| Plan Review Stops For Permit 06081940 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-03-01 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-03-01 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2007-03-01 13:17:06 | THE UNIT NUMBER IS CORRECT ON THE REVISED SITE PLANS | | | .477 S ROSEMARY AVE #169. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-09-12 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-09-12 |
Time |
13:36 |
Sent To |
I |
|
| Notes |
| 2006-09-12 00:00:00 | NO UNIT SPECIFIED ON THE APPLICATION | | | US EXT #0001 FOR THE UNIT 169 . | | 2006-09-09 00:00:00 | NEEDS, NEW SPACE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-08-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-17 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-17 |
Time |
17:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-08-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-17 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-17 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2007-08-17 10:29:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)I WAS UNABLE TO LOCATE THE APPLICATION IN THE | | | PACKAGE.PLEASE PROVIDE THE PERMIT APPLICATION SO THAT | | | THE PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-06 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-06 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2007-08-06 09:32:21 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)TYPE IIA DECLARED; THIS REQUIRES A 1 HOUR FOR | | | STRUCTURAL COLUMNS FBC TABLE 601.SEE SHEET D1, | | | REMOVAL OF DRYWALL AT THE STEEL COLUMNS.ARE THE | | | COLUMNS STRUCTURAL?HOW DOES THE REMOVAL OF DRYWALL | | | AFFECT THE REQUIRED FIRE RATING? | | | | | | NEW COMMENT 8/10/7 | | | | | | PLEASE RETAIN DBPR APPROVAL SHEETS IN THE PLAN. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2007-05-03 10:33:14 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER 561-805-6724 | | | [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | COMMENTS FROM PREVIOUS REVIEWS, NOT PROPERLY | | | ADDRESSED: | | | | | | | | | 1.)A1.0 SHOWS "EXISTING FIRE RATED | | | WALLS"; SPECIFY FIRE RATING. | | | | | | 3RD REVIEW ? A1.0 SHOWS A 4 HOUR WALL BETWEEN THE | | | PROPOSED RESTAURANT AND MACY?S, AND A 2 HOUR WALL AT | | | THE SHAFT.A1.1 SHOWS THE 4 HOUR WALL AS A 2 HOUR | | | WALL.PLEASE ADDRESS. | | | | | | 2.)IS THIS A CHANGE OF OCCUPANCY? | | | DECLARE GOVERNING CODE, FBC EB, AND | | | LEVEL OF ALTERATION FBC EB 3, AND CHANGE | | | OF OCCUPANCY IF APPLICABLE FBC 8. | | | | | | 3RD REVIEW ? THE ARCHITECT HAS DECLARED LEVEL 1 | | | ALTERATION.SEE FBC EB CHAPTER 3.DOESN?T THIS | | | INVOLVE ADDITION OF WINDOWS, RECONFIGURATION OF SPACE? | | | THIS DOES NOT APPEAR TO BE A LEVEL 1 ALTERATION. | | | | | | 3.)PROVIDE A FIRE SPRINKLER PLAN, FBC*106.3.5.1.1(5), | | | FS553.79(2). | | | | | | 3RD REVIEW ? THIS IS A STATUTORY REQUIREMENT; SEE | | | ATTACHED LETTER.A 4X PLAN REVIEW FEE HAS BEEN | | | CHARGED.THIS IS ALSO A STATUTORY REQUIREMENT; MUST BE | | | CHARGED WHEN THE SAME COMMENT IS NOT ADDRESSED THREE | | | TIMES AND IS REQUIRED TO BE CHARGED EACH TIME AFTER THE | | | THIRD TIME. | | | | | | 4.)FBC TABLE 1004.1.2, PLAN STATES MOVEABLE SEATS, | | | ARE THE TABLES FIXED?UNCONCENTRATED (TABLES & CHAIRS) | | | IS 15 NET. | | | | | | 3RD REVIEW; OCCUPANT LOAD CANNOT BE LESS THAN THE | | | TABLE, SO PLEASE ROUND UP RATHER THAN DOWN, INDOORS | | | LESS BOOTHS CALCULATION. | | | | | | 5.)3RD REVIEW, FIRE RESISTANCE REQUIREMENTS ARE STILL | | | NOT CLEAR.PLEASE SEE A1.1, DETAIL FOR UL U477, 2 HOUR | | | BEARING WALL.I WAS UNABLE TO LOCATE THIS ASSEMBLY IN | | | THE UL BOOK (HAS U476, U478, BUT NOT U477).THE | | | DRAWING SHOWS THAT THIS IS A 1 HOUR WALL (BUT THE UL | | | LISTING STATES IT IS A 2 HOUR) WITH 1 LAYER 5/8 TO | | | CREATE A NEW 2 HOUR WALL.SEE FBC TABLE 721.2.1.4(2), | | | 5/8 TYPE X HAS 40 MINUTE RATING, SO THIS WOULD NOT | | | CREATE A 2 HOUR WALL.IT IS NOT CLEAR WHERE THIS WILL | | | BE INSTALLED.SEE FBC TABLE 302.3.2, AND FBC302.3.2 | | | EXCEPTION.IT IS ACCEPTABLE TO EXCEED MINIMUM CODE | | | REQUIREMENTS, BUT DETAILS ARE TO CLEARLY SHOW CODE | | | COMPLIANCE AND ARE TO BE CONSISTENT. | | | | | | 6.)A1.1 HAS A DETAIL WHICH IS NOT LABELED WITH A | | | DETAIL MARKER NUMBER AND DOES NOT SPECIFY WHAT IT IS | | | FOR OR WHAT THE FIRE RESISTANCE RATING IS.IS THIS A | | | PART OF DETAIL 1?IT IS CLOUDED SEPARATELY. | | | | | | 7.)C1, ITEM 8, STATES TABLE 600 REQUIREMENTS. DECLARE | | | BUILDING TYPE A OR B AND SHOW REQUIREMENTS BASED ON | | | FBC2004, TABLE 601. | | | | | | 8.)PLEASE SIGN THE OWNER/AGENT LINE OF THE ENERGY | | | CALCS, FBC 13 103.1. | | | | | | 9.)PROVIDE PRODUCT APPROVALS FOR THE COMPONENTS AND | | | CLADDING.A1.0, WINDOW SCHEDULE NOTES WINDOW C AS | | | EXISTING, AND IT APPEARS THAT WINDOWS A AND B ARE NEW. | | | DOES THIS MEAN THAT ALL OF THE DOORS ARE NEW?IF NOT, | | | NOTE THE DOORS AS EXISTING.IF THEY ARE, PROVIDE | | | PRODUCT APPROVALS. | | | | | | 10.)DESIGNER OF RECORD IS TO REVIEW PRODUCT | | | APPROVALS, FBC*106.3.3. | | | | | | ONE SET OF THE ARCHITECTURAL DRAWINGS HAS BEEN | | | RETAINED. | | | | | | 6/07 - THE RETAINED SET WAS RETURNED TO THE PACKAGE | | | (NEEDED DBPR STAMP). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-02 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-02 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2007-03-02 07:44:14 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)FBC TABLE 1004.1.2, PLAN STATES MOVEABLE SEATS, | | | ARE THE TABLES FIXED?UNCONCENTRATED (TABLES & CHAIRS) | | | IS 15 NET. | | | | | | 2.)A1.0, LOBBY FOR LOFTS, STILL STATES "EXISTING FIRE | | | RATED WALLS TO REMAIN".SEE PREVIOUS LIST IN REGARDS | | | TO SPECIFYING FIRE RATING. | | | | | | 3.)SEE PREVIOUS LIST, FIRE SPRINKLER PLAN REQUIRED | | | FBC*106.3.5.1.1.(5), FS553.79(2). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-09-29 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-09-29 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2006-09-29 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A1.0 SHOWS "EXISTING FIRE RATED | | | WALLS"; SPECIFY FIRE RATING. | | | | | | 2.)IS THIS A CHANGE OF OCCUPANCY? | | | DECLARE GOVERNING CODE, FBC EB, AND | | | LEVEL OF ALTERATION FBC EB 3, AND CHANGE | | | OF OCCUPANCY IF APPLICABLE FBC 8. | | | | | | 3.)PROVIDE A FIRE SPRINKLER PLAN, | | | FBC*106.3.5.1.1(5). | | | | | | 4.)PROVIDE DIMENSIONS FOR THE HALLWAY | | | AND THE KITCHEN AREA (EGRESS, FBC 10). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-07-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-16 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-16 |
