| Plan Review Stops For Permit 06081875 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-03-15 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-15 |
Time |
12:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-11-12 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-11-12 |
Time |
21:37 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-11-12 |
Time |
21:36 |
Sent To |
|
|
| Notes |
| 2006-11-12 21:37:40 | REVISED PLAN |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-09-23 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-09-23 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-13 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-13 |
Time |
15:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-16 |
Time |
13:00 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-02-16 |
Time |
12:00 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-03 |
Time |
15:59 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-11-02 |
Time |
12:05 |
Sent To |
M |
|
| Notes |
| 2006-11-03 15:59:24 | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} SHOW THE GROUNDING ELECTRODE SYSTEM CONNECTIONS PER | | | 250.66. SEE THAT THE LOCATION OF THE ATS NOW MAKES IT | | | THE FIRST MEANS OF DISCONNECT., SHOW MAIN BONDING | | | JUMPER AND NOTE THAT THE NEUTRAL AND GROUND MUST BE | | | ISOLATED BEYOND THAT. ALSO NOTE THAT NO EQUIPMENT | | | GROUND IS SHOWN FROM THE SERVICE TO THE GENERATOR WITH | | | THAT FEED. | | | | | | 2} THERE MUST BE TWO COPIES OF ALL DOCUMENTS SUBMITTED | | | FOR REVIEW, I CAN ONLY FIND ONE OF THE ATS. | | | | | | 3} SECTION 3.2 OF THE ATS MANUAL INDICATES A | | | DISCONNECTING MEANS IS REQUIRED AHEAD OF THE ATS FOR | | | THE GENERATOR AND UTILITY POWER PRIOR TO MANUAL | | | OPERATION. IT DOES NOT APPEAR THIS SWITCH IS RATED AS A | | | SERVICE DISCONNECTING MEANS, AND THEREFORE SHOULD NOT | | | BE POSITIONED IN THE SERVICE AS SHOWN. | | | | | | 4} PLEASE CALCULATE THE SERVICE LOAD PER 220 SECTION I, | | | STANDARD, OR 220 SECTION III, OPTIONAL. DEMANDS CANNOT | | | BE REVIEWED FOR COMPLIANCE UNDER THE FORMAT THAT WAS | | | SUBMITTED ON THIS PLAN. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-14 |
Time |
12:54 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-14 |
Time |
11:17 |
Sent To |
M |
|
| Notes |
| 2006-09-14 00:00:00 | | | | | | | NONCOMPLIANT. | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT | | | ON THE PLAN, METER ENCLOSURE, | | | DISCONNECTS AND PANELS, SO THAT | | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN | | | BE REVIEWED. | | | | | | 2} PROVIDE A RISER DIAGRAM SHOWING | | | ELECTRICAL CONNECTION OF ALL SERVICE AND | | | GENERATOR EQUIPMENT. | | | | | | 3} PROVIDE MANUFACTURERS | | | SPECIFICATIONS/RECOMMENDATION, REGARDING | | | CLEARANCES. | | | | | | 4} PROVIDE SPECIFICATIONS FOR THE | | | TRANSFER SWITCH. | | | | | | 5} PROVIDE A CALCULATION FOR THE LOAD | | | BEING SERVED BY THE GENERATOR. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
7 |
Status |
P |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-08 |
Time |
10:04 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-08-08 |
Time |
10:04 |
Sent To |
PC |
|
| Notes |
| 2007-08-08 10:06:45 | REVISION: UPGRADING TO A 2 LB. NAT/GAS SYSTEM. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
6 |
Status |
F |
Date |
2007-07-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-24 |
Time |
10:55 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2007-07-24 |
Time |
10:55 |
Sent To |
PC |
|
| Notes |
