| Plan Review Stops For Permit 06081508 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-06-12 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-06-12 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2007-06-12 12:58:31 | STRUCTURAL REVISIONS # 4 ARE APPROVEDLM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-27 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-27 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-24 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-24 |
Time |
13:59 |
Sent To |
P |
|
| Notes |
| 2006-10-24 14:00:25 | | | | DENIED | | | | | | | | | 8.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A | | | STORM SEWER CONVEYANCE OR OTHER APPROVED | | | POINT OF COLLECTION SO AS TO NOT CREATE | | | A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION | | | WALLS. THE GRADE AWAY FROM FOUNDATION | | | WALLS SHALL FALL A MINIMUM OF 6 INCHES | | | WITHIN THE FIRST 10 FEET. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-28 |
Time |
08:56 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-09-28 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2006-09-28 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | | THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT SET OF | | | PLANS MUST BE STAMPED BY THAT OFFICE, | | | AND A COPY OF THE PAID RECEIPT ATTACHED | | | TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025 | | | FOR MORE INFORMATION. | | | | | | 3.SHOW GUARDRAIL DETAIL.SHOW | | | COMPLIANCE WITH R-312.2 NOT FBC 1012 OR | | | 1607. | | | | | | 4."R" VALUES ON ENERGY CALCS DO NOT | | | MATCH PLANS. | | | | | | 5.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMENDMENT TO FBC 106.3.3. | | | | | | 6.SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | TRUSS DRAWING REQUIRED TO BE APPROVED | | | PRIOR TO INSTALLATION. | | | | | | 7.A DESIGN PROFESSIONAL OR AN OWNER | | | MUST ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | SHOW HOW PLANS WILL COMPLY WITH THE | | | SECTION(S) SELECTED.2004 FBC EXISTING | | | BUILDING 301.5 | | | | | | 8.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A | | | STORM SEWER CONVEYANCE OR OTHER APPROVED | | | POINT OF COLLECTION SO AS TO NOT CREATE | | | A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION | | | WALLS. THE GRADE AWAY FROM FOUNDATION | | | WALLS SHALL FALL A MINIMUM OF 6 INCHES | | | WITHIN THE FIRST 10 FEET. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-02-06 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-02-06 |
Time |
12:09 |
Sent To |
PC |
|
| Notes |
| 2008-02-06 12:12:04 | | | | | | | LETTER FROM ARCHITECT REMOVING OUTLETS PER | | | INSPECTOR./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-27 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-27 |
Time |
11:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-06 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-06 |
Time |
08:11 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-27 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-19 |
Time |
07:38 |
Sent To |
M |
|
| Notes |
| 2007-06-19 08:00:15 | | | | | | | | | | REVISION DENIED/INCOMPLETE INFORMATION | | | | | | THE PANEL SCHEDULES HAVE BEEN REMOVED FROM THE PLAN. | | | PLEASE SUBMIT PLANS WITH PANEL SCHEDULES PER 106.3.5.4 | | | FBC AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-26 |
Time |
16:23 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-10-26 |
Time |
16:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-16 |
Time |
09:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-16 |
Time |
07:59 |
Sent To |
M |
|
| Notes |
| 2006-10-16 09:32:54 | | | | DENIED/INCOMPLETE DESIGNER INFORMATION, (2ND TIME) | | | | | | THE ARCHITECTS SEAL MUST BE DATED PER 61G1-16.004(4) | | | FAC. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-28 |
Time |
13:01 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-08-28 |
Time |
08:00 |
Sent To |
P |
|
| Notes |
| 2006-08-28 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE ARCHITECTS DATES ON THE SEAL, | | | SHEETS E-2, DO NOT CORRELATE. | | | | | | 2} THE GROUND RAN WITH THE FEEDER TO THE | | | NEW PANEL VIOLATES 250.6, AND WOULD | | | RESULT IN OBJECTIONABLE CURRENTS BETWEEN | | | THE NEUTRAL AND GROUND. PLEASE REMOVE. | | | | | | 3} NOTE THE NEW PANEL FEEDER MUST COMPLY | | | WITH 230.70(A)(1), IF THE FEED IS | | | OVERHEAD FROM THE METER, A DISCONNECT IS | | | REQUIRED OUTSIDE, AND GROUPED PER | | | 230.72. PLEASE INDICATE ON THE RISER. | | | | | | 4} THE PANEL SCHEDULE REFLECTS FOUR AIR | | | HANDLERS, THE CALCULATION ONLY TWO. | | | PLEASE CORRELATE. | | | | | | 5} 210.8(A)(6)GFI'S ARE | | | REQUIRED: KITCHENS;WHERE THE | | | RECEPTACLES ARE INSTALLED TO SERVE THE | | | COUNTERTOP SURFACES. SOME ARE MISSING ON | | | THE PLAN. | | | | | | 6} THE POOL HEATER AND PUMP SHOWN ON THE | | | PLAN ARE NOT IN THE CALCULATION, PLEASE | | | INCLUDE SAME. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2008-02-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-02-05 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-02-05 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2008-02-05 11:18:04 | SEE #07120319 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-12-18 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-12-18 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2007-12-18 15:25:01 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE PROVIDE A DETAIL DRAWING SHOWING ALL THE | | | DIMENSIONS FOR DRIVEWAY, APPROACH, SIDEWALK ETC. | | | | | | 2. YOU ARE PUTTING AN APPROACH, DRIVEWAY, SIDEWALK & | | | CUTTING A CURB IN CITY'S RIGHT OF WAY. THEREFORE, YOU | | | NEED CITY'S RIGHT OF WAY APPROVAL FROM WINDEL PALMER | | | 494-1040, 1000 45TH STREET, ENG DEPT.ONCE WE HAVE AN | | | APPROVAL FROM WINDEL PALMER, WE WILL REVIEW YOUR | | | DRAWINGS. | | | | | | 3. MUST MEET CITY'S STANDARDS FOR APPROACH, | | | SIDEWALK,DRIVEWAY ETC. A SHEET " TYPICAL PAVER | | | STONE/CONCRETE DRIVEWAY APPROACH DETAILS" ENCLOSED FOR | | | YOUR USE. | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-24 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-24 |
Time |
13:50 |
Sent To |
E |
|
| Notes |
| 2006-08-24 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-24 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-24 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2007-12-24 10:11:35 | SENT TO "BT" MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-20 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:12 |
Sent To |
E |
|
| Notes |
| 2007-12-20 17:13:11 | ROUTED TO "BT"DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-27 |
Time |
12:01 |
Rev Time |
|
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2007-06-27 12:01:18 | | | | | | | | | | LOW VOLTAGE #07050943 BROUGHT IN ON THIS NUMBER BY | | | MISTAKE./WRT. | | 2007-06-26 15:30:11 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-15 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-15 |
Time |
11:20 |
Sent To |
E |
|
| Notes |
| 2007-06-15 11:21:14 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-18 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-18 |
Time |
08:49 |
Sent To |
B |
|
| Notes |
| 2007-05-18 08:49:33 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-14 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-14 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2006-10-14 17:17:53 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-28 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2006-08-17 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2006-08-17 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-02 |
Time |
08:30 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-08-02 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2007-08-02 08:31:28 | **MECHANICAL REVISION PAGE M-1** | | | *** PROVISO *** | | | 1) DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS | | | OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE | | | SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET | | | STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO | | | OPENINGS INTO THE GARAGE. PER 2004 FBC/R 309.1.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-20 |
Time |
14:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-07-20 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2007-07-20 14:34:59 | **MECHANICAL REVISION PAGE M-1** | | | *** PROVISO *** | | | 1) DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS | | | OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE | | | SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET | | | STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO | | | OPENINGS INTO THE GARAGE. PER 2004 FBC/R 309.1.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-19 |
Time |
09:26 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-06-19 |
Time |
09:26 |
Sent To |
P |
|
| Notes |
| 2007-06-19 09:30:08 | REVISION TO MECH. PLANS PAGE M-2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-16 |
Time |
12:09 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-16 |
Time |
12:09 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-14 |
Time |
10:22 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-09-14 |
Time |
10:22 |
Sent To |
B |
|
| Notes |
| 2006-09-14 00:00:00 | *** DENIED *** | | | 1) THE MECHANICAL PLANS NEED SMITHCO | | | SERVICE'S ADDRESS AND PHONE NUMBER ON | | | THEN. | | | | | | 2) ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | 3) THE RETURN AIR TRANSFER DUCT TO THE | | | MASTER SUITE NEEDS TO BE 16", SEE NOTE | | | #4 (C) EXCEPT. | | | | | | 4) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-07-03 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-03 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2007-07-03 13:24:39 | PLUMBING REVISIONS OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-25 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-25 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-14 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-14 |
Time |
07:38 |
Sent To |
M |
|
| Notes |
| 2006-09-14 00:00:00 | DENIED; | | | 1.AUTOMATIC CLOTHES WASHER TO DISCHARGE | | | BELOW LAUNDRY TUB. A SANITARY CROSS CAN | | | NOT BE USED. SEEFBC-2004 PLUMBING | | | SECTION 706.3. | | | 2.BATHROOM # 3 SHOWER NOT VENTED. SEE | | | SECTION 909.1. | | | 3.OUTSIDE SHOWER TO DRAIN TO GRASSY AREA | | | NOT SEWER SYSTEM. RAIN WATER NOT NEEDED | | | IN SEWER SYSTEM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-23 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-23 |
Time |
17:30 |
Sent To |
I |
|
| Notes |
|
|