Time |
08:24 |
Sent To |
PC |
|
| Notes |
| 2008-07-16 08:25:39 | REV FOR SHEETS E0.1,E1 OK, HOWEVER SHEET E-0 WAS NOT | | | REVISED AND IS THE SAME SHEET ALREADY ON FILE. THIS | | | SHEET WAS NOT STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-05-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-06 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-06 |
Time |
11:54 |
Sent To |
PC |
|
| Notes |
| 2008-05-06 11:55:30 | ** DENIED REVISIONS/ OK REVISION** | | | | | | 1) NOTE: PLEASE SEE SHEET E-0 INDICATES A REVISION | | | HOWEVER THE PLANS DO NOT SEEM TO SHOW ANY REVISION #4. | | | THE OTHER REVISED ELECTRICAL SHEETS ARE OK AND | | | STAMPED. | | | PLEASE SUBMIT ANY REVISED SHEET E-0 | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-07 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-07 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2007-05-07 16:26:18 | NEW ENERGY CALCULATIONS SUBMITTED. | | | ELECTRICAL REVIEWED, OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-18 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-18 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2007-04-18 12:56:38 | ** UNSAT ** | | | | | | ** TEMPORARY FAILED STATUS | | | | | | | | | 1) NOTE: PLEASE SEE THE ENERGY CALCULATIONS CONTROL | | | METHODS NEED TO BE COORDINATED WITH THE ELECTRICAL | | | PLANS AND METHODS OF CONTROLS ON PLANS. | | | 13-415.1.A, 13-415.1.ABC.1.1. | | | A CALLED WAS PLACED TO THE ENGINEER OF RECORD FOR NEW | | | INPUT DATA REPORTS TO BE ADJUSTED AND SUBMITTED. | | | IF THERE ARE ANY QUESTIONS ON THIS AND HOW THESE ARE TO | | | BE SUBMITTED, PLEASE CONTACT THIS REVIEWER. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-24 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-22 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2007-01-24 12:38:41 | ***** UNSAT 2ND REVIEW ***** | | | | | | ITALIAN OVEN | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW WHICH IS | | | STILL IN NEED OF ADDRESSING. | | | PLEASE ALSO DO NOT SUBMIT LOOSE SHEETS NOT ATTACHED IN | | | THE SETS OF PLANS. PLEASE SUBMIT COMPLETE SETS SECURED | | | TOGETHER. | | | | | | 1) NOTE: OK. | | | | | | 2) NOTE: OK. | | | | | | 3) NOTE: NO, PLEASE SEE THE RESPONSE WAS TO ADD AND | | | ADDITIONAL SERVICE, HOWEVER AS THIS DOES NOT AT THIS | | | TIME FALL UNDER THE EXCEPTIONS FOR 230.2 THIS AHJ IS | | | NOT ABLE TO GRANT THE ADDITIONAL SERVICE BEING | | | PROPOSED. | | | PLEASE PROVIDE THE LOADS ON THE EXISTING SERVICE ALONG | | | WITH THE NEW LOADS. PLEASE KNOW THAT FURTHER | | | INFORMATION WOULD BE NEEDED FOR ANY OTHER | | | CONSIDERATION. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE PROVIDE LOADS ON EXISTING SERVICE GUTTER WITH | | | NEW LOADS BEING ADDED. PLEASE ALSO INDICATE THE SIZE OF | | | THE EXISTING SERVICE. | | | 230.2, 220, 215.5 ETC | | | FBC 106.1.2 ADMIN SECT. | | | | | | 4) NOTE: NO? THIS COMMENT IS CURRENTLY *UP IN THE AIR* | | | BASED ON THE FACT THAT THE SERVICE RISER HAS NOW | | | COMPLETELY CHANGED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING EQUIPMENT GROUNDING CONDUCTOR FROM | | | GUTTER TO METER, METER TO MAIN, MAIN TO SUB PANEL, | | | PANELS TO TRANSFORMERS, AND TRANSFORMER TO PANELS. ** | | | PLEASE KNOW, IF MAIN SERVICE FOR BUILDING CONTAINS AS | | | MAIN, THEN PROVIDE NOTE ON PLANS FOR "FLOATING NEUTRAL" | | | KIT REQUIRED IN METER. | | | 250.6, 250.24B, 250.110,250.6,250.122 ETC. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK, THE LOCATIONS ARE NOW BEING SHOWN, HOWEVER | | | THE MINIMUM CLEARANCES FOR WORKING CLEARANCE, | | | VENTILATION AND POSSIBLE STORAGE AREA THESE ARE BEING | | | SHOWN IS NOT CLEAR. | | | PLEASE SEEDISCONNECT AS SHOWN ON PLANS ALSO DOES NOT | | | MEET MINIMUM CLEARANCE REQUIREMENTS.PLEASE SEE 110.26 | | | AND THE SAME CODE SECTIONS AS PREVIOUSLY NOTED. | | | | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SHOW LOCATIONS OF TRANSFORMERS ON PLANS. PLEASE | | | SEE THAT A REVIEW FOR SOME CODE ITEMS CAN NOT BE DONE | | | AT THIS TIME AS THESE ARE NOT SHOWN. | | | PLEASE SEE INSTALLATION OF THE 112.5KVA TRANSFORMER | | | SHALL NOT BE ABOVE CEILING AND MUST MEET ALL THE | | | REQUIREMENTS AS | | | NEC ARTICLES BELOW REQUIRE. | | | PLEASE SEE 450.13B, 450.21, 450.9 ETC. | | | ** IF TRANSFORMER(S) ARE GOING TO BE MOUNTED FROM | | | CEILING OR WALL, PLEASE PROVIDE STRUCTURAL ENGINEERING | | | DETAILS FOR THIS. | | | | | | 7) NOTE: NO, PLEASE SEE THE TAPPED CONDUCTORS DO NOT | | | SEEM TO MEET THE CODE SECTION AS PREVIOUSLY GIVEN. | | | PLEASE SEE 240.21C6. PLEASE SEE THE DISTANCE ALONG WITH | | | THE SIZE OF THE CONDUCTOR TERMINATING INTO OVER CURRENT | | | PROTECTION WHICH LIMITS THE LOAD ON ANY CONDUCTOR IS | | | NOT MET AT THIS TIME. | | | PLEASE SEE THE RISER INDICATES 400AMP OCP ON | | | CONDUCTORS RATED AT 285AMPS. | | | | | | **PREVIOUS REVIEW NOTE** | | | PLEASE SEE 240.21 FOR TAPPED CONDUCTORS ON THE | | | SECONDARY SIDE OF TRANSFORMERS CAN NOT BE VERIFIED AT | | | THIS TIME. | | | | | | 8) NOTE: OK, SEE NOTE