL PME SHEETS ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME, ADDRESS, | | | AND LICENSE NUMBER ON EACH SHEET. SEAL | | | HAS NOT BEEN DATED (WHEN SEAL IS AFFIXED | | | TO PLANS), NOR IS THE PRINTED NAME OF | | | THE ENGINEER INDICATED. FAC | | | 61G15-23.002(2) AND FS 471.025. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-04-17 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-04-16 |
Time |
11:23 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-02-06 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-02-06 |
Time |
15:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-10-12 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
LFRANCO |
Date |
2006-10-12 |
Time |
19:26 |
Sent To |
|
|
| Notes |
|
|