| Plan Review Stops For Permit 06081426 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-09-07 |
Time |
19:43 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-09-07 |
Time |
19:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-25 |
Time |
08:14 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-08-25 |
Time |
07:51 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-25 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-08-25 |
Time |
10:50 |
Sent To |
B |
|
| Notes |
| 2006-08-25 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-09 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-09 |
Time |
17:41 |
Sent To |
Z |
|
| Notes |
| 2006-09-09 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-24 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-24 |
Time |
14:44 |
Sent To |
E |
|
| Notes |
| 2006-08-24 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-09-07 |
Time |
19:43 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-08-16 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2006-08-16 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-25 |
Time |
10:47 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-08-25 |
Time |
10:47 |
Sent To |
G |
|
| Notes |
| 2006-08-25 00:00:00 | | | | | | | | | | ******PROVISO****** | | | 1) FBC-2004 SEC. 424.2.14.4, OR | | | FBCR-2004 SEC. R4101.14.4 CONNECTIONS, | | | ALL WATER HEATING EQUIPMENT SHALL BE | | | INSTALLED WITH FLANGES OR UNION | | | CONNECTIONS ADJACENT TO THE HEATER. | | | (ADD TO NOTES) | | | 2) FBC-2004 SEC. 424.2.14, OR FBCR-2004 | | | SEC. R4101.15 GAS PIPING SHALL COMPLY | | | WITH FBC FUEL GAS.SEPARATE PLANS AND | | | PERMIT REQUIRED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-15 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-15 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2006-09-15 00:00:00 | NOTE: CLASS B APPROVED - CASE# 3167, | | | FRONT SETBACK APPROVED 12FT 2-1/2 INCHES | | | AND MUST PROVED A LANDSCAPE BUFFER IN | | | THE FRONT. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-18 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-18 |
Time |
08:23 |
Sent To |
I |
|
| Notes |
| 2006-08-23 00:00:00 | DENIED, | | | 1. THE PROPOSED POOL/SPA & DECK MUST SIT | | | BACK BEYOND THE 25FT FRONT SETBACK OF | | | OLIVE AVE. | | | 2. IF A VARIANCE WAS APPLIED FOR | | | APPROVED, PLEASE SUBMIT A COPY OF | | | DOCUMENT WITH APPLICATION. | | | 3. PLEASE SHOW THE POOL EQUIPMENT ON THE | | | TWO COPY OF SURVEY. | | | | | | SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|