ABOVE #7. | | | | | | 9) NOTE: NO/OK, PLEASE SEE THIS WAS NOT DONE, HOWEVER | | | AS EQUIPMENT IS REMOVED FROM THE LIGHTING PLANS, IT | | | NEED ONLY BE SHOWN ON THE POWER PLANS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CORRELATE ALL PLANS FOR LOCATIONS OF ALL SERVICE | | | EQUIPMENT PANELS. PLEASE SEE PANELS ON LIGHTING SHEETS | | | ARE NOT IN THE SAME LOCATIONS AS PANELS ON POWER | | | SHEETS. | | | 106.1.2.FBC 110.26,240.24 ETC. | | | | | | 10) NOTE: OK. | | | | | | 11) NOTE: OK. | | | | | | 12) NOTE: OK. | | | | | | 13) NOTE: OK. | | | | | | 14) NOTE:NO, PLEASE SEE MOST WERE DONE, HOWEVER | | | PLEASE SEE PLANS AS THERE ARE SOME FIXTURES BEING | | | CIRCUITED TO CIRCUITS WHICH ARE SHOWN AS *BLANK* IN | | | PANEL SCHEDULE. PLEASE SEE REDLINED PLANS AND PLEASE | | | SEE NEW COMMENTS BASED ON COORDINATION OF CIRCUITING ON | | | PLANS, PANEL SCHEDULE, ETC. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 700.12E FOR CIRCUITING OF EMERGENCY AND EXIT | | | LTS. | | | THE BRANCH CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL BE | | | THE SAME BRANCH CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD OF ANY LOCAL | | | SWITCHES. | | | | | | 15) NOTE:OK, HOWEVER PLEASE SEE THERMOSTATICALLY | | | CONTROLLED DEVICES ARE NOW BEING SHOWN AT 125%? THIS IS | | | OK AND IS ONLY BEING NOTED AS NOT REQUIRED. THE | | | PREVIOUS NOTE IS BEING LEFT AS THE NOTE MENTIONS THIS | | | WAS EXEMPT. PLEASE ALSO SEE NOTE AS THE LOADS WILL BE | | | CONSIDERED FOR THE EXISTING MAIN SERVICE WHICH IS BEING | | | CONNECTED TO. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PANEL SCHEDULES ARE NOT COMPLETE WITH LOAD | | | CALCULATIONS AT THIS TIME. PLEASE PROVIDE COMPLETE LOAD | | | CALCULATIONS ON HOW LOADS WERE DERIVED. | | | PLEASE SEE 220.3,220.10,220.11,220.13 ETC | | | PLEASE ALSO INDICATE AND SHOW ALL CONTINUOUS LOADS (3OR | | | MORE HRS) AT 125%. (THERMOSTATICALLY CONTROLLED | | | UNITS/APPLIANCES ARE IN EXCEPTION) | | | | | | 16) NOTE: OK. | | | | | | 17) NOTE: OK. | | | | | | | | | 18) NOTE: OK, THESE ARE BEING ADDED, HOWEVER PLEASE | | | CLARIFY HOW LOAD WAS DERIVED. *EXAMPLE* X AMOUNT OF | | | LINEAR FT OF WINDOW AT 200VA PER FT = Y* | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE VERIFY NEW OR EXISTING SHOW/STOREFRONT WINDOW | | | RECEPTS REQUIRED ABOVE WINDOWS.210.62 | | | THESE WILL BE REQUIRED IF NOT EXISTING. | | | PLEASE ALSO SEE 220.12 FOR LOADS TO BE ADJUSTED. | | | | | | 19) NOTE: OK. | | | | | | 20) NOTE: OK. | | | | | | 21) NOTE:NO, | | | A) PLEASE SEE THE LIGHTING CONTROL PANEL DOES NOT | | | CONTAIN ANY TIME OF DAY SCHEDULING. (EXAMPLE: 8AM | | | -11PM). | | | B) PLEASE SEE THE CIRCUITING ON PLANS DOES NOT | | | CORRELATE WITH THE CIRCUITING ON PLANS OR PANEL | | | SCHEDULE(S). | | | C) PLEASE SEE THE METHOD *A* FOR LIGHTING CAN NOT BE | | | VERIFIED AT THIS TIME. PLEASE SEE THAT THE ENERGY | | | CALCULATIONS SUBMITTED DO NOT CORRELATE WITH THE | | | LIGHTING ON PLANS OR LOADS SHOWN ON PLANS FOR LIGHTING. | | | PLEASE CORRELATE. | | | D) PLEASE SEE BATHROOMS AS THE COVERAGE OF THE DEVICE | | | AS SHOWN WOULD NOT COVER THE OTHER CLOSED IN | | | AREAS/STALLS OF RESTROOM AREAS. PLEASE SEE THE TYPE OF | | | DEVICE MAY BE SPECIFIED WHICH MAY HELP IN COVERAGE; | | | HOWEVER DEPENDING ON DEVICE, COVERAGE, WALLS/PARTITIONS | | | ETC THESE WILL ALL HAVE AN AFFECT ON THE DESIGN FOR | | | LIFE SAFETY OF THESE LIGHTS. | | | ** THE INTENT IS NOT TO LEAVE AN OCCUPANT IN ANY AREA | | | IN TOTAL DARKNESS IN THE EVENT OF THE FAILURE OR | | | TURNING OFF OF THIS ONE DEVICE. | | | PLEASE SEE NEW COMMENT BASED ON THE TYPE OF EMERGENCY | | | FIXTURE BEING PLACED IN BATHROOM. | | | | | | ** PLEASE SEE THE PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THIS IS A NEW OCCUPANCY FOR SPACE. PLEASE | | | SEE 2004 FBC CHAPTER 13 FOR COMPLIANCE WITH THE NEW | | | FLORIDA ENERGY CODE. | | | PLEASE SEE 13-415.1.ABC.1.1, 13-415.1.ABC.1.2, AND | | | 13-415.1.ABC.1.3 | | | PLEASE PROVIDE A COMPLETE LIGHTING CONTROL SYSTEM AS | | | REQUIRED INCLUDING CONTROLS AND DEVICES FOR ALL | | | SEPARATE SPACES CONTAIN FLR TO CEILING HEIGHT | | | PARTITIONS. | | | PLEASE PROVIDE THE SCHEDULING; PLEASE PROVIDE TYPE OF | | | OVER RIDE DEVICES, ALONG WITH THE MAX TIME OVER RIDE AS | | | DETERMINED BY THE DEVICE. ( TIMER TYPE4HRS MAX, | | | MOTION/OCCUPANT SENSOR TYPE 30MINS MAX). | | | PLEASE SEE CONTROLS FOR OVER-RIDING SYSTEM SHALL ALSO | | | BE LOCATED AT THE POINTS OF ENTRANCE INTO SPACE. PLEASE | | | SEE THAT ANY OVER-RIDES MUST ALSO BE LOCATED SO THE | | | OCCUPANT CAN VISUALLY SEE THE LIGHTING BEING | | | CONTROLLED. | | | PLEASE SUBMIT LIGHTING POWER DENSITIES AS REQUIREDPER | | | 13-415.1.AB.1, | | | 13-415.2.ABC.1, AND TABLES 415.2.C.1, | | | 415.2.B.1, 13-415.2.B.1 ETC ETC. | | | PLEASE PROVIDE THE MAX ALLOWED COMPARED TO THE ACTUAL | | | DESIGN. | | | PLEASE SEE METHODS FOR NEW ENERGY CALCULATIONS MUST | | | ALSO BE SUBMITTED. | | | | | | 22) NOTE: OK. | | | | | | 23) NOTE: OK. | | | | | | ** NEW NOTES ** | | | | | | 1) NOTE: PLEASE SEE THE LIGHTING FIXTURE SCHEDULE. | | | PLEASE SOME FIXTURES WHICH ARE BEING SHOWN AS | | | EMERGENCY, HOWEVER THEY DO NOT CONTAIN ANY BATTERY BACK | | | UP. PLEASE SEE THE BATHROOMS ARE ONE LOCATION AS NOTED | | | ABOVE WHERE AN EMERGENCY BATTERY BACK UP LIGHT FIXTURE | | | OF SOME SORT IS REQUIRED. | | | NFPA-101 7.8, 7.9. | | | 700.12 E, 700.16 NEC. | | | | | | 2) NOTE:PLEASE SEE ARCHITECTURAL COVER SHEET MENTIONS | | | THIS AS LEVEL 2 ALTERATION FROM THE EXISTING 2004 FBC. | | | THIS IS NOT POSSIBLE FOR A CHANGE IN OCCUPANCY OR THE | | | SCOPE OF WORK IN THIS PROJECT. PLEASE ALSO SEE BUIDLING | | | REVIEW COMMENTS FOR THIS. | | | | | | 3) NOTE: PLEASE SEE FS 553.80(2)(B) WHICH IS BEING | | | GIVEN AS A NOTICE ONLY AT THIS TIME. | | | | | | ** PLEASE KNOW, AS THERE ARE ITEMS NOT | | | YET SUBMITTED FOR REVIEW, THERE MAY BE | | | NEW COMMENTS UPON NEXT REVIEW. | | | | | | ** PLEASE SEE POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL PLANS/DESIGN. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-01-22 18:12:46 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-09 |
