| Plan Review Stops For Permit 06082057 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-02-28 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-02-28 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-18 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-16 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2006-12-16 17:41:10 | BUILDING PLAN REVIEW | | | PERMIT:06082057 | | | ADD:1910 PALM BEACH LAKES BLVD. | | | CONT: DIGNY YORK ASSOC. LLC. | | | TEL: (703)790-528 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1) SHEET A-2WHAT WAS THEPRIOR USE OF THE NEW ADA | | | BATHROOM? | | | | | | 2) FBC. EXISTING. SEC 304.1LEVEL 2 ALTERATIONS | | | INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR | | | ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION | | | OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY | | | ADDITIONAL EQUIPMENT. | | | | | | 3)WPB AMENDMENTS.108.3.FOR PERMITTING PURPOSSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL,ELECTRIC,PLUMBING, MECHANICAL, INTERIOR | | | FINISH,ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT EXCLUDING LAND VALUE. THE VALUE ON | | | PERMIT APPLICATION SHALL BE THE TOTAL VALUE OF THE | | | PROJECT INCLUDING ALL TRADES,MATERIALS AND LABOUR. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-09-11 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-09-09 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2006-09-09 00:00:00 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1) 11-4.13.6 MANEUVERING CLEARANCES AT | | | DOORS. | | | MINIMUM MANEUVERING CLEARANCES AT DOORS | | | THAT ARE NOT AUTOMATIC OR POWER-ASSISTED | | | SHALL BE AS SHOWN IN FIGURE 11-25 . THE | | | FLOOR OR GROUND AREA WITHIN THE REQUIRED | | | CLEARANCES SHALL BE LEVEL AND CLEAR. | | | MINIMUM CLARENCE IS 18". SEE PREP ROOM | | | DOOR. SHEET A-2. | | | | | | 2) DOOR ENCROACHMENT | | | 1005.2 DOOR ENCROACHMENT . | | | DOORS OPENING INTO THE PATH OF EGRESS | | | TRAVEL SHALL NOT REDUCE THE REQUIRED | | | WIDTH TO LESS THAN ONE-HALF DURING THE | | | COURSE OF THE SWING. WHEN FULLY OPEN, | | | THE DOOR SHALL NOT PROJECT MORE THAN 7 | | | INCHES (178 MM) INTO THE REQUIRED WIDTH. | | | | | | | | | 3) 110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | | | | A) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | ------------------------------------- | | | | | | 4) 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | | BE DIMENSIONED AND DRAWN UPON SUITABLE | | | MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHEN APPROVED | | | BY THE BUILDING OFFICIAL. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN | | | DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE BUILDING OFFICIAL | | | (SEE ALSO SECTION 106.3.5). THE SYMBOL | | | IN THE LEGEND FOR THE 1-HR RATED | | | PARTITION LOOKS THE SAME FOR THE | | | EXISTING AND NEW 1-HR RATED WALL. THE | | | NEW RATED WALL NEEDS TO BE DESTINTIVE | | | FROM THE EXISTING RATED WALL, SO WE CAN | | | IDENTIFY THE NEW 1-HR RATED WALLS. | | | | | | 5) ON PAGES A-5 AND A-6 THE NEW WALLS | | | NEED TO BE CLEARLY IDENTIFY FROM THE | | | EXISTING WALLS. | | | | | | 6) THE CLAIMED VALUATION ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND | | | SSYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | COST EXCLUDING LAND VALUE. OUR VALUATION | | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT | | | AND MEANS COST ANALYSIS SERVICES PER | | | 108.3 FBC* | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | EMAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-27 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-27 |
