Plan Review Details - Permit 06082182
| Plan Review Stops For Permit 06082182 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-24 |
Time |
10:23 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-01-24 |
Time |
07:39 |
Sent To |
PC |
|
| Notes |
| 2007-01-24 10:22:58 | | | | THE FOLLOWING CODE ARTICLES MUST BE COMPLIED WITH | | | REGARDING THIS INSTALLATION. | | | | | | (B) GROUNDED CONDUCTOR BROUGHT TO SERVICE EQUIPMENT. | | | WHERE AN AC SYSTEM OPERATING AT LESS THAN 1000 VOLTS IS | | | GROUNDED AT ANY POINT, THE GROUNDED CONDUCTOR(S) SHALL | | | BE RUN TO EACH SERVICE DISCONNECTING MEANS AND SHALL BE | | | BONDED TO EACH DISCONNECTING MEANS ENCLOSURE. THE | | | GROUNDED CONDUCTOR(S) SHALL BE INSTALLED IN ACCORDANCE | | | WITH 250.24(B)(1) THROUGH (B)(3). | | | | | | 1) ROUTING AND SIZING. THIS CONDUCTOR SHALL BE ROUTED | | | WITH THE PHASE CONDUCTORS AND SHALL NOT BE SMALLER THAN | | | THE REQUIRED GROUNDING ELECTRODE CONDUCTOR SPECIFIED IN | | | TABLE 250.66 BUT SHALL NOT BE REQUIRED TO BE LARGER | | | THAN THE LARGEST UNGROUNDED SERVICE-ENTRANCE PHASE | | | CONDUCTOR. IN ADDITION, FOR SERVICE-ENTRANCE PHASE | | | CONDUCTORS LARGER THAN 1100 KCMIL COPPER OR 1750 KCMIL | | | ALUMINUM, THE GROUNDED CONDUCTOR SHALL NOT BE SMALLER | | | THAN 12? PERCENT OF THE AREA OF THE LARGEST | | | SERVICE-ENTRANCE PHASE CONDUCTOR. THE GROUNDED SERVICE | | | ENTRANCE CONDUCTOR OF A 3-PHASE, 3-WIRE DELTA SERVICE | | | SHALL HAVE AN AMPACITY NOT LESS THAN THE UNGROUNDED | | | CONDUCTORS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-29 |
Time |
14:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-29 |
Time |
12:46 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-07 |
Time |
16:11 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-09-07 |
Time |
07:19 |
Sent To |
PC |
|
| Notes |
| 2006-09-07 00:00:00 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE 3/0 CONDUCTORS DO NOT HAVE THE | | | AMPACITY FOR A 225 AMPERE FEED. 310.16. | | | IT WOULD APPEAR THAT A TAP RULE IS BEING | | | INVOKED, BUT THERE ARE NO ARTICLES FOR | | | TAP RULES FOR SERVICE CONDUCTORS, ONLY | | | FEEDERS,AND BRANCH CIRCUITS,240.21(A) | | | THROUGH (G), WHICH DOES NOT APPLY. | | | | | | 2} A DISCONNECING MEANS IS REQUIRED FOR | | | THE SERVICE CONDUCTORS PER 230.70 AND | | | LOCATED PER 230.70(A). | | | | | | 3} THERE IS NO OVERCURRENT PROTECTION | | | FOR THE SERVICE CONDUCTORS PER 230.90, | | | 240.21. | | | | | | 4} THE GROUNDING ELECTRODE CONDUCTOR | | | MUST COMPLY WITH 250.66, 1/0 FOR 500 MCM | | | SERVICE CONDUCTORS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-24 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-20 |
Time |
13:18 |
Sent To |
E |
|
| Notes |
| 2007-01-20 13:18:59 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-22 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-22 |
Time |
08:46 |
Sent To |
E |
|
| Notes |
| 2006-09-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-07 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2006-09-05 |
Time |
10:02 |
Sent To |
E |
|
| Notes |
| 2006-09-05 00:00:00 | TO "E" BOX |
|
|
|