Time |
21:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-09 |
Time |
19:18 |
Sent To |
|
|
| Notes |
| 2006-09-09 00:00:00 | ***** UNSAT ***** | | | | | | ITALIAN OVEN | | | | | | 1) NOTE: PLEASE SEE THE FOLLOWING CODES | | | ARE REQUIRED ON PLANS WHICH ARE RELEVANT | | | TO THE SCOPE OF WORK AND DESIGNS ON | | | PLANS. | | | 2004 FBC, 2002 NFPA-70 (NEC), 2002 | | | NFPA-72. 2004 NFPA-96, 2003 NFPA-101. | | | THESE ARE REQUIRED AT A MIN. | | | | | | 2) NOTE: PLEASE SEE ADDRESS OF SUITE | | | SHALL BE INDICATED ON TITLE BLOCKS ARE | | | REQUIRED UNDER THE FLORIDA | | | ADMINISTRATIVE CODE. | | | 61G1-16.004 AND 61G15-23.002 | | | PLEASE BE SURE TO ALSO CORRELATE WITH | | | THE PERMIT APPLICATION AS NO SUITE | | | NUMBER IS SHOWN. | | | | | | 3) NOTE: PLEASE PROVIDE LOADS ON | | | EXISTING SERVICE GUTTER WITH NEW LOADS | | | BEING ADDED. PLEASE ALSO INDICATE THE | | | SIZE OF THE EXISTING SERVICE. | | | 230.2, 220, 215.5 ETC | | | FBC 106.1.2 ADMIN SECT. | | | | | | 4) NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM GUTTER TO | | | METER, METER TO MAIN, MAIN TO SUB PANEL, | | | PANELS TO TRANSFORMERS, AND TRANSFORMER | | | TO PANELS. | | | ** PLEASE KNOW, IF MAIN SERVICE FOR | | | BUILDING CONTAINS AS MAIN , THEN PROVIDE | | | NOTE ON PLANSFOR "FLOATING NEUTRAL" | | | KIT REQUIRED IN METER. | | | 250.6,250.24B, 250.110,250.6,250.122 | | | ETC. | | | | | | 5) NOTE: PLEASE SHOW AND INDICATE THE | | | GROUNDING ATTACHMENT LOCATIONS FOR NEW | | | AND EXISTING TRANSFORMERS. | | | PLEASE SEE 250.30,250.20,250.66, 250.58, | | | 250.50 | | | | | | 6) NOTE: PLEASE SHOW LOCATIONS OF | | | TRANSFORMERS ON PLANS. PLEASE SEE THAT A | | | REVIEW FOR SOME CODE ITEMS CAN NOT BE | | | DONE AT THIS TIME AS THESE ARE NOT | | | SHOWN. | | | PLEASE SEE INSTALLATION OF THE 112.5KVA TRANSFORMER | | | SHALL NOT BE ABOVE CEILING | | | AND MUST MEET ALL THE REQUIREMENTS AS | | | NEC ARTICLES BELOW REQUIRE. | | | PLEASE SEE 450.13B, 450.21, 450.9 ETC. | | | ** IF TRANSFORMER(S) ARE GOING TO BE | | | MOUNTED FROM CEILING OR WALL, PLEASE | | | PROVIDE STRUCTURAL ENGINEERING DETAILS | | | FOR THIS. | | | | | | 7) NOTE: PLEASE SEE 240.21 FOR TAPPED | | | CONDUCTORS ON THE SECONDARY SIDE OF | | | TRANSFORMERS CAN NOT BE VERIFIED AT THIS | | | TIME. | | | | | | 8) NOTE: PLEASE SEE PANEL LPH AND LP/LP | | | SHOULD BE SHOWN AS 400A RATED AND | | | CONTAINING A 300A BRKR IF THIS IS GOING | | | TO BE THE DESIGN. PLEASE SEE PANEL NOW | | | SHOWS A 400A BRKR WITH A 300A TRIP? | | | IF THIS TYPE OF BRKR IS GOING TOBE | | | INSTALLED, PLEASE SUBMIT MANUFACTURES | | | CUT/SPEC SHEETS ON THIS BREAKER, MUST | | | INDICATE A LISTING FROM A NRTL. | | | 110.3,90.7. | | | | | | 9) NOTE: PLEASE CORRELATE ALL PLANS FOR | | | LOCATIONS OF ALL SERVICE EQUIPMENT | | | PANELS. PLEASE SEE PANELS ON LIGHTING | | | SHEETS ARE NOT IN THE SAME LOCATIONS AS | | | PANELS ON POWER SHEETS. | | | 106.1.2.FBC | | | 110.26,240.24 ETC. | | | | | | 10) NOTE: PLEASE CORRELATE RISER AND | | | PANELS FOR FEEDER SIZES. | | | 310.16 , 240.4 | | | PLEASE SEE NEW TRANSFORMER SHOWS 2/0'S | | | ON PANEL AND RISER SHOWS 1/0'S. PLEASE | | | SEE 310.16 AS THE 1/0'S AS SHOWN ARE | | | NOTE RATED FOR OCP BEING PROVIDED. | | | | | | 11) NOTE: PLEASE SEE 240.6 FOR SIZING OF | | | STANDARDOCP DEVICES. PLEASE SEE 170A | | | BRKR BEING SHOWN FOR THE NEW TRANSFORMER | | | WHICH DOES NOT CORRELATE TO ANY OF THE | | | STANDARDS. | | | 240.4, 310.16, 240.6, 450.3 | | | | | | 12) NOTE: PLEASE CORRELATE RISER AND | | | PANEL SCHEDULES FOR LABELING OF PANELS. | | | ( TWO LP1'S) | | | FBC 106.1.2 | | | | | | 13) NOTE: PLEASE INDICATE THE NEW OR | | | EXISTING SIGN CIRCUIT(S). AS REQUIRED | | | PER 600.5 PLEASE SEE THAT EACH | | | COMMERCIAL BUILDING AND EACH COMMERCIAL | | | OCCUPANCY ACCESSIBLE TO PEDESTRIANS | | | SHALL BE PROVIDED WITH AT LEAST ONE | | | OUTLET IN AN ACCESSIBLE LOCATION AT EACH | | | ENTRANCE TO EACH TENANT SPACE FOR SIGN | | | OR OUTLINE LIGHTING SYSTEM USE. THE | | | OUTLET(S) SHALL BE SUPPLIED BY A BRANCH | | | CIRCUIT RATED AT LEAST 20 AMPERES THAT | | | SUPPLIES NO OTHER LOAD. | | | | | | 14) NOTE: PLEASE SEE 700.12E FOR | | | CIRCUITING OF EMERGENCY AND EXIT LTS. | | | THE BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | 15) NOTE: PLEASE SEE PANEL SCHEDULES ARE | | | NOT COMPLETE WITH LOAD CALCULATIONS AT | | | THIS TIME. PLEASE PROVIDE COMPLETE LOAD CALCULATIONS ON | | | HOW LOADS WERE DERIVED. | | | PLEASE SEE 220.3,220.10,220.11,220.13 | | | ETC | | | PLEASE ALSO INDICATE AND SHOW ALL | | | CONTINUOUS LOADS (3OR MORE HRS) AT 125%. | | | (THERMOSTATICALLY CONTROLLED | | | UNITS/APPLIANCES ARE IN EXCEPTION) | | | | | | 16) NOTE: PLEASE SEE TRANSFORMER ARE | | | BEING SHOWN WITH WHAT APPEARS TO BE | | | "NEUTRALS" IN THE FEEDER CONDUITS GOING | | | TO THE TRANSFORMERS? PLEASE KNOW, AS THE TRANSFORMERS | | | ARE CONSIDERED SEPARATELY | | | DERIVED SYSTEMS/SERVICES, A NEUTRAL | | | CONDUCTOR IS NOT INSTALLED. | | | PLEASE KEEP IN MIND THE PREVIOUS COMMENT | | | ABOVE WHICH PREVIOUSLY MENTIONED MISSING | | | EQUIPMENT GROUNDING CONDUCTORS. | | | | | | 17) NOTE: PLEASE SEE2002 NEC, 210.8B3 | | | WHICH REQUIRES ALL 15- AND 20-AMPERE, | | | 125-VOLT RECEPTACLES IN NONDWELLING-TYPE | | | KITCHENS TO BE GFCI PROTECTED. THIS | | | REQUIREMENT APPLIES TO EACH AND EVERY | | | 15- AND 20-AMPERE, 125-VOLT KITCHEN | | | RECEPTACLE, WHETHER OR NOT THE | | | RECEPTACLE SERVES COUNTERTOP APPLIANCES. | | | | | | | | | 18) NOTE: PLEASE VERIFY NEW OR EXISTING SHOW/STOREFRONT | | | WINDOW RECEPTS