Time |
14:31 |
Sent To |
B |
|
| Notes |
| 2007-02-27 14:45:28 | FEE BALANCEOF $2,775.00 NOT PAID, PERMIT WILL NOT | | | PRINT UNTIL FEE IS PAID. | | | | | | NEEDS RECORDED NOC BEFORE PERMIT CAN BE PICKED UP. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-21 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-21 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2006-11-21 08:54:38 | **** UNSAT 2ND REVIEW *** | | | | | | 1) NOTE: PLEASE SEE VALUE FOR COMPLETE SCOPE OF WORK | | | SHALL BE INCLUDE ON THIS APPLICATION ALL TRADE WORK IS | | | BEING SHOWN ON SAID PLANS FOR COMPLETE SCOPE OF WORK. | | | PLEASE KNOW, ONCE THE PERMIT ISSUED FOR THIS PERMIT | | | (UPON ADJUSTED VALUE) THE SUB CONTRACTORS WILL COME IN | | | WITH THEIR APPLICATIONS AND REFERENCE THESE PLANS FOR A | | | PERMIT. PLEASE KNOW THAT THE SUB CONTRACTOR WILL ONLY | | | PAY A $50 SUB PERMIT FEE AS THEY ARE REFERENCING PLANS | | | WHICH CONTAIN SCOPE OF WORK FOR ALL SUB TRADES. | | | ONLY WHEN THE SUB CONTRACTOR SUBMIT PLANS AND PERMIT | | | APPLICATION ON THEIR OWN DO THEY PAY FULL FEE BASED ON | | | THEIR SEPARATE SCOPE OF WORK. | | | PLEASE ADJUST TO INCLUDE ALL TRADES AS PLANS SUBMITTED | | | INDICATE. | | | PLEASE KNOW , ONE MAY BE ASSESSED USING THE MARSHAL'S & | | | SWIFT GUIDE AS ADOPTED BY THE CITY OF WEST PALM BEACH | | | 108.3 | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-09 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-09 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2006-09-09 00:00:00 | *** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE VALUE FOR COMPLETE | | | SCOPE OF WORK SHOWN ON PLANS IS LOW. | | | PLEASE SEE VALUE SHALL BE BASED ON ALL | | | LABOUR AND MATERIALS, "EVEN IF | | | MATERIALS, LT'S ETCIS OWNER SUPPLIED". | | | PLEASE KNOW VALUE SHOULD BE ADJUSTED OR | | | ONE BE WILL ADJUST USING THE MARSHALL'S | | | & SWIFT GUIDE AS ADOPTED BY THE FBC/ | | | FBC 108.3 ADMIN SECT. | | | | | | 2) NOTE: PLEASE SEE CODES RELEVANT TO | | | SCOPE OF WORK, DESIGNS ETC SHALL BE | | | SPECIFIED ON PLANS. | | | PLEASE SEE THE FOLLOWING SHALL BE | | | INDICATED ATA MINIMUM. | | | 2002 NFPA-70(NEC), 2002 NFPA-72, 2003 | | | NFPA-101 (LIFE SAFETY CODE). | | | PLEASE SEE ANY COMMENTS FROM OTHER | | | TRADES WHICH ALSO MAY REQUIRE SPECIFIC | | | CODES. | | | FBC 106.1.2 ADMIN SECT | | | | | | 3) NOTE: PLEASE SEE PLANS INDICATE "MEP" ENGINEERING | | | FIRM HOWEVER NONE OF THE MEP | | | SHEETS ARE SIGNED, DATED OR SEAL BY THE ENGINEER(S) AND | | | NO OTHER SHEETS CONTAIN | | | THE REQUIRED TITLE BLOCKS. | | | PLEASE VERIFY AS THE ARCHITECT SEEMS TO | | | BE SIGNING FOR ALL MEP, WORK WHICH IS | | | NOT PERMITTED. PLEASE SEE FS 481.221. | | | FS 471.025,471.023, FAC 61G15-23.002 | | | | | | 4) NOTE: PLEASE SEE PERMIT APPLICATION, | | | PLEASE SEE THE CONTRACTOR'S REP OR | | | QUALIFIER WHO SIGNED APPLICATION DID NOT | | | ALSO PRINT NAME AS NEEDED AND STATED ON APPLICATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-28 