Plan Review Details - Permit 06081850
Plan Review Stops For Permit 06081850
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-09-08 Cont ID  
Sent By jgomez Date 2006-09-08 Time 12:53 Rev Time 0.50
Received By jgomez Date 2006-09-08 Time 12:53 Sent To  
Notes
2006-09-08 00:00:00BUILDING REVIEW CHECKLIST:
 1- PROVIDE COMPLETE INSTALLATION
 SCHEDULE TO PERFORM PLAN REVIEW AND
 PRODUCT COMPLIANCE WITH THE PROPOSED
 INSTALLATION. SEE ATTACHED COPY OF CITY
 IMPLEMENTATION STANDARD FOR SHUTTERS
 INSTALLATION TO FIND OUT INSTALLATION
 SCHEDULE SAMPLE. FILL OUT ALL THE
 INFORMATION THAT APPLIES TO THE
 ACCORDION SHUTTERS.
  
 2- TYPICALLY HOUSES ARE CBS, NOT
 CONCRETE. PLEASE VERIFY THAT HOUSE
 CONSTRUCTION IS CONCRETE (MIN. 3,320
 PSI) IN ORDER TO USE THE CONCRETE VALUES
 OF THE INSTALLATION SCHEDULE.
 IF HOUSE IS BUILT WITH CBS, THEN THE
 CONCRETE BLOCK VALUES SHALL BE USED.
 OTHERWISE, PROVIDE COMPLETE ENGINEERING
 ANALYSIS USING CONCRETE BLOCK WITH
 FILLED CELLS. SEC. 104.1.2 OF CITY
 AMENDMENTS TO FBC 2004.
  
 3- CONTRACTOR TO UPDATE INSURANCE WITH
 PERMIT CLERK.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712