REQUIRED | | | ABOVE WINDOWS.210.62 | | | THESE WILL BE REQUIRED IF NOT EXISTING. | | | PLEASE ALSO SEE 220.12 FOR LOADS TO BE | | | ADJUSTED. | | | | | | 19) NOTE: PLEASE SEE COLOR CODING FOR | | | 120/240V SYSTEM WIRING IS BEING SHOWN ON | | | E-0, HOWEVER PLEASE SEE SYSTEM VOLTAGES | | | ON PLANS ARE 120/208 AND 277/480V. | | | PLEASE SEE COLOR CODING SHALL BE AS | | | FOLLOWS. | | | 120/208, | | | BLACK ,RED, BLUE | | | & | | | 277/480V | | | BROWN, PURPLE , YELLOW. | | | PLEASE KNOW, "ORANGE" IS ONLY IDENTIFIED | | | IN THE NEC FOR THE HIGH-LEG OF A OPEN | | | DELTA SYSTEM, 120/240V. | | | PLEASE ADJUST, 90.4 | | | ** ALL EXISTING SYSTEMS AT THIS LOCATION | | | AT CITY PLACE AND THIS JURISDICATION ARE | | | COLOR CODED THIS WAY. | | | | | | 20) NOTE: PLEASE SEE MISSING SHUNT TRIP IDENTIFICATIONS | | | FOR ALL ELECTRICAL | | | FEEDING OR UNDER HOOD. LTS ETC). | | | PLEASE SEE NFPA 2004/1998 BOTH ARE THE | | | SAME FOR REQUIRED AUTOMATIC SHUNT UPON | | | ACTIVATION OF ANY SURPRESSION SYSTEM. | | | | | | 21) NOTE: PLEASE SEE THIS IS A NEW | | | OCCUPANCY FOR SPACE. PLEASE SEE 2004 FBC | | | CHAPTER 13 FOR COMPLIANCE WITH THE NEW | | | FLORIDA ENERGY CODE. | | | PLEASE SEE 13-415.1.ABC.1.1, | | | 13-415.1.ABC.1.2, AND 13-415.1.ABC.1.3 | | | PLEASE PROVIDE A COMPLETE LIGHTING | | | CONTROL SYSTEM AS REQUIRED INCLUDING | | | CONTROLS AND DEVICES FOR ALL SEPARATE | | | SPACES CONTAIN FLR TO CEILING HEIGHT | | | PARTITIONS. | | | PLEASE PROVIDE THE SCHEDULING, PLEASE | | | PROVIDE TYPE OF OVER RIDE DEVICES, ALONG | | | WITH THE NAX TIME OVE OVER RIDE AS | | | DETERMINED BY THE DEVICE. ( TIMER TYPE | | | 4HRS MAX, MOTION/OCCUPANT SENSOR TYPE | | | 30MINS MAX). | | | PLEASE SEE CONTROLS FOR OVER-RIDING | | | SYSTEM SHALL ALSO BE LOCATED AT THE | | | POINTS OF ENTRANCE INTO SPACE. PLEASE | | | SEE THAT ANY OVER-RIDES MUST ALSO BE | | | LOCATED SO THE OCCUPANT CAN VISUALLY SEE | | | THE LIGTHING BEING CONTROLLED. | | | PLEASE SUBMIT LIGHTING POWER DENSITES AS | | | REQUIREDPER 13-415.1.AB.1, | | | 13-415.2.ABC.1, AND TABLES 415.2.C.1, | | | 415.2.B.1., 13-415.2.B.1 ETC ETC. | | | PLEASE PROVIDE THE MAX ALLOWED COMPARED | | | TO THE ACTUAL DESIGN. | | | PLEASE SEE METHODS FOR NEW ENERGY | | | CALCULATIONS MUST ALSO BE SUBMITTED. | | | | | | 22) NOTE: PLEASE INDICATE IF "LP" | | | CONTAINS FEED-THRU LUGS OR IS THERE OCP | | | IN LP FEEDING 2ND SECTION OF LP. | | | | | | 23) NOTE: PLEASE SEE 220.12,AN | | | ADDITIONAL LOAD OF 150 VOLT-AMPERES | | | SHALL BE INCLUDED FOR EVERY 600 MM (2 | | | FT) OF LIGHTING TRACK OR FRACTION | | | THEREOF. | | | | | | ** PLEASE KNOW, AS THERE ARE ITEMS NOT | | | YET SUBMITTED FOR REVIEW, THERE MAY BE | | | NEW COMMENTS UPON NEXT REVIEW. | | | | | | ** PLEASE SEE POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL PLANS/DESIGN. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-14 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-14 |
Time |
17:09 |
Sent To |
B1 |
|
| Notes |
| 2007-08-14 17:30:55 | ***PROVISO***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;PLAN SHEET(S) A1.0, A2.0, AND E-2 WERE | | | STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 8561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-07 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-07 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2007-05-07 13:27:47 | ***DENIED***** | | | | | | THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEWS STILL NEED TO BE ADDRESSED: | | | | | | | | | 01.)NFPA 101, 2003 EDITION AND FLORIDA FIRE | | | PREVENTION CODE , 2004 EDITION SHALL BE REFERENCED. | | | | | | 02.)STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, | | | AND DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.)ACCUMULATIONS OF COMBUSTIBLE WASTE AND DUST | | | DEBRIS SHALL BE REMOVED FROM THE STRUCTURE AND ITS | | | IMMEDIATE VICINITY AT THE END OF EACH SHIFT OR MORE | | | FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. | | | | | | 04.)CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | | NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | | PROPERTY OR VICINITY THEREOF (INCLUDING FIRE LANES). | | | | | | 06.)WHERE THE BUILDING IS PROTECTED BY FIRE | | | PROTECTION SYSTEMS, SUCH SYSTEMS SHALL BE MAINTAINED | | | OPERATIONAL AT ALL TIMES DURING ALTERATION. | | | | | | 07.)IF THE SCOPE OF THE INTERIOR BUILDOUT REQUIRES | | | MODIFICATION OF THE FIRE SPRINKLER OR FIRE ALARM | | | SYSTEM, SEPARATE PERMIT AND PLANS ARE TO BE SUBMITTED | | | FOR REVIEW. | | | | | | 08.PLEASE SHOW THE LOCATION OF THE 2A:10BC FIRE | | | EXTINGUISHERS SATISFYING THE 75' TRAVEL DISTANCE. | | | | | | 09.)ADDITIONAL PERMIT AND PLANS REQUIRED FOR | | | MECHANICAL HOOD/SUPPRESSION SYSTEM. | | | | | | 10.)DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL | | | FIRE ALARM. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 8561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-20 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-20 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2007-02-20 17:16:13 | ***DENIED***** | | | | | | NOTICE:WITH THE EXCEPTION OF COMMENT # 00,ALL | | | OTHER COMMENTS WERE THOSE OF THE PREVIOUS FIRE PLAN | | | REVIEW OF 10/12/2006 | | | | | | | | | 00.)THE COMPLETE ADDRESS OF WHERE THE SCOPE OF THE | | | WORK IS TO BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF | | | EACH SUBMITTED PLAN SHEET. | | | | | | 01.)NFPA 101, 2003 EDITION AND FLORIDA FIRE | | | PREVENTION CODE , 2004 EDITION SHALL BE REFERENCED. | | | | | | 02.)STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, | | | AND DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.)ACCUMULATIONS OF COMBUSTIBLE WASTE AND DUST | | | DEBRIS SHALL BE REMOVED FROM THE STRUCTURE AND ITS | | | IMMEDIATE VICINITY AT THE END OF EACH SHIFT OR MORE | | | FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. | | | | | | 