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-28 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2006-12-28 11:29:48 | *****PROVISO***** | | | | | | | | | 1.) STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241. | | | | | | 2.) ACCUMULATIONS OF COMBUSTIBLE WASTE | | | MATERIALS AND DUST DEBRIS SHALL BE | | | REMOVED FROM THE STRUCTURE AND ITS | | | VICINITY AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE | | | OPERATIONS. | | | | | | 3.) ALL EXIT COMPONENTS SHALL BE | | | MAINTAINED, CLEAR AND UNOBSTRUCTED. | | | | | | 4.) WHERE THE BUILDING IS PROTECTED BY | | | FIRE PROTECTION SYSTEMS, SUCH SYSTEMS | | | SHALL BE MAINTAINED OPERATIONAL AT ALL | | | TIMES DURING OPERATION. | | | | | | 5.) IF IT NECESSARY TO SHUT DOWN A FIRE | | | PROTECTION SYSTEM, WPB FIRE RESCUE SHALL | | | BE NOTIFIED WHEN THE SYSTEM IS SHUT DOWN | | | AND WHEN THE SYSTEM IS RETURNED TO | | | SERVICE. | | | | | | 6.) IF THE SCOPE OF THE INTERIOR | | | BUILDOUT REQUIRES MODIFICATIONOF THE | | | FIRE SPRINKLER AND/OR FIRE ALARM SYSTEM, | | | SEPARATE PERMIT AND SHOPDRAWING/PLAN IS | | | REQUIRED. | | | | | | 7.) PROVIDE EXISTING AND PROPOSED LIFE | | | SAFETY PLAN TO ILLUSTRATE SPRINKLER | | | HEADS, FIRE ALARM DETECTION DEVICES, | | | EXIT LIGHTS, EMERGENCY LIGHTS, FIRE | | | EXTINGUISHERS, ETC. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-09-19 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-09-19 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2006-09-19 00:00:00 | **PLEASE SUBMIT OR ADDRESS THE FOLLOWING | | | NOTES FOR REVIEW.** | | | | | | | | | 1.) NFPA 101,2003 EDITION TO BE | | | REFERENCED IN ADDITION TO FLORIDA FIRE | | | PREVENTION CODE, 2004 EDITION, AS | | | RECORDED IN YOUR PROJECT NOTES (SHEET | | | A-1). | | | | | | 2.) STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241. | | | | | | 3.) ACCUMULATIONS OF COMBUSTIBLE WASTE | | | MATERIALS AND DUST DEBRIS SHALL BE | | | REMOVED FROM THE STRUCTURE AND ITS | | | VICINITY AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE | | | OPERATIONS. | | | | | | 4.) ALL EXIT COMPONENTS SHALL BE | | | MAINTAINED, CLEAR AND UNOBSTRUCTED. | | | | | | 5.) WHERE THE BUILDING IS PROTECTED BY | | | FIRE PROTECTION SYSTEMS, SUCH SYSTEMS | | | SHALL BE MAINTAINED OPERATIONAL AT ALL | | | TIMES DURING OPERATION. | | | | | | 6.) IF IT NECESSARY TO SHUT DOWN A FIRE | | | PROTECTION SYSTEM, WPB FIRE RESCUE SHALL | | | BE NOTIFIED WHEN THE SYSTEM IS SHUT DOWN | | | AND WHEN THE SYSTEM IS RETURNED TO | | | SERVICE. | | | | | | 7.) IF THE SCOPE OF THE INTERIOR | | | BUILDOUT REQUIRES MODIFICATIONOF THE | | | FIRE SPRINKLER AND/OR FIRE ALARM SYSTEM, | | | SEPARATE PERMIT AND SHOPDRAWING/PLAN IS | | | REQUIRED. | | | | | | 8.) PROVIDE EXISTING AND PROPOSED LIFE | | | SAFETY PLAN TO ILLUSTRATE SPRINKLER | | | HEADS, FIRE ALARM DETECTION DEVICES, | | | EXIT LIGHTS, EMERGENCY LIGHTS, FIRE | | | EXTINGUISHERS, ETC. | | | | | | | | | | | | | | | LT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-27 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-27 |
Time |
08:16 |
Sent To |
E |
|
| Notes |
