Plan Review Details - Permit 06081258
| Plan Review Stops For Permit 06081258 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-25 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-25 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-14 |
Time |
11:58 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-09-14 |
Time |
11:36 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-25 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-25 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE PROVIDE A CALCULATION INCLUDI- | | | NG ALL ADDED LOADS ,ALL EXISTING LOADS | | | AND THE EXISTING OR PROPOSED SERVICE | | | SPECIFICATIONS PER 215.15. | | | | | | 2} PLEASE PROVIDE A PANEL SCHEDULE SO | | | THAT BRANCH/FEEDER CIRCUIT CONDUCTOR AND | | | OVER CURRENT PROTECTION COMPLIANCE MAY | | | BE REVIEWED PER 215.5 AND 106.3.5.4 FBC | | | AS AMENDED. INCLUDE NEW LOADS. | | | | | | 3}THE PERSON TAKING RESPONSIBILITY FOR | | | THE DESIGN MUST PRINT AND SIGN THEIR | | | NAME TO SAME PER 106.3.4.2. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-31 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-08-31 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2006-08-31 00:00:00 | ***APPROVED*** | | | | | | 1) SEPARATE SHOP DRAWINGS AND PERMIT | | | REQUIRED FOR FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL IF APPLICABLE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-09 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-09 |
Time |
18:59 |
Sent To |
E |
|
| Notes |
| 2006-09-09 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-06 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-16 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2006-08-24 00:00:00 | TO "BOB"#14 | | 2006-08-16 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-06 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-06 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2006-09-06 00:00:00 | NO PLUMBING PLANS REQUIRED - FIXTURE | | | CHANGE-OUT IN SAME LOCATION. |
|
|
|