04.)CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | | NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | | PROPERTY OR VICINITY THEREOF (INCLUDING FIRE LANES). | | | | | | 05.)ON THE APPROPIATE STOREFRONT AND (OR) ELEVATION | | | SHEET, SHOW/DISPLAY THE TENANT SPACE NUMBER FOR THIS | | | STRUCTURE.AS PER WEST PALM BEACH CODE, THE CHARACTERS | | | (NUMBERS AND/OR LETTERS) SHALL BE NO LESS THAN 3" IN | | | HEIGHT AND 1" IN WIDTH.IF SO EQUIPPED, HURRICANE | | | SHUTTERS SHALL NOT COVER OR CONCEAL THE ADDRESS. | | | | | | 06.)WHERE THE BUILDING IS PROTECTED BY FIRE | | | PROTECTION SYSTEMS, SUCH SYSTEMS SHALL BE MAINTAINED | | | OPERATIONAL AT ALL TIMES DURING ALTERATION. | | | | | | 07.)IF THE SCOPE OF THE INTERIOR BUILDOUT REQUIRES | | | MODIFICATION OF THE FIRE SPRINKLER OR FIRE ALARM | | | SYSTEM, SEPARATE PERMIT AND PLANS ARE TO BE SUBMITTED | | | FOR REVIEW. | | | | | | 08.)PLEASE INDICATE/DISPLAY/SHOW THE LOCATION OF EXIT | | | LIGHTS, EMERGENCY LIGHTS, FIRE EXTINGUISHERS, AND FIRE | | | PROTECTION SYSTEM(S).HOW WILL THEY BE AFFECTED BY THE | | | SCOPE OF WORK? | | | | | | 09.)ADDITIONAL PERMIT AND PLANS REQUIRED FOR | | | MECHANICAL HOOD/SUPPRESSION SYSTEM. | | | | | | 10.)DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL | | | FIRE ALARM. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 8561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-12 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-12 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2006-10-12 13:08:25 | *****UNSAT***** | | | | | | | | | | | | | | | 01.)NFPA 101, 2003 EDITION AND FLORIDA FIRE | | | PREVENTION CODE , 2004 EDITION SHALL BE REFERENCED. | | | | | | 02.)STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, | | | AND DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.)ACCUMULATIONS OF COMBUSTIBLE WASTE AND DUST | | | DEBRIS SHALL BE REMOVED FROM THE STRUCTURE AND ITS | | | IMMEDIATE VICINITY AT THE END OF EACH SHIFT OR MORE | | | FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. | | | | | | 04.)CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | | NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | | PROPERTY OR VICINITY THEREOF (INCLUDING FIRE LANES). | | | | | | 05.)ON THE APPROPIATE STOREFRONT AND (OR) ELEVATION | | | SHEET, SHOW/DISPLAY THE NUMERICAL ADDRESS ON THE | | | STRUCTURE.AS PER WEST PALM BEACH CODE, THE CHARACTERS | | | (NUMBERS AND/OR LETTERS) SHALL BE NO LESS THAN 6" IN | | | HEIGHT AND 1" IN WIDTH.IF SO EQUIPPED, HURRICANE | | | SHUTTERS SHALL NOT COVER OR CONCEAL THE ADDRESS. | | | | | | 06.)WHERE THE BUILDING IS PROTECTED BY FIRE | | | PROTECTION SYSTEMS, SUCH SYSTEMS SHALL BE MAINTAINED | | | OPERATIONAL AT ALL TIMES DURING ALTERATION. | | | | | | 07.)IF THE SCOPE OF THE INTERIOR BUILDOUT REQUIRES | | | MODIFICATION OF THE FIRE SPRINKLER OR FIRE ALARM | | | SYSTEM, SEPARATE PERMIT AND PLANS ARE TO BE SUBMITTED | | | FOR REVIEW. | | | | | | 08.)PLEASE INDICATE/DISPLAY/SHOW THE LOCATION OF EXIT | | | LIGHTS, EMERGENCY LIGHTS, FIRE EXTINGUISHERS, AND FIRE | | | PROTECTION SYSTEM(S).HOW WILL THEY BE AFFECTED BY THE | | | SCOPE OF WORK? | | | | | | 09.)ADDITIONAL PERMIT AND PLANS REQUIRED FOR | | | MECHANICAL HOOD/SUPPRESSION SYSTEM. | | | | | | 10.)DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL | | | FIRE ALARM. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 8561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-12 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-12 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-08 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-08 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2006-09-08 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SHT P-3 THE FOLLOWING INFORMATION IS | | | REQUIRED FOR REQUIRED GAS PERMIT: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. LENGTHS NOT SHOWN. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | E. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | F. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | G. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. UNION NOT | | | SHOWN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-06 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-06 |
Time |
10:46 |
Sent To |
P |
|
| Notes |
| 2008-08-06 10:46:30 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-16 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-16 |
Time |
16:20 |
Sent To |
P |
|
| Notes |
| 2008-06-16 16:20:32 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-11 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-11 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2008-06-11 15:46:53 | TO "COMM" BD#55 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-06-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-10 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-10 |
Time |
14:44 |
Sent To |
P |
|
| Notes |
| 2008-06-10 14:44:46 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-02 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-02 |
Time |
12:47 |
Sent To |
P |
|
| Notes |
| 2008-05-02 12:47:44 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-02 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-02 |
Time |
12:35 |
Sent To |
M |
|
| Notes |
| 2008-05-02 12:35:54 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-02 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-02 |
Time |
12:00 |
Sent To |
E |
|
| Notes |
| 2008-05-02 12:00:37 | TO "DPALMER' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2008-01-02 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2008-01-02 |
Time |
16:06 |
Sent To |
B |
|
| Notes |