| 2007-07-24 11:13:38 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | 1. NOTE: ONLY ONE (1) SHEET P-1 WAS SEALED BY THE | | | ARCHITECT KELLY D. YATES, FLORIDA AR #13706. | | | A} 106.1 SUBMITTAL DOCUMENTS. CONSTRUCTION | | | DOCUMENTS, SPECIAL INSPECTION AND | | | STRUCTURAL OBSERVATION PROGRAMS, AND | | | OTHER DATA SHALL BE SUBMITTED IN TWO OR | | | MORE SETS WITH EACH APPLICATION FOR A | | | PERMIT. | | | B} 106.1 SUBMITTAL DOCUMENTS. IF THE DESIGN | | | PROFESSIONAL IS AN ARCHITECT | | | LEGALLY REGISTERED UNDER THE LAWS OF | | | THIS STATE REGULATING THE PRACTICE OF | | | ARCHITECTURE AS PROVIDED FOR IN CHAPTER | | | 481, FLORIDA STATUTES, PART 1 THEN HE OR SHE | | | SHALL AFFIX HIS OR HER SEAL, SIGNATURE | | | AND DATE TO SAID DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA, AS | | | REQUIRED BY FLORIDA STATUTES. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS REVIEWER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-28 |
Time |
09:25 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-06-28 |
Time |
09:25 |
Sent To |
PC |
|
| Notes |
| 2007-06-28 10:38:02 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION IS REQUIRED FOR | | | GAS PLAN REVIEW FOR THE REVISION TO MEET CODE | | | COMPLIANCE: | | | | | | 1. NOTE: THE ORIGINAL NATURAL GAS ISOMETRIC RISER | | | DIAGRAM ON SHEET P-1 WERE SIGNED AND SEALED BY | | | ARCHITECT KELLY D. YATES, ANY REVISED DRAWING TO THE | | | GAS SYSTEM PER CHAPTER 481, FLORIDA STATUTES, PART 1, | | | MUST ALSO BE SIGNED AND SEALED BY SAID DESIGN | | | PROFESSIONAL. ALSO A TITLE BLOCK IS REQUIRED PER, | | | FAC-61G1-16.004 TITLE BLOCK: | | | A TITLE BLOCK MUST APPEAR ON ALL | | | ARCHITECTURAL OR INTERIOR DESIGN | | | DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK | | | MUST, AT A MINIMUM, CONTAIN THE | | | FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE | | | NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED | | | SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE | | | PERSON SEALING THE DOCUMENT. | | | (7) FIRMS CERTIFICATE OF AUTHORIZATION NUMBER PER FS | | | 481.219 | | | | | | 2. PER FBC-2004 FUEL GAS, SECTION 409.4 MP REGULATOR | | | VALVES: A LISTED SHUTOFF VALVE SHALL BE INSTALLED | | | IMMEDIATELY AHEAD OF EACH MP REGULATOR. PLEASE INDICATE | | | THIS ON THE RESUBMITTED REVISION. | | | | | | 3. PLEASE CLEARLY INDICATE THE ABOVE GROUND AND | | | UNDERGROUND PIPING MATERIAL OF THE GAS SYSTEM. THERE | | | WAS A REVISION ON THE ORIGINAL DOCUMENTS DATED 3-20-07 | | | (PLAN REVIEW COMMENTS) IN THE PLUMBING NOTES #5 GAS | | | PIPING: POLYETHELENE PLASTIC PIPE (PE). PLEASE CLARIFY | | | THIS ON THE RESUBMITTED REVISION. | | | | | | 4. NOTE: THE DRIP LEG DETAIL INDICATED ON THE REVISION | | | IS WRONG. PLEASE CORRECT THE REVISION PER FBC-2004 FUEL | | | GAS SECTION 408.4 A SEDIMENT TRAP SHALL BE INSTALLED | | | DOWNSTREAM OF THE EQUIPMENT SHUTOFF VALVE AS CLOSE TO | | | THE INLET OF THE EQUIPMENT AS PRACTICAL. A **PROVISO** | | | WAS PUT ON THE PERMIT COPIES REFLECTING THIS. | | | | | | 5. PLEASE PROVIDE TWO COPIES MANUFACTURER'S | | | SPECIFICATION OF THE MP REGUALTORS WITH THE FOLLOWING | | | INFORMATION. | | | A} MAKE. | | | B} MODEL NUMBER. | | | C} MAXIMUM INDIVIDUAL LOAD CAPACITY (LARGEST | | | SINGLE APPLIANCE SERVED BY THE REGULATOR) | | | D} CAPACITY OF REGULATOR (TOTAL LOAD OF ALL | | | APPLIANCES COMBINED) | | | E} SHOW A LISTING FROM A NATIONALLY RECOGNIZED | | | TESTING LABORATORY (NRTL). | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-18 |
Time |
14:32 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-04-18 |
Time |
14:32 |
Sent To |
PC |
|
| Notes |
| 2007-04-18 14:37:09 | ****************PROVISO**************** | | | PER FBC-2004 FUEL GAS, SECTION 408.4 A SEDIMENT TRAP | | | SHALL BE INSTALLED DOWNSTREAM OF THE EQUIIPMENT SHUTOFF | | | VALVE AS CLOSE TO THE INLET OF THE EQUIPMENT AS | | | PRACTICAL. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-20 |