| 2007-02-27 08:17:22 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-12 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-12 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2006-11-14 10:31:34 | TO "COMM" BD#8 | | 2006-11-12 14:21:17 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-10-03 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-28 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | TO "COMM" BD#7 | | 2006-08-28 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-12-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-12-01 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-12-01 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-10-02 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-10-02 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | DENIED: | | | 1.PLAN SHEET M-1 INDICATES FLEX DUCT | | | PENETRATING THROUGH RATED PARTITIONS. | | | PER 2004 FMC 603.5.5, FLEXIBLE AIR DUCTS | | | & CONNECTORS SHALL NOT PASS THROUGH ANY | | | FIRE RESISTANCE RATED ASSEMBLY. | | | | | | 2.PLESE CLARIFY EXUST 10" X 7" EXHAUST | | | DUCT RISER CONNECTING TO NEW EF-1.IS | | | THIS A SHAFT INTO WHICH THE EF-1 | | | TERMIATES, PLEASE INDICATE IF THIS IS A | | | SUB-DUCT METHOD. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-06 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-06 |
Time |
18:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-08 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-08 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2006-09-08 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | CITY MUNICIPAL CODE | | | | | | 1. SHT A-1 BUILDING DEPARTMENT NOTES: | | | 1(C) TO READ FBC-2004 CHAPTER 11 | | | | | | 2. SHT A-5 DETAIL 7 SHOW COMPLIANCE WITH | | | SECTION 11-4.16.5 FLUSH CONTROLS. | | | | | | 3. SUBMIT A DETAIL FOR THE LAVS SHOWING | | | COMPLIANCE WITH SECTION 11-4.19 AND ALL | | | SUBSECTIONS. | | | | | | 4. SHOW THE CLEAR FLOOR SPACE FOR ALL | | | FIXTURES IN ACCESSIBLE BATHROOMS PER | | | SECTIONS 11-4.16.2, 11-4.19.3, AND | | | 11-4.21.2. | | | | | | 5. SECTION 11-4.2.3 THE BATHROOM DOORS | | | SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACE REQUIRED FOR ANY FIXTURE. | | | | | | 6. SHT A-7 DETAIL #2 SHOW COMPLIANCE | | | WITH THE FOLLOWING: | | | FOR WATER CLOSETS, | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.3 HEIGHT | | | C. 11-4.16.4 GRAB BARS | | | D. 11-4.16.5 FLUSH CONTROLS | | | E. 11-4.16.6 DISPENSERS | | | FOR LAVS, | | | A. 11-4.19.3 CLEAR FLOOR SPACE | | | B. 11-4.19.4 EXPOSED PIPES & SURFACES | | | C. 11-4.19.5 FAUCETS | | | | | | 7. SHT P-1 DETAILS 1 & 5. UNDERCOUNTER | | | GREASE TRAPS ARE NOT APPROVED IN THE | | | FOOD PREP AREA. MUNICIPAL CODE SECTION | | | 90-124(7)(B). - A MINIMUM 750 GALLON | | | GREASE INTERCEPTOR IS REQUIRED. | | | INTERCEPTOR SHALL BE SIZED BY LYNN | | | MASSON, ENVIRONMENTAL COMPLIANCE MANAGER | | | AND CAN BE CONTACTED BY PHONE. (561) | | | 822-2271, OR FAX (561) 822-2279, OR BY | | | E-MAIL [email protected]. WASTE ORD. 3434. | | | | | | 8. SHT P-1 ALL SINKS SHALL BE DRAINED BY | | | INDIRECT WASTE IN THE FOOD PREP AREA. | | | SECTION 802.1.1. | | | | | | 9. SHT P-2 PLUMBING PRODUCTS: NOTE #3, | | | 2-1/2" AND SMALLER PIPE SHALL BE SLOPED | | | 1/4"/FT MINIMUM. TABLE 704.1 | | | | | | 10. SHT P-2 PLUMBING GENERAL NOTES: #2 | | | REFERENCE CODE FBC-2004 PLUMBING. | | | | | | *************************************** | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|