| 2008-01-02 16:06:44 | TO SAMANTHA HILLS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2007-08-01 08:15:41 | TO "COMM" BD#5 | | 2007-07-30 09:32:35 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-18 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-18 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2007-04-18 09:06:42 | TO "COMM" BD#60 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-10 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-10 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2007-01-22 08:40:12 | TO "COMM" BD#13 | | 2007-01-10 10:11:16 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-12 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-08-25 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | WAITING FOR "COMM" BD | | | TO "COMM" BD#58 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-07-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-02 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-02 |
Time |
15:24 |
Sent To |
E |
|
| Notes |
| 2008-07-02 16:53:48 | REVISED M-1, M-2, M-3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-21 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-21 |
Time |
08:55 |
Sent To |
PC |
|
| Notes |
| 2008-05-21 11:13:12 | REVIEW #: REVISION | | | ACTION: DENIED | | | | | | CODES: | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PAGES M-0, M-3 AND M-4 WERE SUBMITTED AS PART OF | | | THIS REVISION BUT DO NOT SHOW ANY CHANGES. WHEN | | | RESUBMITTING, PLEASE PROVIDE ONLY THOSE PAGES WHICH | | | HAVE CHANGES TO BE UPDATED IN THE PERMIT RECORD. | | | | | | 2. PG M-2: HOOD-3 IS BEING REMOVED FROM PLANS. IF THERE | | | IS AN OVEN AT THIS LOCATION, IT STILL REQUIRES EITHER A | | | TYPE I OR TYPE II HOOD IN ACCORDANCE WITH FBCM 507.2. | | | PLEASE SHOW HOW COMPLIANCE WITH THIS CODE SECTION SHALL | | | BE ACHIEVED. | | | | | | 3. PG M-2: THE 10X10 GREASE DUCT ASSOCIATED WITH HOOD-3 | | | IS BEING REPLACED WITH AN 8 INCH ROUND DUCT. KEY NOTE | | | #4 CALLS THIS A GREASE DUCT WHILE KEY NOTE #39 CALLS IT | | | A PRE-FAB DIRECT-VENT EXHAUST DUCT. PLEASE CLARIFY BY | | | ELIMINATING CONFLICTING INFORMATION IN THE KEY NOTES. | | | ALSO, IF THE OVEN IS A DIRCT-VENT APPLIANCE AS | | | INDICATED BY KEY NOTE #19, IT REQUIRES COMBUSTION AIR | | | DIRECTLY FROM THE OUTDOORS. SEE DEFINITION OF | | | DIRECT-VENT IN FBCFG SECTION 202. SHOW THE SOURCE OF | | | DIRECT COMBUSTION AIR IF THIS IS A DIRECT-VENT | | | APPLIANCE. | | | | | | 4. PG M-2: KEY NOTE #4 INDICATES THE 8 INCH ROUND DUCT | | | IN THE SHAFT IS EXISTING. THIS IS NOT ACCURATE AS THE | | | EXHAUST DUCTS IN THE SHAFT WERE INSTALLED UNDER | | | SEPARATE PERMIT #07010023 AND THERE WAS NO 8 INCH ROUND | | | DUCT ON PLANS OR ASSOCIATED WITH THAT PERMIT. PLEASE | | | CORRECT AND SHOW THE 8 INCH ROUND DUCT AS NEW WORK PART | | | OF THIS PERMIT. FBCB 106.1.1. | | | | | | 5. THE KITCHEN HOODS AND GREASE DUCTS ARE ALSO UNDER A | | | SEPARATE PERMIT #08010158. IF HOOD-3, RELATED DUCTWORK | | | AND FANS ARE TO BE ELIMINATED, PLANS FOR PERMIT | | | #08010158 SHALL ALSO BE REVISED. ALL WORK SHALL BE DONE | | | IN ACCORDANCE WITH PERMITTED CONSTRUCTION DOCUMENTS AND | | | ANY CHANGES SHALL BE SUBMITTED FOR REVIEW IN ACCORDANCE | | | WITH FBCB 106.4. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-05-04 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-05-04 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2007-05-04 10:35:04 | *************PROVISO************** | | | | | | 1. WORK IN SHAFT IS BEING DONE UNDER PERMIT #07010023. | | | THE CONDITIONS OF THAT PERMIT SHALL BE SATISFIED PRIOR | | | TO FINAL INSPECTION. | | | 2. GREASE EXHAUST DUCTS AND HOODS SHALL BE UNDER | | | SEPARATE "MECHHOOD" PERMIT. | | | 3. HOOD SUPPRESSION SYSTEMS AND WALK-IN COOLERS REQUIRE | | | SEPARATE PERMITS. WORK REQUIRING ADDITIONAL PERMITS | | | SHALL NOT BE STARTED ORIOR TO SECURING THOSE PERMITS. | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-02-14 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-02-14 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2006-10-11 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2006-10-10 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2006-10-11 19:01:58 | ------------------DENIED------------------------- | | | | | | 1. EXISTING AHU 1 ACCESS MUST BE LARGE ENOUGH FOR | | | REPLACEMENT OF EQUIPMENT PER FBC,M 306 | | | | | | 2. KSF 1 REQUIRES DUCT MOUNTED SMOKE DETECTOR AS IT | | | EXCEEDS 2,000 CFM.ALL DUCT DETECTORS ARE TO BE TIED | | | IN TO THE BUILDING FIRE ALARM SYSTEM PER FBC,M 606 | | | | | | 3. VERIFY KSF 1 INTAKE IS IN COMPLIANCE WITH FBC,M | | | 401.5.1 | | | | | | 4. PROVIDE DETAIL FOR GREASE EXHAUST DUCT PENETRATIONS | | | THROUGH RATED WALLS AND SHAFTS. SHOW COMPLIANCE WITH | | | FBC,M 506.3.10 WITH 2 HOUR LISTED SYSTEMS TO BE USED | | | AND INSTALLATION INSTRUCTIONS. | | | | | | 5. HORIZONTAL GREASE EXHAUST DUCT THROUGH LOBBY FOR | | | LOFTS REQUIRES CLEAN OUTS PER 506.3.9. HOW WILL ASSESS | | | TO CLEAN-OUTS BE PROVIDED IN LOBBY AREA? | | | | | | 6. PAGE M3: A/C ROOF EQUIPMENT MOUNTING DETAIL NOTE | | | REFERS TO FBC 2001. PLEASE REFERENCE FBC 2004. | | | | | | 7. PAGE M4: BALANCING GREASE EXHAUST DAMPER DETAIL - IS | | | THERE TO BE A BALANCING DAMPER INSIDE THE GREASE | | | EXHAUST DUCT? IS THERE A GAP BETWEEN THE HOOD COLLAR | | | AND THE DUCT? PLEASE CLARIFY. | | | | | | 8. SEPERATE PERMITS ARE REQUIRED FOR A/C, HOOD SYSTEMS, | | | HOOD SUPPRESSION SYSTEMS, WALK-IN COOLERS/FREEZERS. | | | ONLY THE A/C AND GREASE EXHAUST DUCT SYSTEMS WERE | | | REVIEWED FOR CODE COMPLIANCE. APPLICATIONS AND | | | SUBMITTALS FOR ALL OTHER SYSTEMS WILL BE REQUIRED PRIOR | | | TO ISSUANCE OF EACH PERMIT. | | | | | | REVIEWED BY: | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-08 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-08 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2008-08-08 16:17:31 | REVISIONS OK--SHTS P-1, P-2 & P-3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2008-06-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-06-17 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-06-11 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2008-06-17 10:03:23 | REVISIONS OK--SHTS P-I & P-3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