Time |
10:27 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-02-20 |
Time |
10:27 |
Sent To |
B |
|
| Notes |
| 2007-02-20 11:46:34 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS AND CITY OF WEST PALM | | | BEACH GAS PERMIT APPLICATION REQUIREMENTS: | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | | MADE ON PREVIOUS REVIEWS. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | | PREVIOUS REVIEW NOTES. | | | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | | | 1. OK | | | | | | 2. NO. | | | ** SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | NOTE: SHEET P-1 INDICATES PIPING MATERIAL TO BE | | | SCHEDULE 40 BLACK STEEL. | | | | | | A} PER FBC-2004 FUEL GAS, SECTION 404.8 PROTECTION | | | AGAINST CORROSION. FERROUS METAL EXPOSED IN EXTERIOR | | | LOCATIONS SHALL BE PROTECTED FROM CORROSION IN A MANNER | | | SATISFACTORY TO THE CODE OFFICIAL. | | | NOTE: PLEASE ADD TO RESUBMITTED NOTES. | | | | | | B} PER FBC-2004 FUEL GAS, SECTION 404.8.1 PROHIBIED | | | USE, UNCOATED THREADED OR SOCKET WELDED JOINTS SHALL | | | NOT BE USED IN PIPING IN CONTACT WITH SOIL OR WHERE | | | INTERNAL OR EXTERNAL CREVICE CORROSION IS KNOWN TO | | | OCCUR. | | | NOTE: PLEASE ADD TO RESUBMITTED NOTES. | | | | | | C} PER FBC-2004 FUEL GAS, SECTION 404.8.2 PROTECTIVE | | | COATINGS AND WRAPPING. PIPE PROTECTIVE COATINGS AND | | | WRAPPINGS SHALL BE APPROVED FOR THE APPLICATION AND | | | SHALL BE FACTORY APPLIED. | | | NOTE: PLEASE ADD TO RESUBMITTED NOTES. | | | | | | ** NOTE: IT IS SUGGESTED THAT ANY NEW UNDERGROUNG | | | PIPING MATERIAL FOR THE GAS SYSTEM BE POLYETHYLENE | | | PLASTIC PIPE (PE). ALSO IF PE PIPE IS USED FOR THE | | | GENERATOR THE PIPE SIZE WILL NEED TO BE INCREASED TO | | | 2-1/2" FOR THE GENERATOR. PLEASE BE AWARE THAT | | | UNDERGROUND GALVANIZED PIPE IS UNACCEPTABLE TO THE CODE | | | OFFICIAL PER FBC-2004 FUEL GAS, SECTION 404.8. | | | | | | 3. OK | | | | | | 4. OK | | | | | | 5. NO | | | ** INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | NOTE: THE REFERENCE TO THE FUEL GAS TABLE 402.4 (2) IS | | | NOT ACCEPTABLE AS A DELIVERY PRESSURE. DELIVERY | | | PRESSURE CAN NOT BE ASSUMED, IT MUST BE CLEARLY | | | INDICATED ON THE RESUBMITTAL. | | | | | | 6. OK | | | | | | 7. OK | | | | | | 8. OK | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-07 |
Time |
09:16 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-11-07 |
Time |
09:15 |
Sent To |
B |
|
| Notes |
| 2006-11-07 09:55:33 | UNSAT | | | REFERENCE: FBC-2004 FUEL GAS AND FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR GAS PLAN | | | REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | NOTE: THE SUBMITTED DRAWING IS NOT AN ISOMETRIC AND | | | DOES NOT SHOW ALL CUT SECTIONS OF PIPE AND | | | CORRESPONDING LENGTHS. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | NOTE: ON THE RESUBMITTED ISOMETRIC PLEASE INDICATE ALL | | | PIPING MATERIAL AND PIPE SIZES. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | NOTE: ON THE RESUBMITTED ISOMETRIC PLEASE INDICATE THE | | | BTU LOAD OF THE GENERATOR AND THE EXISTING BTU LOAD OF | | | SAID ADDRESS. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | NOTE:THIS INCLUDES THE EXISTING SYSTEM AS WELL AS | | | THE PROPOSED GENERATOR. | | | | | | 5. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 6. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | NOTE: PLEASE SUBMIT MANUFACTURER SHEETS OF MP | | | REGULATORS. | | | | | | 7. PROVIDE NOTICE OF COMMENCEMENT RECORDED WITH THE | | | CLERK OF COURT BEFORE A PERMIT CAN BE ISSUEDNOTE: THE | | | ORIGINAL NOC SUBMITTED WITH THE GENERATOR APPLICATION | | | DOES NOT INCLUDE GAS SYSTEM OR CONTRACTOR. | | | | | | 8. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-18 |