N |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-20 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-20 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2008-05-20 11:24:01 | REVISION NOT REQUIRED.--SHT P-0, NO NEW REVISION | | | NUMBER INDICATED AND NO CHANGES NOTED ON SHT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-20 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-20 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2008-05-20 11:22:44 | REVISIONS OK--SHTS P-I, P-2 & P-3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-10 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-10 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2007-08-10 13:27:05 | PASSED PROVISO | | | | | | REVISIONS REQUIRED FOR SHEETS P-1 & P-3 (SANT. RISER | | | DIAGRAM) PRIOR TO SETTING THE GREASE INTERCEPTORS. THE | | | GREASE INTERCEPTORS SHALL BE INSTALLED IN PARALLEL, NOT | | | SERIES AS INDICATED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-01 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-01 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2007-06-01 16:20:33 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | MUNICIPAL CITY CODE | | | | | | FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | | | | 4. GREASE INTERCEPTOR SHALL BE SIZED BY | | | LYNN MASSON, ENVIRONMENTAL COMPLIANCE | | | MANAGER. CONTACT LYNN BY PHONE (561) | | | 822-2271, OR BY FAX (561) 822-2279, OR | | | E-MAIL [email protected]. MUNICIPAL CODE | | | SECTION 3434. | | | ****RESPONSE NOTED, BUT NO FEEDBACK FROM ENVIRONMENTAL | | | COMPLIANCE AS OF YET. | | | *******RESPONSE FROM RODNEY COMPO IS IN CONFLICT WITH | | | INFORMATION SUBMITTED FROM ED SAMOUR. THE TABLES AND | | | BENCH SEATING ARE APPROX. 152 SEATS, AND THE OCCUPANCY | | | INDICATES APPROX. 200. SEE COPY OF ATTACHED SHEET FROM | | | ENVIRONMENTAL COMPLIANCE REQUIRING 3, 1250 GAL GREASE | | | INTERCEPTORS. | | | | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | A. OK | | | B. OK | | | C. OK | | | D. OK | | | E. N/A | | | F. N/A | | | G. OK | | | | | | **********NEW COMMENT************* | | | | | | 1B. OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-12 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-12 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2007-02-12 12:36:30 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | MUNICIPAL CITY CODE | | | | | | FROM PREVIOUS REVIEW: | | | | | | 1. PLANS SHALL BE ROUTED TO DBPR | | | RESTURANT AND HOTEL DIVISION FOR REVIEW | | | PRIOR TO RESUBMITTING. PLANS SHALL BE | | | STAMPED AND TWO PAGE "WORKSHEETS" | | | ATTACHED TO EACH SET OF PLANS TO BE | | | SUBMITTED. SECTION 102.2.1. | | | ****NO RESPONSE, NOT ADDRESSED | | | | | | 2. OK | | | 3. OK | | | | | | 4. GREASE INTERCEPTOR SHALL BE SIZED BY | | | LYNN MASSON, ENVIRONMENTAL COMPLIANCE | | | MANAGER. CONTACT LYNN BY PHONE (561) | | | 822-2271, OR BY FAX (561) 822-2279, OR | | | E-MAIL [email protected]. MUNICIPAL CODE | | | SECTION 3434. | | | ****RESPONSE NOTED, BUT NO FEEDBACK FROM ENVIRONMENTAL | | | COMPLIANCE AS OF YET. | | | | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | A. OK | | | B. OK | | | C. OK | | | D. OK | | | E. N/A | | | F. N/A | | | G. OK | | | | | | **********NEW COMMENT************* | | | | | | 1B. SHTS P-1 & P-3 THE DISHWASHER SHALL CONNECT TO THE | | | SANITARY, NOT THE GREASE SYSTEM. MUNICIPAL | | | 90-124(7)(B). (MISSED ON FIRST REVIEW) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-08 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-07 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2006-09-08 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. PLANS SHALL BE ROUTED TO DBPR | | | RESTURANT AND HOTEL DIVISION FOR REVIEW | | | PRIOR TO RESUBMITTING. PLANS SHALL BE | | | STAMPED AND TWO PAGE "WORKSHEETS" | | | ATTACHED TO EACH SET OF PLANS TO BE | | | SUBMITTED. SECTION 102.2.1 | | | | | | 2. SUBMIT CALCULATIONS FOR MINIMUM | | | FIXTURE REQUIREMENTS. TABLES 1004.1.2 | | | AND 403.1. | | | | | | 3. SUBMIT AN EXISTING FLOOR PLAN TO | | | DETERMINE THE EXTENT OF THE DEMO WORK TO | | | BE DONE. SECTION 106.1.1. | | | | | | 4. GREASE INTERCEPTOR SHALL BE SIZED BY | | | LYNN MASSON, ENVIRONMENTAL COMPLIANCE | | | MANAGER. CONTACT LYNN BY PHONE (561) | | | 822-2271, OR BY FAX (561) 822-2279, OR | | | E-MAIL [email protected]. MUNICIPAL CODE | | | SECTION 3434. | | | | | | 5. SHT A1.1 EQUIPMENT LIST INDICATES TWO | | | #19 HAND SINKS, BUT ONLY ONE WAS FOUND. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 6. SHT P-0 PLUMBING SPECIFICATIONS. | | | FLOOR DRAINS ARE NOT AN APPROVED | | | INDIRECT WASTE RECEPTOR. FLOOR SINKS OR | | | HUB DRAINS SHALL BE USED. SECTIONS 802.3 | | | AND 802.3.2. | | | | | | 7. SHT P-3 DOMESTIC WATER ISOMETRIC. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES, IN AN "EFFECTIVE | | | RANGE", NOT IN THE CEILING AS SHOWN. | | | PDI-WH 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS. | | | | | | 8. SHT P-3 THE FOLLOWING INFORMATION IS | | | REQUIRED FOR REQUIRED GAS PERMIT: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. LENGTHS NOT SHOWN. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | E. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | F. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | G. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. UNION NOT | | | SHOWN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-08-07 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-08-07 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|