Time |
15:58 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-09-18 |
Time |
15:58 |
Sent To |
B |
|
| Notes |
| 2006-09-18 00:00:00 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/RES INSPECTION. | | | | | | ******IMPORTANT INFORMATION****** | | | AS OF 8/25/06 GENERATOR (GEN/RES AND | | | GEN/COM) PERMIT APPLICATIONS SHALL NOT | | | BE ACCEPTED UNLESS THE ELECTRICAL INFOR- | | | MATION AND GAS (OR DIESEL) INFORMATION | | | IS ALL SUBMITTED AT THE SAME TIME. THE | | | GENERATOR, ELECTRICAL AND GAS/DIESEL IN- | | | FORMATION WILL BE ROUTED TOGETHER. THIS | | | WILL ENSURE THAT ALL OF THE INFORMATION | | | (PARTICULARLY THE MANUFACTURER'S SPECI- | | | FICATIONS AND INSTALLATION INSTRUCTIONS) | | | ARE AVAILABLE TO ALL PLAN REVIEWERS. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-11 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-11 |
Time |
12:43 |
Sent To |
E |
|
| Notes |
| 2007-09-11 12:43:33 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-06 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-06 |
Time |
17:08 |
Sent To |
G |
|
| Notes |
| 2007-08-06 17:09:11 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-10 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-10 |
Time |
10:02 |
Sent To |
P |
|
| Notes |
| 2007-07-10 10:02:54 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-08 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-08 |
Time |
14:50 |
Sent To |
G |
|
| Notes |
| 2007-06-08 14:51:11 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-05 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-05 |
Time |
17:19 |
Sent To |
G |
|
| Notes |
| 2007-04-05 17:20:03 | TO MIKE PERSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-15 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-15 |
Time |
09:59 |
Sent To |
E |
|
| Notes |
| 2007-02-15 09:59:51 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-02 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-02 |
Time |
16:40 |
Sent To |
Z |
|
| Notes |
| 2007-02-02 16:41:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-01 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-01 |
Time |
18:48 |
Sent To |
E |
|
| Notes |
| 2006-11-01 18:48:43 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-24 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-24 |
Time |
13:22 |
Sent To |
Z |
|
| Notes |
| 2006-10-24 13:23:04 | TO "Z" BOX/RESUB--NEW SHEETS SUBMITTED FOR ALL TRADES. | | | GAS APPL. ATTACHED TO THIS RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
09:37 |
Sent To |
E |
|
| Notes |
| 2006-09-05 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-09-23 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-08-23 |
Time |
15:16 |
Sent To |
PC |
|
| Notes |
| 2006-08-23 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-03 |
Time |
16:29 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-11-03 |
Time |
16:29 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-18 |
Time |
13:42 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-09-18 |
Time |
13:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-02-14 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-02-14 |
Time |
10:51 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-10-31 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-10-31 |
Time |
14:33 |
Sent To |
I |
|
| Notes |
| 2006-10-31 14:33:31 | PROPOSED GENERATOR - RE-STAMP NEW PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-02 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-02 |
Time |
10:50 |
Sent To |
I |
|
| Notes |
|
|